VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Similar documents
Partner Valve/High Quality Ball Valve LENO MSV-S

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

living connect, Electronic Radiator Thermostat

Basic Plus2 Room Thermostats Floor Heating

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Product overview All you need to know about choosing valves and thermostats

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

2-way. One source of elements. Many opportunities for greater profits. communication

Thermostatic valves with radiator connection systems

RA2000 Commercial TRVs

FHM-Cx Mixing Shunts for Floor Heating

24/7 home heating control from anywhere with the Danfoss Link App

Multilux 4-Eclipse-Set

RA15/6T & TB Conversion Valve

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

RA 2000 Series RA 15/6T & TB Conversion Valve

FHM-Cx Mixing Shunts for Floor Heating

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

Increase the attractiveness of your multi-family building

Installation Guide. DEVIreg 330 (-10 to+10 C) Electronic Thermostat.

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

caleffi hydronic valves page 1 of 12

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Installation Guide. DEVIreg 233. Electronic Thermostat.

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

Installation and user guide Accumulator tanks

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Installation Guide. DEVIreg 610. Electronic Thermostat.

Flush individual room control for floor heating systems

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Mikrotherm. Manual Radiator Valves With presetting

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Thermostatic valve bodies

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

Temperature controller for steam (PN 25) AVT / VGS - external thread

Installation Guide. DEVIreg 535. Electronic Thermostat.

Radiator Valve Program

SonoSelect and SonoSafe energy meters

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Automatic balancing valves ASV-PV (new generation) DN 32-50

2 DESCRIPTION OF SYSTEM COMPONENTS

Regulux. Radiator lockshield with drain-off facility. To be precise.

Water mist nozzles With anti-drip

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

3 years payback time. Millions of reasons to choose the best.

Membrane cleaning of RO-system with the isave unit

Installation Guide. DEVIreg 534. Electronic Thermostat.

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

DEVIreg 330 (+5 to +45 C) Electronic Thermostat

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Air Heating Surfaces

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 130. Electronic Thermostat.

manifold, for radiators

Installation and operation manual for mixing modules FH-MJB and FH-MJC

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

IMI Heimeier Kit Hydroca ble

Three-way reversing valve

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

PENSOTTI TOWEL BAR WARMERS

SonoSelect and SonoSafe energy meters

Control valves for floor heating systems. Floor Heating Manifolds

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

Thermostatic valve bodies

Danfoss Link FT Floor Thermostat

HERZ Differential Pressure Control Valve 4002

Halo. Thermostatic heads with built-in sensor

Radiator Trap Radiator Valve

thermostatic valve body with stepless precision presetting

Domestic Hot Water Application manual

Ducasa, experts in advanced heating

DHP-H Varius Pro+/DHP-L Varius Pro+

HERZ Regulating valve 4002

Brazed heat exchanger XB

Increased safety and reducing energy consumption with the motion control RPI 01

Transcription:

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails Application VHX floor connection VHX wall connection The VHX-sets are specially designed for towel rails and designer radiators with '50 mm bottom connection' and ½ connection to the radiator. The VHX-sets include a RAX thermostatic sensor for room temperature regulation. The sets provides the perfect finishing touch for towel rails. The aesthetically pleasing and compact design allows the sensor to be mounted under-neath the towel rail, parallel with the wall. VHX valves controls the return flow from the radiator and have several features: free choice of left/right mounting direction available in versions for floor or wall connection built-in shut-off function four different surfaces matching most radiators Ordering VHX set Description VHX-DUO valve set, with RAX return flow sensor VHX-MONO valve set, with RAX return flow sensor Colour Code no. Straight Code no. Angle Chrome 013G4276 013G4279 RAL 9016 013G4278 013G4281 Chrome 013G4282 013G4285 RAL 9016 013G4284 013G4287 Danfoss Heating Solutions VDUYQ502 Danfoss 10/2011 1

Compression fittings Description For steel and copper tubes For AluPex tubes For Pex tubes Size Code no. Nickel plated Code no. Chrome plated 8 mm 013G4108 10 mm 013G4110 013G4192 12 mm 013G4112 013G4193 14 mm 013G4114 013G4194 15 mm 013G4115 013G4195 16 mm 013G4116 013G4196 12 x 2 mm 013G4172 14 x 2 mm 013G4174 16 x 2 mm 013G4176 013G4200 12 x 1.1 mm 013G4143 013G4197 12 x 2 mm 013G4142 14 x 2 mm 013G4144 15 x 2.5 mm 013G4147 013G4199 16 x 2 mm 013G4146 013G4198 Accessories Product Code no. Electric heating element - 40 cm - 150 W - 1.2 m w/ Schuko plug 1) 013G4167 Electric heating element - 47 cm - 300 W - 1.2 m w/ Schuko plug 1) 013G4168 Electric heating element - 70 cm - 600 W - 1.2 m w/ Schuko plug 1) 013G4169 Adapter for electric heating element 013G4166 O-ring service set for VHX MONO angle valve and VHX DUO angle valve 2) 013G4179 O-ring service set for VHX DUO straight valve 013G4180 O-ring service set for VHX MONO straight valve 013G4181 1) Electric heating elements are according to the standard UNEL 47168/68-CEE (7) xvll. 2) Complete O-ring replacement of VHX DUO angle valve requires 2 x 013G4179. Technical Data Type Connection k v -values [m³/h] with RAX sensor at setting 1) (k vs ) Rad. Sys. 1 2 3 4 5 6 7 N N VHX-DUO G½A G½ 0.12 0.15 0.20 0.25 0.30 0.36 0.42 0.49 0.56 VHX- MONO G½A G½ 0.12 0.15 0.20 0.25 0.30 0.34 0.38 0.40 0.45 Max. work. pressure: 10 bar, max. diff. pressure 2) : 0,6 bar, test pressure 16 bar, max. flow temp.: 120 C 1) The k v -value indicates the water flow (Q) in m³/h at a pressure drop (Δp) across the valve of 1 bar;. At setting N the k v -value is stated according to EN 215, at XP = 2K i.e. the valve is closed at 2 C higher room temperature. At lower settings the X P value is reduced to 0.5K of the setting value 1. The k vs -value states the flow Q at a maximum lift, i.e. at fully open valve at setting N. 2) The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. The differential pressure can be reduced by the use of the Danfoss differential pressure regulators. 2 VDUYQ502 Danfoss 10/2011 Danfoss Heating Solutions

RTX has - due to its mode of operation - a very limited influence on the hydraulic balance of the heating system. Changing the k v -setting from "N" (factory setting) is therefore seldom required. Capacities VHX-DUO (RAX) (pre-setting) VHX-MONO (RAX) (pre-setting) Danfoss Heating Solutions VDUYQ502 Danfoss 10/2011 3

Temperature Setting RAX thermostatic sensor 0= Positive shut off 8 12 16 20 24 28 C = Frost protection setting 0 I II III IIII I Pre-Setting Danfoss pre-settable valve assemblies incorporate easy setting adjustment with clearly engraved setting markers scaled from 1-7 and N. Setting values can be set quickly and precisely, without the need for tools, as follows: Remove protective cap or sensor. Turn red ring to the desired setting value. The preset level can be selected in 0.5 increments between 1 and 7 (see chart for flow rates). At setting N the valve is fully open (flushing option). 4 VDUYQ502 Danfoss 10/2011 Danfoss Heating Solutions

Installation VHX-DUO floor connection VHX-MONO floor connection Free connection (left or right). Radiator outlet always on thermostat side. Free connection (left or right). Radiator outlet always on thermostat side. VHX-DUO wall connection VHX-MONO wall connection Free connection (left or right). Radiator outlet always on thermostat side. Free connection (left or right). Radiator outlet always on thermostat side. RTX sensor Mounted directly on the valve with an Allen key (enclosed in set) Danfoss Heating Solutions VDUYQ502 Danfoss 10/2011 5

Electric Heating Element Danfoss electric heating elements can be mounted in the radiator through the VHX-DUO angle valve. Mounting of a standard heating element (non- Danfoss) through the valve requires use of the adapter 013G4166. The heating element s wattage must be selected so that the wattage emitted on the heating element is always less than half of the nominal wattage the radiator can emit. If a heating element is to be used with other VHX valves, a standard heating element (non-danfoss) has to be mounted directly in the radiator. Examples: Mounting of an electric heating element Danfoss Standard (non-danfoss) Standard (non-danfoss) Dimensions G½A G½A 80 43 35,5 46 G½ 19 50 32,8 80 16 50 18,5 32 34,8 45 45,1 35 20 43 46 G½ 21 45 38 26 50 21 45 VHX-DUO floor connection VHX-DUO wall connection Ø 11 x 205 mm Ø 11 x 205 mm G½A G½A 35,5 16 25 44 80 32 34,8 45 43 46 20 43 46 G½ 19 25 44 80 38 G½ 26 45,1 35 21 45 44 19 25 44 21 45 VHX-MONO floor connection VHX-MONO wall connection 6 VDUYQ502 Danfoss 10/2011 Danfoss Heating Solutions

Danfoss Heating Solutions VDUYQ502 Danfoss 10/2011 7

Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone:+45 7488 8000 Fax: +45 7488 8100 Email: heating.solutions@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 VDUYQ502 Danfoss 10/2011 Danfoss Heating Solutions