Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves
|
|
- Brett Nelson
- 6 years ago
- Views:
Transcription
1 Vekotrim Valves for radiators with integrated valve Double connection fitting with shutoff ball valves for radiators with
2 IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Vekotrim The Vekotrim double connection fitting is designed for installation onto radiators with with an Rp 1/ female thread and G /4 male thread. Self sealing connections enable easy mounting to the radiator. Models in angle and straight forms, each designed for twopipe systems, mean that the connection fitting can be used in a number of different ways. Key features > > Easy operating with screw driver > > Stem sealing with EPDM Orings > > Supply and return pipes can be shutoff separately > > For left and right connection to the radiator Technical description Applications area: pipe heating systems Function: Shutoff Dimensions: DN 1 Pressure class: PN Temperature: Max. working temperature: 1 C Min. working temperature: C Materials: Valve body: Brass Orings: EPDM rubber Flat sealing: EPDM rubber Ball seal: PTFE Surface treatment: Valve body and fittings are nickelplated. Radiator connection: Adapters for R1/ or according to EN 161 (Eurocone), for radiator connections. Tolerance compensation ±1,0 mm with special union nuts and flexible flat seal system for installation free of tension. Pipe connection: male thread according to EN 161 (Eurocone) for compression fittings for plastic, copper, precision steel or multilayer pipe.
3 Construction Vekotrim 1. Body nickel plated. Shutoff ball valve. Flat sealing Application The Vekotrim double connection fitting is designed for installation onto radiators with with an Rp1/ female thread and male thread. Self sealing connections enable easy mounting to the radiator. Models in angle and straight forms, each designed for twopipe systems, mean that the connection fitting can be used in a number of different ways. For example, the straight form can be used for pipe connection vertical to the floor. If a free floor area is required, the angle form is used for the wall connection. Radiators can be shut off individually with the Vekotrim connection fitting. For dismounted radiators decorating and service work, for example, can be carried out without interruption to other radiators. Mounting of the Vekotrim connection fitting is possible on the left as well as on the right of the radiator. This is especially advantageous when the radiator is turned around. Sample application Twopipe system 1. Vekotrim. Radiator. Thermostatic head
4 IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Note To avoid damage and the formation of scale deposit in the hot water heating system, the composition of the heat transfer medium should be in accordance with the VDI guideline. For industrial and longdistance energy systems, see the applicable codes VdTÜV and 1466/AGFW FW. A heat transfer medium containing mineral oils, or any type of lubricant containing mineral oil can have extremely negative effects and usually lead to the disintegration of EPDM seals. When using nitritefree frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly concerning concentration and specific additives. Operation Shutoff Supply and return of Vekotrim are closed by using a screw driver (slot size 8. mm x mm) and turning the slots in a horizontal position. 4
5 Technical data Diagram, Vekotrim twopipe connection fitting Thermostatic insert VHV with 6 presetting ranges 0 Thermostatic insert VHV8S with 8 infinitely variable presetting values *) *) 1 1 0, 0, 0, 0, p [kpa] 0, 0,1 1 ª [kg/h] p [mbar] p [kpa] 0, 0,1 ª [kg/h] p [mbar] Radiator with integrated valve with Vekotrim twopipeconnection fitting Presetting Thermostatic insert Thermostat insert VHV with 6 presetting ranges and Thermostatic head min Kvvalue max 0,0 0,047 0,047 0,16 0,16 0,66 0,66 0,401 0,401 0,69 0,69 0,761 Kvs 0,01 0,1 0,90 0,418 0,9 0,861 Thermostat insert VHV8S with 8 infinitely variable presetting values and Thermostatic head Kvvalue 0,1 0, 0,1 0,7 0,4 0,4 0,6 0,69 Kvs 0,16 0,7 0,7 0,4 0,61 0,86 1,0 1,1 Kvs Vekotrim without radiator *) 1,80 1,80 Kv/Kvs = m /h at a pressure drop of 1 bar. Calculation example Required: Presetting value Given: Heat flow Q = 11 W Temperature spread Δt = 1 K (6/ C) Pressure loss thermostatic valve Δp V = 44 mbar Solution: Mass flow m = Q / (c Δt) = 11 / (1,16 1) = 6 kg/h Presetting value from diagram: with thermostatic insert VHV with 6 presetting ranges: 4 with thermostatic insert VHV8S with 8 infinitely variable presetting values: Kv Cv = 0,86 Kv = Cv 0,86
6 IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Articles Angle 7 R1/ R1/ SW Connection radiator with Twopipe system Kvs *) Rp 1/ female thread 1, SW Connection radiator with Twopipe system Kvs *) G /4 male thread 1, Straight 8 R1/ R1/ SW Connection radiator with Twopipe system Kvs *) Rp 1/ female thread 1, Connection radiator with Twopipe system Kvs *) G /4 male thread 1, *) common value for supply and return pipes. Kv/Kvs = m /h at a pressure drop of 1 bar. 6
7 Accessories Compression fitting for copper or precision steel pipe according to DIN EN 7/1/. Connection male thread G /4 according to DIN EN 161 (Eurocone). Metaltometal joint. Brass nickelplated. With a pipe wall thickness of 0.81 mm insert supporting sleeves. Heed pipe manufacturer s technical advice. Ø Pipe Support sleeve for copper or precision steel pipe with a 1 mm wall thickness. Brass. Ø Pipe L 1, , , , Compression fitting for copper or precision steel pipe according to DIN EN 7/1/. Connection male thread G /4 according to DIN EN 161 (Eurocone). Soft sealed, max. 9 C. Nickelplated brass. Ø Pipe Compression fitting for plastic pipe according to DIN 476, ISO 8. PEX: DIN 1689/1689, EN ISO 187; PB: DIN 16968/ Connection male thread G /4 according to DIN EN 161 (Eurocone). Nickel plated brass. Ø Pipe 14x x x x x Compression fitting for Alu/PEX multilayer pipe according to DIN Connection male thread G /4 according to DIN EN 161 (Eurocone). Nickelplated brass. Ø Pipe 16x x Double rosette Dividable in the middle, made of plastic, white, for various pipe diameters. Centre distance mm. Overall height max. 1 mm
8 IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Deflector piece, angle for exchanged supply and return, Connection for Rp 1/ and G /4, flat sealing, with shutoff, for twopipe systems, to prevent connection ducts from intersecting. Nickelplated brass. Connection / R1/ Deflector piece, straight for exchanged supply and return, Connection for Rp 1/ and G /4, flat sealing, with shutoff, for twopipe systems, to prevent connection ducts from intersecting. Nickelplated brass. Connection / R1/ Sconnection set consisting of adapter pieces x. Brass nickelplated. Set 1 Set Model Axial distance min. 40/ to max. 60/ Axial distance min. / to max. 6/ The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit Vekotrim ed..17
E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems
E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion
More informationMultilux 4-Eclipse-Set
Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux
More informationThermostatic valves with radiator connection systems
Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator
More informationCalypso exact. Thermostatic Radiator Valves With stepless precision presetting
Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationFor reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting
For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed
More informationMikrotherm. Manual Radiator Valves With presetting
Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,
More informationThermostatic valve bodies
Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single
More informationStandard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation
Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic
More informationControl valves for floor heating systems. Floor Heating Manifolds
Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control
More informationThermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control
Thermostatic three-way valve body Thermostatic Radiator Valves without presetting, with automatic bypass control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic three-way valve body
More informationDesign-Edition. Design-Edition Thermostatic valves and lockshields, sets
Design-Edition Design-Edition Thermostatic valves and lockshields, sets IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationRegulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility
Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump
More informationIMI Heimeier Kit Hydroca ble
IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding
More informationV-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting
V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve
More informationEclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation
Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic
More informationEclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation
Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic
More informationregulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge
regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent
More informationStandard. Thermostatic Radiator Valves Thermostatic valve body without presetting
Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used
More informationFloor Control Set. Floor Heating Controller For constant control of the supply temperature
Floor Control Set Floor Heating Controller For constant control of the supply temperature IMI HEIMEIER / Floor Heating Control / Floor Control Set Floor Control Set The Floor Control Set with return addition
More informationThree-way reversing valve
Three-way reversing valve For heating and cooling systems Pressurisation & Water Quality Balancing & Control thermostatic Control engineering avantage Three-way reversing valve for the distribution of
More informationDynalux. Floor Heating Manifolds Underfl oor heating circuit manifold
Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in
More informationMultibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off
Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is
More informationStandard. thermostatic valve body without presetting
Standard thermostatic valve body without presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEErInG advantage The standard thermostatic valve bodies are used in two-pipe
More informationCalypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting
Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic
More informationTRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield
TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield IMI HEIMEIER / Thermostatic heads and Radiator valves /
More informationMultibox. Floor Heating Controller Flush individual room control for floor heating systems
Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for
More informationRegulux. Radiator lockshield with drain-off facility. To be precise.
Radiator lockshield with drain-off facility To be precise. Description Assembly Regulux Closing cap Thrust piece HEIMEIER radiator lockshield for shutting off, presetting, draining off and filling. Separate
More informationThermostatic valve bodies
Thermostatic valve bodies for all thermostatic heads and actuators Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermosTaTic valve bodies Table of contents
More informationFlush individual room control for floor heating systems
Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control
More informationthermostatic valve body with stepless precision presetting
Thermostatic Radiator Valves V-exact II thermostatic valve body with stepless precision presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE V-exact II
More informationthermostatic inserts for radiators with integrated valves
s for radiators with integrated valves Pressurisation & Water Quality Balancing & Control Thermostatic Control engineering advantage valves for radiator with integrated valve technical description heimeier
More informationMultibox. Flush Individual Room Control for Floor Heating Systems. To be precise.
Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article
More informationThermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control
Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion
More informationHERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.
Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationHERZ Regulating valve 4002
HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN
More informationHERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22
HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples
More informationV2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS
W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix
More informationmanifold, for radiators
MMA, for radiators Eco-friendly materials, low lead content Quiet Precise and linear Dimension: DN 0 Temperature: C to + C Pressure class: PN 0 Description Area of use The Evoflow radiator is especially
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure
More informationBrawa-Mix Thermostatic mixing valves
Technical information Tender specification: The Oventrop thermostatic mixing valve Brawa-Mix without dead zone mixes hot and cold water according to an infinitely adjustable water temperature. The thermostatic
More informationGlobo H. Ball valves Gunmetal ball valve
Gobo Ba vaves Gunmeta ba vave IMI EIMEIER / Shut-off vaves / Gobo Gobo Gobo is used as a versatie shut-off eement in pump hot-water heating systems. Thanks to the compact working radius of the operating
More informationPartner Valve/High Quality Ball Valve LENO MSV-S
Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.
More informationConnection set. Radiator connection set for thermostatic and manual operation Ø 12
Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies
More informationFLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe
FLOWRETT, TA-UNI Thermostatic valves with radiator connection system One-pipe IMI TA / Thermostatic heads and Radiator valves / FLOWRETT, TA-UNI FLOWRETT, TA-UNI Compatible with most radiators on the market,
More informationCONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS
CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS INSTALLATION INSTRUCTIONS FOR CONTROL BOXES Pay attention to the total pressure loss when connecting UV4- to the control boxes for heating areas > 16 m²!
More informationRadiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function
HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection
More informationTS RD 7761 RD, 7761 RD
1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum
More informationThermostatic head B. Thermostatic heads Secured model designed for public buildings
Thermostatic head B Thermostatic heads Secured model designed for public buildings IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head B Thermostatic head B The thermostatic head B
More informationSay heating. Say Herz. HERZ-Supply Engineering
HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield
More informationTA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water
TA-MATIC Mixing valves Thermostatic mixing valve for domestic hot water IMI TA / Potable water / TA-MATIC TA-MATIC Thermostatic mixing valve for control of domestic hot water systems in apartment blocks
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,
More informationTHERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES
FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat
More informationAquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes
Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control
More informationTHERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION
THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON
More informationProblem-solvers The Radiator Solution Range
Simplex Problem-solvers Problem-solvers The Radiator Solution Range I Height and depth compensation I Continuously swivelling connections I Reversal of supply and return flow I Quick and clean radiator
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationTHERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES
FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat
More informationAutomatic balancing valves ASV-PV (new generation) DN 32-50
Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator
More informationZeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology
Zeparo Cyclone Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo Cyclone Zeparo Cyclone Comprehensive
More informationEnergy Saving Series RADICAL
RADICAL The Stelrad Radical Energy Saving Radiator can save up to 10.5% on energy bills, delivering higher comfort levels at a lower thermostat setting. That s radical thinking, from Stelrad. It s the
More informationHalo. Thermostatic heads with built-in sensor
Halo Thermostatic heads with built-in sensor IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Halo Halo The thermostatic head Halo is used to control the temperature of individual rooms using, for
More informationTHERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES
ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield
More informationV2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS
V2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS PRODUCT DATA Design The H-block valve consists of: Straight valve body for floor connection or angle valve body for wall connection Valve
More informationValves, controls + systems Flow, pressure and temperature balancing
Innovation + Quality Valves, controls + systems Flow, pressure and temperature balancing Product range Flow, pressure and temperature balancing Content Page Flow, pressure and temperature balancing Necessity
More informationV2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE
V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE Application Thermostatic flowshare valves control the output of radiators in vertical one-pipe heating systems. Heating water not required
More informationInstallation and operating instructions
Installation and operating instructions To be precise. Installation and operating instructions Table of contents General notes Page Thermostatic valve 3 Faults Causes Remedial action 4 Temperature setting
More informationSettlement Agreement. Schedule 1: Covered Products
Settlement Agreement Schedule 1: Covered Products COVERED PRODUCT BRANDS BRASSCRAFT PLUMBSHOP PEERLESS SOLUTIONS MASTER PLUMBER COVERED PRODUCT CATEGORIES - WATER SUPPLIES SUPPLY STOPS WATER SUPPLY CONNECTORS
More informationRA2000 Commercial TRVs
RA2000 Commercial TRVs www.heating.danfoss.co.uk Danfoss Limited Ampthill Road Bedford MK42 9ER E: ukheating@danfoss.com W: www.heating.danfoss.co.uk Reception Tel: 01234 364621 Fax: 01234 219705 UK Sales
More informationDistributors for Floor Heating Systems
Distributors for Floor Heating Systems Rod-type distributor, Dimension 1" Standard Sheet for 8531/8532 Edition 0200 (0799) Rod-type distributor sets with shutoff- and thermostatic upper parts Rod-type
More informationSOLUTIONS GUIDE. For total efficiency
2014-2015 SOLUTIONS GUIDE For total efficiency THERMOSTATIC RADIATOR HEADS Comap Thermostatic heads have been counted amongst the best sellers in Europe for decades, thanks to their high manufacturing
More informationEMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.
Thermal actuator for heating, ventilation, and air conditioning systems To be precise. Description The EMO T thermal actuator is a VDE-tested two-point actuator for connecting to room temperature controllers
More informationTemperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)
Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:
More informationArt-Line. Absolutely Brilliant Temperature control was never so good
Art-Line Absolutely Brilliant Temperature control was never so good Pressurisation & Water Quality Balancing & Control thermostatic Control engineering ADVANTAge art-line 16 unique decors for individualists
More informationRadiator Trap Radiator Valve
Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems
More informationDynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control
Dynacon Ecipse Foor Heating Manifods Foor heating manifod with automatic fow contro IMI HEIMEIER / Foor Heating Contro / Dynacon Ecipse Dynacon Ecipse Dynacon Ecipse adjusts the fow rate in the individua
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems
More informationHERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien
HERZ-Thermostatic and Return Valves Standard Sheet for DE LUXE Edition 1000 (0999) This series consists of HERZ radiator thermostats, HERZ-TS-90 thermostatic valves and HERZ return valves. These components
More informationRadical CPD BIM.
Radical At the forefront of innovation, Stelrad has developed the next generation in energy saving radiators, the Radical. As the first serial feed radiator this ground breaking solution reduces energy
More informationThermostatic head K. Thermostatic heads with built-in sensor and remote sensor
Thermostatic head K Thermostatic heads with built-in sensor and remote sensor IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K Thermostatic head K The thermostatic heads K are
More informationTechnical Sheet. Hybrid concealed radiator System Insulated Rubber Pipe
System Insulated Rubber Pipe The 3THERMO radiator (concealed or for drywall installation) is adjusted for serial connections. The recommended system installation is SIRK. The radiator should be covered
More informationTemperature controller for steam (PN 25) AVT / VGS - external thread
Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic
More informationVHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails Application VHX floor connection VHX wall connection The VHX-sets are specially designed for towel rails and designer
More informationRA15/6T & TB Conversion Valve
Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from
More informationcaleffi hydronic valves page 1 of 12
caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series
More informationproduct overview ProControl
product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.
More informationHELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1
Introduction The Bottom Feed solar water heater connector is meant to connect solar water heater panels directly to your existing standard water heater. It's main advantages are ease of installation, efficiency,
More informationInstallation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K36E Modular Heating
More informationTechnical Product Guide
FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,
More informationTP /4-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html
More informationValves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.
Innovation + Quality Valves, controls + systems Local and district heating technology for improved energy efficiency Product range Local and district heating technology The term Local and district heating
More informationRA 2000 Series RA 15/6T & TB Conversion Valve
RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water
More informationWAL-RICH CORPORATION SINCE 1950
STEAM SPECIALTIES ANGLE STEAM RADIATOR VALVES 0408102 1/2 1 10 0408104 3/4 1 6 0408002 1" 1 4 0408004 1 1/4" 1 2 0408006 1 1/2 1 2 - Brass - Imported STRAIGHT STEAM RADIATOR GATE VALVES 0409002 1" 1 4
More informationSelf-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2
Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43- Type 43-2 Application Regulators for district heating supply systems, heat generators, heat exchangers, and other building
More informationIMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:
1½ or 2 RG IMMERSION HEATERS PAGE 1/5 Immersion heaters* are used to heat a variety of mediums, e.g. water, glycol, oil, and other liquids. It is important that the immersion heater is fitted to the side
More informationTRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield
TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode Angle Pattern
More information