TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Size: px
Start display at page:

Download "TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield"

Transcription

1 TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield GENERAL INFORMATION Size Pattern No. Pack 1 Qty Code Barcode Angle Pattern TRV & Lockshield Pack Angle Pattern TRV & Lockshield Pack Angle Pattern TRV & Lockshield Pack Angle Pattern TRV & Lockshield Pack Irish Cone DIMENSIONS (mm) Code Description A B C D E F MMX1/2 CP TERRIER II TRV & LS PACK MMX1/2 CP TERRIER II TRV & LS PACK MMX1/2 CP TERRIER II TRV & LS PACK PRESSURE & TEMPERATURE TRV & Lockshield Pack Minimum Operating Pressure (bar) Maximum Cold Working Pressure (bar) Maximum Hot Working Pressure (bar) 8MMX1/2 CP TERRIER II TRV & LS PACK No Minimum Operating Pressure 10.0 bar at temperatures up to 120oC Not Suitable for Maximum Hot Working Pressure MATERIAL SPECIFICATIONS Number Component Material 1 Body TRV - Forged Brass Chrome Plated 2 Head TRV - Brass Bar 3 Gland TRV - Brass Bar 4 Flow Spindle TRV - Stainless Steel 5 Capnut TRV - Forged Brass Chrome Plated 6 Cone TRV - Brass Bar 7 Adaptor TRV - Brass Bar Chrome Plated 8 Thermal Head Cover/Body TRV - ABS 9 Thermal Head Element/Housing TRV - Noryl 10 Body LS - Forged Brass Chrome Plated 11 Head LS - Brass Bar 12 Spindle/Valve LS - Brass Bar 13 Glandnut/Gland LS - Brass Bar 14 Adapter LS - Forged Brass Chrome Plated 15 Capnut LS - Forged Brass Chrome Plated 16 Cone LS - Brass 17 Set Screw LS - Brass 18 Lockshield LS - Polypropylene SPARES

2 1 Date To TH2 THERMAL HEAD TH1 THERMAL HEAD - DISCONTINUED TH2 THERMAL HEAD TH1 THERMAL HEAD - DISCONTINUED TH2 THERMAL HEAD TH1 THERMAL HEAD - DISCONTINUED /06/1998 current /01/ /04/ /06/1998 current /01/ /04/ /06/1998 current /01/ /04/2009 HK68 COMPLETE CARTRIDGE 1/2 HK68 COMPLETE CARTRIDGE 1/2 HK68 COMPLETE CARTRIDGE 1/2 3 Date To /06/1998 current /06/1998 current /06/1998 current Date To DC4 DUST CAP /01/ /05/1998 DC4 DUST CAP /06/1998 current DC4 DUST CAP /01/ /05/1998 DC4 DUST CAP /06/1998 current DC4 DUST CAP /06/1998 current DC4 DUST CAP /01/ /05/ Date To /06/1998 current /01/ /05/ /01/ /05/ /06/1998 current /06/1998 current /01/ /05/1998 CARE & MAINTENANCE LP7 LOCKING PIN (PACK OF 2) LP7 LOCKING PIN (PACK OF 2) LP7 LOCKING PIN (PACK OF 2) Date To /01/1900 current /01/1900 current /01/1900 current Care The TRV can be easily cleaned with a soft damp cloth wiping over the handle (plastic) and valve body. Maintenance No maintenance is required for this product. When removing the TRV head for decorating or replacement purposes, turning the head setting to 5, this enables an easier removal. A manual shut off cap is provided with the product to protect the valve whilst any surrounding maintenance work is undertaken. For any further help or replacement parts please contact the Service Support Team on:

3 REGULATIONS Regulations Terrier thermostatic radiator valves are approved to EN 215. For valves with compression connections, the connections are approved to BS EN1254-2; threaded connections comply with BS 21 or BS They are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose. They must be used within the pressure and temperature limits stated in the technical information table below. Operating Conditions Maximum System Water Temperature (at 5bar) 120 C Operating pressure (at 65 C) 10 bar Under no circumstances must they be used in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer's instructions. Terrier heating controls are manufactured to a strict quality assurance system in accordance with ISO 9000: GUARANTEE Thermostatic and Manual Radiator Valves Pegler Yorkshire Customcare 5 Year Guarantee - Terms & Conditions Products are subject to a 5 year guarantee that is between Pegler Yorkshire and the final purchaser of the product. The guarantee is subject to proof of purchase being supplied. This guarantee does not affect any statutory rights the consumer may have in law. The guarantee covers manufacturing or material defects and is not applicable where the product is fitted contrary to conditions of use in our literature. The guarantee is subject to the following limitations: 1. The valves are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose. 2. They must be used within the pressure and temperature limits stated in the technical information table below. Operating Conditions (Maximum) System Water Temperature (at 5bar) : 120 C Operating pressure (at 65 oc) :10 bar 3. Under no circumstances must they be used to in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer s instructions. 4. Damage caused by abusive behaviour and accidental damage to the product are not covered by this guarantee The extent of Pegler Yorkshire liability is limited to the cost of the replacement of the defective item and not to fitting or consequential damages. APPROVALS Keymark License EN215

4

5 terrier trv 8/9/04 2:25 pm Page 1 4. Range Limiting or Fixed Set Temperature The terrier TRV has the facility for fixing the thermal head at a set temperature or to limit the range of operation. This is achieved by using the two pegs provided with the product. To obtain a fixed set point, locate a peg in the slot either side of the selected setting and push home. To set a limited range for temperature control, first locate a peg in the slot to the right of the viewing window for the lowest temperature setting required. Adjust the valve head to display the maximum temperature desired. Locate a peg in the slot to the left side of the viewing window. Push both pegs home. The head will now be adjustable between the selected range of temperature. 5. Frost Protection If you plan to be away from home for any length of time the TRV can be turned to the frost protection setting. If the temperature falls below 7 C the valve will automatically open giving protection against freezing. (Provided that the boiler remains in operation via a frost stat.) 6. Removal of Radiator TWO WAY THERMOSTATIC RADIATOR VALVE TECHNICAL DATA Temperature range 7 C - 28 C Maximum Test Pressure 20bar Maximum Static Pressure 10bar at 120 C Maximum Differential Pressure 0.6bar Maximum Water Flow Temperature 120 C The 0 Setting on the TRV is a positive Off position. This will enable a radiator to be removed for maintenance purposes. To avoid accidental operating of the valve or damage whilst decorating the manual shut off cap may be used for added security instead of the TRV head. In this case, remove the TRV sensor head by unscrewing the securing ring and replacing with the manual cap BEFORE removing the radiator. Pegler Limited, St. Catherines Avenue, Doncaster DN4 8DF. Telephone: Fax: TWO WAY THERMOSTATIC RADIATOR VALVE Installation and User Guide SENSOR HEAD MANUAL SHUT OFF CAP 1/2 BSP TAIL VALVE BODY VALVE BODY STRAIGHT

6 terrier trv 8/9/04 2:25 pm Page 2 INSTALLATION Directions for use: Angle TRV The universal terrier TRV is designed to operate with water flow in either direction. The 15mm size may be fitted in either the horizontal OR vertical position. The most effective position is to have the head in a horizontal position where the greatest efficiency will be obtained. Straight TRV Straight bodied valves should not be used in the top connection of a radiator as heat from the radiator will affect the sensor. Correct installations Correct installation and maximum performance will be achieved if: The thermostatic head is not concealed behind furniture, curtains or drapes, hidden under shelves, panelling or in a recess where air pockets can occur. The thermostatic head is not exposed to direct sunlight or draughts. Straight TRV x Fitting 1. Thoroughly clean any pipe work to be connected to the valve. 2. Drain down existing system, connecting a hosepipe to the lowest drain off point available. 3. Screw 1/2 BSP tail into radiator tapping, using suitable jointing material e.g. PTFE tape. 4. Connect valve body to tail and tighten nut. 5. Cut and fit copper tube to valve body - tightening nut and cone. 6. Remove manual shut off cap and store safely. 7. Turn Sensor head to indicate 5 in setting window. 8. Position sensor head so that setting window can be viewed and hand tighten securing ring to valve body. 9. Set sensor head to required temperature setting. 10. When fitting a lock shield valve, this must be set to control the water flow through the radiator to the correct level. PLEASE NOTE: To avoid the problem of hydronic (water flow) noise it is recommended that the differential pressure does not exceed 0.2 bar. It is strongly recommeded that a differential pressure valve should be fitted to any system with TRV s (Pegler order code for differential pressure valve /22mm) will be suitable for most domestic installations. Larger sizes are available if required. Angle TRV USER INSTRUCTIONS 1. Operating Description The influence of uncontrolled heat gains from cooking, lighting and sunshine etc., can lead to wasteful overheating. The terrier TRV is designed to react to temperature fluctuations and allow you to control individual room temperature. The sensor head contains a powerful wax-filled sensor which senses temperature changes. These variations cause expansion and contraction of the thermal element which is transmitted to a valve seat which regulates the water flow to the radiator 2. Setting the TRV Initially set the TRV to the required room temperature from the table below e.g. Position 3/ 20 C. The TRV should be left for at least 1 hour to allow the temperature to stabilise. If a higher or lower room temperature is required simply adjust the setting accordingly and repeat the process. 3. Temperature Settings The TRV settings are factory calibrated as indicated in the table below Shut Off 7 C C C C C C Note: These temperatures may vary slightly, depending upon the nature of the installation

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern TRV & drain off lockshield pack Size Pattern No. Pack 1 Qty

More information

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar)

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar) For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk Rune Monobloc Dualflow Sink Mixer Monobloc Sink Mixer GENERAL INFORMATION Pattern No. key

More information

Komo Thermostatic Bar Shower. Excluding Shower Kit

Komo Thermostatic Bar Shower. Excluding Shower Kit Komo Thermostatic Bar Shower. Excluding Shower Kit Bar Shower Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT NA Bar Shower CP 1 0 4S4001 5013866052750 180.25 Bar Shower Code 4S4001

More information

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers Opal Bath Tap Bath Tap Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT Bath Tap Code A B C D Pegler Yorkshire reserve the right to change specifications 10 Year Guarantee Luxury Taps

More information

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

For more information on Pegler Yorkshire visit  Heating Controls. Radiator valves with new integral push-fit inlet Heating Controls Radiator valves with new integral push-fit inlet Heating Controls Radiator valves with new integral push-fit inlet Terrier is a name which should need no introduction to the professional

More information

Thermostatic Bath Shower Mixer. Without shower kit.

Thermostatic Bath Shower Mixer. Without shower kit. Thermostatic Bath Shower Mixer. Without shower kit. 555QT Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex 555QT Code A B C D E F Pegler Yorkshire reserve the right to change specifications

More information

Basin Tap. Time delay maximum 2 seconds

Basin Tap. Time delay maximum 2 seconds Basin Tap. Time delay maximum 2 seconds 876 Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex 1/2 876 Hot 1 5 314007 5013866005022 142.41 1/2 876 Cold 1 5 314017 5013866005039 142.41 876

More information

Union coupling. copper x copper. Cone joint to BS 1010.

Union coupling. copper x copper. Cone joint to BS 1010. Union coupling. copper x copper. Cone joint to BS 00. YP Size Pattern No. Pack Qty Pack 2 Qty Code Barcode Price ( ) ex VAT 8mm YP 5 00 08250 502205008250 2.78 5mm YP 0 00 0825 502205008250 8.4 22mm YP

More information

Male elbow, copper x BSP taper male thread

Male elbow, copper x BSP taper male thread Male elbow, copper x BSP taper male thread YP13 Elbow Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT test 15mm x 1/2" YP13 10 240 08333 5022050083333 16.22 22mm x 3/4" YP13 5 100

More information

Heating Controls Thermostatic and Manual Radiator Valve range

Heating Controls Thermostatic and Manual Radiator Valve range Heating ontrols Thermostatic and Manual Radiator Valve range Heating ontrols New thermostatic and manual radiator valves with built-in energy saving solutions With increasing demands on specifiers and

More information

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower e x p e r i e n c e d e s I g n i n n o v a t i o n You re Guide to the Installation, Care and maintenance of Francis Pegler Memento Single Sequential Exposed Thermostatic Shower For further information,

More information

Varsity Concealed Shower System

Varsity Concealed Shower System VARSITY CONCEALED SHOWER SYSTEM Installation & aftercare instructions Please retain for future reference Varsity Dual Function Concealed Shower System Product code SVA1615 Varsity Single Function Concealed

More information

The new Terrier Belmont Thermostatic Radiator Valve range

The new Terrier Belmont Thermostatic Radiator Valve range The new Terrier elmont Thermostatic Radiator Valve range Manual Radiator Valves The new manual radiator valve range offering both traditional handwheel and lockshield styles, along with a new concealed

More information

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction TROUBLE-SHOOTING CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction Problem After installation shower only runs HOT or COLD and will not mix. Solution Hot & Cold supplies are

More information

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification Product Specification ~ Minimum Working Pressure 0.5 bar ~ Maximum Working Pressure 4.0 bar ~ Cold Water Supply Temp 4-20 c ~ Hot Water Supply Temp 55-85 c ~ Fixing Centres 150mm +/- 20mm ~ Outlet size

More information

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield IMI HEIMEIER / Thermostatic heads and Radiator valves /

More information

Franke Specialist Range Pilatus Tap

Franke Specialist Range Pilatus Tap FR100611-Pilatus Install 20/10/06 15:47 Page 3 Franke Specialist Range Pilatus Tap Installation Instructions 303 162 50 192 205 For kitchens without compromise. FR100611-Pilatus Install 20/10/06 15:47

More information

Dual Control Thermostatic Bath and Shower Mixer

Dual Control Thermostatic Bath and Shower Mixer Your Guide to the Installation, Care and maintenance of Dual Control Thermostatic Bath and Shower Mixer T555 Dual Control Thermostatic Bath and Shower Mixer - 329500 Contents Introduction... 3 Product

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

RA2000 Commercial TRVs

RA2000 Commercial TRVs RA2000 Commercial TRVs www.heating.danfoss.co.uk Danfoss Limited Ampthill Road Bedford MK42 9ER E: ukheating@danfoss.com W: www.heating.danfoss.co.uk Reception Tel: 01234 364621 Fax: 01234 219705 UK Sales

More information

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions Please retain for future reference DUAL INLINE CONCEALED VALVE SKN0201, SAS0201, SLG0202 SKN0202, SAS0205 TRIPLE INLINE CONCEALED

More information

Flow Solutions Valves for Heating System Control

Flow Solutions Valves for Heating System Control Flow Solutions Valves for Heating System Control Thermostatic Radiator Valves Manual Radiator Valves Motorised Zone Valves Domestic Heating System Valves Valves for Heating System Control Controlling domestic

More information

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE CONNECT WITH CONFIDENCE With a wealth of expertise and the broadest range of solutions and systems on the market, Pegler Yorkshire s Connect products

More information

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces. 3 Remove concealing plate KIRI Concealed Mixer Valve ABS Undo nuts (9) on both hot and cold inlets and remove filter washer KIRI VA (6) Installation Instructions & Maintenance Guide 5 Rinse filter washers

More information

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL PUTTING YOU IN CONTROL Diverse industry expertise combined with cuttingedge technological innovation mean Pegler Yorkshire s Control solutions

More information

Installation, Operating and Maintenance Guide

Installation, Operating and Maintenance Guide Installation, Operating and Maintenance Guide Part no. 780327-C Contents Exposed Exposed Shower Mixing Valve Wall Cover Plate (x2) Strainer (x2) Fixing Screw (x2) Hexagon Key wall Plug (x2) Green Limiter

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

caleffi hydronic valves page 1 of 12

caleffi hydronic valves page 1 of 12 caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series

More information

Intatherm Safe Touch Basin Tap IT1008CP

Intatherm Safe Touch Basin Tap IT1008CP Intatherm Safe Touch Basin Tap IT1008CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22 HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples

More information

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT GUARANTEE & AFTERCARE When installing or using tools, extra care must be taken to avoid damaging the finish or fitting. To maintain

More information

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning Product Specification Minimum Pressure 0.5 bar Maximum Pressure 4.0 bar Cold Supply Temperature 4-20 c Hot Supply Temperature 55-65 c 1/2" male inlets 1/2" male outlet 38c Temperature stop position Minimum

More information

HW3 Handwash Installation and Operating Instructions

HW3 Handwash Installation and Operating Instructions HW3[16]instructions 10/12/15 14:05 Page 1 HW3 Handwash Installation and Operating Instructions IMPORTANT SAFEGUARDS SPECIFICATION: HW3 RATING: 230-240V, 3000W, ~50Hz; DIMENSIONS: 170w x 190h x 80d mm;

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten. 3 Remove concealing plate KIRI Concealed Mixer Valve With Undo nuts (9) on both hot and cold inlets and remove filter washer Diverter (2 olts & Bath Fill) ABS (6) KIRI 3VDIVA 5 Rinse filter washers (6)

More information

Installation and User Guide

Installation and User Guide Singulier Deck and Wall Mounted Bath/ Shower Mixers and Wall Mounted Thermostatic Shower Installation and User Guide 10870W, 10871W, 10872W MODEL NUMBERS Important! Please quote the above model number(s)

More information

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems UPONOR Ltd Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems Reference Page(s) UPONOR Q&E PEX 2 Operating Conditions 2 Pipe Properties 2 Fittings Range 3 Radiator Heating Systems 3 H&C Water

More information

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning Product Specification Minimum Pressure 0.5 bar Maximum Pressure 4.0 bar Cold Supply Temperature 4-20 c Hot Supply Temperature 55-65 c 1/2" male inlets 1/2" male outlet 38c Temperature stop position Minimum

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

Inta City Concealed Shower Mixing Valve CT80010CP

Inta City Concealed Shower Mixing Valve CT80010CP Inta City Concealed Shower Mixing Valve CT80010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

Varsity Exposed Shower Systems

Varsity Exposed Shower Systems VARSITY EXPOSED SHOWER SYSTEM Installation & aftercare instructions Please retain for future reference Varsity Dual Function Exposed Shower System Product code SVA1712 Varsity Single Function Exposed Shower

More information

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Thank you

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

Thermostatic Concealed Shower Valve

Thermostatic Concealed Shower Valve Thermostatic Concealed Shower Valve Product may differ from image. Please retain this booklet for future aftercare reference Component Breakdown - Three Handle Valve Component breakdown Two Handle Valve

More information

Enzo Concealed Shower Mixing Valve

Enzo Concealed Shower Mixing Valve Enzo Concealed Shower Mixing Valve EZ40010CP, EZ40013CP & EZ40014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible.

More information

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic

More information

Art-Line. Absolutely Brilliant Temperature control was never so good

Art-Line. Absolutely Brilliant Temperature control was never so good Art-Line Absolutely Brilliant Temperature control was never so good Pressurisation & Water Quality Balancing & Control thermostatic Control engineering ADVANTAge art-line 16 unique decors for individualists

More information

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Airfield Industrial Estate Hixon Staffordshire ST18 0PF Deluge Thermostatic Basin Mixer IT1002CP Installation and Maintenance Instructions Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF In this procedure document we have endeavoured to

More information

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved. Innovation + Quality Valves, controls + systems Local and district heating technology for improved energy efficiency Product range Local and district heating technology The term Local and district heating

More information

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9 HEATING SERIES QUALITY BY TRADITION teide termo plus+ TECHNICAL SHEET 07/2017 IP20060 SCOPE The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating

More information

Installation Instructions Flute Tap Range

Installation Instructions Flute Tap Range Installation Instructions Flute Tap Range Models covered: FLT BAS C, FLT 1HBF C, FLT 2HBSM C, FLT TBAS C Please keep this booklet for future reference. Installer, when you have read these instructions

More information

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation BOILER ONLY INSTALLATION ALL ITEMS BLEOW SHOULD BE INCLUDED WITHIN TENDER COST OR CONSIDER WITHIN BIDDERS SUBMISSION

More information

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix

More information

Thermostatic Bar Valves

Thermostatic Bar Valves Thermostatic Bar Valves Installation & operating guide Please leave this installation & user guide with the end user CONTENTS 1. Product Variants 1 2. Important information 2 3. Cleaning & Aftercare 3

More information

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance. TAP6000 3 in Hot Tap Guarantee (UK only): 04-7 Your tap has the benefit of a comprehensive manufacturer s guarantee, details of which are shown on your Proof of Purchase Document. Any claim during the

More information

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

Technical Checklist - Plumbing and Heating Fittings - UK Sizes Technical Checklist - Plumbing and Heating Fittings - UK Sizes July 2008 NOTE: This checklist refers exclusively to fittings and accessories from our range of push-fit products for Plumbing and Heating

More information

Electronic Frost Thermostat

Electronic Frost Thermostat Electronic Frost Thermostat Cat. o. TRT031 Electronic Room Thermostat Cat. o. TRT032 TRT031 shown (TRT032 range 5-30ºC) Tamper proof cover Operating & Installation Instructions What is a room thermostat?...

More information

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets Design-Edition Design-Edition Thermostatic valves and lockshields, sets IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime

More information

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic

More information

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES - FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES - AVAILABLE FROM JULY 2014 THE TECTITE FLEXIBLE METAL SYSTEM Every customer relies on you to

More information

Instantaneous Electric Over-Sink Hand Wash Installation and User Instructions

Instantaneous Electric Over-Sink Hand Wash Installation and User Instructions 3 Flow Instantaneous Electric Over-Sink Hand Wash Installation and User Instructions IMPORTANT This Step-by-Step guide should be given to the customer after installation and demonstration. CONTENTS 1.

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

In-line thermostatic mixing valves

In-line thermostatic mixing valves In-line thermostatic Pegler Yorkshire Unrivalled quality, innovation, customer service and long-term value for money As part of the global Aalberts Industries NV Group, Pegler Yorkshire is one of Britain

More information

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER Features: Ability to pre-select water temperature thus conserving water Paraffin wax element maintains

More information

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference 11 A4000, A4100 & A4110 TREVI BLEND PARTS LIST Ref. Description 1 Lever handle complete 1a/1b Nut and washer 2 Handle cover cap 3 Shield 4 Cover plate fixing screw 5.1 Cover plate for built in version

More information

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

Section - A. Radiator Valves

Section - A. Radiator Valves Section - Radiator Valves RDITOR VLVES EXMPLE OF PPLICTION 2 6 9 3 5 7 1 4 8 2 1 Thermostat adaptable valves. 2 Lockshield valves. 3 4-way thermostat adaptable valves for one-pipe and two-pipe systems.

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

2 DESCRIPTION OF SYSTEM COMPONENTS

2 DESCRIPTION OF SYSTEM COMPONENTS 2 DESCRIPTION OF SYSTEM COMPONENTS Buderus Panel Radiators Buderus Solidoflux N panel radiators are manufactured from.049 (1.25 mm) thick steel panels. They consist of water-filled steel welded radiative

More information

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent

More information

WAL-RICH CORPORATION SINCE 1950

WAL-RICH CORPORATION SINCE 1950 STEAM SPECIALTIES ANGLE STEAM RADIATOR VALVES 0408102 1/2 1 10 0408104 3/4 1 6 0408002 1" 1 4 0408004 1 1/4" 1 2 0408006 1 1/2 1 2 - Brass - Imported STRAIGHT STEAM RADIATOR GATE VALVES 0409002 1" 1 4

More information

Instantaneous Electric Over-Sink Hand Wash Automatic no-touch model. Installation and User Instructions

Instantaneous Electric Over-Sink Hand Wash Automatic no-touch model. Installation and User Instructions 3 Sense Instantaneous Electric Over-Sink Hand Wash Automatic no-touch model Installation and User Instructions IMPORTANT This Step-by-Step guide should be given to the customer after installation and demonstration.

More information

Mercury Mixing Kit (Code: ME1053)

Mercury Mixing Kit (Code: ME1053) Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

More information

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER. METIS Riser rail kit Installation instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180531A September 2006 CONTENTS Page General installation notes 1 Main components

More information

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems. AB-PM Consistent hydronic control Continuous energy savings AB-PM automatic balancing valve for a reliable and energy-saving heating system. 1 valve needed instead of 3 for pressure, flow and zone control

More information

Infra Red Thermostatic Wall Mixer

Infra Red Thermostatic Wall Mixer Infra Red Thermostatic Wall Mixer HTMWMBCP, HTMWMMCP, HTMWMBRS & HTMWMMRS Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as

More information

CalMag Heating Pack Installation Instructions

CalMag Heating Pack Installation Instructions Calming troubled waters CalMag Heating Pack Installation Instructions Heating Filter Corrosion Inhibitor Scale Inhibitor (if applicable) Cleanser Acidic Neutraliser CalMag HF2 Filter Installation Instructions

More information

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS 1. Important information 1 2. Cleaning & Aftercare

More information

Automatic balancing valves ASV-PV (new generation) DN 32-50

Automatic balancing valves ASV-PV (new generation) DN 32-50 Automatic balancing valves ASV-PV (new generation) DN 32-50 ASV-PV DN 32-50 Description ASV whiteboard animation SMT/SI ASV valves are automatic balancing valves. Together with Danfoss presetting radiator

More information

SOLUTIONS GUIDE. For total efficiency

SOLUTIONS GUIDE. For total efficiency 2014-2015 SOLUTIONS GUIDE For total efficiency THERMOSTATIC RADIATOR HEADS Comap Thermostatic heads have been counted amongst the best sellers in Europe for decades, thanks to their high manufacturing

More information

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER! 1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based

More information

Frequently Asked Questions

Frequently Asked Questions What is a Thermostatic Radiator Valve? TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler.they should

More information

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

M07. Wunda Premium Manifold. Before you start:  Check the contents THE BRAND YOU CAN TRUST Before you start: Check the manifold box contents against the list below. Check the contents 1. 2 x Manifold end blanks 2. 2 x Manual air vent & drain cocks 3. 2x Adjustable mounting brackets 4. Manifold

More information

Flipside Handshower and Showerhead Installation and User Guide

Flipside Handshower and Showerhead Installation and User Guide 17493W-CP 15996W-CP Flipside Handshower and Showerhead Installation and User Guide MODEL NUMBERS 17493W-CP, 15996W-CP Important! Please quote the above model number(s) when ordering spares IMPORTANT INSTALLER:

More information

Puro Mini Dual Control Shower Mixer PU90010CP

Puro Mini Dual Control Shower Mixer PU90010CP Puro Mini Dual Control Shower Mixer PU90010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Dual Zone Wine Cellar

Dual Zone Wine Cellar Dual Zone Wine Cellar Instruction Booklet Model: WC-2012 IMPORTANT SAFEGUARDS Before the appliance is used, it must be properly positioned and installed as described in this manual. To reduce the risk

More information

INSTALLATION FOR THERMOSTATIC VALVES

INSTALLATION FOR THERMOSTATIC VALVES SS-TH1000 1/2 Thermostatic Valve SS-TH3000 3/4 Thermostatic Valve SS-TH2000 1/2 Thermostatic Valve with built in volume control SS-TH4000 3/4 Thermostatic Valve with built in volume control Features: Ability

More information

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions INTRODUCTION This guide provides instruction for the installation operation and maintenance of concealed touch control

More information

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

MINIATURE THERMOSTATIC VALVE

MINIATURE THERMOSTATIC VALVE SS-TH500-1/2 Features: Ability to pre-select water temperature thus conserving water Compensates for water pressure fluctuations preventing scalding Safety button at 100 F prevents accidental scalding

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

The New Caroma TMV20

The New Caroma TMV20 specify.caroma.com.au The New Caroma TMV The high performance Caroma TMV Thermostatic Mixing Valve has the capacity to service multiple outlets and features a removable cartridge for ease of service. The

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information