AIR COOLED PACKAGED CHILLER

Similar documents
CENTRAL SPLIT UNIT UNIC

AIR HANDLING UNITS. Revision AG 16-07

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

MACH N-407 Heat Pump Air-Cooled Chiller

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

.2 Section Waste Management and Disposal.

MAC N-407 Air-Cooled Chiller

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

SECTION ROTARY-SCREW WATER CHILLERS

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Liebert CSU3000 Chiller

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Advance Release September 2009

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Product Chillers A P P L I C AT I O N S

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Commercial High-Efficiency Condensing Units

MAC-120HE-03 Air-Cooled Chiller

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SECTION AIR COOLED WATER CHILLERS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION FAN COIL UNITS

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Concealed Ducted Split Series R-407C MBH

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

AIR COOLED CONDENSING UNITS IMPORTANT DESIGN FEATURES

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Call us today! (800)

WCH5**4. Product Specifications

2 shp 13 lc 1 36 t - 1 a

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

PACKAGE AIR CONDITIONER

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

Call us today! (800)

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

50TM TFF COMBINATION HEATING/COOLING UNITS

SKYPAK II, 3 Ton Series, gives you a

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

50TM COMBINATION HEATING/COOLING UNITS

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Call us today! (800)

48TF GAS HEATING/ ELECTRIC COOLING UNITS

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

PAJ3. Product Specifications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

R4H4. Product Specifications

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

1.1 This section applies to air handling units for HVAC Systems.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

C. Samples for Initial Selection: For units with factory-applied color finishes.

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SKYPAK II, 3 Ton Series, gives you a

Commercial High-Efficiency Condensing Units

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Construction Standards Page

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

48TM GAS HEATING/ELECTRIC COOLING UNITS

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

SECTION ROOFTOP REPLACEMENT AIR UNITS

R4H4. Product Specifications

Split System Cooling Product & Performance Data

REFRIGERATION PRODUCTS

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

EHH SERIES DRAW THROUGH FAN COILS CFM

Transcription:

AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products and facility. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be described herein. Please contact our customer department for specific information on the current design. Consultancy & Design Our Engineering Dep t is always available to solve special requirements, investigating the client situation and using the most sophisticated available tools. The knowledge and the precious experience of our Engineers is supported by the most advanced computerized calculations and design programs. Revision AG 16-07 COOLER is equipped to produce Air Cooled Packaged Liquid Chillers which conform to standards set by advancing technologies and use the most sophisticated American and European materials. APPLICATIONS. Perfectly convenient for Apartments, Offices, Small and Large Industries, Hospitals, Hotels, Sports Halls and Mini or Maxi Store. Units are especially patterned to meet modern design requirements and are suitable for vertical air flow. Standard COOLER Air Cooled Packaged Liquid Chillers have the following characteristics: CAPC Models: from 30 up to 502 Ton (from 87,000 up to 1,500,000 Kcal) = All Units can be custom tailored on request = The COOLER Air Cooled Packaged Liquid Chillers is a packaged unit completely factory assembled on a stiff steel structure with panels made from heavy gauge zinc galvanized or zinc or primered sheets with a baked fine enamel finish, making them weather resistant and suitable for outdoor installations. All piping and electrical wiring are ready for external field connection. Units are factory tested at 28 bar (400 psig), flushed and Freon charged. Compressors have the initial oil charge. OPERATIONAL TEST are performed to verify that all circuits and safety devices are operating properly with large margins of security. NOISE TEST are also performed to verify that body panels, fans and motors, air and liquid flow, etc, shall operate according to the highest standard of performance.

CONTROLS CABINET A weatherproof cabinet harbours all indicator devices, switches, lamps, as well as most of the relays, contactors, circuit breakers, pressure gauges, electric terminals, etc. Power Compartment controls include: -Refrigerant high pressure cut-off manual reset. -Compressor motor contactors. -Refrigerant low pressure cut-off. -Fan motor contactors. -Electronic digital Thermostat chilled liquid cycling. -Fan motor circuit breaker(s). -Freezestat low liquid temperature. -Power terminal blocs 230 & 400V 50Hz. -Restart compressor time delay. -Separate 230V control circuit terminal block (for -High and low voltage protection. field wiring). -Phase failure protection. -Compressor staging relays. -Fan cycling controls pressure actuated (optional). -Compressor crankcase heater relays. -Compressor staging (optional). -ControI circuit terminals. -Liquid flow control (optional). -Control circuit breaker(s). -Soft start electronic control (optional). -Field auxiliary control terminals. -Micro-processor programmable controller Safety and Operating Controls include: (optional). -System on-off switch. -Oil pressure cut-off manual reset. PRESSURE GAUGES. Factory mounted suction and discharge pressure gauges for each refrigerant circuit and an oil pressure gauge for each compressor are provided. Each gauge is supplied with its own manual shutoff valve. FAN CYCLING MEDIUM AMBIENT CONTROL. Fans are automatically cycled in response to gas pressure to maintain adequate head pressure and allow compressor start at 30 F ambient (optional). COMPRESSOR CIRCUIT BREAKERS OR COMPRESSOR FUSE BLOCKS. Either companion trip, ambient compensated circuit breakers with built-in three leg overload protection; or three leg fuse blocks, with time delay (dual element) fuses, provide additional protection for each compressor (option). REFRIGERANT PIPING. All circuits are made of brazed seamless copper tubes. Refrigerant circuits include: -Thermal expansion valve. -Manual liquid line shut-off valve. -Permanent charging ports. -Automatic liquid line shut-off valve. -Liquid receiver. -Refrigerant filter-drier. -Suction accumulator (heat pump). -Liquid sight glass/moisture indicator. -External muffler (optional). -Liquid line solenoid valve. DISCHARGE LINES Formed of pre-bent tubing or elbow fittings with long radius bends to eliminate vibrations and minimize pressure drops.

SUCTION LINES Designed for minimum friction loss and proper oil return. All suction lines are insulated with flexible closed cell hoses. CONDENSER COILS Made of seamless copper tubes expended onto aluminum fins. Copper fins and lacquered or anodized fins are also available on request. Size of pipes, number of rows, face area, etc., are in accordance with the compressor capacity, evaluated as per ARI standard code. CONDENSER FANS are direct driven propeller type. Blades are statically and dynamically balanced and run at low RPM for quiet and vibration-free operation. Fan blades are protected by heavy gauge fan guards. On request a centrifugal forward curved type blower can be supplied, statically and dynamically balanced, with parts made of galvanized steel sheet, driven directly or by belts. FAN MOTORS are permanent split capacitor induction type or three phase type with inherent thermal protection. Motors have permanently lubricated ball bearings and are of water proof enclosed type designed for service at ambient temperatures up to 60 C, with additional moisture protection, making them suitable for outdoor conditions. Motors are suitable for horizontal and vertical working positions, and run at low speed, producing low noise, and are manufactured in accordance with most European and American electric norms. COMPRESSORS. COPELAND semi hermetic compressors are used, refrigerant gas cooled type with built-in thermal protection, crankcase heater and large voltage capacity, suitable for 50 and 60 Hertz application. Each compressor is mounted on isolator pads and connected via flexible vibration absorbers to the coil copper tubing to reduce vibration transmission to the rest of the unit. Compressors are designed for high energy efficiency, compact construction, rugged reliability, long-life and are maintenance free. Compressors can be disassembled in the field for service. Oil level sight glass is standard. Oil electronic pressure control cuts the power to the motor when the pressure drops below acceptable limits. Larger compressors have a built-in relief valve between suction and discharge lines which will open if the maximum permissible pressure differential is reached. EVAPORATOR is a shell and tube type cooler. The construction is in accordance with most American and European Norms and codes (TEMA RINA ISPESL TUV - SDM). Weather and corrosion resistant suitable for outdoor applications. Gas tubes are made of seamless copper tubes and are tested at 28 bar (400 psig). Shell have standard trade water outlets for thermostat, air vent, drain and water main stream. This liquid cooler is also suitable as liquid heater in Heat pump mode. ECONOMIZER shell and tube type is available on request, it improves the chilling capacity of the unit, by precooling the chiller, and preheating the gas at the compressor suction line. ELECTRIC junction board shall be color coded and wires identified for easy field connections and maintenance. It includes compressor and fan motor contactors, thermal overload protection, high/low voltage and phase failure protectio, pressure protection cut of relay with compressor restart delay, compressor crankcase heater relay, circuit fuse beakers, and coded terminals.

WATER PUMP can be included as an accessory according to client specifications. Thermometers and pressure gauges on the liquid inlet and outlet can be provided on reques. Air vents are standard. INSTALLATION of the unit is easy because it needs only to be connected to the outside utilities: liquid line and electric power supply. ELECTRIC BOARD with remote control and functional display with duty lamps and alarms can be supplied. 24 VAC transformer ready to connect electronic thermostat (optional). ACCESS to all internal parts for cleaning or maintenance, needs loosening of a few screws only to remove any pane. All parts can be easily removed & replaced. COOLER Service Department is always available to serve our customer and ready to solve any problem. COOLER Project Department is ready to study cases and to supply the most economic, yet feasible solutions. QUALITY GUARANTE UNIC sal COOLER guarantees contractual free maintenance, availability of all parts and components, and qualified field technicians to carry out the maintenance requirements. UNIC sal Company is ISO 9001:2015, DQS-UL, IQNet and CE Certified.