Multi-Channel Gas Detector Monitoring Unit GMS

Similar documents
SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

2-Channel Smoke Detector SD - 110

SS-100. Pyrometer. Temperature Range: 800~2400

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

SCAN20 Series Gas Detection Controller

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Tips how to use the MAS Web tool

PRESENTATION OF DAEWOO GAS BOILER

Gas Detection System TOX ALARM DG2000-Garage

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Touch Screen 1 loop Addressable Fire Alarm Panel

Process & TeMPerATUre UniversAl input DigiTAl MeTers

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Danfoss gas detection unit Type GD Heavy Duty

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Temperature-Relay TR210

REPEATER FS5200R OPERATION MANUAL

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof - Suction Type - DA- 800

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

BUILDING DISTRIBUTOR CCU-BS

CSP-204 CSP-208 CSP-104 CSP-108

System 57. An advanced World of intelligent gas detection system management

USER S MANUAL HSC-14/18/24/24A

Two-Channel Gas Controller

Installation Manual Tracker 221

PTE0705 Electric Fence Monitor

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

SUPERINTEND VRE-08/16/32/64

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

Danfoss gas detection units

IGD.CO.UK

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

Pioneer-R16 Gas Monitor Operator s Manual

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

PARTICULATE EMISSION MONITORING

PROGRAMMING MANUAL. CM (Micro v. 1.0)

XRSuper6. User s Guide

INSTALLATION AND OPERATING INSTRUCTIONS

BT-500. Infant Incubator. BT-500 Infant Incubator

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Products and performance

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

SCAN200E USER S MANUAL

Addressable Fire Alarm Control System 2100 series

Process Alarm Module RTA 421

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

USER MANUAL FOR OPERATING SYSTEM

SEC 2000 Millenium Infrared Gas Detector

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Carbon Monoxide Transmitter

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

On the job around the clock 24/7: Fire detection systems

Intelligent addressable fire alarm control panel

Electric Coils. Blower Coils. Product Information

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

RAE Systems Systems. User Presentation. October Protection Through Detection

UNI-TROL TM GAS CONTROLLER

Remote Display Alarm Indicator for Oxygen monitor

DATAssure. Laboratory wireless alarm & monitoring system

Industrial Grade Gas Detection


Model 9010 and 9020 Monitoring Systems

APPLICATION DATA SHEET

Operations Manual TS400. Test Station for G450/G460 Gas Detector

System 57. An advanced world of intelligent gas detection system management

INTREPID Perimeter Intrusion Detection System

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

1.7. Insulation fault evaluators EDS460/490 EDS461/491

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Model 9010 and 9020 Monitoring Systems

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Annunciator Unit SACO 16 D1. Product Guide

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

Ultrasonic Switches. Features & Benefits

MC-5 Series Micro Processor Temperature Controller

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Gasmonitor+ Installation, Operation and Maintenance Manual

Annunciator unit. Application

CO2 Monitor Operating Instructions

Technical Manual. Level Alarm Unit CARLA & WIDS

Operating Instructions

Fire Control Panel FS4000

RS485 MODBUS Module 8AI

(Cabinet Automatic Fire Extinguishing System)

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Installation Instructions

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

WIO 200B and WIOI200B Water in oil sensor

Pump-Down Controller MODEL 4052

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

WS INSTRUCTION MANUAL LED WEATHER STATION WITH RADIO CONTROLLED CLOCK AND ALARM

Transcription:

Multi-Channel Gas Detector Monitoring Unit GMS - 2000 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail: sales@gasdna.com Web: www.gasdna.com page 1

CONTENTS Introduction page 3 Features page 3 Specification page 4 Keys & LEDs page 5 Menus page 6 Alarm Test page 6 Programming page 7 Wiring page 8 ~ 9 Dimensions page 9 page 2

[Introduction] GMS-2000 is multi-channel gas alarming unit to monitor gas leakages from more than one gas detectors simultaneously. GMS-2000 is composed of one alarming unit & more than one receiving units. While each receiving units in GMS-2000 receive density signals from external gas detectors, when the density becomes higher than alarm value, receiving units automatically give signal to alarming unit to sound alarm. GMS-2000 transmits the relay output and standard current output signal 4-20 ma to various controllers such as PLC, DDC, recorders, and computers for composition of integrated gas monitoring system. [Features] Centralized gas monitoring is available by connection with more than one gas detectors. Receiving 4-20 ma analogue continuous signals from more than one gas detectors simultaneously and displaying the digital signals accurately by built-in high resolution A/D converter. User programming alarm range, alarm delay time, and so on, by built-in micro processor. Bar graph displays the alarming density for maximum visual effect. Built-in high resolution D/A converter for accurate transmission of 4-20 ma standard current output signal to external controllers (PLC/DDC). High/low relay output for interlocking with external devices such as fan. Robust aluminum alloy casing & frame. page 3

[Specification] Division Alarming unit (Power unit) GMS-2000 Receiving unit Product structure Control structure. Expansion structure. DIN TYPE DIN TYPE Alarm:Indicator1:1~64 Indicator: Sensor = 1:1 Slide Card Type Input power AC 230V/60Hz Output power DC 24V(250 ma ) Input signal Output signal Density indicating Power indicating 4~20mA DC/F.S 4~20mA DC/F.S, RS-485(Option) F.N.D Display %LEL( 주연성 ),%( 산소 ), PPM( 독성 ) Power supply indicating POWER LED(GREEN) Alarm indicating Alarm method Alarm density Alarm delay time Alarm lifting ALARM LED(RED) Seeing ALARM LED On/Off Hearing Buzz(higher than 80dB ) Manual and automatic returning Low Alarm - LOW LED(RED) High Alarm HIGH LED(RED) Trouble Alarm FAULT LED(YELLOW) Seeing Alarm LED On/Off HIGH/LOW 2 step Alarm density set by user. 0~99seconds, setting by user Alarm output Operating temp./humidity Exterior structure. SPDT RELAY output for HIGH/LOW 2 steps SPDT RELAY output for FALULT alarm -20 ~ 50, 5 ~ 95%RH(Non-Condensing) 19 (3U) Unit - Aluminum, Outer box of system - Metal Case Output option RS-485 page 4

[Keys & LEDs] Power unit(alarming unit) 1Buzz: When alarming, buzz sound of more than 80 db is given. 2POWER LED: indicates main power supplying condition.(normal-on, Power failure-off) 3ALARM LED: By blinking when alarming, alarm is visually indicated 4 RESET: continuously blinking. After alarm is recognized, alarming sound is stopped. At this time, ALARM LED is Receiving unit(indicator) 1FND: Received density signal is indicated by digital.(3 digit number) 2POWER LED: Power supplying condition of INDICATOR is shown.(normal-on, Power failure- OFF) 3FAULT LED: It blinks when the line is cut between INDICATOR and DETECTOR. 4HIGH ALARM LED: It blinks when the density more than setting of HIGH ALARM is detected. 5 LOW ALARM LED: It blinks when the density more than setting of LOW ALARM is detected. 6 ENT KEY: Push it when the input value is stored at the time Program menu is set. 7 UP KEY: When Program menu is set, the increased value is made by the key. 8DOWUN KEY: When Program menu is set, the decreased value is made by the key. 9MODE KEY: Program menu setting mode is selected. 10 RESET: alarming of the INDICTOR 의 is manually returned.(when alarming manual release function at menu is selected). 11BAR graph: Received detect density equally divided by 20 is indicated by a bar graph. page 5

[Menus] Menu d.po L.sc H.sc L.AL L.dt H.AL H.dt S.dt Explanation Position of Decimal point of digital density indication is decided.(ex. 20.0ppm or, 200ppm) 4mA setting menu compared to Full Scale. 20mA setting menu compared to Full Scale. LOW alarming value setting menu. LOW alarming delaying time setting menu.(0~99 seconds) HIGH alarming value setting menu. HIGH alarming delaying time setting menu (0~99 seconds). When initial power is supplied, system initiating time (0~99seconds) Alarm clearing function selection menu - Manual/Auto clearing selection A.rE 1 Auto clearing setting menu 0 Manual clearing setting menu [Alarm Test] TEST : Alarm operating or nor is tested * Setting method: Push (UP) and (DOWN) continuously and simultaneously. During pushing 2 buttons continuously, the value is continuously increasing, when it arrives at the peak within the detectable range, it stops. When the value passes through the set value, LOW and HIGH alarm automatically sounds. page 6

[Programming] Order Menu Selection/Pass Setting of menu value Storing button 1) If entering into the menu setting mode by pushing (MODE)Key, the first menu(d.po) appears, and if pushing (MODE)Key repeatedly, following menu appears in order, FND number on the left side blinks continuously to show the setting status. 2) At this time, Selection/Pass is determined by (ENT)/(DOWN)Key. 1 d.po (ENT)/(MODE) Position of decimal point is determined with (UP) or (DOWN) Key (ENT) 2 L.sc (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 4 H.sc (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 5 L.AL (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 6 L.dt (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 7 H.AL (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 8 H.dt (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 9 S.dt (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 10 A.rE (ENT)/(MODE) Value is set with (UP) or (Down) Key. (ENT) 11 End If all the above menus are passed in order, they will be automatically transferred into common mode. If the precedent menu is moved to the next menu without setting value, push the (MODE) Key. If one menu value is set and stored, it will be automatically transferred into common mode. (1 menu selection/menu setting mode 1 time) EX) L-AL setting: 1) If (MODE) Key is pushed 4 times repeatedly, L.AL menu appears. 2) Value is set with (UP) or (Down) Key. 3) If (ENT) Key is pushed, value is stored and automatically transferred into common mode. page 7

[Wiring] monitoring unit <Channel terminal> Note: Every channel has two terminals each of FAULT, HIGH, & LOW. <External terminal> Note: 24V(+), GND(-), analogue output(ma), earth(e) page 8

[Wiring] Gas detector Receiving unit Detector Indicator [Dimensions] GAS ALARM CONTROL SYSTEM ( 주) 주주주주주주 page 9