PattonPak Stream Condensing Units

Similar documents
FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Kramersaver Air Cooled Condensing Units

Specifications and Performance S2H

Condensing Units CUS 15-60

500 EX Fusion Compressor Series

Kirby Commander Condensing Unit

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

horizontal air discharge outdoor discus condensing unit

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

ENTHALPY HERMETIC CONDENSING UNITS

Accumulators - Suction Line

Owners Manual Refrigerated Air Dryer MHT SERIES

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

WCH5**4. Product Specifications

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

ENTHALPY TD SERIES CONDENSING UNITS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Commercial High-Efficiency Condensing Units

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Optyma Slim Pack Condensing Units

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Air-Cooled Condensing Units with Compact Screw Compressors

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MACH N-407 Heat Pump Air-Cooled Chiller

ENTHALPY TD SERIES CONDENSING UNITS. Enthalpy. Semi Hermetic TD Series Condensing Units (Medium / Low Temperature)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Kirby Drop-In Packaged Refrigeration Units

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

RP8.1Y (ERRATA 1) (202) 2 of 8

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

R4H4. Product Specifications

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

DANFOSS OPTYMA PLUS INVERTER UNITS

N4H4. Product Specifications

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

DRYMAX DRYMAX DRYMAX DRYMAX

30GN FLOTRONIC II AIR-COOLED CHILLERS

3-22 HP CONDENSING UNITS Technical Guide

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Tube-in-tube heat exchanger Type HE

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

MAC N-407 Air-Cooled Chiller

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Otherwise, you can continue reading the file on the following pages.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Technical Data Ducted Three Phase Split System Air Conditioner

MAC-120HE-03 Air-Cooled Chiller

TECHNICAL SPECIFICATIONS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

DROP-IN + PLUG-IN UNITS

PRODUCT RANGE: ROOFTOP PACKAGE

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

TECHNICAL SPECIFICATIONS

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

AIR COOLED CONDENSING UNIT

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

16 SEER TWO-STAGE AIR CONDITIONERS

RSG16**S1M. Split System Air Conditioner 16 SEER

Installation, Start-Up and Service Instructions

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

HERO SERIES-DC INVERTER HEAT PUMPS

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

EQUIPMENT SNOW DOMES / SKI DOMES

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

30GT FLOTRONIC AIR-COOLED CHILLERS

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

SKYPAK II, 3 Ton Series, gives you a

13 SEER CONDENSING UNITS

Self-Contained Reverse Cycle Air Conditioners

SKYPAK II Heating & Cooling Self Contained Packages

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

COMPRESSOR TECHNICAL OVERVIEW

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

CoolSpot Engineering Guide

[U] Serie MOV. Manual de Ingeniería

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Product Data. Efficiency. S S Reliability

Transcription:

PattonPak Stream Condensing Units www.pattoz.com

Condensing Units Latest technology, high efficiency Copeland Stream Compressors. Supplied c/w : Copeland Core Sense, HP/LP, Crankcase Heater, Oil Separator, Liquid Receiver, Liquid Line Drier & Sightglass, Suction Accumulator, Fully wired c/w main isolator in ColourBond housing. All models include fan cycling pressure switch. All condenser coils supplied with Patton Coat fin and coil protective coating. PSC STREAM 1300-2000 13 20 CAPACITY (Watts) @ 32 C Ambient Refrigerant Evaporating Temp C -35-30 -25-20 -15-10 -5 0 5 10 PSCL1300 13.0 R134a - - - 13320 17000 21380 26110 31540 37560 44230 R449A - 13490 16470 19990 24280 29050 34390 40280 - - R404A 12330 15250 18800 22810 27320 32230 37620 - - - PSCL1500 15.0 R134a - - - 16100 20220 25320 30800 37470 44550 - R449A - 17290 21090 25320 30680 36820 43570 50120 - - R404A 14940 18420 22640 27440 32640 38430 44800 - - - PSCL2000 20.0 R134a - - - 17670 22400 27540 33370 40000 47490 55710 R449A - - 22030 27500 33250 39580 45920 54260 - - R404A 16630 20320 24830 29740 35190 41130 46610 - - - PSCM2000 20.0 R134a - - - 14430 18170 22580 27830 33460 40390 47700 PATTONPAK PSC STREAM 1300-2000 R449A - - 18110 22400 27740 33970 41110 49180 58240 - R404A 12420 15930 20220 24540 29990 35370 41270 47760 54810 - www.pattoz.com

DIMENSIONS 400MM CLEARANCE 952 (MTG CTRS) 946 (UNIT WIDTH) 990 (OVERALL WIDTH) PSCL1300 PSCL1500 PSCL2000 PSCM2000 PLAN VIEW VERTICAL AIR FLOW AT THE REAR OF THE UNIT 1150 (OVERALL HEIGHT) 1022 (UNIT HEIGHT) 122 (ELEC INPUT 1) 659 (ELEC INPUT 2) 704 (LIQUID) 779 (SUCTION) NTS (mm) 570 (MTG CTRS) 570 (MTG CTRS) 1322 (UNIT LENGTH) TECHNICAL DATA MODEL COMPRESSOR CONDENSER RECEIVER CONNECTIONS Voltage RLA LRA Airflow (I/sec) No. (1) Fan Motors Watts Capacity (2) Suction Liquid Noise Level (dba) (3) Wgt PSCL1300 13.0 4MF-13X 380-420/3/50 30.8 105.0 CPK1300 7050 2 x 630 2500 5.0 20.0 1-5/8" 7/8" 67 420 PSCL1500 15.0 4ML-15X 380-420/3/50 35.4 156.0 CPK1500 6730 2 x 630 2500 5.0 20.0 1-5/8" 7/8" 68 420 PSCL2000 20.0 4MM-20X 380-420/3/50 39.0 175.0 CPK1500 6730 2 x 630 2500 5.0 20.0 2-1/8 7/8" 68 420 PSCM2000 20.0 4MA-22X 380-420/3/50 36.3 175.0 CPK2050 6630 2 x 630 2500 5.0 20.0 1-5/8" 7/8" 69 460 NOTES: 1. 630mm Cond Fans - 380-420/3/50 2. R404A pump down capacity @ 80% full for 32 C liquid temp. 3. All noise level ratings are free field based at a distance of 3.0 mtrs from source and are given as a guide only. 4. Electrically complies to AS/NZS 60335.2.89 : 2002 + A1-A3 (Selected clauses) The company reserves the right to make specification changes without notice. NZ 16/11/2018 www.pattoz.com

Condensing Units Latest technology, high efficiency Copeland Stream Compressors. Supplied c/w : Copeland Core Sense, HP/LP, Crankcase Heater, Oil Separator, Liquid Receiver, Liquid Line Drier & Sightglass, Suction Accumulator, Fully wired c/w main isolator in ColourBond housing. All models include electronic fan speed control. All condenser coils supplied with Patton Coat fin and coil protective coating. PSCL STREAM 2200-4000 22 40 CAPACITY (Watts) @ 32 C Ambient Refrigerant Evaporating Temp C -35-30 -25-20 -15-10 -5 0 5 10 PSCL2200 22.0 R134a - - - - 24570 30510 37330 45230 54060 64160 R449A 15980 20850 26210 32330 39230 46920 - - - - R404A 19020 23190 28360 34760 41290 48550 - - - - PSCL2500 25.0 R134a - - - - 26970 33620 42020 51000 61220 71850 R449A 16750 22010 28230 34880 42410 50800 - - - - R404A 20810 25520 31890 38560 45880 54160 - - - - PSCL3000 30.0 R134a - - - - 31660 39880 48940 58450 70110 82110 R449A 19950 26250 32950 40290 48450 56690 - - - - R404A 24870 30440 37270 44920 53450 61810 - - - - PSCL3500 35.0 R134a - - - - 36350 45080 55060 66520 79560 94150 PATTONPAK PSCL STREAM 2200-4000 R449A 22620 29230 37170 45510 54730 64870 - - - - R404A 28150 34290 42740 51590 61470 70990 - - - - PSCL4000 40.0 R134a - - - - 39980 49470 61420 74380 87780 104220 R449A 23750 31890 40740 50920 62610 74620 - - - - R404A 31170 38230 47740 57750 68930 79890 - - - - www.pattoz.com

DIMENSIONS 1768 (OVERALL WIDTH) (x4) 500 FANS PSCL2200 500MM CLEARANCE 500MM CLEARANCE ELECTRICAL INLET POWER SUCTION LIQUID SIGHTGLASS 1092 (UNIT HEIGHT) 1227 (OVERALL HEIGHT) (MOUNTING CENTERS) (MOUNTING CENTERS) 1768 (OVERALL WIDTH) 2186 (MOUNTING CENTERS) 2232 (OVERALL LENGTH) SIDE ELEVATION (x4) 630 FANS PSCL2500 PSCL3000 PSCL3500 PSCL4000 600MM CLEARANCE 600MM CLEARANCE ELECTRICAL INLET POWER SUCTION LIQUID SIGHTGLASS 1092 (UNIT HEIGHT) 1227 (OVERALL HEIGHT) NTS (mm) (MOUNTING CENTERS) (MOUNTING CENTERS) 2828 (MOUNTING CENTERS) 2874 (OVERALL LENGTH) SIDE ELEVATION TECHNICAL DATA MODEL COMPRESSOR (1) CONDENSER RECEIVER CONNECTIONS Voltage RLA LRA Airflow (I/sec) No. (2) Fan Motors Watts Capacity (3) Suction Liquid Noise Level (dba) (4) Wgt PSCL2200 22.0 4MT-22X 380-420/3/50 44.5 175.0 CPK1000_2 7164 4 x 500 2180 9.6 28.2 2-1/8" 1-1/8" 68 810 PSCL2500 25.0 4MU-25X 380-420/3/50 51.9 199.0 CPK1200_2 14760 4 x 630 5000 10.0 28.2 2-1/8" 1-1/8" 71 865 PSCL3000 30.0 6MM-30X 380-420/3/50 59.7 255.0 CPK1200_2 14760 4 x 630 5000 10.0 36.3 2-1/8" 1-1/8" 73 900 PSCL3500 35.0 6MT-35X 380-420/3/50 67.3 255.0 CPK1300_2 14100 4 x 630 5000 10.0 48.4 2-1/8" 1-1/8" 73 900 PSCL4000 40.0 6MU-40X 380-420/3/50 75.8 304.0 CPK1500_2 13460 4 x 630 5000 10.0 48.4 2-1/8" 1-1/8" 73 900 NOTES: 1. Stream compressors require Demand Cooling (DC) for application within the shaded zone (refer capacity). 2. 500mm Cond Fans - 220-240/1/50 630mm Cond Fans - 380-420/3/50 3. R404A pump down capacity @ 80% full for 32 C liquid temp. 4. All noise level ratings are free field based at a distance of 3.0 mtrs from source and are given as a guide only. 5. Electrically complies to AS/NZS 60335.2.89 : 2002 + A1-A3 (Selected clauses) The company reserves the right to make specification changes without notice. NZ 10/11/2017 www.pattoz.com

Condensing Units Latest technology, high efficiency Copeland Stream Compressors. Supplied c/w : Copeland Core Sense, HP/LP, Crankcase Heater, Oil Separator, Liquid Receiver, Liquid Line Drier & Sightglass, Suction Accumulator, Fully wired c/w main isolator in ColourBond housing. All models include electronic fan speed control. n n All condenser coils supplied with Patton Coat fin and coil protective coating. PSCM STREAM 2200-4000 22 40 CAPACITY (Watts) @ 32 C Ambient Refrigerant Evaporating Temp C -25-20 -15-10 -5 0 5 PSCM2200 22.0 R449A 18110 22790 28640 34990 42330 50590 59870 R407F - 22280 28230 34680 41940 50220 59470 R404A 20610 25010 30540 36720 42820 49570 57940 PSCM2500 25.0 R449A 21110 26420 32400 39880 47610 56390 66080 R407F - 25910 32840 40290 48720 58200 68910 R404A 23750 29070 35600 42290 50530 58770 67830 PSCM3000 30.0 R449A 24070 29520 36210 44350 52880 62420 73030 R407F - 28340 35740 43700 52630 62730 74010 R404A 26810 32400 39270 46100 54550 62830 71870 PSCM3300 33.0 R449A 26520 32990 40390 49670 59280 70180 82230 R407F - 32210 39860 49370 59400 70770 83460 R404A 29700 36600 44450 52470 62340 72130 82760 PSCM3500 35.0 R449A 29780 37110 45550 55060 66850 79090 92760 PATTONPAK PSCM STREAM 2200-4000 R407F - 36150 44450 55180 66500 79380 93780 R404A 33190 41000 49940 58980 68870 81360 93470 PSCM4000 40.0 R449A 36620 44880 54880 66970 79600 93530 108940 R407F - 43330 53860 66730 80340 95680 111080 R404A 39920 48470 58960 69690 81560 94490 108360 www.pattoz.com

DIMENSIONS 1768 (OVERALL WIDTH) (x4) 500 FANS PSCM2200 500MM CLEARANCE 500MM CLEARANCE ELECTRICAL INLET POWER SUCTION LIQUID SIGHTGLASS 1092 (UNIT HEIGHT) 1227 (OVERALL HEIGHT) (MOUNTING CENTERS) (MOUNTING CENTERS) 1768 (OVERALL WIDTH) 2186 (MOUNTING CENTERS) 2232 (OVERALL LENGTH) SIDE ELEVATION (x4) 630 FANS PSCM2500 PSCM3000 PSCM3300 PSCM3500 PSCM4000 600MM CLEARANCE 600MM CLEARANCE ELECTRICAL INLET POWER SUCTION LIQUID SIGHTGLASS 1092 (UNIT HEIGHT) 1227 (OVERALL HEIGHT) NTS (mm) (MOUNTING CENTERS) (MOUNTING CENTERS) 2828 (MOUNTING CENTERS) 2874 (OVERALL LENGTH) SIDE ELEVATION TECHNICAL DATA MODEL Voltage RLA LRA Airflow (I/sec) COMPRESSOR CONDENSER RECEIVER CONNECTIONS Noise No. (1) Fan Motors Watts Capacity (2) Suction Liquid Level (dba) (3) Wgt PSCM2200 22.0 4MA-22X 380-420/3/50 36.3 175.0 CPK1000_2 7164 4 x 500 2180 9.6 28.2 1-5/8" 1-1/8" 68 810 PSCM2500 25.0 4MH-25X 380-420/3/50 41.6 199.0 CPK1200_2 14760 4 x 630 5000 10.0 28.2 2-1/8" 1-1/8" 71 865 PSCM3000 30.0 4MI-30X 380-420/3/50 46.6 221.0 CPK1200_2 14760 4 x 630 5000 10.0 36.3 2-1/8" 1-1/8" 73 900 PSCM3300 33.0 4MJ-33X 380-420/3/50 52.9 221.0 CPK1300_2 14100 4 x 630 5000 10.0 36.3 2-1/8" 1-1/8" 73 900 PSCM3500 35.0 4MK-35X 380-420/3/50 61.1 255.0 CPK1500_2 13460 4 x 630 5000 10.0 48.4 2-1/8" 1-1/8" 73 900 PSCM4000 40.0 6MI-40X 380-420/3/50 71.4 304.0 CPK2050_2 13260 4 x 630 5000 10.0 48.4 2-1/8" 1-1/8" 73 900 NOTES: 1. 500mm Cond Fans - 220-240/1/50 630mm Cond Fans - 380-420/3/50 2. R404A pump down capacity @ 80% full for 32 C liquid temp. 3. All noise level ratings are free field based at a distance of 3.0 mtrs from source and are given as a guide only. 4. Electrically complies to AS/NZS 60335.2.89 : 2002 + A1-A3 (Selected clauses) The company reserves the right to make specification changes without notice. NZ 16/11/2018 www.pattoz.com

The company reserves the right to make specification changes without notice. 16/11/2018