INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Similar documents
Installer Guide smart connect

Installer Guide smart connect

PRODUCT DIAGRAM PACKAGE CONTENTS

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

PRODUCT DIAGRAM PACKAGE CONTENTS

1126 Series Ceiling Mount PIR Motion Detector

ADC-T2000. Smart Thermostat v1.5

Wireless High Bay Sensor (WHS100) Installation Instructions

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

W-505 W-505 CONTROL BRACKET INSTALLATION W-505 INSTALLATION. CAUTION! Do not use with wall dimmer or rocker switch.

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Universal Fan and Light Remote Control

Concert Breeze s Manual

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Model: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock

Projection Alarm Clock

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

1125 PIR Motion Detector

Blueair C User Manual

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Atomic Digital Wall Clock

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

HSD-200Z Z-Wave Motion Sensor

Wireless Home Appliance Timer Remote Control Kit

Zigbee Smoke Sensor PSG03

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Installation and ZONES: Operation Manual. Model: ON STI-34108

Digital Cooking Thermometer models / 00282

Powerley Thermostat. Installation & Operation Guide

Responder IV Wireless Bed Interface User s Guide

Thermometer model 02059

Mood Light and Nature Sound Alarm Clock

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Wireless Outdoor Air Reset Adaptor PN:

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Blueair Classic. User Manual - 500/600 series

Ion Gateway Cellular Gateway and Wireless Sensors

Table of Contents. What to Expect with. Mounting Options. Tools Needed

40 Built-in Electric Fireplace Operating and Installation Instructions

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

programmable control model installation and setup guide M /11/ Hunter Fan Company

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

DCH-Z110/Z120. Function Compare DCH-Z110/DCH-Z120. Add to/remove from Z-Wave TM Network

Door/Window Sensor Installation Instructions

Digital Refrigerator/Freezer Thermometer model 00986

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Slim Multisensor PST02-A/B/C

I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus

RF2352A, HC2351AC (Discontinued), HC2352AC

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

CONNEX Smart Thermostat CST R00

180 Degree Ceiling Mounted Occupancy Sensors

Touchscreen Comfort Control

838 CAR ALARM SYSTEM USER S MANUAL

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

Honeywell Temperature & Humidity Sensor with LCD

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Wireless ShatterPro Acoustic Sensor Installation Instructions

EW 40 Wireless Fan Control

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

Getting Started with

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

OPERATING MANUAL CUSTOMER SERVICE NO

Badge Reader BR Installation Guidelines. Product Summary

2017 EcoFactor, Inc.

Little Anne. Important Product Information

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Pet Immune SAW PIR Motion Sensor

WIRELESS COLOR FORECAST STATION

HomeLink Wireless Control System

NetworX NX-548E Receiver Installation Instructions

Driveway Alarm INSTALLATION MANUAL.

IN-OUT Thermometer with Cable Free Sensor and Clock

IMPORTANT SAFETY INFORMATION:

Slim Multisensor PST02-A/B/C

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

ShockLink. Important Product Information.

SUNRISE ALARM CLOCK. With Multicolor LED Lights HME040187N. Before using your Sunrise Alarm Clock, please read this manual.

888 TWO WAY CAR ALARM SYSTEM USER S MANUAL

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

DeLaval activity meter system Instruction Book

Wireless Weather Station. Table of Contents

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Transcription:

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Z-Wave DIMMER BASICS The Kichler Z-Wave full range dimmer is designed to allow your Kichler Design Pro LED fixtures to communicate with one another as well as to be added to an already existing Z-Wave network. To begin using Z-Wave technology, it is helpful to understand that each Z-Wave dimmer communicate with each other using a low power radio transmitter and receiver. Large metal objects, house wiring, walls, furniture, refrigerators, microwaves and similar items can interfere with communication between the modules to reduce the range or even prevent communication. Therefore, placement of the Z-Wave dimmers is very important. It is also important to understand that a Z-Wave network can have only one primary controller. The primary controller establishes the network identification number so that your network will not operate your neighborʼs network and viceversa. The 12387 Z-Wave dimmer works with Z-Wave products from different vendors and product categories as part of the same network. This product is a listening node and will act as a repeater in a Z-Wave network. It will perform the repeater function with Z-Wave products from Kichler and from other Z-Wave vendors. FCC and IC COMPLIANCE STATEMENT Warning: Changes or modifications to this device not expressly approved by HomeRun Holdings Corp. could void the userʼs authority to operate the equipment. FCC REGULATORY STATEMENTS NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. INDUSTRY CANADA REGULATORY STATEMENTS Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users the antenna type and its gain should be chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than necessary for successful communication. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1) This device may not cause harmful interference and, 2) this device must accept any interference received, including interference that may cause undesired operation.

GLOSSARY Dimmer Kichler Lightingʼs Z-Wave dimmer module, 12387BK/WH Primary dimmer The first dimmer used to set up your Z-Wave network and associations. Note: Only the primary dimmer can be used to include or delete additional dimmers from a network. Secondary Any dimmer that is set up after the primary dimmer. Secondary dimmers cannot include or delete other dimmers to the network. Fixture Any light unit that is connected to a dimmer. Exclude Remove a dimmer from a network. Include Add a dimmer to a network. Network A collection of devices controlled by primary and secondary controllers or dimmers operating on the same system. Each network has its own unique identification code so that no one else can control the system. CONNECTOR RESET CONNECTOR MOUNTING SCREWS (+) DIM UP/ TURN-ON (-) DIM DOWN/ TURN-OFF

DIMMER INSTALLATION INSTRUCTIONS Before Installing: Read all instructions thoroughly before starting installation. All installations should comply with National and local electrical codes. If you have any doubts concerning installation, contact a qualified, licensed electrician. If possible, it is recommended to do any programming of the dimmer modules prior to installation. NOTE: The Z-Wave dimmer can be directly mounted to a Kichler LED fixture OR installed in-line using a Kichler LED interconnect cable. The dimmer can be connected between any two fixtures or at either end of a connected run of fixtures. For use only with Kichler LED 24VDC Class 2, 5 AMP MAX Lighting fixtures and accessories. INSTALLING Z-WAVE DIMMER DIRECTLY TO FIXTURES 1) Align connector on end of dimmer with connector on end of fixture. 2) Push dimmer to fixture until the fixture and the dimmer are flush and connectors snap together. 3) Drive pre-installed screws into mounting surface until fixture is secure. If screws are difficult to install, remove screws, mark holes, and drill 1/16 pilot holes. NOTE: DO NOT OVER TIGHTEN SCREWS. RESET

INSTALLING Z-WAVE DIMMER IN-LINE USING INTERCONNECT CABLES 1) Determine best location for dimmer. 2) Drive pre-installed screws into mounting surface until fixture is secure. If screws are difficult to install, remove screws, mark holes, and drill 1/16 pilot holes. DO NOT OVER TIGHTEN SCREWS. 3) Select proper length interconnect cable, P/N 12341 (9 ), 12342 (14 ), 12343 (21 ) or 12345 (10ʼ). 4) Hold interconnect cable to mounting surface and determine best path for cable. If interconnect cable is being run from cabinet to cabinet a notch such as a V could be cut in cabinet side panels to help keep cable out of sight. NOTE: Interconnect cable is UL rated Class 2. Installer should check with local building codes to determine if Class 2 wire is allowed to run through floors, walls and ceilings. 5) Peel backing off retaining clip(s) and affix to desired location(s). Surface should be as clean as possible. 6) Drive pre-installed screw into the cabinet surface to secure the retaining clip to the surface. 7) Slip Cable into clip(s) and snap closed. RESET Z-WAVE DIMMER SETUP Kichlerʼs 12387 Z-Wave full range dimmer can be used in a variety of ways to meet individual needs and installations. The dimmers can be used independently, connected to other 12387 dimmers, connected to a 12388 Z-Wave wall dimmer, or added to an already existing Z-Wave network. Determine how the system will be used from the set-up options below, and follow the instructions in that section. Set Up Options Option 1 - One dimmer on one fixture, or one set of fixtures. This option will be used for dimming a single fixture or group of fixtures that are connected to each other. Using this option will not allow the use of wireless dimming. Option 2 - Controlling one set of fixtures with two dimmers. This option will allow multiple dimmers to work together on one group of fixtures. Option 3 - Controlling two separately powered fixtures or sets of fixtures. This option will allow two groups of fixtures that are powered separately to work in unison using either dimmer. Option 4 - Multiple, separately powered fixtures or sets of fixtures controlled by any of the dimmers. This will allow multiple sets of separately powered fixtures to work in unison using any of the dimmers. Option 5 Adding a 12387 dimmer to an existing Z-Wave network from a 3 rd party vendor. This option will be used if you are setting up, or have an existing Z-Wave network from a 3 rd party vendor. Option 6 Dimming with 12388 Z-Wave wall dimmer. Kichlerʼs 12388 Z-Wave wall dimmer can be used together with any of the above options for wireless control of the light fixtures.

Option 1 - One dimmer on one fixture or one set of fixtures Connect the dimmer at a convenient place in the set of fixtures. No programming is required. Press and release the (+) button on the dimmer to turn on. Press and release the (-) button to turn off. Press and hold the (+) button, the lights will dim up. Pressing and holding the (-) button will slowly dim the lights down. Momentarily press and release the (-) to turn the lights off at the established dim level. Momentarily press and release the (+) to turn the lights on. The lights will return to the last established light level. Option 2 - Controlling one set of fixtures with two dimmers Dedicate one of the dimmers in this installation to be the primary dimmer, the other to be the secondary dimmer. Three steps will need to be performed. First, a network needs to be created. Second, the secondary dimmer will need to be associated to the primary. Third, the secondary dimmer needs an in-line synchronization added. NOTE: Power must be on Error is indicated by 10 dim blinks in succession. Success is indicated by 2 bright blinks in succession. Step 1 Create a network NOTE: There is a time limit of approx. 20 seconds to complete Step 1. If light fixture(s) blink 10 times while performing Step 1, this means that the time has expired and it will be necessary to repeat the process from the beginning. 1. Using as small object such as a paper clip, press & release recessed RESET button. (The primary dimmer light fixture will blink 2 2. Press & hold (+) button until the primary dimmer light fixture blinks 2 times. (Hold for hold approx. 2 seconds) On the secondary dimmer: 1. Press & release recessed RESET button. (The secondary dimmer light fixture will blink 2 2. Press & hold both (+) button and (-) button until both the primary dimmer light fixture and secondary dimmer light fixture blink 2 times. (Hold for approx. 2 seconds) Step 2 Associate (link) dimmers together NOTE: Step 2 has no time limit. 1. Press & hold both (+) and (-) buttons until the primary dimmer LED light fixture blinks 2 times (hold approx. 2 seconds) 2. Press & release (+) button to put the primary dimmer into ASSOCIATION ADD MODE. (lights will blink 2 On the secondary dimmer: 3. Press and release the (+) button. Both the primary dimmer fixture and secondary dimmer fixture will blink 2 times.

Option 3 - Controlling two separately powered fixtures or runs of fixtures Dedicate one of the dimmers in this installation to be the primary dimmer, the other to be the secondary dimmer. Two steps will need to be performed. First, a network needs to be created. Second, the secondary controller needs to be associated to the primary. NOTE: In order for 2 or more dimmers to work in unison, connect each dimmer to separate groups of light fixtures powered by different power supplies. Power must be on Error is indicated by 10 dim blinks in succession. Success is indicated by 2 bright blinks in succession. Dimmers must be installed within 50ʼ of each other to be able to communicate. Step 1 Create a Network NOTE: There is a time limit of approx. 20 seconds to complete Step 1. If light fixture(s) blink 10 times while performing Step 1, this means that the time has expired and it will be necessary to repeat the process from the beginning. 1. Using a small object such as a paper clip, press & release recessed RESET button. (The primary dimmer light fixture will blink 2 2. Press & hold (+) button until primary dimmer light fixture blinks 2 times. (Hold for hold approx. 2 seconds) On the secondary dimmer: 1. Press & release recessed RESET button. (The secondary dimmer light fixture will blink 2 2. Press & hold both (+) button and (-) button until both the primary dimmer light fixture and secondary dimmer light fixture blink 2 times. (Hold for approx. 2 seconds) Step 2 Associate (link) dimmers together NOTE: Step 2 has no time limit. 1. Press & hold both (+) and (-) buttons until the primary dimmer light fixture blinks 2 times (hold approx. 2 seconds) 2. Press & release (+) button to put the primary dimmer into ASSOCIATION ADD MODE. (lights will blink 2 On the secondary dimmer: 1. Press and release (+) button. Both the primary and secondary dimmer light fixtures will blink 2 times. Option 4 - Multiple, separately powered fixtures or sets of fixtures controlled by any of the dimmers One of the dimmers in this installation will be the primary dimmer, the others will be the secondary dimmers. Two steps will need to be performed. First, a network needs to be created. Second, the additional dimmers will need to be associated. NOTE: In order for 2 or more dimmer modules to work in unison, connect each module to separate light fixtures powered by different power supplies. Power must be on Error is indicated by 10 dim blinks in succession. Success is indicated by 2 bright blinks in succession. Step 1 Create a Network NOTE: There is a time limit of approx. 20 seconds to complete programming between primary and secondary dimmers and then the primary and additional secondary controllers. If light fixture(s) blink 10 times while performing Step 1, this means that the time has expired and it will be necessary to repeat the process from the beginning. 1. Using a small object such as a paper clip, press & release recessed RESET button. (The primary dimmer light fixture will blink 2 2. Press & hold (+) button until the primary dimmer light fixture blinks 2 times. (Hold for hold approx. 2 seconds)

On the secondary dimmer: 1. Press & release recessed RESET button. (The secondary dimmer light fixture will blink 2 2. Press & hold both (+) button and (-) button until both the primary dimmer light fixture and secondary dimmer light fixture blink 2 times. (Hold for approx. 2 seconds) For the additional dimmer(s): 1. Press & release recessed RESET button on the primary dimmer. (The primary dimmer light fixture will blink 2 2. Press & hold (+) button until the primary dimmer light fixture blinks 2 times. (Hold for hold approx. 2 seconds) 3. Press & release recessed RESET button on third dimmer. (The third dimmer light fixture will blink 2 4. Press & hold both (+) button and (-) button until both the primary dimmer light fixture and third dimmer light fixture blink 2 times. (Hold for approx. 2 seconds) Repeat steps 1 4 above to include all additional dimmers into the network. Step 2 Associate (link) the dimmers In this step, each dimmer will be first linked to the primary dimmer and then to each other. 1. Press & hold both (+) and (-) buttons until the primary dimmer light fixture blinks 2 times (hold approx. 2 seconds) 2. Press & release (+) button to put dimmer into ASSOCIATION ADD MODE. (Lights will blink 2 3. On the next dimmer, press and release (+) button. Both primary and next dimmer light fixtures will blink two times. These two dimmers are now associated. Repeat these steps for associating each additional dimmer to the primary dimmer. Now that each dimmer has been associated to the primary dimmer there are two options: Option 1 Leave set up as is. In this set up only the primary dimmer can be used to control all other dimmers. Option 2 Associate all dimmers so that any dimmer will control all others. Continue to Step 3. Step 3 Associate (link) the additional dimmers On the secondary dimmer: 1. Press & hold both (+) and (-) buttons until the secondary dimmer light fixture blinks 2 times (Hold approx. 2 seconds) 2. Press & release (+) button to put secondary dimmer into ASSOCIATION ADD MODE. (Lights will blink 2 3. On the third dimmer, press and release (+) button. Both secondary and third dimmer will blink 2 times. Step 3 will need to be repeated for all additional dimmers by associating each dimmer to all dimmers before it. Example: If 5 dimmers are being used, dimmer #2 will need to be associated to dimmers 3, 4, & 5. Dimmer #3 will need to be associated to dimmer 4 & 5, and dimmer #4 will need to be associated to dimmer 5. Option 5 Include a 12387 dimmer into an existing Z-Wave network from a 3 rd party vendor Step 1 Place 3 rd party controller into include or add mode. (Refer to your controllerʼs owner manual) Step 2 Include dimmer into the network 1. Using a small object such as a paper clip, press & release recessed RESET button. (The light fixture will blink 2 2. Press & hold both (+) and (-) buttons until the light fixture blinks 2 times (Hold approx. 2 seconds)

Option 6 Dimming with 12388 Z-Wave Wall Dimmer Before you start, install the 12388 wall dimmer in its intended location per the instructions included with the wall dimmer. Once installed, refer back to these instructions for programming. NOTE: If you are using more than one 12387 dimmer, refer to Options 1-4 for programming the dimmers together firstly. NOTE: Power to the light fixtures and wall dimmer must be on Error is indicated by 10 dim blinks in succession. Success is indicated by 2 bright blinks in succession. Step 1 Create a network NOTE: There is a time limit of approx. 20 seconds to complete Step 1. If light fixture(s) blink 10 times while performing Step 1, this means that the time has expired and it will be necessary to repeat the process from the beginning. On the primary dimmer (12387 dimmer): 1. Press & release recessed RESET button. (The primary dimmer light fixture will blink 2 2. Press & hold (+) button until the primary dimmer light fixture blinks 2 times. (Hold for hold approx. 2 seconds) On the wall dimmer: 1. Rapidly press and release either the top or bottom switch two times. (The primary dimmer light fixture will blink 2 Step 2 Include the wall dimmer into the network NOTE: Step 2 has no time limit. 1. Press & hold both (+) and (-) buttons until the primary dimmer LED light fixture blinks 2 times (hold approx. 2 seconds) 2. Quickly press & release (+) button to put the primary dimmer into ASSOCIATION ADD MODE. (Lights will blink 2 On the wall dimmer: 3. Rapidly press and release either the top or bottom switch two times. (The primary dimmer light fixture will blink 2 NOTE: If using more than one 12387 dimmer, it will be necessary to repeat Step 2 for each additional dimmer to connect it with the wall dimmer. Operating the 12388 Wall Dimmer NOTE: The lights will always return to the last intensity level set by the primary dimmer when the lights are turned on using the 12388 wall dimmer. Adjust the lights to the most frequently desired intensity level using the primary dimmer. Now when the lights are turned on using the 12388 wall dimmer, they will return to the set intensity. -To turn lights on, quickly press and release the upper switch paddle. -To turn lights off, quickly press and release the lower switch paddle. -To increase light intensity, press and hold the upper switch paddle. -To decrease light intensity, press and hold the lower switch paddle. -To return lights to their set intensity level (level set at primary dimmer), quickly press and release the upper switch paddle while lights are on. DIMMER MODULE OPERATION TURN LIGHTS ON: Momentarily press and release the (+) button on the dimmer module. TURN LIGHTS OFF: Momentarily press and release the (-) button on the dimmer module. INCREASE LIGHT LEVEL: Press and Hold the (+) button, release once desired light level is reached. DECREASE LIGHT LEVEL: Press and Hold the (-) button, release once desired light level is reached.

TROUBLESHOOTING Lights not working: Double check that all fixture, cable, and power connections are intact. Double check that power is on. Continue getting 10 blinks while trying to program dimmers: Make sure to firmly press all buttons while going through the programming steps. Confirm that only one dimmer is being used as the primary dimmer. Reset dimmer(s) see reset instructions under Additional Wireless Dimmer Programming Options. ADDITIONAL WIRELESS DIMMER PROGRAMMING OPTIONS Associations: Once in the network, the dimmer can be associated with other devices in the Z-wave network. The Kichler Z-Wave dimmer supports one (1) association group with a maximum of 5 devices. Basic Set and Multilevel Set commands are sent to the associated devices in group 1 when the user operates the (+) and (-) buttons on the Kichler Z-Wave dimmer. Manufacturer ID: 0x0114 Product ID: 0x0101 Device Class: Generic Type Switch Multilevel, Specific Type Not Used Comman Classes Supported (in addition to COMMAND_CLASS_BASIC) COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_SWITCH_MULTILEVEL Remove an association to a dimmer: 1. Press and hold the (+) and (-) buttons until primary dimmer light fixture blinks 2 times. (Hold for approx. 2 seconds) 2. Press & release (-) button. On the secondary dimmer (dimmer that is being un-associated): 1. Press & release (-) button. (Light fixture will blink 2 Exclude a dimmer from the network: 1. Press & release recessed RESET button. (Primary dimmer light fixture will blink 2 2. Press & hold (-) until the primary light fixture blinks 2 times. (Hold approx. 2 seconds) On the secondary dimmer (dimmer that is being excluded): 1. Press & release recessed RESET button. (Secondary dimmer light fixture will blink 2 2. Press & hold both (+) and (-) until both the primary and secondary dimmer light fixtures blink 2 times (Hold approx. 2 seconds) Remove In-line Synchronization: 1. Press & hold the recessed RESET button on dimmer until attached lights blink 2 times. (Hold approx. 2 seconds) 2. Press the '+' button. (Lights will quickly turn off) Reset Z-Wave Dimmer: 1. Press and hold the (+), (-) and recessed RESET buttons simultaneously until attached light fixture blinks 4 times. Note: When resetting a dimmer, it may also be necessary to unplug or remove power from the dimmer in order to reset the timing in the dimmer. Resetting the controller will clear the network and associations from the controller, as well as set the configuration parameters back to the default factory settings.