TOTALFLOW Technical Bulletin 139

Similar documents
Modbus RTU RS485 Manual

Standard VistaNET GCC Software: 803V029-(VER)(REV)

FieldServer Driver - Serial FS Notifier NCA

Process Gas Chromatograph

02/11/2015

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Process Gas Chromatograph

Metasys Integrator Cleaver-Brooks Application

ModBus DE-1 INSTALLATION AND USER MANUAL

Process Gas Chromatograph

02/11/2015

Temperature Controllers

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

RS485 MODBUS Module 8AI

FST DFS Notifier Onyx 640

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

PTE0705 Electric Fence Monitor

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

931D Style B Process Gas Chromatograph

Simplex Panel Interface Guide

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

P2267 NETWORK INTERFACE

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Table of Contents SECTION PAGE

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

MicroTech Self-Contained Air Conditioning System

MicroTech Series-200 Flooded Screw Chiller

Minimum Core Module Version: 4.0, build 1608 See full list of supported models below. Document Revision Date: 1/9/2018

Carbon Monoxide Transmitter

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

ProStar 325 UV-Vis Detector

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

MicroTech Series 200 Centrifugal Chiller

Universal Transmitter. Operations & Maintenance Manual

ICC. Macurco Modbus Monitor Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

FieldServer FS Secutron

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

NovaStar 4X Pager Alarm Software 5073NS4X-AD DCN-M409

MicroTech Unit Ventilator

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

GPS Evaluation Kit EVA1037/1080

MicroTech Rooftop/RMC

CALIDUS tm the Modular micro Gas Chromatograph

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Omnistat Architectual Specifications

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Net/X Thermostat Network Installation and Troubleshooting Guide

SystemsQT for Waters Alliance HPLC Systems (Revision G)

Mark 25 Ultrapure Water Conductivity Analyzer

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Technical Manual. Level Alarm Unit CARLA & WIDS

FIXED GAS ANALYZER (FGA)

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Metasys Integrator Vilter Application

Chemtron Science Laboratories Pvt. Ltd.

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

EQ-ROBO Programming : Cliff Check Robot

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

CTT8 TEMPERATURE MONITOR DEVICE

System 57. An advanced World of intelligent gas detection system management

IntesisBox BACnet/IP Server - Notifier ID3000 series

EWP2WIRELESS MOTION DETECTOR

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

USER MANUAL FOR OPERATING SYSTEM

Installation Manual Tracker 221

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

MO n : 12JMC rév A

System Galaxy Quick Guide

Agilent 1100 Series Refractive Index Detector. Reference Manual

Model A1700 Series Annunciator

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

FIS SMART SENSOR U (Draft 1) June 25, 2001

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Rev Flame Detection Sensor. TF100 User Manual

Avigilon Control Center System Integration Guide

User Guide OI/FEX100HART EN Rev. A. WaterMaster FEX100 HART Field Device Specification

and Channel indicator and monitoring unit B Operating Instructions 2.00/

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Operating instructions for moisture analyzers - UX 3001 (UX 3011, UX 3031, UX 3081) series

SEAR II APPLICATION 9V899-A01D PREPARED FOR NICTD

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Process Gas Chromatograph

Metasys Integrator Airflow Application

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Toxic Gas Detection. Model F12. Toxic Gas Detection

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Transcription:

TOTALFLOW Technical Bulletin 139 Manual Gating of CO2 on the BTU 8000 For Analyzing Very Low Concentrations of CO2 Totalflow Technical Bulletin Version 1.0, Revision AA (13 June 2006) ABB Inc. ABB Inc. 7051 Industrial Blvd Bartlesville, Oklahoma 74006 USA Telephone Domestic 800 442-3097 International (918) 338-4880 Telefax (918) 338-4607 Internet www.abb.com/totalflow

Purpose This document describes a procedure for improving the performance of the BTU 8000/8100 gas chromatograph when dealing with gas samples with very low concentrations of CO2. Description At times it may become necessary to modify the basic mode of operation of the BTU 8000/8100 to better report very low concentrations of CO2. For this modification to work well your GC must have very little noise on the baseline. If the GC has a noise problem due to power or grounding problems or has bad or marginal detector beads, those problems must be corrected first. You may want to have available the Modbus/Printer Console document for the BTU 8000 (2100666) and a copy of Hyperterm or other terminal program. A Terminal program is built into the BTU MMI software. For best results use this method on a Non-Manifold Non-EFR BTU 8000/8100. This version is somewhat more sensitive to very low concentrations of components than the Manifold EFR version. The Printer/Console command xxgt is used to manually set the gate on and off times for CO2. This allow us to make the gates trigger on and off without relying on the auto gate method that is normally used for all peaks except C6+. As a result, we should be able to measure lower concentrations of CO2. (Actual lower limit of detection will be determined by the amount of noise on the baseline and the accuracy of determining the gate on and off times.) 10/13/2006 2 Technical Bulletin 139

From the Printer Console Manual(2100666) xxgt - Gate Timing This command sets the gate timing. This value is the number of detector samples into the cycle to operate the gate (20 samples/second). The following is the position of the various gate events for 59/60 modules: Event Description Seconds Detector Samples 00 Detector 2 Balance 3.5 70 01 Auto-gate Detector 2 On (C2-, C3, IC4, NC4, NEOC5, IC5, NC5) 6 120 02 Detector 1 Balance 10 200 03 Local Baseline Measurement Detector 1 12 240 04 Auto-gate Detector 1 On (N2, C1, CO2) 13.5 270 05 Auto-gate Detector 1 Off 56.85 1137 06 CO2 Timed gate On 56.85 1137 07 CO2 Timed Gate Off 56.9 1138 08 Auto-gate Detector 2 Off 56.9 1138 09 Pre-purge On 61 1220 10 Detector 1 Balance 64 1280 11 Detector 2 Balance 65 1300 12 Gate Detector 1 On C4+, 2nd C3, C2 67 1340 13 Gate Detector 2 On C6+ 71 1420 14 Gate Detector 2 Off C6+ 132 2640 15 Local Baseline Measurement Detector 2 133 2660 16 Gate Detector 1 Off C2 150 3000 17 Local Baseline Measurement Detector 1 150.5 3010 18 Pre-purge Off 153.5 3070 NOTE: The CO2 timed gates are provided to allow ultra-low CO2 measurement on the order of 100 PPM. Normally, these should be left at the default. If this type of measurement is required, then the 10/13/2006 3 Technical Bulletin 139

gates will have to be set by hand. Also, any calibration should be done using a certified blend near the levels of CO2 and C1 that are expected. A chromatogram will show where the gating should be set in your individual case. Use the timeline on the chromatogram to determine where to place the gate on and gate off times and multiply the time by 20 to get the new entered value. (Don t use decimal numbers) Example; CO2 gate on should begin at 43 seconds and gate off at 52 seconds. 42 X 20 = 840 (05GT=840) Turn off Auto Gating 43 X 20 = 860 (06GT=860) Turn on CO2 Gate 52 X 20 = 1040 (07GT=1040) Turn off CO2 Gate 05GT must always be before the gate on time (06GT) These settings will allow us to gate a CO2 concentration up to approximately 1.0%. ***IF the CO2 will never see concentration levels of more than.5%, you may want to move the gate off back to 50 seconds (07GT=1000). Set the RS232 port of the BTU Transmitter to Printer Console protocol, 9600 baud, 8 data bits, None for parity, 1 stop bit, and use the Printer Console button on the MMI. 10/13/2006 4 Technical Bulletin 139

You may need to warm start the BTU to reset the communication port so you can talk to it. Conclusion If done correctly this should improve the sensitivity of the BTU 8000/8100 to CO2. However, if done improperly, it could effect the measurement of other components. Remember, when working in Printer Console mode, there are no checks and balances. The BTU 8000 will allow any entry even a wrong one. If in doubt about this method please contact Totalflow Customer Service at 1-800-442-3097 or 1-918-338-4880. 10/13/2006 5 Technical Bulletin 139