ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

COMPLETE WATER TEMPERATURE CONTROL SYSTEM

WATER TEMPERATURE CONTROL SYSTEMS

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

INSTALLATION ADJUSTMENT SERVICE

NEW GENERATION HIGH LOW SYSTEMS

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

MEGATRON MODEL TA, TA-LF

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

CLASSIC HIGH LOW MANIFOLD SYSTEMS

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

TA-300, TA-300-LF, TA-350, TA-350-LF

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

Wall Mounted Shower Systems

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

EZ Plate Instantaneous

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Mixing Safety and Performance

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

TMV45 & TMV80 Standard Thermostatic Mixing Valves

HL45, HL80 Thermostatic High-Low Valves

water source / fan coils

Automatic Temperature Controller (ATC)

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

DigiTemp. Digital Water Tempering System. PVI.com

WALL MOUNTED SHOWER SYSTEMS

SEQUENCE OF OPERATIONS

INDIRECT FIRED EQUIPMENT INSTALLATION FORM

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

HOT INLET COLD INLET INSTALLATION

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Med Touch Combination Alarm Conversion Kits

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

RQE Series Temperature Controllers

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Tri-Tech Medical Inc.

Installation S

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

SECTION HUMIDITY CONTROL EQUIPMENT

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

GOLD Plus 30/40/60/80

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

W1/B, O, W2/E, Y1, Y2, G. Gas or electric. Wireless, 915MHz, proprietary protocol. Up to 100 feet 24VAC, 2.4VA. Molded plastic

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

Semi-Instantaneous Indirect Fired Water Heater

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

Installation S

University of Delaware

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - EQUIPMENT

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

Heat Transfer Packages

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

Tri-Tech Medical Inc.

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

SECTION DOMESTIC WATER PIPING SPECIALTIES

Integrated Automation

Med Touch Master Alarm

AIS750 Series Alarm Annunciator

Project Name: Location: Engineer: Contractor: I. GENERAL

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Transcription:

1-1 3 1 5 1 kg/cm 11 1 1 1 1 1 1-1 3 1 5 1 1-1 3 1 5 1 1-1 3 5 1 COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Valve is ASSE 117 Certified Submittal S-11-1-LF August, 1 MEGATON LEAD FEE MODEL XLLF 1 HOT & COLD INLETS 1 ¼ MIXED OUTLET ¾ ETUN PIPING 1to1GPM(3.to31l/min) 1 Valve assembly is certified to meet Low-Lead requirements of wetted surface area containing less than.5% lead by weight. All other fittings and components, the sum total of which comprise the wetted surface of this product contains less than one quarter of one percent of lead by weight. See page for Specification detail 1 1 1 See page 3 for Drawing detail 1 See page for Flow capacity chart See page 5 for Options Engineer's Approval Job #! WANING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer. For more information, go to www.p5warnings.ca.gov 1 Leonard Valve Company Printed in USA Arch/Eng. Contractor Note: The models shown represent Leonard Products which are believed to be equivalent in type and function to items specified. Leonard Valve Company is not responsible for errors or omissions due to differences in interpretations of information provided. Product is non-cancellable and non-returnable from date from order with factory. Signed submittal required with purchase order. 13 Elmwood Avenue, Cranston, I 91 USA Phone: 1.1.1 Fax: 1.91.531 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com

EQUIED INFOMATION WHEN ODEING Circulator requirements must be specified by the Engineer, lines 1 and are EQUIED, line 3 is optional 1. Circulated flow required, (not mixing valve flow) SEE NOTE *. Head required without Megatron Assembly 3. Standard pump is TACO 13, if another manufacturer is preferred please specify, but note that ANY change from standard pump will result in a PICE INCEASE * NOTE: If circulated flow rate is greater than 1 GPM please select appropriate eturn Line Size from page 5 Piping Options, piping changes will also result in a price increase. MEGATON MODEL XL--LF * Lead Free construction, to comply with LEAD FEE requirements * Wetted surface area of this product contains less than one quarter of one percent (.5%) of lead by weight MEGATON MODEL XL--LF Complete Water Temperature Control Station (1-1 GPM, 3. to 31 l/min) to include: 1 bottom inlet connections (copper tube) 1 ¼ top outlet connection (copper tube) ¾ return line size with piping method #W Copper encapsulated thermostatic assembly with Teflon coated shuttle Locking temperature regulating handle set for 1 o F(9 o C) Temperature adjustment range, 9-1ºF (3-ºC) ** Full port ball valve, pressure gauge on mixed water outlet piping of mixing valve. Dial thermometer (range: to 1 F,-1to C) and pressure gauge on mixed water outlet of the system. Outlet Test Connection with ball valve and ¾ hose connection with cap Full port ball valve mounted downstream of test connection on mixed water outlet of the system Inlet piping manifold with full port ball valves and dial thermometers ( to F, -7 to 11 C on hot supply, to 1 F,-1to C on cold supply) on hot and cold supply inlets eturn piping, ¾, with aquastat, circulator, dial thermometer ( to 1 F,-1to C), balancing valve (with positive shutoff) to balance system, and check valve Aquastat with temperature differential of 5 to 3 F(3to17 C) GFCI* switch. The GFCI switch will be used to turn the circulator on or off for setup. *Ground Fault Interrupter Bypass piping, ¾, with check valve and isolation ball valve to cold inlet of mixing valve Maximum operating pressure: 15 PSIG (KPA) System mounted on strut, galvanized. Strut shall be assembled with three hole flat angle plate on corners, four hole tee plates or two hole flat plate connectors on all other support pieces using 3/ grip lock nuts and 3/ x 1 hex head cap screws, washers and lock washers. Factory pre-assembled and tested as a complete system All electrical connections to be completed by Electrical Contractor **NOTE: For temperatures outside of this valve s stated range, please see our line of bi-metal valves.

1-1 3 1 kg/cm 11 5 1 1 1 1 1 1 1 1-1 3 5 1 1 1 1-1 3 5 1 1 1 1-1 3 5 1 1 1 MEGATON MODEL XL--LF 3 " MIXED OUTLET 1 9 7 1 3/" ETUN FOM BUILDING 1 " 13 3 11 1 5 11 1 3/" ETUN TO HOT WATE SOUCE 3/" HOT SUPPLY 1" 3/" COLD SUPPLY 35" 1 Dimensions may vary with the addition of options see page #5 LEGEND 1. Full port ball valve. Mixing valve 3. Tee Drain. Test connection 5. Balancing Valve. Dial thermometer 7. Pressure gauge. Circulator-As specified by Engineer 9. Aquastat 1. Circulator power switch 11. Flapper check 1. Galvanized Strut 13. Tee bracket 1. Corner Bracket 3

MEGATON MODEL XL--LF (1 TO 1 GPM) Flow Capacity PESSUE DOP 5 1 15 5 3 35 5 5 PSI.3.7 1 1. 1.7.1.. 3.1 3. BA 1 19 3 39 3 51 55 5 1 GPM 3. 7 1 19 1 13 1 193 19 31 l/min MIN + FLOW NOTE: Flowrates will vary depending on existing field conditions. Leonard Valve Company always recommends using CASPAK sizing software for proper valve sizing and model number applications. Note: The XL--LF model must be selected based upon the following: Maximum system demand for mixed water System pressure drop* Designer s estimated minimum mixed water flow requirement *System pressure drop= the pressure available at the inlet of the mixing valve unit minus the pressure required to operate the farthest fixture, i, e,. Shower valves, in the building. EXTENDED THEMOSTAT WAANTY Call the factory at 1---1 for details on Leonard's exclusive Extended Limited Warranty for High Low System Thermostats. Note! Specifications are subject to change without notice.!!!!

1-1 3 1 5 1 1 1 kg/ cm 11 1 1 1 1 3 1-1 5 1 1 1 1-1 3 5 1 1 1 1-1 3 5 1 1 1 1 kg/cm 11 1 1 1 1 LEON AD 1 kg/cm 11 1 1 1 1 1 kg/cm 11 1 1 1 1 1 kg/cm 11 1 1 1 1 LEON A D OPTIONS LC Megatron furnished without a circulator. FM Megatron with 3 legs, 3 ½ feet and 5 degree braces front and back for mounting to floor in center of room. FS Megatron with legs to floor(shipped separate) to support the unit without hangers. CAB Megatron with SS cabinet around mixing valve PUMPS edundant recirculation pump PUMPS H High temperature loop recirculation pump HBP High temperature by-pass flush with locking ball valve OPTIONS * OPTIONS (shown on next page) * AL Audio Visual Alarm LC Less circulator DU emote Display Unit FM Floor mount LMS-1-P Leonard FS Free standing Monitoring system CAB Cabinet around mixing valve LMS-1-P-BMS Leonard PUMP-edundant recirculator Monitoring system pump with module to PUMPH-High temperature loop connect to building recirculator pump management HBP- High temperature by-pass flush PIPING OPTIONS * P 1-1 eturn line size (W) P 1-1/ 1-1/ eturn line size (W) P 1-1/ 1-1/ eturn line size (W) * Any option chosen will alter pricing 1 Leonard Valve Company Printed in USA 5 13 Elmwood Avenue, Cranston, I 91 USA Phone: 1.1.1 Fax: 1.91.531 Email: info@leonardvalve.com WEB: http://www.leonardvalve.com

OPTION AL: Leonard Single Probe Digital Temperature Alarm Primary Alarm Box includes: Single Point Temperature Probe - ange: -1ºF to 1ºF esolution: 1ºF User adjustable high & low set points and initial alarm delay period Audible & visual alarms emote alarm contacts (SPDT) with adjustable relay delay period Min./Max. temperature values AL option replaces analog outlet dial thermometer with a single digital display OPTION DU: Leonard emote Display Unit emote Alarm Delay Option Includes: Activation by Primary Alarm s (pictured above) remote alarm contacts Alarm Delay Module with yellow, red, green LED indicators ecommended maximum distance from controller to DU is 5 OPTION LMS-1-P: Leonard Point Digital Monitoring System with Alarm Unit includes: Four () Temperature Probes - ange: -1ºF to 1ºF esolution: 1ºF Audio & visual alarms User adjustable high & low temperature alarm set points Alarm delay period to prevent nuisance alarms emote alarm contacts (SPDT) with adjustable relay period 1/1 Ethernet Connection Web Server Interface for Setup & Commissioning Unit can send an E-mail transmission of alarms for up to contacts Unit can send an E-mail report daily with temperatures readings over the previous day LMS-1-P option replaces analog dial thermometers with a single digital display for all temperatures, incoming hot, incoming cold, outlet and return OPTION LMS-1-P-BMS: Leonard Point Digital Monitoring System with Alarm & Enhanced Protocol Communication Interface Module Primary Alarm Box includes: Four () Temperature Probes - ange: -1ºF to 1ºF esolution: 1ºF User adjustable high & low set points and initial alarm delay period Audio & visual alarms emote alarm contacts (SPDT) with adjustable relay period ProtoNode Accessory Box includes: Interface Module to connect LMS-1-P-BMS to Building Management System (-BMS) Network, Complete Protocol Package Supported protocols include BACnet MS/TP, BACnet IP, Modbus TU, Modbus TCP/IP, SNMP, JC N, available simply by selecting the proper DIP switches Cat 5 Ethernet Cable not included LMS-1-P-BMS option replaces analog dial thermometers with a single digital display for all temperatures, incoming hot, incoming cold, outlet and return 1 Leonard Valve Company Printed in USA 13 Elmwood Avenue, Cranston, I 91 USA Phone: 1.1.1 Fax: 1.91.531 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com