All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

Similar documents
DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

DirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Bring In the Fresh Air

PelletVent Multi-fuel venting system. UL 641.

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Technical and Dimensional Data. Saf-T Vent SC Plus

BDM Direct Vent systems are for use with direct vent gas fired appliances.

ULC S636 System. PolyPro. PolyPro Flex. Terminations

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

DURAVENT POLYPRO VENTING PRODUCTS

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

DuraTech. Installation Instructions. Combustion Air System

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Pellet Stove. Flex Pipe. Appliance Connector

CHIMNEYS AND VENTS CHAPTER 8

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.

CHAPTER 8 CHIMNEYS AND VENTS

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex

flexible venting simply perfect cost efficient convenient durable Est FREEDOM VENTING FLEX

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

CHAPTER 8 CHIMNEYS AND VENTS

Type B Gas Vent. Installation Instructions

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

VENT SYSTEM COMPONENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

FasNSeal 80/90 FasNSeal & FasNSeal W2 FasNSeal Flex

Installation Instructions

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

VP Pellet Pipe. For pellet burning stoves. FEATURES

FasNSeal. Installation Instructions

Installation & Maintenance Instructions

Ventis Direct Vent. Installation Instructions

INSTALLATION INSTRUCTIONS

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

Mitchell Metal Products, Inc.

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

Installation Instructions for PTS Chimney Liners: Ventinox /DuraFlex Pro /DuraFlex SW

SUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

MODEL CF CEILING SUPPORTED CHIMNEY

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

NovaVent. Dimensional Data

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

P P Gas Fireplace. P See Thru

PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

INSTALLATION INSTRUCTIONS

VERTICAL POWER VENT KIT

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Ultimate Pellet Pipe

Installation and Maintenance Instructions

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Twin wall Air Gap Insulated Zalutite & Aluminium Commercial Gas Vent Chimney System

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

INSTALLATION INSTRUCTIONS

St. Croix Greenfield Installation Manual

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Saf-T Vent SC Plus/SC 316

ZC Kit AGP Pellet Insert

Twin Wall Installation Instructions And Maintenance Guide

The intelligent alternative for flue gas venting systems

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Inspection Checklist Mechanical Final

Advanced Venting Systems

That s The Metal-Fab Way Experience The Difference

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4

ORTAL Power Vent System Manual Table of Contents

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

Direct Exhaust Venting Kit Instructions

SEPARATED COMBUSTION WARNING

AL29-4C (UNS S44735) Direct Vent System for Category II, III & IV Heating Equipment 3 through 16

Inspection Checklist Mechanical Rough in

INSTALLATION AND OPERATING INSTRUCTIONS

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

Transcription:

DuraTech ll-fuel, double-wall chimney system. UL 103 HT, UL 103, and UL S60.

DuraTech ll-fuel himney Typical Installations For 5-2 DuraTech *updated typicals* 6 1 19 8 16 1 19 5 1 8 1 6 2 Installation Key 1 DVL or Duralack 11 Tee with Tee ap 2 eiling Support 12 Tee Support 3 Wall Thimble 13 hase Top Flashing himney Pipe 1 ase Tee/Double Tee 5 ttic Insulation Shield 15 nchor Plate or nchor Plate with Damper 6 Flashing 16 Roof Support Storm ollar 1 Finishing ollar 8 himney ap 18 DVL dapter, Duralack Slip onnector, or Snap-Lock dapter 9 Elbow 19 DVL dapter (w/ or w/o damper) 10 Elbow Strap 3 athedral eiling 1 8 13 11 1 12 6 5 18 1 Oil Furnace 8 10 9 2 Refer to our Typical Installation drawings to select the appropriate component parts for your installation. DVL/Duralack himney dapter must be used when connecting DVL pipe to a eiling Support ox or Finishing ollar. When connecting Duralack pipe, a DVL/Duralack himney dapter, Duralack Slip onnector, or Snap-Lock dapter must be used. Wall Thimble must be installed with an appropriate length of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls, the telescoping pieces of the Wall Thimble can be separated, and a field-fabricated extension may be installed. ttic Insulation Shield must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not. Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a support box. himney ap Extended Roof racket Storm ollar Flashing 19 19 Through-The-Wall ttic Offset ttic Insulation Shield Firestop Radiation Shield 8 20 6 8 djustable Wall Strap himney Pipe 21 18 1 2 eiling Support ox DVL/Duralack himney dapter DVL or Duralack Pipe ppliance dapter Fireplace (New or retrofit) athedral eiling w/support ox 15 DuraVent www.duravent.com

DuraTech ll-fuel himney Typical Installations For 5-2 DuraTech *updated typical installations* Installation Key 1 DVL or Duralack 11 Tee with Tee ap 2 eiling Support 12 Tee Support 3 Wall Thimble 13 hase Top Flashing 8 8 himney Pipe 1 ase Tee/Double Tee 6 5 1 6 5 ttic Insulation Shield 15 nchor Plate or nchor Plate with Damper 6 Flashing 16 Roof Support Storm ollar 1 Finishing ollar 1 16 2 8 himney ap 18 DVL dapter, Duralack Slip onnector, or Snap-Lock dapter 19 1 19 1 9 Elbow 19 Stove dapter 10 Elbow Strap 3 athedral eiling 8 13 6 5 18 Oil Furnace 8 10 9 Refer to our Typical Installation drawings to select the appropriate component parts for your installation. DVL/Duralack himney dapter must be used when connecting DVL pipe to a eiling Support ox or Finishing ollar. When connecting Duralack pipe, a DVL/Duralack himney dapter, Duralack Slip onnector, or Snap-Lock dapter must be used. Wall Thimble must be installed with an appropriate length of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls, the telescoping pieces of the Wall Thimble can be separated, and a field-fabricated extension may be installed. ttic Insulation Shield must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not. Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a support box. 1 11 1 12 1 2 19 himney ap Extended Roof racket Storm ollar Flashing 19 Through-The-Wall ttic Offset 8 ttic Insulation Shield Firestop Radiation Shield 8 6 djustable Wall Strap 13 18 2 himney Pipe 15 1 eiling Support ox DVL/Duralack himney dapter DVL or Duralack Pipe ppliance dapter Fireplace (New or retrofit) athedral eiling w/support ox 15 DuraVent www.duravent.com

DuraTech 5-8 ll-fuel himney djustable Pipe *updated order #s* Use to add length to DuraTech chimney. djusts from 1-21. SIZE 6 8 1-21 ORDER # 6DT-21TSS 8DT-21TSS STOK # 810000092 81000023 Elbow Kit Elbow Kit includes: 2 Elbows and 1 Elbow Strap. 30 or 15 ½ Use for offsets around obstructions such as rafters, ridgepoles, or joists. May have two pairs of elbows, if needed. Offsets greater than 30 are not permitted in accordance to UL 103 standards. Elbows swivel 360 at base (angles are not adjustable). pair of elbows is required to return an offset chimney back to vertical. ½ vailable in stainless steel (SS) or galvalume (G) outer wall. G SS G SS 15 5 6 8 ORDER # -- 6DT-E15K DT-E15K 8DT-E15K STOK # -- 810000093 810000166 810000235 ORDER # 5DT-E15KSS 6DT-E15KSS DT-E15KSS 8DT-E15KSS STOK # 810000015 81000009 81000016 810000236 30 5 6 8 ORDER # -- 6DT-E30K DT-E30K 8DT-E30K STOK # -- 810000095 810000168 81000023 ORDER # 5DT-E30KSS 6DT-E30KSS DT-E30KSS 8DT-E30KSS STOK # 810000016 810000096 810000169 810000238 Elbow Strap 2 Use to prevent excessive weight on the elbows by supporting the weight of the chimney. Required to be installed between two elbows in offset installations. Multiple elbow straps may be required for offset installations. Refer to installation instructions. SIZE 5 6 8 2 16 8 9 10 ORDER # 5DT-ES 6DT-ES DT-ES 8DT-ES STOK # 81000001 81000009 81000010 810000239 19 DuraVent www.duravent.com

DuraTech 5-8 ll-fuel himney ombustion ir Square eiling Support ox *updated illustration* Use with ombustion ir System components. Delivers outdoor air as combustion air to the appliance. Operates as a direct vent system without requiring a second penetration to the building envelope. lack. Patent-pending. For pricing refer to the S price list. SIZE 6 6 8 8 2 36 2 36 ORDER # 6S-S2DT 6S-S36DT 8S-S2DT 8S-S36DT STOK # 81000086 810000869 810000881 810000883 181 11 Round eiling Support ox 6 Supports chimney pipe and provides a positive connection between support box and chimney with a built-in twist-lock. Supports up to 60' of DuraTech himney. Use adapter to attach DVL or Duralack to the support box. Painted black. Trim collars are sold separately. (For adapters see DVL/Duralack section). SIZE 5 6 8 5 1 6 1 1 8 1 9 9 11 11 11 12 13 1 ORDER # 5DT-RS 6DT-RS DT-RS 8DT-RS STOK # 810000021 810000102 8100001 81000023 Trim ollar For Round Support ox onceals the gap between the Round eiling Support ox and the ceiling cutout. Select square or round. Painted black. ½ ½ SQURE TRIM OLLR SIZE 5-6 - 8 9 1 8 11 1 8 1 16 ORDER # 5DT-T DT-T STOK # 810000022 81000015 ROUND TRIM OLLR SIZE 5-6 - 8 9 1 8 11 1 8 1 1 2 21 ORDER # 5DT-TR DT-TR STOK # 810000023 81000016 21 DuraVent www.duravent.com

ll-fuel himney DuraTech 5-8 Flat eiling Support ox 3 Supports chimney pipe and provides a positive connection between support box and chimney with a built-in twist-lock. Designed for installation in flat ceilings only. Supports up to 60' of DuraTech himney. Use adapter to attach DVL or Duralack to the support box. 2 wide trim collar is included. Not painted, but can be painted with high temperature paint. (For adapters see DVL/Duralack section). SIZE 5 6 8 5 1 6 1 1 8 1 9 9 11 11 11 12 13 1 1 ORDER # 5DT-FS 6DT-FS DT-FS 8DT-FS STOK # 81000002 810000103 8100001 8100002 Roof Support *updated description* 6 Designed to support the DuraTech himney and allows the chimney to pass through the roof and extend down from the ceiling. Ideal for cathedral ceilings and free-standing appliance installations. Supports up to a maximum total chimney length of 5' above and 20' chimney below Roof Support. djustable to different roof pitches. Use Finishing ollar and adapter to attach DVL or Duralack to the DuraTech chimney. Trim ollar not included. SIZE 5 6 8 8 9 10 ORDER # 5DT-RS 6DT-RS DT-RS 8DT-RS STOK # 810000025 81000010 81000018 81000025 Trim ollar For Roof Support onceals gap between chimney pipe and ceiling cut out when used with Roof Support. Galvalume. Painted black. ½ SIZE 5 6 8 18 18 20 20 1 8 1 9 1 10 1 0/12-3/12 ORDER # 5DT-RST3 6DT-RST3 DT-RST3 8DT-RST3 STOK # 810000026 810000105 81000019 81000026 /12-6/12 ORDER # 5DT-RST6 6DT-RST6 DT-RST6 8DT-RST6 STOK # 81000002 810000106 810000180 8100002 /12-9/12 ORDER # 5DT-RST9 6DT-RST9 DT-RST9 8DT-RST9 STOK # 810000028 81000010 810000181 81000028 10/12-12/12 ORDER # 5DT-RST12 6DT-RST12 DT-RST12 8DT-RST12 STOK # 810000029 810000108 810000182 81000029 800-835-29 DuraVent 22

DuraTech 5-8 ll-fuel himney Support ox Rails *new product offering* ttach to ouside of Square eiling Support ox to provide level, temporary support. This enables an installer to easily fasten the box in place without the need for another pair of hands. Simplifies installation. SIZE 6 ORDER # 6DT-SRU STOK # 81000036 18 1 Wall Thimble djustable D D djusts from a minimum of to a maximum of 10 wall thickness, and fits between standard wall studs. To accommodate thicker walls, the telescoping pieces can be extended up to 16 with a field-fabricated extension installed. Interior trim ring painted black. Must be installed with DuraTech chimney pipe horizontally through the wall and extend 6 into the room beyond the interior wall. (lack painted DuraTech is available). 6 and 8 stainless steel exterior trim available. SIZE 5 6 8 1 8 8 1 8 9 1 8 10 1 8 1 1 16 16 10 8 11 8 12 8 13 8 D 13 1 15 16 ORDER # 5DT-WT 6DT-WT DT-WT 8DT-WT STOK # 810000030 810000109 810000183 810000250 SS TRIM 5 6 8 ORDER # -- 6DT-WTSS -- 8DT-WTSS STOK # -- 810000110 -- 810000251 ombustion ir Wall Thimble Use with ombustion ir System components. Delivers outdoor air as combustion air to the appliance. Operates as a direct vent system without requiring a second penetration to the building envelope. lack. Patent-pending. Ø SIZE 6 8 6" 8 16 18 ORDER # 6S-WTDT 8S-WTDT STOK # 810000865 81000089 23 DuraVent www.duravent.com

DuraTech 5-8 ll-fuel himney Finishing ollar w/ dapter *updated description* New integrated collar with adapter, fits into the female end of the chimney pipe to provide a decorative black finish. Use on chimney pipe that is suspended with the roof support system or on pipe that is passing through a wall thimble. Provides proper connection to DVL or Duralack. No other adapter is needed. SIZE 5 6 8 ORDER # 5DT-F 6DT-F DT-F 8DT-F STOK # 81000003 810000115 810000188 810000256 nchor Plate Use to attach DuraTech himney to an appliance or masonry fireplace. heck with appliance manufacturer to ensure DuraTech himney is approved for use. 2 SIZE 5 6 8 5 6 8 8 9 10 9 10 11 12 ORDER # 5DT-P 6DT-P DT-P 8DT-P STOK # 810000038 810000116 810000189 81000025 Transition nchor Plate Use when converting from DuraLiner to DuraTech in chimney restoration. Use with a DuraLiner Slip onnector and Hanger (See DuraLiner section). SIZE 6 6 6 6 1 1 13 1 1 1 21 21 ORDER # 6DT-P1x1 6DT-P1x1 6DT-P13x21 6DT-P1x21 STOK # 81000011 810000118 810000119 810000120 SIZE 8 8 8 8 1 1 13 1 1 1 21 21 ORDER # 8DT-P1x1 8DT-P1x1 8DT-P13x21 8DT-P1x21 STOK # 810000258 810000259 810000260 810000261 25 DuraVent www.duravent.com

DuraTech 5-8 ll-fuel himney Finishing ollar w/ dapter New integrated collar with adapter, fits into the female end of the chimney pipe to provide a decorative black finish. Use on chimney pipe that is suspended with the roof support system or on pipe that is passing through a wall thimble. Provides connection to black DVL or Duralack. SIZE 5 6 8 ORDER # 5DT-F 6DT-F DT-F 8DT-F STOK # 81000003 810000115 810000188 810000256 nchor Plate *updated description* Use to attach DuraTech himney to an appliance or masonry fireplace. heck with appliance manufacturer to ensure DuraTech himney is approved for use. SIZE 5 6 8 2 5 6 8 8 9 10 9 10 11 12 ORDER # 5DT-P 6DT-P DT-P 8DT-P STOK # 810000038 810000116 810000189 81000025 Transition nchor Plate Use when converting from DuraLiner to DuraTech in chimney restoration. Use with a DuraLiner Slip onnector and Hanger (See DuraLiner section). SIZE 6 6 6 6 1 1 13 1 1 1 21 21 ORDER # 6DT-P1x1 6DT-P1x1 6DT-P13x21 6DT-P1x21 STOK # 81000011 810000118 810000119 810000120 SIZE 8 8 8 8 1 1 13 1 1 1 21 21 ORDER # 8DT-P1x1 8DT-P1x1 8DT-P13x21 8DT-P1x21 STOK # 810000258 810000259 810000260 810000261 25 DuraVent www.duravent.com

ll-fuel himney DuraTech 5-8 hase ir Intake w/ Rodent Guard llows required ventilation air into chase. Screen keeps rodents out. SIZE 6 ORDER # 6DT-I STOK # 810005052 Snow Splitter *updated product* 23 25 Three times thicker and stronger, allowing it to standup against heavier snow loads. endable attachment flanges allow it to mount on any roof slope. Use to divert snow around chimney, vent and roof flashing. onstructed of paintable galvanized material. Ships flat for easy assembly. Works with 6", ", 8", and 10". SIZE 6 ORDER # 6DT-SP STOK # 81000981 800-835-29 DuraVent 30

ll-fuel himney DuraTech 10-2 Round eiling Support ox 9 1 2 Supports chimney pipe and provides a positive connection between support box and chimney. Supports up to 0' of DuraTech himney. Trim collars are sold separately. (For 10 use Duralack Slip onnector to attach Duralack to the support box. See Duralack section). SIZE 10 12 1 16 10 5 16 12 5 16 1 5 16 16 5 16 1 16 18 20 16 18 20 22 ORDER # 10DT-RS 12DT-RS 1DT-RS 16DT-RS STOK # 810000298 810000336 810000368 81000000 Trim ollar For Round Support ox onceals gap between chimney pipe and ceiling cut-out when used with Round eiling Support ox. Galvalume. Painted black. *updated order numbers* ½ SIZE 10 12 1 16 1 1 16 1 18 1 20 1 20 22 2 26 ORDER # 10DT-TR 12DT-TR 1DT-TR 16DT-TR STOK # 810000299 81000033 810000369 81000001 Wall Thimble djustable D D Use to provide clearance to combustibles. djusts from a minimum of to a maximum of 10 wall thickness, and fits between standard wall studs. To accommodate thicker walls, the telescoping pieces can be extended up to 16 with a fieldfabricated extension installed. Interior trim ring painted black. Must be installed with DuraTech chimney pipe horizontally through the wall and extend 6 into the room beyond the interior wall. SIZE 10 12 1 16 12 1 8 1 1 8 16 1 8 18 1 8 20 22 2 26 15 8 1 8 19 8 21 1 8 D 18 20 22 2 ORDER # 10DT-WT 12DT-WT 1DT-WT 16DT-WT STOK # 810000300 810000338 81000030 81000002 800-835-29 DuraVent 3

DuraPlus ll-fuel, triple-wall chimney system. UL 103 HT.

ll-fuel himney DuraPlus Typical Installations *updated typicals* 8 8 6 9 6 10 5 15 15 2 2 1 1 Installation Key 1 DVL or Duralack Stovepipe 12 Tee Support racket 2 eiling Support ox 13 Wall Strap 3 Wall Thimble 1 Firestop Radiation Shield DuraPlus himney Snap-Lock dapter, DVL/Duralack himney 15 5 ttic Insulation Shield dapter, Duralack Slip onnector 6 Roof Flashing 16 Extended Roof racket Storm ollar 1 DVL or Duralack himney dapter 8 himney ap 18 DVL or Duralack Tee 9 Elbow 19 DVL or Duralack Elbow 10 Elbow Strap 20 hase Top Flashing 11 Tee with ap 21 nchor Plate 6 3 15 19 1 ttic Offset 8 13 11 12 18 19 athedral eiling Roof Support 8 6 5 2 1 1 Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. DVL/Duralack himney dapter or Duralack Slip onnector must be used when connecting DVL or Duralack stovepipe to eiling Support or Wall Thimble. Snap-Lock dapter must be used when attaching snap-lock stovepipe to DuraPlus. Wall Thimble must be installed with an appropriate section of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls a wall thimble extension can be field fabricated. n ttic Insulation Shield must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not. If chimney is enclosed in a chase in the attic space, an ttic Insulation Shield is not required. Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a eiling Support ox. himney ap Extended Roof racket Storm ollar Flashing Elbow Strap 6 Through-the-Wall 8 Oil Furnace 8 Elbow ttic Insulation Shield Firestop Radiation Shield himney Pipe Wall Strap 2 1 1 * 21 20 Second Floor hase eiling Support himney dapter Duralack Stovepipe or DVL Stovepipe Stove dapter Manufactured Home *DVL stovepipe required for this installation Fireplace (New or retrofit) 800-835-29 DuraVent 6

ll-fuel himney DuraPlus asic Kit *updated description* Kit includes: DVL and Duralack himney dapter, Snap-Lock dapter w/ Trim, 11 Square eiling Support ox with Trim, djustable Flashing 0/12-6/12, himney ap, Storm ollar, and ttic Insulation Shield. Only available in 6 diameter. Pipe not included. an be used for flat or vaulted ceiling installations. Use for typical through-the-roof installations. SIZE 6 ORDER # 6DP-KS STOK # 810000512 Manufactured Home Kit Kit includes: DVL and Duralack dapter, 2 Square eiling Support ox with Trim, djustable Flashing 0/12-6/12, himney ap, Storm ollar, and (2) 2 DuraPlus himney Pipe (galvanized). Only available in 6 diameter. an be used for cathedral ceiling installations. Use for manufactured home through-the-roof installations. SIZE 6 ORDER # 6DP-KMFG STOK # 810000513 Through-The-Wall Kit Kit includes: DVL and Duralack himney dapter, Snap-Lock dapter w/ Trim, 9 DuraPlus himney Pipe (galvanized), Wall Thimble, Tee w/ ap, (2) Wall Strap, Tee Support racket, and himney ap. Only available in 6 diameter. Use for through-the-wall installations. SIZE 6 ORDER # 6DP-KTTW STOK # 81000051 800-835-29 DuraVent 8

ll-fuel himney DuraPlus v asic Kit *updated photo and description* Kit includes: DVL and Duralack himney dapter, Snap-Lock dapter w/ Trim, 11 Square eiling Support ox with Trim, djustable Flashing 0/12-6/12, himney ap, Storm ollar, and ttic Insulation Shield. Only available in 6 diameter. Pipe not included. an be used for cathedral ceiling installations. Use for typical through-the-roof installations. SIZE 6 ORDER # 6DP-KS STOK # 810000512 Manufactured Home Kit Kit includes: DVL and Duralack dapter, 2 Square eiling Support ox with Trim, djustable Flashing 0/12-6/12, himney ap, Storm ollar, and (2) 2 DuraPlus himney Pipe (galvanized). Only available in 6 diameter. an be used for cathedral ceiling installations. Use for manufactured home through-the-roof installations. SIZE 6 ORDER # 6DP-KMFG STOK # 810000513 Through-The-Wall Kit *updated photo and description* Kit includes: DVL and Duralack himney dapter, Snap-Lock dapter w/ Trim, 9 DuraPlus himney Pipe (galvanized), Wall Thimble, Tee w/ ap, (2) Wall Strap, Tee Support racket, and himney ap. Only available in 6 diameter. Use for through-the-wall installations. SIZE 6 ORDER # 6DP-KTTW STOK # 81000051 800-835-29 DuraVent 8

DuraPlus ll-fuel himney Pipe Selection hart himney himney Installed Sections Used Installed Sections Used himney Height 6 12 2 36 himney Height 6 12 2 36 6 1 1-10 1 2 1 5 1' 1 15-1 2 1 5 2' 1 16-1 2 1 5 3' 1 1-1 2 6 3'- 1 2 1 1 1-9 1 6 3'-10 1 2 1 1 18'-3 1 6 '-10 1 2 1 1 19'-3 1 6 5'-10 1 2 2 20'-3 6'-3 1 2 20-1 2 1 6'-9 1 2 21-1 1 2 1 '-9 1 2 22-1 1 2 1 8'-9 3 23-1 1 2 8 9'-1 1 2 1 3 23'-6 1 8 9'- 1 2 1 3 2' 1 8 10'- 1 2 1 3 25 1 8 11'- 1 2 26 9 12 1 26-1 2 1 9 12'-6 1 26-10 1 2 1 9 13'-6 1 2-10 1 2 1 9 1'-6 5 28-10 1 2 10 himney Pipe *updated order numbers* Length Ø Ø Designed for appliances tested and listed for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas. 6, 9, and 12 chimney pipe has 1 insulation blanket; 2, 36 chimney pipe has 1 2 insulation. To calculate the installed length of DuraPlus chimney pipe, subtract 1 1 2 from each length of chimney pipe. dditional protective carton filler for shipping is available, items have stock numbers with (F). SIZE 6 8 ORDER # STOK # ORDER # STOK # ORDER # STOK # 6 8 10 11 12 6 6DP-06 810000515 DP-06 810000565 8DP-06 810000600 9 6DP-09 810000516 DP-09 810000566 8DP-09 810000601 12 6DP-12 81000051 DP-12 81000056 8DP-12 810000602 12 SS 6DP-12SS 810000518 -- -- -- -- 2 6DP-2 810000519 DP-2 810000568 8DP-2 810000603 2 -- -- -- -- 8DP-2F 81000060 2 SS 6DP-2SS 810000520 DP-2SS 810000569 8DP-2SS 810000605 2 SS -- -- -- -- 8DP-2SSF 810000606 36 6DP-36 810000521 DP-36 81000050 8DP-36 81000060 36 6DP-36F 810000522 -- -- 8DP-36F 810000608 36 SS 6DP-36SS 810000523 DP-36SS 81000051 8DP-36SS 810000609 36 SS 6DP-36SSF 81000052 -- -- 8DP-36 SSF 810000610 9 DuraVent www.duravent.com

ll-fuel himney DuraPlus Elbow Kit *updated order numbers* Kit includes: (2) elbows and one Elbow Strap. Use for offsets around obstructions such as rafters, ridgepoles, or joists. May have two pairs of elbows, if needed. Offsets greater than 30 are not permitted in accordance to UL 103 standards. Elbows swivel 360 at base (angles are not adjustable). pair of elbows is required to return an offset chimney back to vertical. vailable in stainless steel (KSS) or galvalume (K) outer wall. G SS G SS 15 6 8 1 1 3 3 1 8 1 ORDER # 6DP-E15K DP-E15K 8DP-E15K STOK # 810000525 81000052 810000611 ORDER # 6DP-E15KSS DP-E15KSS 8DP-E15KSS STOK # 810000526 81000053 810000612 30 6 8 1 2 5 8 5 3 3 3 ORDER # 6DP-E30K DP-E30K 8DP-E30K STOK # 81000052 8100005 810000613 ORDER # 6DP-E30KSS DP-E30KSS 8DP-E30KSS STOK # 810000528 81000055 81000061 Elbow Strap Ø Use to prevent excessive weight on the elbows by supporting the weight of the chimney. Required to be installed between two elbows in offset installations. Multiple elbow straps may be required for offset installations. Refer to installation instructions. 2 SIZE 6 8 10 11 12 ORDER # 6DP-ES DP-ES 8DP-ES STOK # 810000529 81000056 810000615 Round eiling Support 18 1 3 18 Supports chimney pipe and provides a positive connection between support box and chimney with a built-in twist-lock. Supports up to 35 of DuraPlus himney. Use adapter to attach DVL or Duralack to the support box. Painted black. Trim collar included. (For adapters see DVL and Duralack section.) SIZE 6 8 ORDER # 6DP-RS DP-RS 8DP-RS STOK # 810000530 8100005 810000616 800-835-29 DuraVent 50

DuraPlus HT ll-fuel, double-wall chimney system. UL S629.

Specifications pplications DuraPlus HT is a double-wall, all-fuel chimney system for anada for use with wood stoves; fireplaces; and appliances using wood, oil, gas, or coal. Materials and onstruction *updated* lanket insulation encased between inner and outer walls of.020 30 stainless steel. learances 2 clearance to combustibles. Diameters 6-8 Listings Listed to UL 103HT and UL S629 (13-P-03-2). UL 103 HT and UL S629 System DuraPlus HT *updated* DuraVent's blanket insulation in DuraPlus HT is made of lightweight ceramic refractory material. This insulation will not shrink or cause gaps like competitors products made of mineral wool and other loose-fill insulations. No gaps mean no hot spots to trigger fires to exterior combustibles. Encased between two stainless steel walls, the insulation maintains a barrier that will not shift or settle. The 2 wall keeps the exterior cool, while ensuring high temperatures for optimum draft performance on the inside. Twist-lock feature allows you to assemble DuraPlus HT quickly and precisely. No screws or rivets required and no locking bands needed either. The djustable Tee Support racket is reversible for installation above or below the tee, while ensuring a 2 clearance to combustibles (adjusts from 2 to 6 ). DuraPlus HT offers 15, 30, and 5 degree elbows and allows double offsets. himney pipe comes in lengths from 6 inches up to feet. Designed for normal, continuous operation at 1200 F (650 ) flue gas temperatures. DuraPlus HT is subjected to rigorous and stringent requirements of the UL S629 standard, including one hour at 100 F (925 ), plus three thirty minute chimney fire tests at 2100 F (1150 ). 61 DuraVent www.duravent.com

ll-fuel himney DuraPlus HT Typical Installations *updated key* 1 15 18 Multi-Story 8 9 11 12 1 15 13 1 18 athedral eiling Roof Support 8 1 9 1 10 Installation Key 1 DuraPlus HT himney Pipe 11 Reduced learance Firestop Radiation Shield 2 Elbow 12 Square eiling Support ox 3 Universal Elbow Strap 13 Universal Roof Support Tee w/ ap 1 Trim ollar for Roof Support (not shown) 5 Wall Thimble 15 Roof Flashing 6 djustable Tee Support racket 16 Roof Radiation Shield DVL/Duralack himney dapter 1 DVL or Duralack Stovepipe 8 himney ap 18 Stovetop dapter 9 Storm ollar 19 DVL or Duralack Elbow 10 Finishing ollar Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. DVL/Duralack himney dapter must be used when connecting DVL or Duralack stovepipe to a eiling Support, Wall Thimble or Finishing ollar. Wall Thimble must be installed with an appropriate section of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls use a Wall Thimble Extension. ll HT eiling Supports now feature an integrated ttic Insulation Shield. These must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not. If a chimney is fully enclosed within a chase, an attic insulation shield is not required. Note: For Multi-Story applications, an ttic Insulation Shield must be purchased separately. Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a ceiling support. The Roof Radiation Shield is only required when the chimney is enclosed in a chase within the attic space. It is not required when the chimney is unenclosed in the attic space. himney ap Extended Roof racket Storm ollar Flashing Roof Radiation Shield Elbow Strap Elbow 15 8 9 16 8 1 ttic Insulation Shield Firestop Radiation Shield 15 9 djustable Wall Strap 5 19 1 18 1 6 1 12 Second Floor hase eiling Support DVL/Duralack himney dapter Duralack Stovepipe or DVL lose learance onnector Stovepipe Stove dapter Through-The-Wall athedral eiling w/support ox 800-835-29 DuraVent 62

DuraPlus HT ll-fuel himney himney Pipe Ø Designed for appliances tested and listed for use in anada with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas. To calculate the installed section of DuraPlus HT chimney pipe, subtract 1 1 2 from each section of chimney pipe. DuraPlus HT pipe lengths are available with additional protective carton foam for shipping. vailable items have stock # s ending with (F). Length Ø SIZE 6 8 ORDER # STOK # ORDER # STOK # ORDER # STOK # 6 8 10 11 12 6 6HT-06 81000068 HT-06 8100000 8HT-06 81000039 12 6HT-12 81000069 HT-12 81000005 8HT-12 8100000 18 6HT-18 810000650 HT-18 81000006 8HT-18 8100001 2 6HT-2 810000651 HT-2 8100000 8HT-2 8100002 36 6HT-36 810000652 HT-36 81000008 8HT-36 8100003 36 6HT-36F 810000653 - - - - 8 6HT-8 81000065 HT-8 81000009 8HT-8 810000 8 6HT-8F 810000655 - - - - Elbow Kit *updated order numbers* Kit includes: Two Elbows and one Elbow Strap. Use for offsets around obstructions such as rafters, ridgepoles, or joists. May have two pairs of elbows, if needed. Elbows swivel 360 at base (angles are not adjustable). pair of elbows is required to return an offset chimney back to vertical. Made of stainless steel. (Note: 5 elbows are only allowed in anada. The maximum angle allowed in the U.S. is 30. Refer to installation instructions) 15 6 8 1 1 3 3 1 8 1 ORDER # 6HT-E15K HT-E15K 8HT-E15K STOK # 810000656 81000010 8100005 30 6 8 1 2 5 8 5 3 3 3 ORDER # 6HT-E30K HT-E30K 8HT-E30K STOK # 81000065 81000011 8100006 5 6 8 6 6 6 3 3 3 ORDER # 6HT-E5K HT-E5K 8HT-E5K STOK # 810000658 81000012 810000 65 DuraVent www.duravent.com

DuraPlus HT ll-fuel himney Reduced learance Square eiling Support ox Use with flat, vaulted, or cathedral ceilings. Square eiling Support ox is painted black. 12 x 12 framing dimension permits installation within narrow joist spaces. ox will carry to 0 of DuraPlus HT himney, and doubles as an ttic Insulation Shield. Starter Section built in. Reduces the usual 2 clearance (per side) down to a 1 clearance (per side) for the 6 diameter only. vailable in 2 or 36 box height. omes with trim, insulation collar, and DVL himney dapter. Refer to eiling Pitch table as listed with Square eiling Support ox to determine size of support box needed. vailable for use with 6 chimney only. SIZE 6 6 2 36 12 12 16 16 ORDER # 6HT-S2R 6HT-S36R STOK # 81000066 810000665 ombustion ir Square eiling Support ox *updated illustration* Use with ombustion ir System (S) components. Delivers outdoor combustion air to the appliance without the need for an additional penetration of the building envelope. Supports up to 0 of DuraPlus HT himney. Support box also doubles as an ttic Insulation Shield. omes with trim, and insulation collar. Stovepipe adapter is already built-in. vailable in 2 inch or 36 inch length. Use with flat, vaulted, or cathedral ceilings. Patent-pending. 181 11 SIZE 6 8 2 2 ORDER # 6S-S2HT 8S-S2HT STOK # 810000868 810000882 36 36 ORDER # 6S-S36HT 8S-S36HT STOK # 81000080 81000088 Universal Support ox Rails 18 ttach to ouside of Square eiling Support ox to provide level, temporary support. This enables an installer to easily fasten the box in place without the need for another pair of hands. Simplifies installation. One size fits 6,, 8 DuraPlus HT support boxes. SIZE 6-8 ORDER # 6HT-SRU STOK # 81000001 1 6 DuraVent www.duravent.com

ombustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. UL 1 and UL S61. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. UL S61. Duralack Single-wall interior stovepipe for connecting woodstoves to chimney.

Stovepipe ombustion ir System ombustion ir Wall Thimble Provides connection between DuraTech or DuraPlus HT chimney systems and the ombustion ir Stovepipe. djusts to fit wall thicknesses from 5 1/2 to 10. Extends into room 6. Painted black. Patent-pending. Ø DURTEH SIZE 6 8 6 6 16 18 ORDER # 6S-WTDT 8S-WTDT STOK # 810000865 81000089 DURPLUS HT SIZE 6 8 6 6 16 18 ORDER # 6S-WTHT 8S-WTHT STOK # 810000866 810000880 ombustion ir eiling Support w/ ollar *updated illustration* Provides connection between DuraTech or DuraPlus HT chimney systems and the ombustion ir Stovepipe. vailable in 2 or 36 heights, the eiling Support ox acts as an attic insulation shield with the addition of a Storm ollar. eiling Support extends a total of -1/2 below the ceiling. lack. DURTEH 181 11 SIZE 6 6 8 8 2 36 2 36 ORDER # 6S-S2DT 6S-S36DT 8S-S2DT 8S-S36DT STOK # 81000086 810000869 810000881 810000883 DURPLUS HT SIZE 6 6 8 8 2 36 2 36 ORDER # 6S-S2HT 6S-S36HT 8S-S2HT 8S-S36HT STOK # 810000868 81000080 810000882 81000088 800-835-29 DuraVent 90

PelletVent Pro iofuel venting system. UL 61, UL S609, and UL/ORD 1.

PelletVent Pro iofuel himney Typical Installations *updated key* 16 8 Pellet Insert 1 2 8 3 1 3 6 1 athedral eiling Stove Installation 2 3 5 13 2 Installation Key 1 Vertical ap 10 Horizontal ap 2 Storm ollar 11 Wall Thimble 3 Flashing 12 eiling Support Firestop Spacer athedral eiling Support ox 13 Tee w/ lean-out Tee ap 5 Straight Length Pipe 1 Wall Strap 6 5 Elbow 15 ttic Insulation Shield ppliance dapter 16 Prairie Termination ap 8 Flex Length 1 S djustable Wall hannel 9 90 Elbow 16 Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. The inner pipe diameter should match the outlet size of the appliance. For installations that require vent and the appliance has a 3 outlet, use an Increaser dapter 3 -. heck the appliance manufacturer's installation instructions to confirm which types of vent configurations are permitted (i.e. horizontal, vertical, chimney reline, etc.). lso, check for any venting restrictions such as maximum horizontal run, minimum and maximum vertical rise, maximum offset, etc. e fire safe! Maintain the minimum clearances (air-space) between the vent pipe and nearby combustibles, as specified in the appliance manufacturer's installation instructions. Use proper support and bracing. Follow local building codes and have your venting system inspected. 5 5 15 9 12 Round Horizontal ap 13 13 13 90 Elbow Wall Strap Straight Length Pipe Masonry himney Relining ttic Offset Tee with lean-out Tee ap 9 Wall Thimble 5 10 11 5 ppliance dapter 10 13 11 Through-The-Wall Vertical Rise Through-The-Wall 111 DuraVent www.duravent.com

PelletVent Pro iofuel himney Male Flex dapter Use to connect ioflex to PelletVent Pro when relining a masonry chimney. Only approved for use with ioflex. SIZE ORDER # STOK # 3 3PVP-DFM 810001063 PVP-DFM 810001126 ppliance dapter Use to attach to appliance outlet allowing for easy pipe connection. Seal adapter to appliance with high temperature sealant. 3⅜ 3¾ SIZE ORDER # STOK # SIZE STOK # 3 3PVP-D 81000105 PVP-D 810001123 3 LK 3PVP-D 810001058 LK PVP-D 81000112 Quick Release dapter Use to attach to appliance outlet allowing for easy pipe connection. Features an adjustable hose clamp and gasket to form a tight seal. The hose clamp can be loosened and tightened as needed to disconnect and connect the vent to the appliance. SIZE ORDER # STOK # - 6 3PVP-DS 81000699 3 1/8-8 PVP-DS 810006995 1/8 Harman dapter *new product offering* Use to provide a secure, tight fit to the exhaust outlet on any Harman Pellet Stove. Seal with high temperature silicone sealant to insure a tight connection. SIZE ORDER # STOK # 3 3PVP-DH 810001059 Harman dapter Increaser *new product offering* Use to increase vent diameters. Specifically designed for Harman Pellet Stoves. SIZE ORDER # STOK # 3 3PVP-XDH 810005891 11 DuraVent www.duravent.com

DuraLiner Insulated, double-wall masonry relining. UL 1 and UL S635.

DuraLiner himney Relining Spacer Use to maintain a 1 clearance with flex sections of DuraLiner. 3¼ SIZE ORDER # STOK # 6 OVL 6DLR-S 810001203 8 OVL 8DLR-S 81000122 djustable Sleeve Use for rear stove exits. Sleeve adjusts from 8 1 2 to 12. 8½ to 12 SIZE ORDER # STOK # 6 6DLR-S 81000120 8 8DLR-S 81000123 Masonry Thimble w/ Slip onnector ¼ - 10 1 Use to penetrate masonry chimney to allow connection of Duralack or DVL to DuraLiner. dapter must be used to attach the connector pipe to the masonry thimble. SIZE ORDER # STOK # 5 5DLR-MTS 810001191 6 6DLR-MTS 81000091 8 8DLR-MTS 81000095 Wall Pass Through *updated illustration* 1 5-10 8 1 Use to connect to a DuraLiner tee. Transitions DuraLiner through a masonry chimney and a combustible wall. llows the connection of Duralack pipe when used with the appropriate adapter. DVL black pipe will connect directly to the Wall Pass Through. SIZE ORDER # STOK # 6 6DLR-WPT 810001205 6 1 2 8 8DLR-WPT 8100012 8 1 2 10 133 DuraVent www.duravent.com

himney Relining DuraLiner Oval-To-Round Flex Pipe Use through damper and smoke shelf area. Use to connect from oval stove outlet to round DuraLiner. Use with DuraLiner ProMesh and ProFoil, where flex extends into clay liner, for zeroclearance applications. uilt from 1-ply construction,.005 30 stainless steel. ¾ SIZE ORDER # STOK # 6 6DLR-36ORF 810001216 3 6 5 8 36 6 6DLR-60ORF 81000121 3 6 5 8 60 8 8DLR-36ORF 810001251 10 3 8 5 8 36 8 8DLR-60ORF 810001252 10 3 8 5 8 60 Round-To-Oval Flex Pipe ¾ Use to connect a round stove outlet to oval DuraLiner. Use with DuraLiner ProMesh and ProFoil, where flex extends into clay liner, for zero-clearance applications. uilt from 30 stainless steel. SIZE ORDER # STOK # 6 6DLR-1ROF 810001218 6 5 8 3 1 ompilation Nominal Pipe Size Ø Ø Ø 8 8DLR-1ROF 810001253 8 5 8 10 3 3 3 3 5/8 3 1/2 5/8 1/2 5 5 5 5/8 5 1/2 6 6 6 5/8 6 1/2 5/8 1/2 8 8 8 5/8 8 1/2 Round Rigid Pipe - 5" *updated description* Ø Use to reline masonry chimney with 0/0 clearance. Factoryinsulated. Twist-lock fittings and pre-drilled hole (one screw required). UL Listed for zero clearance between masonry and combustibles, plus zero clearance between liner and masonry. 30 stainless steel inner and aluminized steel outer. Note: to calculate the installed length of 5, 6, and 8 DuraLiner pipe subtract 1 ½ from each joint overlap of liner pipe sections. SIZE ORDER # STOK # 5 5DLR-12 810001185 5 5 8 12 5" 5DLR-2 810001186 5 5 8 2 5 5DLR-36 81000118 5 5 8 36 5" 5DLR-8 810001188 5 5 8 8 800-835-29 DuraVent 136

DuraLiner himney Relining Round Rigid Pipe *updated description* Use to reline masonry chimney with 0/0 clearance. vailable in round 6 and 8 diameters in 12, 2, 36, and 8 lengths. Factory-insulated. uilt-in, pre-drilled fittings for riveting joints. 30 stainless steel inner and aluminized steel outer. Note: to calculate the installed length of 5, 6, and 8 DuraLiner pipe subtract 1 ½ from each joint overlap of liner pipe sections. SIZE ORDER # STOK # 6 6DLR-12 810001219 6 5 8 12 6 6DLR-2 810001220 6 5 8 2 6 6DLR-36 810001221 6 5 8 36 6 6DLR-8 810001222 6 5 8 8 8 8DLR-12 81000125 8 5 8 12 8 8DLR-2 810001255 8 5 8 2 8 8DLR-36 810001256 8 5 8 36 8 8DLR-8 81000125 8 5 8 8 Oval Rigid Pipe *updated description* ¾ Use to reline masonry chimney with 0/0 clearance. vailable in oval 6 and 8 diameters; 12, 2, 36, and 8 lengths. Factory-insulated. uilt-in, pre-drilled fittings for riveting joints. 30 stainless steel inner and aluminized steel outer. Note: to calculate the installed length of 5, 6, and 8 DuraLiner pipe subtract 1 ½ from each joint overlap of liner pipe sections. SIZE ORDER # STOK # 6 6DLR-12O 810001223 3 12 6 6DLR-2O 81000122 3 2 6 6DLR-36O 810001225 3 36 6 6DLR-8O 810001226 3 8 8 8DLR-12O 810001258 10 3 12 8 8DLR-2O 810001259 10 3 2 8 8DLR-36O 810001260 10 3 36 8 8DLR-8O 810001261 10 3 8 Twist-Lock ap Kit ap Storm ollar Support lamp ase Plate Use to terminates DuraLiner at the top of the masonry chimney. Pipe not included. Kit includes ase Plate, Support lamp, Storm ollar, and ap. SIZE ORDER # STOK # 5 5DLR-KV 810001189 13 13 5" 5DLR-KV 810001190 13 18 13 DuraVent www.duravent.com

DuraFlex Flexible stainless steel relining for masonry chimney. UL 1 and UL S635.

DuraFlex SW Stainless Steel Flexible Relining Factory-uilt Reline Kit *new product offering* Use as a relining system for factory-built chimneys to be used with solid-fuel appliances in the US. Relining is critical for performance and safety when a wood-burning insert is installed into an existing UL-12-listed fireplace. Kit includes: ap, Storm ollar, Support racket, Ventilation Disk, entering racket, DuraLiner 12" Length, Flex onnector, Flex Length (25' or 35'), djustable and, and Flex dapter. 6" SIZE 25' FLEX 35' FLEX ORDER # STOK # ORDER # STOK # DuraFlex Pro 6DFPRO-25KF 8100019 6DFPRO-35KF 81000150 DuraFlex 30 6DF30-25KF 81000151 6DF30-35KF 81000152 DuraFlex 316 6DF316-25KF 81000153 6DF316-35KF 8100015 DuraFlex SW asic Kit Kit includes: DuraFlex SS Top Plate, DuraFlex SS ap, DuraFlex SS onnector, and DuraFlex SW length. Flex lengths available in 15, 20, 25, 30, and 35. SIZE 15 FLEX 20 FLEX 25 FLEX ORDER # STOK # ORDER # STOK # ORDER # STOK # 3 3DFSW-15K 810002293 3DFSW-20K 81000229 3DFSW-25K 810002295 DFSW-15K 810002298 DFSW-20K 810002299 DFSW-25K 810002300 5 5DFSW-15K 810002303 5DFSW-20K 81000230 5DFSW-25K 810002305 5 1 2 55DFSW-15K 810002308 55DFSW-20K 810002309 55DFSW-25K 810002310 6 6DFSW-15K 810002313 6DFSW-20K 81000231 6DFSW-25K 810002315 DFSW-15K 810002318 DFSW-20K 810002319 DFSW-25K 810002320 8 8DFSW-15K 810002323 8DFSW-20K 81000232 8DFSW-25K 810002325 SIZE 30 FLEX 35 FLEX ORDER # STOK # ORDER # STOK # 3 3DFSW-30K 810002296 3DFSW-35K 81000229 DFSW-30K 810002301 DFSW-35K 810002302 5 5DFSW-30K 810002306 5DFSW-35K 81000230 5 1 2 55DFSW-30K 810002311 55DFSW-35K 810002312 6 6DFSW-30K 810002316 6DFSW-35K 81000231 DFSW-30K 810002321 DFSW-35K 810002322 8 8DFSW-30K 810002326 8DFSW-35K 81000232 165 DuraVent www.duravent.com

DuraFlex Pro Stainless Steel Flexible Relining DuraFlex Pro Top Plate/ap Kit *updated product offering* Kit includes: Top Plate with welded Storm ollar, and ap, plus DuraFlex SS onnector, and DuraFlex Pro length. Flex remains secured to the Storm ollar/top Plate when removing the cap section for inspections and cleaning. SIZE 20 FLEX 25 FLEX ORDER # STOK # ORDER # STOK # 3 3DFPRO-20VK 810002221 3DFPRO-25VK 81000696 DFPRO-20VK 810002222 DFPRO-25VK 810002223 5" -- -- 5DFPRO-25VK 810006969 5 1 2 55DFPRO-20VK 810002226 55DFPRO-25VK 81000222 6" -- -- 6DFPRO-25VK 810002230 " -- -- DFPRO-25VK 81000691 8" -- -- 8DFPRO-25VK 81000693 SIZE 30 FLEX 35 FLEX ORDER # STOK # ORDER # STOK # 3 -- -- 3DFPRO-35VK 810006968 DFPRO-30VK 81000222 DFPRO-35VK 810002225 5" -- -- 5DFPRO-35VK 81000690 5 1 2 55DFPRO-30VK 810002228 55DFPRO-35VK 810002229 6" 6DFPRO-30VK 810002231 6DFPRO-35VK 810002232 " -- -- DFPRO-35VK 81000692 8" -- -- 8DFPRO-35VK 8100069 DuraFlex Pro Ovalized Top Plate/ap Kit *updated photo and description* Kit includes: Welded Top Plate with lamp, Rain ap with lamp, Oval to Round Insert dapter with lamp, and DuraFlex Pro length with the first feet ovalized. Flex remains secured to the Storm ollar/top Plate when removing the cap section for inspections and cleaning. 25 FLEX 35 FLEX SIZE ORDER # STOK # ORDER # STOK # 6 6DFPRO-25OVLVK 810002233 6DFPRO-35OVLVK 81000223 169 DuraVent www.duravent.com

Ventinox Welded, flexible relining for masonry chimney. UL 1 and UL S635.

himney Relining Ventinox 12 Typical Installations *updated installation key* 1 2 3 8 1 6 2 3 Installation Key 1 Rain ap w/ Storm ollar 2 Top over Plate 3 Flex Length Tee with Removable Snout 5 Sleeve 6 Rigid Type Gas Vent or Rigid Pipe Length djustable Elbow 8 DuraFlex ppliance dapter 9 ottom Plate w/ ollar 10 ProFoil w/promesh or Thermix Gas Furnace Gas Stove Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. 2 2 1 1 3 10 3 10 9 ap with Storm ollar Top over Plate 1 5 Fireplace Insert Open Fireplace Ventinox Flexible Length Sleeve 800-835-29 DuraVent 1

DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.

DirectVent Pro Direct Vent Wall Thimble Provides a complete wall-pass-through and firestop. Use with Square Horizontal ap only. May be required in anada. Refer to the appliance manufacturer s installation instructions for requirements. SIZE ORDER # STOK # x 6 5 8 6DV-WT 810001316 6 3 11 12 5 x 8 58DV-WT 81000100 8 1 12 1 2 12 1 2 Wall Thimble - Small *updated dimensions* Provides a complete wall-pass-through and firestop. Use with Round Horizontal ap and Sconce ap only. May be required in anada. Refer to the appliance manufacturer s installation instructions for requirements. SIZE ORDER # STOK # x 6 5 8 6DV-WTS 81000131 6 3 11 11 5 x 8 58DV-WTS 81000101 8 1 9 9 Universal Wall Thimble Provides a complete wall-pass-through and interior firestop. Features an adjustable sleeve for an exact fit. Eliminates visible trim on exterior or wall near cap. Sized to fit all DuraVent DirectVent Pro s termination caps. SIZE ORDER # STOK # x 6 5 8 6DV-WTU 810001318 11 6 3 5 x 8 58DV-WTU 81000102 11 8 1 8 Wall Firestop For horizontal (through-wall) installations. Refer to the appliance manufacturer s installation instructions for requirements. SIZE ORDER # STOK # x 6 5 8 6DV-WFS 810001319 6 3 12 1 2 10 1 2 5 x 8 58DV-WFS 81000103 8 1 12 10 191 DuraVent www.duravent.com

Direct Vent DirectVent Pro Low-Profile Termination ap D Use for vertical terminations only. heck the appliance manufacturer s instructions to determine which caps are approved for use with their appliance. vailable in aluminum and stainless steel (S). SIZE ORDER # STOK # D x 6 5 8 6DV-V 810001360 8 1 6 5 8 3 1 12 1 2 x 6 5 8 6DV-V-S 810001361 8 1 6 5 8 3 1 12 1 2 5 x 8 58DV-V 81000133 8 5 8 8 5 8 1 1 2 5 x 8 58DV-V-S 8100013 8 5 8 8 5 8 1 1 2 Extended Vertical Termination ap *updated dimensions* D Use in extremely cold climates. Similar to the Low Profile Termination ap but taller in overall height to separate the air intake vents from the exhaust area. Refer to the appliance manufacturer s installation instructions for requirements. vailable in aluminum. SIZE ORDER # STOK # D x 6 5 8 6DV-VE 810001362 16 ¾ 6 5 8 11 ¾ 12 1 2 5 x 8 58DV-VE 81000135 16 ¾ 8 11 1/8 1 1 2 luminum Flex Length Use 3 flex with the co-linear system and flex with onversion Kits. See DuraFlex L section for more information. Flexible.010 thick 2-ply aluminum. Pricing for luminum Flex Length are listed under DuraFlex L. SIZE LENGTH ORDER # STOK # 3 35 3DF-35 810002988 35 DF-35 810002998 Flex oupling Use to join flex liner sections together. Pricing for luminum Flex Length are listed under DuraFlex L. 3 SIZE ORDER # STOK # 3 3DF-F 810002992 DF-F 810003000 800-835-29 DuraVent 198

DirectVent Pro Direct Vent o-xial To o-linear ppliance onnector Use o-linear dapter for stoves with X 6 5 8 co-axial outlets. Refer to appliance manufacturer s installation instructions for approval. Uses 3 aluminum flex for both intake and exhaust. D SIZE ONNETOR ORDER # STOK # D x 6 5 8 STNDRD 6DV-GL 810001363 10 1 2 3 1 2 1 8 x 6 5 8 TRVIS INDUSTRIES 6DV-TL 81000136 10 1 2 3 1 2 6 3 8 x 6 5 8 VERMONT STINGS 6DV-VL 810001365 10 1 2 3 1 2 8 5 8 himney Liner Termination Kit 18 18 Kit includes: Termination onnector and Flashing. DirectVent Pro x 6 5 8 Termination aps, 3 Flex, and o-linear Flex onnectors are sold separately. DirectVent Pro chimney liner termination kit must be tested and listed for each appliance. Refer to stove manufacturer s installation instructions. SIZE ORDER # STOK # 0 0 x 6 5 8 6DV-GK 810001269 3 3 x 6 5 8 6DV-T 810001368 3 ppliance dapter *updated description* 6 5 8 ttaches to appliance outlet allowing pipe to easily connect or disconnect. Vermont astings adapter #268. SIZE ORDER # STOK # x 6 5 8 6DV-DP 810001366 13 15 3 1 16 Monessen dapter llows the installer to attach DuraVent s DirectVent Pro x 6 5 8 pipe to a Monessen x direct vent exhaust outlet. Twist lock with a crimped male end. SIZE ORDER # STOK # x 6 5 8 6DV-DM 810005935 199 DuraVent www.duravent.com

Type Gas Vent Type Gas Vent Type gas venting system. UL 1 and UL S605. DuraFlex L luminum flexible relining UL 1 & UL S635.

c-ul-us 1 System Duraonnect II Double-wall connector pipe, UL approved as a Type Gas Vent segment, for use in conditioned and unconditioned attics and crawl spaces. (Not to be enclosed and cannot penetrate through walls, floors, or ceilings.) DuraVent s Duraonnect II is known as the ontractor s hoice for its ease of installation and durability. Duraonnect II s heavy-duty construction features precision twistlock connection, which provides ease of assembly or disassembly without damage to the product. The double-wall flexible vent is certified as having the equivalent thermal properties as Type Gas Vent and can be used when a Type Gas Vent double-wall connector is required. Specifications Duraonnect II Materials and onstruction.010 Double-wall aluminum flex inner wall (two-ply.005 ),.018 galvalume outer wall, with twist-lock connections. learances 1 to combustibles. Diameters 3" - 6". Listings c-ul-us Listed to UL 1 and UL/ ORD-1 (MH1089). UL 1 & UL S635 System DuraFlex L n economical venting system used for relining masonry chimney for natural gas or liquid propane category I, draft hood equipped appliances, and appliances tested and listed to use Type Gas Vent for a wide range of applications, including: natural gas fireplaces, gas-fired furnaces, boilers, water heaters, and wall or space heating applications. Protects the masonry chimney from damaging effects of flue product condensation. DuraFlex L *updated* pplications DuraFlex L (DFL) aluminum flexible relining for masonry chimney. Use with natural gas or liquid propane category I, draft hood equipped appliances, and appliances tested and listed to use Type Gas Vent. pplications include: natural gas fireplaces, gas-fired furnaces, boilers, water heaters, and wall or space heating applications. Materials and onstruction 010 aluminum (2-ply of.005 ). learances 0 clearance to masonry. Diameters 3,, 5, 5 ½, 6,, and 8. Listings Listed to UL 1 and UL S635. 800-835-29 DuraVent 20

Type Gas Vent DuraFlex L DuraFlex L - luminum Length Use with ategory I gas-burning appliances with draft hood. UL 1 aluminum liner. Flex lengths available in 25, 35, and 50. SIZE 25 FLEX 35 FLEX 50 FLEX ORDER # STOK # ORDER # STOK # ORDER # STOK # 3 3DF-25 81000298 3DF-35 810002988 3DF-50 810002989 DF-25 81000299 DF-35 810002998 DF-50 810002999 5 5DF-25 81000300 5DF-35 810003008 5DF-50 810003009 5 1 2 55DF-25 81000301 55DF-35 810003018 55DF-50 810003019 6 6DF-25 810003026 6DF-35 81000302 6DF-50 810003028 DF-25 810003036 DF-35 81000303 DF-50 810003038 8 8DF-25 81000306 8DF-35 8100030 8DF-50 81000308 oupler *new part* Use to connect DuraFlex L lengths to PolyPro. To be used in combustion air only. PPS-P may be used to secure connection. SIZE ORDER # STOK # 3 3DF-FP 8100052 DF-FP 8100035 Hanger racket *new part* Use to secure and hang DuraFlex L lengths from top of enclosure. To be used on combustion air only. Must be used with FT himney ap or FK Lining Kit. SIZE ORDER # STOK # 3 - DF-F 8100051 DuraFlex L oupling Use to connect DuraFlex L lengths to appliance, type gas vent, or flex lengths. 3 SIZE ORDER # STOK # SIZE ORDER # STOK # 3 3DF-F 810002992 6 6DF-F 810003029 DF-F 810003000 DF-F 810003039 5 5DF-F 810003010 8 8DF-F 81000309 5 ½ 55DF-F 810003020 229 DuraVent www.duravent.com

Stainless Steel Flexible Relining DuraFlex DuraFlex Insert dapter *new part* Use to connect the flex to an insert that has a flat surfaced outlet. SIZE ORDER # STOK # 3 3DFS-D 81000806 DFS-D 8100080 5 5DFS-D 81000808 5 1 2 55DFS-D 81000809 6 6DFS-D 810008050 DFS-D 810008051 8 8DFS-D 810008052 DuraFlex SS onnector Use to connect DuraFlex SS length to an appliance, rigid length, or flex length. Drip-free connection. 1/8 SIZE ORDER # STOK # 3 3DFS-F 8100022 1 8 3 3 1 2 DFS-F 81000232 1 8 1 2 5 5DFS-F 8100021 1 8 5 5 1 2 5 1 2 55DFS-F 81000251 1 8 6 5 1 2 6 6DFS-F 81000260 1 8 6 1 2 6 DFS-F 81000269 1 8 1 2 8 8DFS-F 810002 1 8 8 8 1 2 DuraFlex SS Reducer Ø5 ½ Use to connect 5 1 2 DuraFlex SS length to a 6 appliance. heck with the appliance manufacturer before reducing the vent size. May also be used to connect to stovepipe on a through masonry wall installations. 1/8 Ø6 SIZE ORDER # STOK # 5 1 2 6DFS-X55 81000265 DuraFlex SS Tee w/ ap Use to attach to DuraFlex SS length with a fast connect band. Removable branch connects tee body with an internal fast connect band. 5 1 2" Tee has a 6" branch. SIZE ORDER # STOK # 3 3DFS-T 81000223 8 ½ 3 1 DFS-T 81000231 9 ½ 1 5 5DFS-T 8100020 9 ½ 1 5 ½ 55DFS-T 81000250 10 ½ 3 8 6 6DFS-T 81000259 10 ½ 3 8 DFS-T 81000268 11 ½ 1 2 8 8DFS-T 8100026 13 5 3 8 800-835-29 DuraVent 16

FasNSeal & FasNSeal W2 Single-wall and double-wall special gas vent systems. UL 138 and UL S636. FasNSeal Flex Flexible chimney liner for special gas vent system. UL 138 and UL 1.

Specifications pplications FasNSeal and FasNSeal Flex is for use with natural gas or propane ategories II, III and IV appliances or anada s Type H Gas Vent Systems, having a maximum rated operating temperature of 80 F and a maximum positive pressure of 15 (FasNSeal Flex 6") water column. FasNSeal can be used on a wide range of applications, including: high efficiency gas boilers, furnaces, booster heaters, pool heaters, water heaters, unit heaters, or tankless water heaters. FasNSeal W2 is ideal for use on commercial applications such as: office buildings, medical facilities, condos, or multiple unit apartment complexes where there is the need for low clearances to combustibles. In residential applications, FasNSeal W2 is the perfect solution for running between floor joists or in walls. Materials and onstruction *updated materials* FasNSeal 3 : L29-.016 8 12 : L29-.019 1 2 : L29-.02 FasNSeal Flex Single strip double layer super-ferritic stainless steel (totalling.010 ). FasNSeal W2 3 6 : L29- stainless steel.016 inner wall, stainless steel.016 outer wall. : L29- stainless steel.016 inner wall, stainless steel.02 outer wall. 8 12 : L29- stainless steel.019 inner wall, stainless steel.02 outer wall. 1 2 : L29- stainless steel.02 inner wall, stainless steel.02 outer wall. UL 138 and UL S636 Systems FasNSeal & FasNSeal W2 ll FasNSeal (single-wall) and FasNSeal W2 (double-wall) vent lengths and components feature patented built-in mechanical locking band and triple-lipped directional gaskets. ll pipes and components are engineered with smooth clean welds located 90 from mechanical locking bands. This construction feature allows for ease of installation. The ½ air space between the inner and outer wall on FasNSeal W2 helps to reduce the clearance to combustibles in addition to creating a heat shield for additional safety. ll FasNSeal components which come in contact with exhaust gases and condensates are now silicone free. This important design and manufacturing feature greatly reduces the chances of system breakdown and failure. The main problems with silicone are there are too many adhesion factors which are very difficult to control and the process of binding similar materials with an epoxy, which can weaken the bond over time. Welded seams ensure a leak-free product that is meant to last. FasNSeal Flex Made from super-ferritic stainless steel. orrosion resistant. Manufactured with a sure-seal locking seam for superior strength and flexibility. The smooth inner-wall provides for no output reduction, allowing for full appliance efficiency, ease of cleaning and regular maintenance. The smooth inner wall optimizes gas flow, minimizes back pressure, and facilitates condensate management. Only flexible chimney liner listed to UL 138 standard. Diameters FasNSeal (single- and double-wall) 3-2 FasNSeal Flex 3-12 Listings FasNSeal (single- and double-wall) UL Listed to UL 138 and UL S636. FasNSeal Flex UL Listed to UL 138 and UL 1 and UL S636. 233 DuraVent www.duravent.com

D 3. USE NON-OMUSTILE HNGER EVERY SIX (6) FEET OF HORIZONTL RUN.. USE FIRE-RTED FIRESTOPS WHEN PENETRTING FIRE-RTED WLLS ND/OR EILINGS. 5. REFER TO THE FSNSEL INSTLLTION INSTRUTIONS FOR DDITIONL REQUIREMENTS. NOTE: Every effort has been made to ssure the accuracy of this information. Dura-Vent cannot guarantee ccuracy and will not be held liable for Errors or omissions. NOTES: 1. LL WORKMNSHIP MUST MEET ND/OR EXEED LL JURISDITIONL REQUIREMENTS. 2. INSTLL WLL RKET EVERY TWELVE (12) FEET OF VERTIL RUN. 1 3 2 3X 2X 6 10 2 2X 13.50 2X 2 6 5 5 16 5 3 28.00 5.00 8 11 12 26.00 6 8 2.50 16 16 16 9 33.11 2 16 10 6 16 3 56. 2 22.00 22.00 18.5 13 16 2 6 10 5 5 16 X 16 5 60.3 16 6 1 15 182.50 2 2 ITEM 1 2 3 5 6 8 9 10 11 12 13 1 15 16 1 REVISION HISTORY ZONE REV DESRIPTION DTE PPROVED DRWN W. YOUNG 9/2/2010 HEKED Q MFG PPROVED QTY 3 12 3 3 11 10 5 2 1 6 1 1 1 3 3 13 USTOMER # PRTS LIST PRT NUMER DESRIPTION 30051 FS-E8 100165 W2-9008 10016 FS-SWDW8 103956 W2-VL8-L 100080 W2-3608 100255 W2-VL8 100050 W2-1808 100020 W2-1208 103956 W2-VL8-L 100065 W2-208 103956 W2-VL8-L 100135 W2-508 100006 W2-0608 100198 FS-DWSW8 300191 FSS8 300366 FSL9 SIZE THIRD NGLE PROJETION DWG NO 1 SHEET 1 OF 1 USTOM 6 in. length 8 in. length 10 in. length NOTIE: THIS DOUMENT ONTINS PROPRIETRY INFORMTION ND IT SHLL NOT E USED, REPRODUED, OR ITS ONTENTS DISLOSED, IN WHOLE OR IN PRT, WITHOUT THE EXPRESS WRITTEN ONSENT OF PROTEH SYSTEMS DIVISION OF M & G DUR-VENT OMPNY, IN. REV D FasNSeal Special Gas Vent ommercial pplications ommercial projects may require custom parts and unique system designs. DuraVent offers complete project assistance: 2 10 16 6 1 15 oilers are: erco MK. 2.0 (3X) M & G Engineering Services: Personalized system design services offer comprehensive D submittal drawing and complete bills of materials. ustom Parts: If your project requires innovative solutions, contact DuraVent for custom parts that meet your specific project needs. FasNSeal W2: FasNSeal W2 is the ideal choice for commercial applications where there is a need for low clearances to combustibles. Up to 2 Vent Diameters: Many commercial applications require large diameter systems due to the units size and output. Large diameters are available in single and double wall, featuring FasNSeal s triple lipped directional gaskets and built-in locking band which provides a safe and convenient installation. learances hart *updated table* FasNSeal Rated Operating Temperatures Enclosed Unenclosed Horizontal Vertical Horizontal Vertical 3-5 - 2 19 F \ 90 0" 0" (anada Only) 300 F / 19 Sides: 8 /203.2mm 1 / 25.mm Top: 12 /30.8mm 80 F / 29 101.6mm ottom: /101.6mm 3 / 6.2mm 1 / 25.mm 19 F / 90 0" 0" (anada Only) 300 F \ 19 3 / 6.2mm 3 / 6.2mm Noncombustible Enclosure 80 F \ 29 3 / 6.2mm 3 / 6.2mm FasNSeal W2 Rated Operating Temperatures Enclosed Unenclosed Horizontal Vertical Horizontal Vertical 19 F (anada Only) 0" 0" 0" 0" 3-300 F 3 1 1 1 00 F 6" 1 3 1 80 F 6" 3 1 19 F (anada Only) 0" 0" 0" 0" 5-16 300 F 3 1 1 1 00 F 6" 1 3 1 80 F 6" 6 3 3 Rated Operating Temperature of 300 F = Max Flue Gas Temperature of 35 F Rated Operating Temperature of 80 F = Max Flue Gas Temperature of 550 F 235 DuraVent www.duravent.com

FasNSeal Special Gas Vent Female Flex dapter Use to connect FasNSeal Flex to FasNSeal rigid Vent Pipe at the top of the system. Ø Ø SIZE ORDER # STOK # 3 FSSMF-3 81000311 2 5 3 1 5 FSSMF- 810003199 3 5 1 5 5 FSSMF-5 81000328 5 5 1 5 6 FSSMF-6 810003300 5 5 6 1 5 FSSMF- 81000332 6 5 1 5 SIZE ORDER # STOK # 8" FSSMF-8 81000338 5 8 1 5 9" FSSMF-9 81000325 8 5 9 1 5 10" FSSMF-10 81000366 9 5 10 1 5 12 FSSMF-12 81000350 11 5 12 1 5 Test Port *updated order #s* Use to test for proper appliance operation without penetrating the vent wall. Easy access to perform flue gas analysis. More options available, see Universal dapter w/test Port in FasNSeal ppliance dapter section. 5⅞" SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FSTP03 810003135 9 FSTP09 81000322 FSTP0 810003196 10 FSTP10 81000363 5 FSTP05 81000325 12 FSTP12 81000350 6 FSTP06 81000329 1" FSTP1 81000351 " FSTP0 810003339 16" FSTP16 81000355 8 FSTP08 81000338 90 Elbow Use to go from horizontal to vertical runs or vertical to horizontal runs. Use to turn vent 90. SIZE ORDER # STOK # 3 FSEL9003 810003106 6 FSEL900 81000315 1 2 6 1 5 FSEL9005 81000321 5 6 3 6 FSEL9006 810003269 5 1 2 1 2 FSEL900 810003315 6 1 8 8 8 FSEL9008 81000335 6 1 2 8 1 9" FSEL9009 81000339 9 10" FSEL9010 81000335 1 2 9 3 8 SIZE ORDER # STOK # 12 FSEL9012 8100036 8 1 2 10 1 1 FSEL901 810003516 9 1 2 11 3 8 16 FSEL9016 810003551 11 12 1 2 18 FSEL9018 810003583 11 1 2 13 1 8 20 FSEL9020 810003603 12 1 2 1 1 2 22 FSEL9022 810003623 13 3 8 15 2 FSEL902 81000362 1 1 2 16 1 8 239 DuraVent www.duravent.com

FasNSeal Special Gas Vent Tall one Roof Jack Use as a heat shield within the flashing. Maintains center-line and clearance to combustibles. Use with Tall one Flashings. 18 SIZE ORDER # STOK # 3 FSRJ3 810005286 " " FSRJ 81000528 5" 5" FSRJ5 810005288 6" 6" FSRJ6 810005289 " " FSRJ 81000023 8" 8" FSRJ8 8100053 9" SIZE ORDER # STOK # 9" FSRJ9 810005290 10" 10" FSRJ10 810005291 11" 12" FSRJ12 810005292 13" 1" FSRJ1 810005293 15" 16" FSRJ16 81000529 1" Tall one Flashing *updated description* 12 Use to create a weather-tight penetration where the vent passes through a flat roof. Roof Jack and Storm ollar required. SIZE ORDER # STOK # 3 FSF3 81000525 1 3 " FSF 810005258 5 1 3 5" FSF5 810005259 6 1 3 6" FSF6 810005260 1 3 " FSF 810005261 8 1 3 8" FSF8 810005262 9 1 3 SIZE ORDER # STOK # 9" FSF9 810005263 10 1 3 10" FSF10 81000526 11 1 3 12" FSF12 810005269 13 1 3 1" FSF1 81000520 15 1 3 16" FSF16 81000521 1 1 3 Tapered Increaser Use to increase vent diameter. reates a smooth transition for an undisruptive flow. vailable in custom size combinations. SIZE ORDER # STOK # 3 x FS030TI 810003136 3 6 9 10 x 5 FS005TI 810003191 5 6 9 10 Eccentric Increaser Use to transition to a larger diameter pipe. Prevents condensate puddling when used on horizontal runs. ids in reducing formation of condensates. Maximum 10 difference between diameter increase size on both sizes. vailable in custom size combinations. SIZE ORDER # STOK # 3 x FS030EI 81000313 6 8 10 3 8 x 5 FS005EI 810003193 5 3 25 251 DuraVent www.duravent.com

Special Gas Vent FasNSeal Stepped Increaser Use to increase vent diameter when space constraints are an issue. vailable in custom size combinations. 6 SIZE ORDER # STOK # 3 x FS3I 810003138 3 x 5 FS5I 810003195 5 Tapered Reducer Use to reduce vent diameter. reates a smooth transition for an undisruptive flow. Maximum 10 diameter increase size on both sizes. vailable in custom size combinations. SIZE ORDER # STOK # x 3 FS003TR 810003192 3" 6 9 10 5 x FS050TR 81000322 5 " 6 9 10 Stepped Reducer Use to reduce vent diameter when space constraints are an issue. vailable in custom size combinations. 6 SIZE ORDER # STOK # x 3 FS3R 81000319 3 5 x FS5R 81000323 5 Double-Wall dapter *updated description* Use to transition from a single-wall pipe to double-wall pipe. To transition from double-wall to single-wall, please reference single-wall adapter available in single-wall FasNSeal section. Ø SIZE ORDER # STOK # 3 FS-SWDW3 810003139 3 SIZE ORDER # STOK # 12 FS-SWDW12 810003505 3 FS-SWDW 81000319 3 1" FS-SWDW1 81000352 3 5 FS-SWDW5 81000326 3 16" FS-SWDW16 81000356 3 6 FS-SWDW6 810003298 3 18 FS-SWDW18 810003593 3 " FS-SWDW 81000330 3 20 FS-SWDW20 810003613 3 8 FS-SWDW8 810003385 3 22 FS-SWDW22 810003633 3 9 FS-SWDW9 81000323 3 2 FS-SWDW2 810003652 3 10 FS-SWDW10 8100036 3 800-835-29 DuraVent 252

Special Gas Vent FasNSeal W2 Single-Wall dapter *updated description* Use to transition from double-wall pipe to single-wall pipe. To transition from single-wall to double-wall, please reference double-wall adapter available in single-wall FasNSeal section. SIZE ORDER # STOK # SIZE ORDER # STOK # 3 FS-DWSW3 81000366 9 FS-DWSW9 810003801 FS-DWSW 81000369 10 FS-DWSW10 810003821 5 FS-DWSW5 8100031 12 FS-DWSW12 81000386 6 FS-DWSW6 8100033 1" FS-DWSW1 81000381 " FS-DWSW 81000359 16" FS-DWSW16 810003893 8 FS-DWSW8 81000382 Firestop/Flat Flashing Use when penetrating floor levels. When installing double-wall with this component use 1 larger diameter, (e.g. 10 vent system, use 11 size). SIZE ORDER # STOK # SIZE ORDER # STOK # FSFS 810003181 1 15 5 FSFS5 81000323 5 2 5 1 6 FSFS6 81000328 6 2 5 1 " FSFS 810003331 2 5 19 8 FSFS8 8100033 8 2 5 19 9 FSFS9 81000313 9 2 5 22 10 FSFS10 81000351 10 2 5 22 11 FSFS11 810003823 11 2 5 2 12 FSFS12 81000392 12 2 5 2 13 FSFS13 81000388 13 2 5 26 1" FSFS1 810003532 1 2 5 26 15 FSFS15 81000382 15 2 5 28 16" FSFS16 81000356 16 2 5 28 1 FSFS1 81000389 1 2 5 30 18 FSFS18 810003591 18 2 5 30 19 FSFS19 810003912 19 2 5 32 20" FSFS20 810003611 20 2 5 32 21 FSFS21 810003929 21 2 5 3 22" FSFS22 810003631 22 2 5 3 23 FSFS23 81000396 23 2 5 36 2" FSFS2 810003650 2 2 5 36 Wall racket Use to support vent pipe or tee sections. Provides proper clearance to combustibles. When installing FasNSeal W2 with this component use 1 larger diameter, (e.g. 10 vent system, use 11 size). SIZE ORDER # STOK # " FSW 810003183 SIZE ORDER # STOK # 11 FSW11 810003826 11 1 2 5 FSW5 810003236 5 1 2 12 FSW12 8100039 12 8 6 FSW6 810003289 6 5 13 FSW13 810003850 13 8 1 2 " FSW 810003333 5 1 2 1" FSW1 81000353 1 9 8 FSW8 81000336 8 6 15 FSW15 8100038 15 9 1 2 9 FSW9 81000315 9 6 1 2 16" FSW16 810003569 16 10 10 FSW10 81000353 10 1 FSW1 810003896 1 10 1 2 800-835-29 DuraVent 26

Special Gas Vent FasNSeal W2 Storm ollar Use to create a weather tight seal between the pipe and flashing. When installing FasNSeal W2 with this component use 1 larger diameter, (e.g. 10 vent system, use 11 size). SIZE ORDER # STOK # FS 810003188 5 FS5 810003239 6 FS6 810003293 " FS 810003336 8 FS8 810003381 9 FS9 81000319 10 FS10 81000360 11 FS11 81000382 SIZE ORDER # STOK # 13" FS13 810003852 15" FS15 81000385 1" FS1 810003898 19" FS19 810003915 21" FS21 810003932 23" FS23 81000398 25" FS25 810003965 Variable Pitch Roof Flashing Use to create a weather-tight penetration where the vent pipe passes through the roof. Storm ollar required. When ordering Flashings for FasNSeal W2 product the flashing diameter and vent diameter are the same. ie. W2-3610 requires a FSVPF10. ccommodates flat to 9/12 roof pitch. SIZE ORDER # STOK # FSVPF 810003190 6 5 FSVPF5 81000321 6 FSVPF6 810003295 8 " FSVPF 810003338 9 8 FSVPF8 810003383 10 9 FSVPF9 81000321 11 10 FSVPF10 81000362 12 SIZE ORDER # STOK # 12 FSVPF12 810003503 1 1" FSVPF1 81000350 16 16" FSVPF16 8100035 18 18" FSVPF18 810003596 20 28 1 2 20" FSVPF20 810003616 22 29 1 2 22" FSVPF22 810003635 2 30 1 2 2" FSVPF2 810003655 26 31 1 2 Tall one Flashing *updated description* Use to create a weather-tight penetration where the vent pipe passes through a flat roof. Storm ollar required. When ordering Flashings for FasNSeal W2 product the flashing diameter and vent diameter are the same. ie. W2-3610 requires a FSVPF10. 12 SIZE ORDER # STOK # 3 FSF3 81000525 1 3 " FSF 810005258 5 1 3 5" FSF5 810005259 6 1 3 6" FSF6 810005260 1 3 " FSF 810005261 8 1 3 8" FSF8 810005262 9 1 3 SIZE ORDER # STOK # 9" FSF9 810005263 10 1 3 10" FSF10 81000526 11 1 3 12" FSF12 810005269 13 1 3 1" FSF1 81000520 15 1 3 16" FSF16 81000521 1 1 3 800-835-29 DuraVent 266

FasNSeal dapters Universal ppliance dapter SIZE ORDER # STOK # 3 FSU3 810003966 5 3 5 FSU 81000390 5 3 5 5 FSU5 81000392 5 3 5 6 FSU6 8100039 5 3 5 FSU 8100039 5 3 5 8 FSU8 810003980 5 3 5 SIZE ORDER # STOK # 9 FSU9 810003982 5 3 5 10 FSU10 81000398 5 3 5 12 FSU12 81000398 5 3 5 1 FSU1 810003990 5 3 5 16 FSU16 810003992 5 3 5 Universal ppliance dapter w/ Test Port *updated order #s* 6¼" SIZE ORDER # STOK # 3 FSUTP03 81000396 FSUTP0 81000391 5 FSUTP05 81000393 6 FSUTP06 81000395 FSUTP0 81000398 8 FSUTP08 810003981 SIZE ORDER # STOK # 9 FSUTP09 810003983 10 FSUTP10 810003985 12 FSUTP12 810003988 1 FSUTP1 810003991 16 FSUTP16 810003993 Universal ppliance dapter w/ ondensate Drain SIZE ORDER # STOK # 3 FSUD03 81000011 10 5 8 FSUD0 810003968 10 5 8 Universal ppliance dapter w/ ondensate Drain and ack Flow Preventer SIZE ORDER # STOK # FSUDFP0 810003969 11 5 8 21 DuraVent www.duravent.com

dapters FasNSeal W2 ppliance dapter SIZE ORDER # STOK # 3 W2-3 81000399 5 3 6 W2-810003996 5 3 6 5 W2-5 810003998 5 3 6 6 W2-6 81000000 5 3 6 W2-81000002 5 3 6 8 W2-8 81000005 5 3 6 9 W2-9 81000006 5 3 6 10 W2-10 81000008 5 3 6 12 W2-12 81000010 5 3 6 1 W2-1 81000012 5 3 6 16 W2-16 8100001 5 3 6 W2 ppliance dapter w/ Test Port 6¼" SIZE ORDER # STOK # 3" W2-TP03 810003995 " W2-TP0 81000399 5" W2-TP05 810003999 6" W2-TP06 81000001 " W2-TP0 81000003 8" W2-TP08 81000005 SIZE ORDER # STOK # 9" W2-TP09 8100000 10" W2-TP10 81000009 12" W2-TP12 81000011 1" W2-TP1 81000013 16" W2-TP16 81000015 Metric Male ppliance dapters *updated offering* SIZE ORDER # STOK # 19 mm FS-19-6F 8100055 6 158 mm FS-158-6F 81000016 6 19 mm FS-19-8F 8100001 6 250 mm FS-250-10F 81000018 6 De Dietrich GT Series ppliance dapter SIZE ORDER # STOK # FSU 8100039 5 3 5 8 FSU8 810003980 5 3 5 10 FSU10 81000398 5 3 5 12 FSU12 81000398 5 3 5 800-835-29 DuraVent 22

PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. hloride free, environmentally safe. Listed to UL-S636.

Specifications pplications PolyPro is a polypropylene vent pipe for use with NSI ategory II and IV gas-burning appliances, including highefficiency water heaters, condensing boilers and warm air furnaces. PolyPro is listed by Intertek to the UL S636 standard in anada as a lass II, II and II vent system suitable for exhaust temperatures up to 230 F / 110, and a maximum positive pressure of 15 in-w.c. Materials and onstruction *updated* Rigid pipe constructed of 2.2mm (minimum) thick polypropylene. Flex is double-wall polypropylene. EPDM or optional Viton Gaskets learances 0 clearance to combustibles for exhaust temperatures up to 19 F / 90, and 0 clearance for vertical installations up to exhaust temperatures of 230 F / 110 and ¼ / 6mm clearance to combustibles for horizontal installations at exhaust temperatures up to 230 F / 110. PolyPro concentric vent system components, including concentric Horizontal Termination and Vertical Termination, are listed at 0 clearance to combustibles for exhaust temperatures up to 230 F / 110. Diameters 2" (60mm), 3" (80mm), " (100mm), 5" (130mm), 6" (150mm), and 8" (200mm). PolyPro *updated* PolyPro and PV/PV: PV pipes are commonly used for venting water heaters, condensing boilers and warm air furnaces, yet PV was never designed for such use. n environmentally safe and engineered alternative for condensing gas appliances is PolyPro. Engineered for venting, it is 100% recyclable; contains no toxic or carcinogenic materials, chlorides, or heavy metals; and is also easier and faster to install then PV, saving the contractor time and money. PolyPro does not release hazardous gases during combustion and has been used safely throughout Europe since the early 1990s. Polypropylene has a higher operating temperature limit of 230 F/110 (PV is 19 F/65 max and PV is 19 F/90 ). PolyPro is engineered with a corrosion-free, condensation management system. PolyPro Flex PolyPro Flex through Vent as a hase: Retrofit venting for new, high-efficiency appliances. When replacing a mid-efficiency appliance with a new condensing 90+ appliance, you can use the existing vent (any brand) as a chase for the new appliance with PolyPro. The perfect solution for utilizing the Vent already in place, use the convenient pull cone to insert double-wall PolyPro Flex through the Vent pipe and terminate in either a two pipe or single pipe system. t the other end is the unique Vent/PolyPro Support ap, allowing for the connection of flex to rigid PolyPro lengths and elbows to finish the installation. Terminations DuraVent s concentric PolyPro vertical terminations are lab tested to handle harsh weather and remain icicle free in freezing temperatures. ir circulation and weather conditions like rain, wind and ice have the potential to reduce the efficiency of a unit's performance and the operation of its venting system. Listings Listed with the appliance in the US and anada, check with appliance manufacturer. Intertek / ETL listed to UL S636 Listed as a lass II, II, and II vent system. Tested and listed by a major testing agency, such as S. PolyPro complies with LEED credit IEQc.1 on VO limits. PolyPro is approved by the Massachusetts Plumbers oard. pproval code G1-0811-2.

PolyPro Single-Wall Venting System lack UV Resistant Tee Use as a termination. Made of UV resistant polypropylene. Gasket not included. Order ird Guard Screen to protect opening. SIZE ORDER # STOK # 2 60mm 2PPS-T 81000106 180mm 3 80mm 3PPS-T 8100015 8 200mm 100mm PPS-T 81000188 8 11 16 220mm lack UV Resistant Termination Tee *new product offering* Use as a termination. Manufactured with two female ends to accept ird Screen on both ends. Use bird screen to protect openings. Made of UV resistant polypropylene. SIZE ORDER # STOK # 6 150mm 6PPS-TT 8100055 lack Wall Plate Use to trim wall penetration. Painted black metal with gasket. SIZE ORDER # STOK # 2 60mm 2PPS-WP 81000112 3 80mm 3PPS-WP 81000152 100mm PPS-WP 81000195 lack Wall Plate for Twin Pipes Use to trim wall penetration when using two pipes. Painted black metal with gasket. SIZE ORDER # STOK # 2 60mm 2PPS-WPT 81000113 2 60mm 11 /10" 29mm 8 ½" 216mm 3 80mm 3PPS-WPT 81000153 3 80mm 11 /10" 29mm 8 ½" 216mm 100mm PPS-WPT 81000196 100mm 12 /10" 323mm 8 ½" 216mm Tee with Drain ap Use to manage condensates at the bottom of a vertical run. SIZE ORDER # STOK # SIZE ORDER # STOK # 2 60mm 2PPS-TD 8100010 5 130mm 5PPS-TD 81000229 3 80mm 3PPS-TD 8100016 6 150mm 6PPS-TD 81000263 100mm PPS-TD 81000189 8 200mm 8PPS-TD 8100029 289 DuraVent www.duravent.com

Single-Wall Venting System PolyPro Increaser Use to transition the vent system to a larger diameter. Install in vertical orientation. SIZE ORDER # STOK # 2" - 3" 60-80mm 2PPS-X3 81000108 5 16 110mm 3-80 - 100mm 3PPS-X 810001 5 16 110mm - 5 100-130mm PPS-X5 81000190 5 16 110mm 5-6 130-150mm 5PPS-X6 81000230 5 16 110mm 6-8 150-200mm 6PPS-X8 8100026 5 ¾" 15mm ppliance dapter for PV Pipe Use to connect PolyPro vent system to an appliance outlet. Has a double female adapter. One end accepts PV male pipe and the other accepts PolyPro male pipe. No adapter connector and/or locking band required. SIZE ORDER # STOK # 3 80mm 3PPS-D-M 81000169 100mm PPS-D-M 8100010 ppliance dapter for PV oupler *updated description* Use to adapt rigid PolyPro pipe length to the inside of the PV/ PV coupler or other plastic appliance outlet. Must be used with dapter onnector for flue gas. SIZE ORDER # STOK # SIZE ORDER # STOK # 2 60mm 2PPS-D 8100009 100mm PPS-D 8100019 3 80mm 3PPS-D 81000136 Female ppliance dapter Use to connect PolyPro to a nominal sized pipe with a smooth male end outlet. No adapter connector and/or locking band required. Hose clamps on both ends. SIZE ORDER # STOK # 6 150mm FSU6-6PP 81000283 5 15/16" 151mm 6" 150mm 5" 130mm 8 200mm FSU3-3PP 81000312 15/16" 199mm 8" 200mm 5" 130mm 800-835-29 DuraVent 290

Single-Wall Venting System PolyPro Increaser Use to transition the vent system to a larger diameter. Install in vertical orientation. SIZE ORDER # STOK # 2" - 3" 60-80mm 2PPS-X3 81000108 5 16 110mm 3-80 - 100mm 3PPS-X 810001 5 16 110mm - 5 100-130mm PPS-X5 81000190 5 16 110mm 5-6 130-150mm 5PPS-X6 81000230 5 16 110mm 6-8 150-200mm 6PPS-X8 8100026 5 ¾" 15mm ppliance dapter for PV Pipe *new name and description* Use to connect PolyPro vent system to an appliance outlet. Has a double female adapter. One end accepts PV male pipe and the other accepts PolyPro male pipe. No adapter connector and/or locking band required. SIZE ORDER # STOK # 3 80mm 3PPS-D-M 81000169 100mm PPS-D-M 8100010 ppliance dapter for PV oupler *new name and description* Use to adapt rigid PolyPro pipe length to PV/PV coupler or other plastic appliance outlet. Must be used with dapter onnector for flue gas. SIZE ORDER # STOK # SIZE ORDER # STOK # 2 60mm 2PPS-D 8100009 100mm PPS-D 8100019 3 80mm 3PPS-D 81000136 Female ppliance dapter *new name and description* Use to connect PolyPro to a nominal sized pipe with a smooth male end outlet. No adapter connector and/or locking band required. Hose clamps on both ends. SIZE ORDER # STOK # 6 150mm FSU6-6PP 81000283 5 15/16" 151mm 6" 150mm 5" 130mm 8 200mm FSU3-3PP 81000312 15/16" 199mm 8" 200mm 5" 130mm 800-835-29 DuraVent 290

PolyPro Single-Wall Venting System Male PV ppliance dapter Use to connect PolyPro vent system to a standard stainless steel appliance outlet equipped with an integrated hose clamp and gasket. Must be used with dapter onnector for flue gas, unless a clamp is supplied on the appliance outlet. Same O.D. as PV. SIZE ORDER # STOK # 3 80mm 3PPS-03PVM-3PPF 8100016 3 3/16" 81mm 3 ½" 89mm 6 13/16" 13mm 100mm PPS-0PVM-PPF 8100020 " 102mm ½" 11mm 6 13/16" 13mm 6 150mm 6PPS-06PVM-6PPF 81000281 5 3/16" 132mm 5 9/16" 11mm 6 13/16" 13mm 8 200mm 8PPS-08PVM-8PPF 81000310 6" 152mm 6 5/8" 168mm 6 15/16" 16mm Female PV ppliance dapter *updated description* ccepts PolyPro Fits Over PV Fits Inside PV Use to directly connect PolyPro to a male PV Pipe appliance outlet. Seals on the O.D. of the PV pipe and has a clamp. No adapter connector and/or locking band required. SIZE ORDER # STOK # 5 130mm 5PPS-05PVF-5PPF 810002 5" 130mm 5 11/16" 1mm 6 150mm 6PPS-06PVF-6PPF 81000280 5 15/16" 151mm 6 11/16" 10mm 8 200mm 8PPS-08PVF-8PPF 81000309 15/16" 132mm /8" 200mm FasNSeal dapter Use to transition from FasNSeal vent system to PolyPro vent system. an be used as an appliance adapter or inline. No locking band required. SIZE ORDER # STOK # 3 80mm FS-03M-2PPF 8100010 2 3/8" 60mm 3" 6mm 6 1/8" 156mm 3 80mm FS-03M-3PPF 81000169 3 1/8" 9mm 3" 6mm 5 15/16" 151mm 100mm FS-0M-PPF 81000209 " 100mm " 100mm 5 15/16" 151mm 5 130mm FS-05M-5PPF 810002 5 3/16" 132mm 5" 130mm 5 15/16" 151mm 6 150mm FS-06M-6PPF 81000030 5 15/16" 151mm 6" 150mm 6" 150mm 18mm FS-0M-6PPF 8100063 6 1/8" 156mm 6 5/16" 160mm " 18mm 8 200mm FS-08M-8PPF 81000031 8" 200mm 8" 200mm 6" 150mm PolyPro to FasNSeal dapter Use to transition from PolyPro vent system to FasNSeal vent system or to connect a metric appliance to FasNSeal. an be used as an appliance adapter or inline. Locking band required for 3" - " diameters, recommended for 5" - 8" diameters. SIZE ORDER # STOK # 3 80mm 3PPS-DM-03FNSF 81000168 3" 80mm 3 1/8" 9mm 3 13/16" 9mm 100mm PPS-DM-0FNSF 81000208 " 100mm 3 1 5/16" 99mm 5 15/16" 151mm 5 130mm 5PPS-DM-05FNSF 8100026 5" 130mm 5 1/8" 131mm 5 15/16" 151mm 6 150mm 6PPS-DM-06FNSF 81000282 6" 150mm 5 15/16" 151mm " 18mm 8 200mm 8PPS-DM-08FNSF 81000311 8" 200mm /8" 199mm " 18mm 291 DuraVent www.duravent.com

PolyPro Single-Wall Venting System Male PV ppliance dapter *new name and description* Use to connect PolyPro vent system to a standard stainless steel appliance outlet equipped with an integrated hose clamp and gasket. Must be used with dapter onnector for flue gas, unless a clamp is supplied on the appliance outlet. Same O.D. as PV. SIZE ORDER # STOK # 3 80mm 3PPS-03PVM-3PPF 8100016 3 3/16" 81mm 3 ½" 89mm 6 13/16" 13mm 100mm PPS-0PVM-PPF 8100020 " 102mm ½" 11mm 6 13/16" 13mm 6 150mm 6PPS-06PVM-6PPF 81000281 5 3/16" 132mm 5 9/16" 11mm 6 13/16" 13mm 8 200mm 8PPS-08PVM-8PPF 81000310 6" 152mm 6 5/8" 168mm 6 15/16" 16mm Female PV ppliance dapter *new name and description* ccepts PolyPro Fits Over PV Fits Inside PV Use to connect PolyPro to a male PV Pipe appliance outlet. No adapter connector and/or locking band required. SIZE ORDER # STOK # 5 130mm 5PPS-05PVF-5PPF 810002 5" 130mm 5 11/16" 1mm 6 150mm 6PPS-06PVF-6PPF 81000280 5 15/16" 151mm 6 11/16" 10mm 8 200mm 8PPS-08PVF-8PPF 81000309 15/16" 132mm /8" 200mm FasNSeal dapter *new name and description* Use to transition from FasNSeal vent system to PolyPro vent system. an be used as an appliance adapter or inline. No locking band required. SIZE ORDER # STOK # 3 80mm FS-03M-2PPF 8100010 2 3/8" 60mm 3" 6mm 6 1/8" 156mm 3 80mm FS-03M-3PPF 81000169 3 1/8" 9mm 3" 6mm 5 15/16" 151mm 100mm FS-0M-PPF 81000209 " 100mm " 100mm 5 15/16" 151mm 5 130mm FS-05M-5PPF 810002 5 3/16" 132mm 5" 130mm 5 15/16" 151mm 6 150mm FS-06M-6PPF 81000030 5 15/16" 151mm 6" 150mm 6" 150mm 18mm FS-0M-6PPF 8100063 6 1/8" 156mm 6 5/16" 160mm " 18mm 8 200mm FS-08M-8PPF 81000031 8" 200mm 8" 200mm 6" 150mm PolyPro to FasNSeal dapter *new name and description* Use to transition from PolyPro vent system to FasNSeal vent system or to connect a metric appliance to FasNSeal. an be used as an appliance adapter or inline. Locking band required for 3" - " diameters, recommended for 5" - 8" diameters. SIZE ORDER # STOK # 3 80mm 3PPS-DM-03FNSF 81000168 3" 80mm 3 1/8" 9mm 3 13/16" 9mm 100mm PPS-DM-0FNSF 81000208 " 100mm 3 1 5/16" 99mm 5 15/16" 151mm 5 130mm 5PPS-DM-05FNSF 8100026 5" 130mm 5 1/8" 131mm 5 15/16" 151mm 6 150mm 6PPS-DM-06FNSF 81000282 6" 150mm 5 15/16" 151mm " 18mm 8 200mm 8PPS-DM-08FNSF 81000311 8" 200mm /8" 199mm " 18mm 291 DuraVent www.duravent.com

PPS-WSM 3 5 6 8.39 5.1 6.36.15 9.12 5.25 5.6 6..63 9.62 Single-Wall Venting System PolyPro Wall Strap - metal Use to support for offsets, vertical and horizontal runs. Wall Strap legs can be rotated 360 to conceal screw. ccepts 1/ all-thread. vailable in galvanized or stainless steel metals. Supporting Wall Straps are required at least every 10 feet 3 meters for vertical vent pipe sections, and horizontal or sloped sections of vent pipe require one supporting Wall Strap for each pipe section. SIZE GLVNIZED ORDER # STOK # 2 60mm 2PPS-WSM 81000110 3 5/8" 92mm /8"" 12mm 3 80mm 3PPS-WSM 81000150 3 8 112mm 5 1 133mm 100mm PPS-WSM 81000193 5 1 8 130mm 5 5 8 13mm 5 130mm 5PPS-WSM 81000232 6 3 8 162mm 6 3 11mm 6 150mm 6PPS-WSM 81000266 1 8 181mm 5 8 19mm 8 200mm 8PPS-WSM 81000296 9 1 8 232mm 9 5 8 25mm SIZE STINLESS STEEL ORDER # STOK # 2 60mm 2PPS-WSM-SS 81000111 3 5/8" 92mm /8" 12mm 3 80mm 3PPS-WSM-SS 81000151 3 8 112mm 5 1 13mm 100mm PPS-WSM-SS 8100019 5 1 8 130mm 5 5 8 13mm 5 130mm 5PPS-WSM-SS 81000233 6 3 8 162mm 6 3 11mm 6 150mm 6PPS-WSM-SS 8100026 1 8 181mm 5 8 19mm 8 200mm 8PPS-WSM-SS 8100029 9 1 8 232mm 9 5 8 25mm Locking and Use to secure two sections of pipe together. Required to comply with UL-S636 listed installations for 2 to diamaters. Locking ands optional for 5 diameter. SIZE ORDER # STOK # SIZE ORDER # STOK # 2 60mm 2PPS-L 8100012 100mm PPS-L 81000206 3 80mm 3PPS-L 8100012 5 130mm 5PPS-L 8100021 Locking and lamp *updated offering* Use to secure two sections of pipe together. Locking ands optional for 5-8" diameters. Use to secure two large diameter sections of PolyPro pipe together. Typically used in vertical installations. SIZE ORDER # STOK # 2 60mm 2PPS-L 8100016 2 3/8" 60mm 2 ½" 6mm 3 80mm 3PPS-L 810001 3 1/8" 80mm 2 ½" 6mm 100mm PPS-L 8100018 " 100mm 2 ½" 6mm 5 130mm 5PPS-L 8100022 5 1/8" 130mm 2 1 2 6mm 6 150mm 6PPS-L 8100028 6 1/8" 156mm 2 1 2 6mm 8 200mm 8PPS-L 81000306 8 1/8" 20mm 2 1 2 6mm 800-835-29 DuraVent 292

PolyPro Single-Wall Venting System Vertical Termination ap Kit - oncentric Use for concentric vertical terminations. Includes 2 appliance adapters and co-linear adapter. lack or terra-cotta cap. UV resistant. SIZE LK ORDER # STOK # 2 x 60 x 100mm 2PPS-VK 8100008 18 60mm 50 1 1280mm ¾" 121mm 3 x 5 80 x 125mm 3PPS-VK 81000086 23 580mm 53 1 135mm ¾" 121mm x 6 100 x 150mm PPS-VK 81000088 23 580mm 68 1 135mm 5 ½" 10mm SIZE TERR-OTT ORDER # STOK # 2 x 60 x 100mm 2PPS-VK-T 81000085 18 60mm 50 1 1280mm ¾" 121mm 3 x 5 80 x 125mm 3PPS-VK-T 8100008 23 580mm 53 1 135mm ¾" 121mm x 6 100 x 150mm PPS-VK-T 81000089 23 580mm 68 1 135mm 5 ½" 10mm Horizontal Termination Kit - oncentric *updated description* MX LENGTH Use for concentric horizontal terminations. Includes 2 appliance adapters, white wall plate, white firestop, and co-linear adapter. White Termination with ird Guard Screen. UV resistant. Inner plate is 8 5/8 (220mm) square, outer plate is 9 /16 (20mm) square for all flue sizes. SIZE ORDER # STOK # 2-60 - 100mm 2PPS-HK 81000081 13 ¾ 350mm ¾" 121mm 3 x 5 80-125mm 3PPS-HK 81000082 13 330mm ¾" 121mm x 6 100-150mm PPS-HK 81000083 13 ¾ 350mm 5 ½" 10mm ird Guard Screen Use to protect venting system from birds and rodents. Position inside pipe in place of gasket. Stainless steel. Pack of 6. SIZE ORDER # STOK # SIZE ORDER # STOK # 2 60mm 2PPS-G 8100031 100mm PPS-G 8100031 3 80mm 3PPS-G 81000355 6" 150mm 6PPS-G 8100026 EPDM Replacement Gasket Use as a replacement gasket for rigid PolyPro products. Pack of 12. SIZE ORDER # STOK # SIZE ORDER # # STOK # 2 60mm 2PPS-G 8100012 5 130mm 5PPS-G 8100023 3 80mm 3PPS-G 8100016 6 150mm 6PPS-G 8100022 100mm PPS-G 8100020 8 200mm 8PPS-G 81000303 Viton Replacement Gasket Use as a gasket for oil fuel appliances. SIZE ORDER # STOK # SIZE ORDER # STOK # 2 60mm 2PPS-GV 81000126 5 130mm 5PPS-GV 81000238 3 80mm 3PPS-GV 81000165 6 150mm 6PPS-GV 8100023 100mm PPS-GV 81000205 8 200mm 8PPS-GV 8100030 295 DuraVent www.duravent.com