PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install
|
|
- Daniella Berry
- 6 years ago
- Views:
Transcription
1 PolyPro : For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install
2 Being Green, Being Responsible. DuraVent looks for feasible ways of doing business in an ecologically sound way. In manufacturing we use water based paints. Our reverse osmosis system recycles 90% of the water used in the paint line. We buy recycled metals for all our products when available, and recycle waste metals. Factory skylights reduces heavy load needs for electric lighting during daylight hours. In the office, paperless invoicing is now standard. Paperless communications to customers are sent via electronic newsletters or , and we recycle office paper waste. Kaizen (Japanese for improvement ) refers to the practice of focusing on continuous improvement in manufacturing activities. By improving standardized activities and processes, Kaizen aims to eliminate waste. Since 1998, DuraVent has reduced manufacturing waste in its plant by 30% through Kaizen practices. DuraVent is a member of the US Green Building Council,(USGBC) a non-profit organization dedicated to sustainable building design and construction, and developers of the LEED building rating system.
3 PolyPro PolyPro For venting, DuraVent s PolyPro is the proven, healthy, environmentally safe alternative to PVC. Specifically designed for venting, it is also 100% recyclable, it contains no toxic or carcinogenic materials, such as chlorides, or heavy metals. Plus, it does not release hazardous gases during combustion. PolyPro has been used for venting throughout Europe for over fifteen years. PolyPro has a higher operating temperature than PVC of 248 F. No glues or solvents are needed at connections. For condensing gas fired appliances. ULC-S636 Listed. 3
4 Our History The M&G Group acquired Simpson DuraVent September 1, M&G DuraVent, Inc, a member of the M&G Group, is one of 13 companies in the privately held consortium. M&G ( was founded in 1932 and is headquartered in the Netherlands. The M&G Group produces a wide range of flue and vent products in aluminum, stainless steel and plastic. It is the largest supplier of engineered venting systems for the high-efficiency heating market in Europe. All M&G companies, including DuraVent, are 100% focused on developing, manufacturing and marketing only flue and ventilation systems. Since 1958, DuraVent has been a leading manufacturer of Gas Vent and Chimney products in the US. In 1982, DuraVent was purchased by Simpson Manufacturing. In 2008 DuraVent acquired both the Ventinox product line from America Boa, and ProTech Systems, the highly respected manufacturer of Hearth, HVAC and PHC products. With a broad range of engineered venting products, DuraVent has earned its reputation as the industry leader by offering innovative, safe, professional products for the HVAC and Hearth markets. M&G DuraVent is dedicated to one thing...focusing on the design and manufacture of venting products. As experts in this industry, our team is passionate about creating innovative, quality products. We invest in equipment with the latest technology to develop and test venting products that are engineered to one standard, excellence. All measuring equipment is calibrated to the same levels as used by testing agencies, and are compliant with ISO 17025, the test laboratory standard. Wind Tunnel Laboratory The wind tunnel lab allows us to gather precise data with 180 degrees of measurement on terminations. All data is anaylized for product performance under rigorous conditions before going to market. Appliance Testing M&G DuraVent offers appliance testing for OEM's. Rain Testing M&G labs test the vapor/moisture barrier of products by subjecting them to extreme rain and wind conditions. These tests are more stringent than required in the US and Canada. Climate Testing M&G labs have developed a patented ice testing system in the climate room. Tests run to -4 degrees F. PolyPro terminations are engineered to remain icicle free. OEM Product Development M&G DuraVent engineeers are expertly skilled to develop venting components to OEM specs. To satisfy specific venting requirements, DuraVent has the experience to provide custom design, prototyping and testing of vent systems and components engineered to the demands of specific appliances. 4 DuraVent
5 PolyPro PolyPro is a polypropylene ULC-S636 Gas Vent - BH, Class II (248 F max) venting system for the North American continent. PolyPro is engineered for use with category II & IV condensing appliances, is corrosion resistant and utilizes gaskets that enable rapid and adhesive free assembly. Available in 2, 3, 4, 5, 6 and 8 diameters. PVC pipes are commonly used for venting water heaters, condensing boilers and warm air furnaces, yet PVC was never designed for such use. No other plastic contains or releases as many dangerous chemicals. It poses dangerous environmental health hazards in its manufacture, product life, and disposal. PVC is unfit for safe venting. An environmentally safe alternative is PolyPro, new to the U.S. and Canadian market by DuraVent, for condensing gas appliances. Engineered for venting, it is 100% recyclable, contains no toxic or carcinogenic materials, chlorides, or heavy metals, as found in PVC. It does not release hazardous gases during combustion, and has been used safely throughout Europe for over fifteen years. PolyPro has a higher operating temperature of 248degrees ( PVC is 149 degrees max). PolyPro is engineered with a corrosion-free, condensation management system. DuraVent s PolyPro is available for solutions requiring single-wall, concentric, manifold and other engineered uses. Terminations DuraVent s PolyPro terminations are lab tested to handle harsh weather and remain icicle free in freezing temperatures. Air circulation and weather conditions like rain, wind and ice have the potential to reduce the efficiency of a units performance and the operation of it's venting system. M&G DuraVent has designed its terminations for a tight, leak-free system that does not allow icicle formations DuraVent 5
6 PolyPro Single Wall and Flex Specifications ULC S636 System Applications PolyPro is a polypropylene venting system for use with ULC-S636 Gas Vent - BH, Class II (248 F max) venting system for the North American continent. PolyPro is engineered for use with category II & IV condensing appliances and heating equipment, including tankless water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. Materials and Construction Rigid pipe constructed of 2.2mm (minimum) thick polypropylene. Flex is double wall polypropylene. EPDM or Viton gaskets. Diameters 2", 3", 4", 5", 6" and 8" Listings ULC-S636 Listed Warnock-Hersey Warranty 10 years ISO 9001 Registered by GasTec 6 DuraVent
7 PolyPro Typical Installation, Single-Wall Typical Installation, Flex Skyline Vertical Termination Flashing Vent Length Elbow Support Bracket A polypropylene vent system for condensing appliances that offers superior environmental, performance, and installation advantages over PVC / CPVC. Environmental Advantages 100% recyclable. No leaching or off-gassing of heavy metals or carcinogens. Releases only oxygen and carbon dioxide when burned. Resistant to aromatic hydrocarbons generated by gas combustion. Resistant to acids and bases. No chlorides in PolyPro, unlike PVC. Performance Advantages: Ideal for all condensing appliances. ULC S636. Extra thick wall means it is more stable & secure. Tight seal at every joint...expands and contracts. with weather and temperature changes, so there is no flexing or cracking in the venting. Terminations remain icicle free in freezing weather. Interior of 90 elbows are 88 to prevent standing condensation. Higher sustained operating temperatures than PVC. Corrosion resistant. Installation Advantages: No flammable, messy or harmful glues, cements or solvents needed at connections. No wait for glue curing time during installation. Screws into studs for a sturdy and secure brace. Time saving wall bracket clips quickly and easily to PolyPro pipe. Lightweight and easy to install. Gasketed connections make easy removal and replacement of components DuraVent 7
8 PolyPro Single-Wall Venting for Condensing Appliances Horizontal Termination Kit Use for horizontal terminations. White nose. Includes 2 appliance adapters, white wall plate, white firestop, ski boot. SIZE STOCK # A 2 2PPS-HK PPS-HK PPS-HK 13 MAX LENGTH A Vertical Termination Cap Kit A Use for vertical terminations. Includes 2 appliance adapters, ski boot. Choose black or terra-cotta cap. SIZE BLACK CAP TERRA-COTTA CAP A B 2 2PPS-VK 2PPS-VK-TC PPS-VK 3PPS-VK-TC PPS-VK 4PPS-VK-TC B 8 DuraVent
9 PolyPro Single-Wall Pipe Ø Use to vent condensing appliances, including gas-fueled condensing water heaters and high-efficiency warm air furnaces. Listed to ULC S636. LENGTH SIZE PPS-12 2PPS-36 2PPS PPS-12 3PPS-36 3PPS PPS-12 4PPS-36 4PPS PPS-12 5PPS-36 5PPS PPS-12 6PPS-36 6PPS-72 Adjustable Pipe Use to add length to straight length of PolyPro pipe. Slips over standard single-wall pipe length PPS-AVL 5 5PPS-AVL 3 3PPS-AVL 6 6PPS-AVL 4 4PPS-AVL 8 8PPS-AVL SIZE PPS-40 2PPS-75 Test Port Ø Use to test for proper applaince operation without penetrating or disconnecting the vent wall PPS-TP 5 5PPS-TP 3 3PPS-TP 6 6PPS-TP 4 4PPS-TP 8 8PPS-TP DuraVent 9
10 Appliance Adapter, PVC to PolyPro Use to connect rigid PolyPro pipe length to PVC on an appliance. SIZE STOCK # 2 2PPS-AD 3 3PPS-AD 4 4PPS-AD 45º Elbow Offsets obstructions as needed. A B SIZE STOCK # A B SIZE STOCK # A B 2 2PPS-E PPS-E PPS-E PPS-E PPS-E PPS-E º Elbow B Offsets obstructions as needed. A SIZE STOCK # A B SIZE STOCK # A B 2 2PPS-E PPS-E PPS-E PPS-E PPS-E PPS-E Condensate Drain Use to properly manage corrosive condensates common with high efficiency gas appliances. A 87º SIZE STOCK # HEIGHT SIZE STOCK # HEIGHT 2 2PPS-CD 7 5 5PPS-CD 7 3 3PPS-CD 7 6 6PPS-CD 7 4 4PPS-CD 7 8 8PPS-CD 23 4 Tee with Cap Use for a 90 offset or to combine connections from two or more appliances into a common vent. SIZE STOCK # 2 2PPS-T 3 3PPS-T 4 4PPS-T 10 DuraVent
11 PolyPro Tee Cap Drain Use instead of Tee Cap to manage condenstaes at the bottom of a vertical run. 2 2PPS-TCD 5 5PPS-TCD 3 3PPS-TCD 6 6PPS-TCD 4 4PPS-TCD 8 8PPS-TCD Increaser ØC ØB A Use to increase vent diameter. SIZE STOCK # A B C 2-3 2PPS-X PPS-X PPS-X PPS-X PPS-X Firestop Spacer Use when penetrating floor levels. Two pieces for ease of use. 2 2PPS-FS 5 5PPS-FS 3 3PPS-FS 6 6PPS-FS 4 4PPS-FS 8 8PPS-FS Wall Strap Use to support vertical and horizontal runs. PolyPro version for 2-4 diameter pipe. Aluminum strap for 5-8 diameter pipe. 2 2PPS-WS 5 5PPS-WS 3 3PPS-WS 6 6PPS-WS 4 4PPS-WS 8 8PPS-WS DuraVent 11
12 Flat Roof Flashing Use to weather proof penetration of vent through the roof. 2 2PPS-FF 5 5PPS-FF 3 3PPS-FF 6 6PPS-FF 4 4PPS-FF 8 8PPS-FF Adjustable Roof Flashing, Aluminum 0 º - 25º Use to weather proof penetration of vent through the roof. Made of aluminum. Adjusts from 0-25 (0/12 to 5/12). SIZE STOCK # 2 2PPS-F5 3 3PPS-F5 4 4PPS-F5 Adjustable Roof Flashing, Polypropylene 25º - 45º Use to weather proof penetration of vent through the roof. Made of polypropylene. Adjusts from 25 to 45 (6/12 to 12/12). SIZE STOCK # 2 2PPS-F12 3 3PPS-F12 4 4PPS-F12 EPDM Replacement Gasket Use as a replacement gasket for rigid PolyPro products. 2 2PPS-GA 5 5PPS-GA 3 3PPS-GA 6 6PPS-GA 4 4PPS-GA 8 8PPS-GA 12 DuraVent
13 PolyPro Viton Replacement Gasket for Condensing Oil Appliances Use as a replacement gasket when using PolyPro products with condensing oil appliances. SIZE STOCK # 2 2PPS-GAV 3 3PPS-GAV 4 4PPS-GAV Locking Band Use to secure two pieces of pipe together. Required to comply with ULC-S636 listing. SIZE STOCK # 2 2PPS-LB 3 3PPS-LB 4 4PPS-LB DuraVent 13
14 PolyPro Flex Venting for Condensing Appliances Flex Chimney Lining Kit Use for a vertical flex lining system. Includes chimney cap, rigid flue vent, support brackets, flex connector, support elbow, wall plate and appliance adapter. Flex sold seperately. 2 2PPS-FK 4 4PPS-FK 3 3PPS-FK 5 5PPS-FK Flex Length Use to line masonry chimneys that vent condensing appliances. Double-wall construction. Standard sizes with custom lengths available. Can be cut to length. SIZE STOCK # LENGTH SIZE STOCK # LENGTH 2 2PPS-100F 100FEET 4 4PPS-100F 100FEET 3 3PPS-100F 100FEET 5 5PPS-100F 100FEET Chimney Cap Use to vertically terminate a flex system. 2 2PPS-FCT 4 4PPS-FCT 3 3PPS-FCT 5 5PPS-FCT 14 DuraVent
15 PolyPro Flex Male Adapter Use to connect PolyPro rigid pipe to PolyPro flex at the base of the system. 2 2PPS-FAM 4 4PPS-FAM 3 3PPS-FAM 5 5PPS-FAM Flex Female Adapter Use to terminate PolyPro flex lining system back to a rigid system. 2 2PPS-FAF 4 4PPS-FAF 3 3PPS-FAF 5 5PPS-FAF Flex Coupler Adapter Use to tightly connect one length of PolyPro flex to another. 2 2PPS-FAC 4 4PPS-FAC 3 3PPS-FAC 5 5PPS-FAC Support Bracket Use to support PolyPro Flex from top of masonry chimney. 2 2PPS-FSB 4 4PPS-FSB 3 3PPS-FSB 5 5PPS-FSB Spacer Use to center PolyPro flex. Universal for all diameters. Simple installation and ratchet adjustment. 2 2PPS-S 4 4PPS-S 3 3PPS-S 5 5PPS-S DuraVent 15
16 Support Elbow, Extended A Use the extended support elbow to stabilize the vertical termination. Extended horizontal length can be trimmed to size. Includes supporting assembly and mounting channel. SIZE STOCK # A SIZE STOCK # A 2 2PPS-SE90X PPS-SE90X PPS-SE90X 22 ¼ 5 5PPS-SE90X Chimney Support Use to support flex liner system against a masonry wall. 2 2PPS-SUP 4 4PPS-SUP 3 3PPS-SUP 5 5PPS-SUP Wall Plate Use to trim wall penetration. White. 2 2PPS-WP 4 4PPS-WP 3 3PPS-WP 5 5PPS-WP Viton Replacement Gasket, Flex Use as a replacement gasket for PolyPro flex products. 2 2PPS-GAF 4 4PPS-GAF 3 3PPS-GAF 5 5PPS-GAF Flex Puller Use with the provided rope to guide PolyPro flex lengths down masonry chimney. 2 2PPS-FP 4 4PPS-FP 3 3PPS-FP 5 5PPS-FP 16 DuraVent
17 PolyPro Additional PolyPro products and components may be available since this catalog was published. Contact DuraVent's customer service department for more information DuraVent 17
18 PolyPro Concentric Specifications Applications Concentric venting system for use with ULC-S636 Gas Vent - BH, Class II (248 F max) venting system for the North American continent. PolyPro is engineered for use with category II & IV condensing appliances and heating equipment, including tankless water heaters, high-efficiency water heaters, condensing boilers and warm air furnaces. Advantages of Concentric A concentric (or direct-vent, or two-pipe) system maintains indoor air quality by reducing drafts with one penetration, and allows for better humidity level control inside a dwelling. Concentric venting brings to the heating appliance outdoor air as combustion air through an air-tight, sealed system that is safe. Materials and Construction Inner pipe a minimum of 2.2mm thick polypropylene pipe. Exterior pipe made of galvalume. Diameters 3" inner with 5" outer wall. Listings ULC-S636 Warnock-Hersey 18 DuraVent
19 PolyPro Typical Installation, Concentric Skyline Vertical Termination Flashing PolyPro Concentric... DuraVent's concentric vent systems incorporate a PolyPro inner with a metal outer. All the advantages of a polypropylene inner encased in a strong, galvalume outer pipe. Available as 3"x5". Elbow Concentric Vent Length The Concentric System includes: Lengths Elbows Horizontal Termination Vertical Termination Concentric Appliance Adapter DuraVent 19
20 M&G DuraVent, Inc. PO Box 1510 Vacaville, CA Fax: 'LEED' and USGBC logo is a trademark owned by the U.S. Green Building Council and is used by permission. This catalog is made from recycled materials. Please remember to recycle. L275 1/ M&G DuraVent, Inc. PolyPro is one of M&G DuraVent s GreenVent line of products.
ULC S636 System. PolyPro. PolyPro Flex. Terminations
PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Chloride free, environmentally safe. Listed to ULC-S636. Specifications pplications PolyPro is a polypropylene
More informationDURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationZ-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric
Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Concentric Z-Flex Joins Forces with Cox Geelen Z-Flex North
More informationThe intelligent alternative for flue gas venting systems
The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason
More informationPelletVent Multi-fuel venting system. UL 641.
PelletVent Multi-fuel venting system. UL 641. Specifications Applications PelletVent is designed for venting of pellet stoves and inserts. Consult appliance manual for additonal requirements. Materials
More informationCVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.
VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. PelletVent venting system. Listed to UL 641, UL S609, and UL/ORD 441. Unitized venting system for DirectVent
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications Applications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationPelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney
PelletVent Pro horizontal Kit Kit includes: Round horizontal Cap, Wall Thimble, and Appliance Adapter. Pipe lengths not included. 4 Kit includes a 3-4 Appliance Adapter/Increaser, painted black. 3 3PVP-KHA
More informationPelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.
PelletVent Pro iofuel venting system. UL 641, ULC S609, and ULC/ORD C441. Specifications pplications PelletVent Pro is a venting system designed for stoves and inserts that use wood pellets and oil fuel.
More informationEasy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation
Easy to assemble Silicone gasket sealed Laser-welded seams Smooth joint connections 360 Lock-Tab secure rotation Evenly spaced inner and outer pipes Continuous column of air insulation Ultimate Pellet
More informationDuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.
DuraPlus HTC ll-fuel, double-wall chimney system. ULC S629. Specifications pplications DuraPlus HTC is a double-wall, all-fuel chimney system for both the U.S. and Canada for use with wood stoves; fireplaces;
More informationManual Addendum. This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N _0518
Manual Addendum This Addendum needs to be used in conjunction with the Evergreen Boiler Manual P/N 550-100-191_0518 ATTENTION to installers and homeowners of Evergreen boilers. KEEP THIS ADDENDUM WITH
More informationZ-DENS Polypropylene Vent Systems
Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Cascade Concentric Affirmed as replacement to comparable PVC
More informationVenting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y
Venting System For Pellet and Corn Stoves PelletVent Pro C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y ii PelletVent Pro For Stoves Burning Pellets & Corn Simpson
More informationFLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationGB162 Concentric Horizontal Vent Kit
GB162 Concentric Horizontal Vent Kit FOR BUDERUS GB162 SERIES BOILERS Installation Instructions 2 Concentric Horizontal Vent Kit Installation Manual Data subject to change Bosch Thermotechnology Corp.
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC
More informationSUBMITTAL RECORD. ULC S636 - PolyPro. Single-Wall Double-Wall Concentric Flex
SUMITTL RECORD ULC S636 - PolyPro Polypropylene vent pipe for use with NSI Category II and IV gas-burning appliances, including high efficiency water heaters, condensing boilers and warm air furnaces.
More informationINSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS
SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions Listed & Tested to UL641, ULC-S609, ULC/ORD C441 AMERIVENT Model PVP Pellet Pipe Plus Vent Connector for Pellet-Fuel Appliances and Other Low-Temperature Applications
More informationX-593 SOLID FUEL HEATING QUESTIONNAIRE
X-593 SOLID FUEL HEATING QUESTIONNAIRE CLEAR PHOTOGRAPHS & QUESTIONNAIRE REQUIRED FOR EACH INSTALLATION (UNITS & VENTS) NAME ADDRESS PHONE NO POLICY NO BROKER INSPECTED BY DATE GENERAL INSTALLATION QUESTIONS
More informationBy Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference
By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation
More informationZ-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS
Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS 3 & 4 SPECIAL STAINLESS STEEL VENTING SYSTEM FOR GAS BURNING APPLIANCES CATEGORY I, II, III, & IV TESTED AND LISTED BY UNDERWRITERS
More informationCombustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.
Combustion ir System Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641. DVL Double-wall interior close clearance stovepipe for connecting woodstoves to
More informationTYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES
INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES LISTED TO ULC-S609 & UL641 A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES
More informationCOMMON VENTING SYSTEM SUBMITTAL SHEET
COMMON VENTING SYSTEM SUBMITTAL SHEET Job Name: Location: Architect/Engineer: Wholesaler: Model No.: Notes: Total Vent Length: Total System Btu/h: FEATURES AND BENEFITS The Common Vent System provides
More informationInstallation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro
Installation Instructions PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
More informationSMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN
More informationSingle Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054
MC-CG-105 EN_892054 WARNING Installation Manual CoxDENS PPs Incorrect installation of Flue System and Components, or failure to follow installation instructions, can result in property damage or serious
More informationGOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3 venting Special gas vent system vent and combustion air supplement for 3 diameter venting. The following manufacturers AL29-4C Stainless Steel
More informationANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.
NY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution. Specialists in Flexible Z-FLEX has been providing flexible
More informationEXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE
THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE Chimney To determine what parts you need for your woodstove installation, try the
More informationDirect Exhaust Venting Kit Instructions
CONDENSING GAS BOILER 220/299/300/399 Direct Exhaust Venting Kit Instructions Evergreen 220/299/300/399 Kit part number 383-500-769 STOP! Read before proceeding Hazard definitions The following defined
More informationAdvanced Venting Systems
Advanced Venting Systems 1 Z-Vent Special Gas Vent 3 Flexible Vent Connector Systems 5 Aluminium Chimney Liner System 7 Stainless Steel Chimney Liner System 9 Oval Liner System / Advancing the Industry
More informationGWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions
GWS Gas-Fired Water Boilers Venting Manual Hazard definitions Contents Page Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal
More informationGOLD. Venting Supplement. Water Boiler Series 3 & 4. for 3" venting
GOLD GV Water Boiler Series 3 & 4 Venting Supplement for 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting. The following manufacturers AL29-4C Stainless Steel
More informationBDM Direct Vent systems are for use with direct vent gas fired appliances.
INSTALLATION INSTRUCTIONS Pro-Form DIRECT VENT SYSTEM Tested to ANSI Z21.88-2009 /CSA 2.33-2009 REPORT # 369-P-02b-6.5 Read through all venting and appliance instructions before beginning your installation.
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts Figure 92 Propane conversion kits and instructions Boiler model DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE The WM97+ maintenance kit includes components that
More informationVP Pellet Pipe. For pellet burning stoves. FEATURES
CATALOG VP Pellet Pipe For pellet burning stoves. Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. FEATURES Available in 3"
More informationInstallation Instructions
Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS
More informationGAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.
ODV-B GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont. N8A5E5 TABLE OF CONTENTS HORIZONTAL PIPING... PAGES 1-10 WARNINGS...
More information5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION
5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION These instructions apply to the Simpson Dura-Vent 5"x 8" Direct Vent System. This venting
More informationMitchell Metal Products, Inc.
Mitchell Metal Products, Inc. Mitchell Metal Products Kosciusko, Mississippi Established 1924 H i g h w a y 1 2 E P. O. B o x 7 8 9 K o s c i u s k o, M S 3 9 0 9 0 O f f i c e : 6 6 2-2 8 9-7 11 0 o r
More informationVENTING APPLICATION GUIDE
VENTING APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers
More informationH35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)
H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74
More informationH35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)
H35 Direct Vent Gas Stove Model H35-NG10 H35-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.94 kpa) 11 W.C. (2.74
More informationGOLD GV. Venting Supplement. Water boiler Series 3. Special gas vent system vent and combustion air supplement. Hazard definitions.
GOLD GV Water boiler Series 3 Venting Supplement Special gas vent system vent and combustion air supplement ProTech Systems AL29-4C Stainless Steel Special Gas Vent System may be used in new installations
More informationINSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT
C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS
More informationPelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)
Installation Instructions PelletVent Pro (PVP) PelletVent Factory-Built Chimney Relining A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS.
More informationSide by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Side by side 6720804520-20.1V Extension Set for units 3 or 4-7 736 501 254 6 720 811 761 / 238-50976-00A (2014/05) Table of contents Table
More informationFasNSeal. Installation Instructions
Installation Instructions FasNSeal & FasNSeal W2 Single-wall and Double-wall special gas vent FasNSeal Flex Flexible chimney liner for special gas vent for Category II, III, and IV appliances FasNSeal
More informationP P Gas Fireplace. P See Thru
P121-10 - P131-10 Gas Fireplace Model P121/P131-NG10 P121/P131-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa)
More informationGas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10
Back wall Gas Stoves Model C34-NG10 C34-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C. (2.74 kpa)
More informationBack to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions
Installation instructions Cascade Venting System for RTG 199HE Back to back Basic Set for units 1 and 2-7 736 501 253 6 720 811 762 / 238-50973-00A (2014/05) Table of contents Table of contents 1 Key to
More informationCorr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.
CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-1995 Listing No. MH26687 Testing No. 11EN
More informationNovaVent. Dimensional Data
NovaVent Dimensional Data NovaVent The new vent system designed and engineered for today s competitive sales environment. NovaVent NovaVent is designed and engineered to meet the requirements of gas-fired
More informationReplacement parts. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS REPLACEMENT PART NUMBERS. REINSTALL Jacket door
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A ECO MAINTENANCE KIT AVAILABLE The ECO maintenance kit includes components that may have to be replaced when accessing or disassembling parts of the
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FACTORY BUILT CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationTrinity Tft Model Numbers: Tft Version Date:
Trinity Tft Model Numbers: Tft60-399 Version Date: 2011-10-17 NEW PRODUCT LINE High Efficiency Firetube Condensing Gas Boiler INSTALLATION AND OPERATION INSTRUCTIONS FOR TRINITY Tft BOILER TABLE OF CONTENTS
More informationAqua Balance. Direct Exhaust Venting Kit Instructions
Aqua Balance WMB-155H and WMB-155C Wall Mount Gas-Fired Heating Only Boiler & Combination Boiler Heating and Domestic Hot Water Direct Exhaust Venting Kit Instructions AquaBalance TM WMB-155H & WMB-155C
More informationVenting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions
GOLD GV Water Boiler Series 3 & 4 Venting Supplement 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Heat-Fab, Inc. AL29-4C Stainless Steel Special Gas Vent
More informationGas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems
H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.
More informationTW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40
TW-Pro Twin Wall Insulated Flue System EN1856-1 T600 N1 W V2 L50040 G50 / O40 Approvals TW-Pro Twin Wall Insulated Flue System - TW-Pro has been specifically designed with the installer in mind with a
More informationVenting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness
Venting Vent Material This unit is approved for installation using 4 x 6-5/8 in co-axial direct vent pipe and accessories manufactured by Simpson Dura-Vent. Follow the installation instructions supplied
More informationVmax Boiler Model Number: VM110, VM110P Version Date:
Vmax Boiler Model Number: VM110, VM110P Version Date: 2015-02-09 NEW PRODUCT Fire-tube Boiler w/ Built-in Pump INSTALLATION AND OPERATION INSTRUCTIONS FOR Vmax BOILER TABLE OF CONTENTS 1.0 INTRODUCTION...
More informationVmax Boiler Model Number: VM110, VM110P, VM153 & VM153P Version Date: INSTALLATION AND OPERATION MANUAL
Vmax Boiler Model Number: VM110, VM110P, VM153 & VM153P Version Date: 2018-12-12 INSTALLATION AND OPERATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 SPECIFICATIONS... 6 3.0 BOILER LOCATION...
More informationMODEL CF CEILING SUPPORTED CHIMNEY
Manufactured by Selkirk Canada Corp. - Hamilton, Ontario Installation Instructions for MODEL CF CEILING SUPPORTED CHIMNEY Round Top Storm Collar Flashing Attic Insulation Shield/Firestop Spacer Intermediate
More informationType B Gas Vent. Installation Instructions
Installation Instructions Round and Oval Type B GasVent Systems for use with natural as or liquid propane category I and draft hood equipped appliances and appliances listed to use Type B Gas Vent. Type
More informationPVC, CPVC, PP & SS Vent Supplement
PVC, CPVC, PP & SS Vent Supplement CHALLENGER SOLO: CC50s, CC85s, CC105s, CC125s, CC125Hs, CC150s COMBI: CC105, CC125, CC125C, CC125H This document is intended to be used by a qualified heating contractor
More informationCHIMNEY INSTALLATION. Technical Bulletin #1
Technical Bulletin #1 CHIMNEY INSTALLATION A chimney performs two functions: it removes smoke and flue gases from the stove/furnace, and it provides draft for the fire. Draft is the term used to describe
More informationPellet Stove. Flex Pipe. Appliance Connector
Installation Instructions & Owners Maintenance Guide DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances Introduction Direct-Temp for Multi-Fuel
More informationPVC, CPVC, PP & SS Vent Supplement
PVC, CPVC, PP & SS Vent Supplement This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the CHAL- LENGER Installation
More informationInstallation and Maintenance Instructions
Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas
More informationInstallation Instructions for use by heating contractor
Installation Instructions for use by heating contractor Vitocrossal 300 CU3A Models 26, 35, 45, 57, 94, 125, 160, 199 Rigid and Flex Pipe Venting Systems Product may not be exactly as shown Read and save
More informationVenting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4
GOLD GV Water Boiler Series 3 & 4 Venting Supplement Direct Vent Through-Roof or Through-Unused-Chimney For use with Weil-McLain Through-Roof or Through- Unused-Chimney Termination Kit Kit part # 382-200-435
More informationCHIMNEYS AND VENTS CHAPTER 8
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationCHAPTER 8 CHIMNEYS AND VENTS
CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.
More informationInstallation Instructions for use by heating contractor
Installation Instructions for use by heating contractor Vitocrossal 300 CU3A Rigid and Flex Pipe Venting Systems Product may not be exactly as shown Read and save these instructions for future reference.
More informationPVC Venting Addendum. RIVA Plus WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY
PVC Venting Addendum RIVA Plus WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY Biasi Riva Plus PVC venting accessories Part #: RI 10999.0912 Trade Price: $140.00 PVC venting adapter: This adapter is required
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions Saf-T Vent Model EZ Seal Single Wall AL 29-4C Stainless Steel Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada) For
More informationINSTALLATION OF VENTING SYSTEM COMPONENTS WARNING
INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service
More informationPVC, CPVC, PP & SS Vent Supplement
PVC, CPVC, PP & SS Vent Supplement L I S T E D This document is intended to be used by a qualified heating contractor or service technician. Read all instructions within this document and within the PRESTIGE
More informationTrinity Ti Model Numbers: Ti Version Date:
Trinity Ti Model Numbers: Ti100-200 Version Date: 2015-10-13 INSTALLATION AND OPERATION INSTRUCTIONS FOR TRINITY Ti BOILER TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 INTRODUCTION... 6 3.0 BOILER LOCATION...
More informationInstallation Instructions for use by heating contractor
Installation Instructions for use by heating contractor for Vitodens 100-W WB1B Series, Vitodens 200-W WB2B Series, Vitodens 200-W B2HA/B2HB Series and Vitodens 222-F B2TA/B2TB Series All boilers listed
More informationDirectVent Pro CVS. Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces.
DirectVent Pro Unitized, co-axial venting system for direct vent gas or propane stoves, and fireplaces. VS Venting System for ategory II, III, and IV gas appliances. Listed to UL-1738 and UL S636. Specifications
More informationHIGH EFFICIENCY FIRE TUBE CONDENSING GAS BOILER
US This manual must be left with owner and should be hung on or adjacent to the boiler for reference. HIGH EFFICIENCY FIRE TUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 INSTALLATION AND OPERATING
More informationFTV Boiler Model Numbers: FTV110, FTV110C, FTV150, FTV150C, FTV190 & FTV190C Version Date:
FTV Boiler Model Numbers: FTV190 & FTV190C Version Date: 2018-03-12 INSTALLATION AND OPERATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 SPECIFICATIONS... 6 3.0 BOILER LOCATION... 7 4.0 GENERAL
More informationInstallation Instructions for use by heating contractor. Vitodens Common Venting System IMPORTANT
Installation Instructions for use by heating contractor Common venting for Vitodens 200 B2HA 45 to 530 Vitodens 200 B2HB 45, 57, 160, 199 Vitodens Common Venting System Product may not be exactly as shown
More informationHIGH EFFICIENCY FIRE TUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399
C US This manual must be left with owner and should be hung on or adjacent to the boiler for reference. HIGH EFFICIENCY FIRE TUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 INSTALLATION AND OPERATING
More informationInstallation instructions Logamax plus. GB162-L.B. 80 kw GB162-L.B. 100 kw. Read carefully before carrying out installation and maintenance.
Condensing gas boiler CAUTION! Before putting the boiler into operation read this manual carefully. DANGER! Improper installation, adjustment, alteration, service or maintenance can cause injury, loss
More information200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual
M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for
More informationendless quality and support
endless quality and support 100 years of smart comfort The highest standards of quality For nearly a century, Rinnai has been fiercely committed to delivering a smarter kind of comfort. With headquarters
More informationVENT SYSTEM COMPONENTS
Chimney Liner Kits Chimney Liners - All Fuel Chimney Liners - Gas Made from durable, corrosion-resistant type 316 stainless steel Designed to be used with wood, oil, coal and non-condensing gas-fired appliances
More informationTHE NEXT GENERATION IN CONDENSING BOILERS
endless quality and support The highest standards of quality For nearly a century, Rinnai has been fiercely committed to delivering a smarter kind of comfort. With headquarters in Japan and a network of
More informationPower-Fin 4:1 HOT WATER HEATING BOILERS DOMESTIC HOT WATER SUPPLY BOILERS 1,500,000, 1,700,000 and 2,000,000 Btu/hr MODELS
PBE/PFE-i&s-03 INSTALLATION AND SERVICE MANUAL Power-Fin 4:1 HOT WATER HEATING BOILERS DOMESTIC HOT WATER SUPPLY BOILERS 1,500,000, 1,700,000 and 2,000,000 Btu/hr MODELS FIG. 1 Front View 1,500,000-2,000,000
More informationBring In the Fresh Air
ring In the Fresh Air ombustion Air System For DuraTech, DuraPlus HT and PelletVent Pro DuraVent s new, exclusive, patentpending DuraPro ombustion Air System Wall Thimble and eiling Support oxes is the
More information