***DRAFT - NOT FOR FILING***

Similar documents
Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Electrical Tech Note 107

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

TECHNICAL ARTICLE. Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009

Town of Cicero Local Code Amendments

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

MaxLite LED Round Pendant Highbay Series

REQUIREMENTS & GUIDELINES

Code verification sign-off

Dear Concessionaire,

Brighton Area Fire Authority

Chapter 1 General... 5

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

New Facilities. Minimum Requirements

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Code Compliance Report

School Fire Safety Checklist

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

Code Compliance Report

(h) Pesticide Application.

DONALD H. BERG, ARCHITECT

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

TOM BURNS, PLANNING DIRECTOR

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

LIGHTING CAUTION NEW LISMORE 9 ARM CHANDELIER W 110V

Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments.

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Photovoltaic (Solar) Array Installation Guide

Integrated Ventilation System

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

APPLICATION FOR Large Family Day Care Permit

The Owner will provide the QEI inspection and certification services.

New Construction Fire Inspection Process

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

C i t y o f G r o v e r B e a c h ADMINISTRATIVE SERVICES DEPARTMENT

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

2011 and 2014 National Electrical Code Changes Residential Only

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

Fire/General Safety Review Program Key Performance Indicators Environmental Health and Safety

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

Get it Right the First Time Avoid These Commonly Cited Errors

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

VENTING GAS APPLIANCES NFPA 54 CODE

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

REPORT ON DISCUSSIONS DURING UL MEETINGS WITH ELECTRICAL INSPECTORS AT THE 2003 IAEI 75 th JUBILEE MEETING

SECTION INSPECTION AND TESTING OF WORK

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION SPRINKLER SYSTEMS

Bold items are particular to the City of Euless

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Electrical Safety Program

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

DHL-LP-LED Low Profile LED Linear High/Low Bay

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Home Inspection Report

FIRE ALARM: BY OTHERS, IF REQUIRED.

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST

ll. Consistency Questions

FIRE ALARM: BY OTHERS, IF REQUIRED.

LIMITED LIFETIME WARRANTY

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

CEILING FAN OWNER'S MANUAL

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

Code Compliance Report

Habitability Guidelines

LIMITED LIFETIME WARRANTY

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Construction Codes Advisory Council

Electrical Licensing & Inspection at Asphalt Plants. Dean Hunter

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

SCC BULLETIN DPS/SCC Directive Date of issue: December 4, 2002

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Page 1 of General

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

N.J.A.C. 5: A. NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Apartment Fire & Safety Inspection. City of Guadalupe

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

I dedicate this book to the Lord Jesus Christ, my mentor and teacher. Proverbs 16:3 NOTICE TO THE READER ABOUT THE AUTHOR

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Spring Test 6 due 04/26/2013

Plan Submittal Checklist

I. STRUCTURAL SYSTEMS

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Transcription:

4781-6-03.7 Electrical systems and equipment. (A) Electrical crossovers. Multi-section homes with electrical wiring in more than one section require crossover connections to join all sections of the home. The crossover shall be completed in accordance with the directions provided in the installation instructions. (B) Miscellaneous lights and fixtures. (1) When the home is installed, exterior lighting fixtures, ceiling-suspended (paddle) fans, and chain-hung lighting fixtures shall be permitted to be installed in accordance with their listings, the MHCSS, and these standards. (2) Grounding. (a) All the exterior lighting fixtures and ceiling fans installed per the MHCSS and these standards shall be grounded by a fixture-grounding device or by a fixture-grounding wire. (b) For chain-hung lighting fixtures, as shown in figure 7A of this rule, both a fixture-grounding device and a fixture-grounding wire shall be used. The identified conductor shall be the neutral conductor.

(3) Where lighting fixtures are mounted on combustible surfaces such as hardboard, a limited combustible or noncombustible ring, as shown in figures 7A and 7B of this rule, shall be installed to completely cover

the combustible surface exposed between the fixture canopy and the wiring outlet box. (4) Exterior Lights. (a) The junction box covers shall be removed, and wire-to-wire connections shall be made using listed wire connectors. (b) Wires shall be connected in compliance with the national electricelectrical code (NEC) 2008.

(c) The wires shall be pushed into the box, and the lighting fixture shall be secured to the junction box. (d) The lighting fixture shall be caulked around its base to ensure a watertight seal to the sidewall. (e) The light bulb shall be installed, and the globe shall be attached. (5) Ceiling fans. (a) Ceiling-suspended (paddle) fans shall be connected to a junction box listed for ceiling fan application and installed with the trailing edges of the blades at least six feet four inches above the finished floor. (b) The wiring shall be connected in accordance with the product manufacturer's installation instructions. (6) Testing. (a) After completion of all electrical wiring and connections, including crossovers, electrical lights, and ceiling fans, the electrical system shall be inspected and tested. Testing shall be done in accordance with the manufacturer's installation instructions. Where no manufacturer's installation manual test procedure is available, the test shall be performed in accordance with testing procedures provided on forms approved by the commissiondivision. (b) Each manufactured home shall be subjected to the following tests: (C) Smoke alarms. (i) An electrical continuity test to ensure that metallic parts are effectively bonded; (ii) Operational tests of all devices and utilization equipment, except water heaters, electric ranges, electric furnaces, dishwashers, clothes washers/dryers, and portable appliances, to demonstrate that they are connected and in working order; and (iii) For electrical equipment installed or completed during installation, electrical polarity checks shall be completed to determine that connections have been made properly. Visual verification is an acceptable electrical polarity check. Smoke alarms shall be functionally tested in accordance with applicable requirements of the smoke alarm manufacturer's instructions and shall be consistent with this rule. Where no manufacturer's installation manual or alarm manufacturer's test procedure is available, the test shall be performed in accordance with testing procedures provided on forms approved by the commissiondivision. All homes shall be required to have operational smoke detectors per NFPA recommendations. (D) Telephone and cable television. Refer to rule 4781-6-02.94781-6-03.9 of the Administrative Code for considerations pertinent to installation of telephone and cable television. (E) Except where otherwise specified in these standards, electrical supply, electrical systems, and equipment installed on site for manufactured homes in a manufactured home park and a single site (private property)

shall comply with the national electric code (NEC) 2008, Article 550. (F) On-site wiring methods not included in the manufacturer's installation instructions shall comply with the requirements of the national electric code (NEC) 2008NEC and shall be inspected by a state- certified electrical safety inspector (ESI) of record certified by the board of building standards or a licensed electrical contractor whose name is on the license issued under Chapter 4740. of the Revised Code. (G) Electrical service, connectors, and feeders shall be inspected by a state certified electrical safety inspector (ESI)an ESI of record certified by the board of building standards whose name is on the license issued under Chapter 3783. of the Revised Code.