Technical Data Submittal Documents

Similar documents
Technical Data Submittal Documents

Technical Data Submittal Document

Model GPD Diesel Engine Driven Fire Pump Controller

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Drawing Submittal Package

Drawing Submittal Package

Options for Diesel Fire Pump Controllers

Model GPP Full Service Reduced Voltage Part Winding Electric Fire Pump Controller

Model GPS Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller

Model GPA Full Service Full Voltage Across the Line Start Electric Fire Pump Controller

Model GPW Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPW + GPU Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPY + GPU Full Service Reduced Voltage Wye-delta Open Electric Fire Pump Controller with Automatic Power Transfer Switch

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

FDF Foam Pump Controllers Features

Fire Pump Controllers Foam (Additive) Controllers

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features

FD30 Full Voltage - Across the Line July 2011

Technical Data Submittal Document

Technical Data Submittal Document

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

LMR Electric Fire Pump Controllers Features

LMR Electric Fire Pump Controllers Features

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Fire Pump Controllers Medium Voltage Controllers

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

Variable Frequency Drive SERIES MP800 VFD

Digital Control Systems & Remote Communications Options

FT20 Full Voltage - Limited Service. Electrically and Mechanically

DGC-500 DIGITAL GENSET CONTROLLER

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

FT60 Reduced Voltage - Autotransformer

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

NS (A) ECN

MASTER DIESEL FIRE PUMP CONTROLLER

FTA550 JOCKEY PUMP CONTROLLERS

MASTER DIESEL FIRE PUMP CONTROLLER

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

AS950 REFRIGERATED SAMPLERS

Remote Alarm Panels Features

RAYCHEM NGC-30 COMPONENTS

DGC-1000 DIGITAL GENSET CONTROLLER

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Transfer Switch Features

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

FDJ SERIES Jockey Pump Controllers Features

Commercial and Light Industrial Fire Alarm Control Panel

Transfer Switch Features

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 Advanced Heat-Tracing Control System

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

AS950 PORTABLE SAMPLERS

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Specification/ Data Sheet

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

21-light Remote Annunciator. Owner s Manual

Two-Channel Gas Controller

M2500 Engine Controller Installation Manual

PART GENERAL 1.01 SECTION INCLUDES

Gas Controller Module GC-06

Synova TM product catalog.

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Temperature Controllers

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Pump-Down Controller MODEL 4052

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

PolyGard 2-channel Gas Controller MGC-03

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

PowerWizard Range. Digital Control Systems & Remote Communication Options.

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Touchpoint Plus. A whole new control experience

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

TraceNet ECM Series Control System

Transcription:

Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Documents Model PD Diesel Engine Driven Fire Pump Controller Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note: The drawings included in this package are for controllers covered under our standard offering. Actual AS BUILT drawings may differ from what is shown in this package. August 2016

PD Diesel Fire Pump Controller Standard, Listings, Approvals and Certifications Enclosure Ambient Temperature Rating eneral Electrical Reading Pressure Reading Pressure and Event Recorder Built to NFPA 20 (latest edition) Underwriters Laboratory (UL) FM lobal Class 1321/1323 New York City Seismic Certification Optional CE Mark Protection Rating Standard: NEMA 2 (IP31) Optional NEMA NEMA 3 NEMA 3R NEMA 4 Accessories Bottom entry gland plate Lifting Lugs Keylock handle Standard 5 C to 40 C / 41 F to 104 F Optional 5 C to 55 C / 41 F to 131 F AC DC rounding system Battery chargers UL218 - Fire Pump Controllers CSA C.2 No. Industrial Control Equipment Accepted for use in the City of New York by the Department of Buildings See page 5 for details Various EN, IEC & CEE directives and standards NEMA 4X-304 sst painted NEMA 4X-304 sst brushed finish NEMA 4X-316 sst painted NEMA 4X-316 sst brushed finish 0V / 1ph / 60hz 208V to 0V / 1ph / 50-60hz VDC VDC Negative Battery 1 & Battery 2 voltage Battery 1 & Battery 2 charging amperage Charging mode Continuous system pressure display Cut-in and Cut-out pressure setting Two independent fully automatic 10A continuous charge 500mA trickle charge Paint Specifications Red RAL3002 Powder coating lossy textured finish Pressure readings with date stamp Event recording with date stamp Under regular maintained operation, events can be stored in memory for up to 5 years Data viewable on operator interface display screen Downloadable by USB port to external memory device IP54 IP55 IP65 IP66 August 2016 2

PD Diesel Fire Pump Controller Pressure sensing Audible Alarm Visual & Audible Alarms Remote Alarm Contacts Terminals for Field Connections for External Devices ViZiTouch Operator Interface Pressure transducer and run test solenoid valve assembly for fresh water application Pressure sensing connection 1/2 Female NPT Drain connection 3/8 Rated and calibrated for 0-500psi working pressure Externally mounted with protective cover 4 alarm bell - 85 db at 10ft. (3m) Visual only Engine run Main switch AUTO ECM warning Pump room temperature ( o F or o C) Visual and Audible Overspeed Low oil pressure High engine temperature Fail to start High fuel level ECM fault ECM Selector switch in alternate position DPDT-8A-250V.AC Engine run Common controller trouble Charger #1 & Charger #2 failure Pressure line failure Common engine trouble High engine temperature Battery #1 & battery #2 failure Fail to start DC failure Fuel injection malfunction** Loss of continuity (starter) #1 and/or #2 ECM selector switch in alternate position*** Common pump room alarm (field re-assignable)* Low fuel level Low suction pressure High fuel level Low pump room temperature Fuel tank leak High pump room temperature H-O-A selector switch in OFF or HAND Free (field programmable)* Low fuel level High fuel level (re-assignable) Fuel tank leak (re-assignable) Remote AUTOMATIC start Deluge valve start (re-assignable) Solid state controls 4.2 color touch screen (HMI technology) Upgradable software Expandable storage Multi-language Periodic test Main switch in HAND High raw water temperature Battery #1 & battery #2 failure Charger #1 & Charger #2 failure AC power available Low pump room temperature System overpressure PLD low suction pressure Cranking Cycle Main switch in OFF Low raw water flow Low fuel level Water reservoir low Fuel tank leak Fail when running Fuel injection malfunction Low engine temperature Overspeed Fail when running Low oil pressure Water reservoir low Water reservoir empty AC Failure *Except if option C13 is ordered. Tornatech reserves the right to use any of these four alarm points for special specific application requirements **Applicable to electronic engines only. *** Applicable to electronic engines only. Alarms when ECM selector switch on the engine is in alternate mode. August 2016 3

PD Diesel Fire Pump Controller Operation Selector Switch Automatic Start Manual Start Crank Cycle Stopping Timers Actuation Mode Hand-Off-Auto Behind lockable and breakable cover Start on pressure drop Remote start signal from automatic device Crank 1 and Crank 2 start pushbuttons Run test pushbutton Deluge valve start Remote start from manual device 6 consecutive cycle attempts 3 X 15s crank from battery 1 or 2 alternatively 15s rest in between each crank attempt Manual with Stop pushbutton Automatic after expiration of minimum run timer *** Field Adjustable & Visual Countdown Visual Indication Minimum run timer ***(off delay) Sequential start timer (on delay) Periodic test timer Pressure Non-pressure Automatic Non-automatic Communication Protocol Capability Protocol: Modbus Connection type: Shielded female connector RJ45 Frame Format: TCP/IP Addresses: See bulletin MOD-PD Alarm and shutdown schedule Automatic Start Manual or Remote Start Run Test or Periodic Test High Coolant Alarm only Alarm only Shutdown Low Oil Pressure Alarm only Alarm only Shutdown Overspeed Shutdown Shutdown Shutdown Starting Voltage Approx. shipping dimensions in inches (mm) Wall Mount Approx. Shipping Weight in Lbs (kg) Approx. shipping dimensions in inches (mm) Floor Mount Approx. Shipping Weight in Lbs (kg) V.DC V.DC 32" l x 29" w x 16" h (813 x 737 x 407 ) 85 (39) 32 l x 29 w x 26 h (813 x 737 x 661) 5 (52) *** Automatic shutdown shall be approved by the AHJ. August 2016 4

PD Diesel Fire Pump Controller Seismic Certification Seismic Certification Company Mounting details Seismic Information TRU Compliance, LLC A Tobalski Watkins Affiliate TWEI Project No.: 150 Rigid wall mounting Building Code IBC 2015, CBC 2016 Test Criteria ICC- ES AC156 Seismic Parameters SDS z/h I P A FLX-H A RI-H A FLX-V A RI-V ASCE 7-10 Chapter 13 2.0 1.0 1.5 3.20 2.40 1.33 0.53 3.2 0.0 1.5 3.20 1.28 2.13 0.85 10.0 RRS for Nonstructural Components Testing Spectral Response Acceleration (g) 1.0 0.1 0.1 1.0 10.0 Frequency, f (Hz) Horiz. Level 1 Vert. Level 1 Notes: Components are tested in accordance with ICC-ES AC156, IBC 2015 & CBC 2016. OSHPD Special Seismic Certification Preapproval (OSP) August 2016 5

PD Diesel Fire Pump Controller A1 A2 A3 A4 A5 A6 A7 A8 A9 A A Ax B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B B B13 Bx C5 C6 C7 C8 C9 C13 Periodic test alarm contact (Form C-SPDT) Overspeed alarm contact (Form C-SPDT) Low oil pressure alarm contact (Form C-SPDT) High coolant temperature alarm contact (Form C-SPDT) Failure to start alarm contacts alarm contact (Form C-SPDT) Battery 1 & 2 failure alarm contact (2 x Form C-SPDT) Charger 1 & 2 failure alarm contact (2 x Form C-SPDT) AC failure alarm contact (Form C-SPDT) System overpressure alarm contact (For engines with PLD) (Form C-SPDT) Extra controller trouble alarm contact (Form C-SPDT) Extra engine trouble alarm contact (Form C-SPDT) Additional engine alarm contact (Form C-SPDT) (specify function) Low fuel level alarm contact (Form C-SPDT) Water reservoir level low alarm contact (Form C-SPDT) Water reservoir empty alarm contact (Form C-SPDT) Low pump room temperature alarm contact (Form C-SPDT) High fuel level alarm contact (Form C-SPDT) Low system (discharge) pressure alarm contact (Form C-SPDT) Low suction pressure alarm contact (Form C-SPDT) Pump on demand alarm contact (Form C-SPDT) Fuel tank leak alarm contact (Form C-SPDT) Main relief valve open alarm contact (Form C-SPDT) Flow meter loop valve open alarm contact (Form C-SPDT) Water reservoir level high alarm contact (Form C-SPDT) High pump room temperature alarm contact (Form C-SPDT) Additional pump room alarm contact (Form C-SPDT) (specify function) CE Mark with factory certificate Nickel Cadmium battery chargers Engine block heater circuit (same voltage as battery charger primary) Foam pump application w/o pressure transducer and run test solenoid valve Non pressure actuated controller w/o pressure transducer and run test solenoid valve Louver activation circuit (battery power specific) C C15 C16 C17 C19 D4 D6 Delayed automatic start on AC power failure (factory set at 15 minutes) Low zone pump control function Middle zone pump control function High zone pump control function Lockout/interlock circuit from equipment installed inside the pump room Pressure transducer and run test solenoid valve for fresh water rated for 0-500psi (for factory calibration purposes only) Pressure transducer and run test solenoid valve for sea water rated for 0-500PSI D7A Low fuel level float switch supplied as separate item (1-1/4 ) D7B Low fuel level float switch supplied as separate item (1-1/2 ) D8A High fuel level float switch supplied as separate item (1-1/4 ) D8B High fuel level float switch supplied as separate item (1-1/2 ) D9A D9B D9C D DA D D25 D25A D25B D25C D25D Anti-condensation heater & thermostat Anti-condensation heater & humidistat Anti-condensation heater & thermostat & humidistat Low suction pressure transducer for fresh water rated at 0-300PSI with visual indication and alarm contact Low suction pressure transducer for sea water rated at 0-300PSI with visual indication and alarm contact Tropicalization Mounting stand Mounting stand SST- 304 painted Mounting stand SST- 304 brushed finish Mounting stand SST- 316 painted Mounting stand SST- 316 brushed finish D26 Combined low and high fuel level float switch (1-1/4 ) D26A Combined low and high fuel level float switch (1-1/2 ) D27 D28 D29 D30 D31 D32 D33 Fuel level probe (2 ) Level indication Field programmable I/O board - 8 Input / 5 output Field programmable I/O board - 8 Input / 10 output Redundant pressure transducer for fresh water rated for 0-500PSI Redundant pressure transducer for sea water rated for 0-500PSI Modbus with RTU frame format and RS485 connection Window kit for operator interface Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. August 2016 6

PD Diesel Fire Pump Controller L01 Other language and English (bilingual) L Russian L02 French L15 Turkish L03 Spanish L16 Swedish L04 erman L17 Bulgarian L05 Italian L18 Thai L06 Polish L19 Indonesian L07 L08 L09 L10 L L Romanian Hungarian Slovak Croatian Czech Portuguese L20 L21 L L23 L L25 Slovenian Danish reek Arabic Hebrew Chinese L13 Dutch Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. August 2016 7

PD Diesel Fire Pump Controller ViZiTouch Operator Interface 1 3 2 4 5 6 7 8 9 10 1 2 13? 1 - Power on LED 2 - Color touch screen 3 - Alarm LED 4 - HOME page button 5 - ALARM page button 6 - CONFIURATION page button 7 - HISTORY page button 8 - USB port 9 - CRANK 1 button 10 - CRANK 2 button - Contextual navigation pad - STOP button 13 - RUN TEST button - HELP button August 2016 8

Diesel Engine Fire Pump Controller Vdc or Vdc Negative round Dimensions 27 1/8" [689] 26 1/8" [663] 23 3/4" [600] 1/4" [564] Model:PD Built to the latest edition of the NFPA 20 standard Ø3/8" [Ø10] X4 10" [253] 9" [8] See Notes 28 7/8" [734] 27 5/8" [700] 29 7/8" [760] 23 1/2" [597] 2 7/8" [73] 6 7/8" [174] 19 1/8" [486] 7/8" [327] - Controller Standard without Mounting Stand - Order Option D25 if Mounting Stand Required 47 7/8" [08] Sensing Line Connection - 1/2 " F.NPT Drain - 3/8 " M.TUBE 1/2" [571] 13 1/2" [343] 6 5/8" [168] 5" [7] 7 1/8" [183] Notes: Drawing for information only. Manufacturer reserves the right to modify this drawing without notice. Contact manufacturer for "As Built" drawing. 1 1/4" [31] - Standard NEMA: NEMA 2 - Standard Paint : Textured Red RAL 3002. - All Dimensions are in Inches [Millimeters]. - Center of ViZiTouch Screen: -1/4" [565] from Bottom (No Feet). - Bottom Conduit Entrance Through Removable land Plate Recommended. - Use Watertight Conduit and Connector Only. - Protect Equipment Against Drilling Chips. - Door Swing Equal to Door Width. - Seismic mounting to be rigid wall only. NYC Dpt of Building Approved REV. DESCRIPTION DD/MM/YY 1 Change Solenoid Valve Cover 20// 2 Added Seismic Logo 21/08/15 3 Modified Tornatech & Seismic Logo /04/16 Projection Drawing number PD-DI500 /E CDL Copyright 2016 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.

Diesel Engine Fire Pump Controller Vdc or Vdc Negative round Layout Model:PD Built to the latest edition of the NFPA 20 standard Designation F CB1-2 BC1-BC2 CB3-4 PDB SS1 MB IS1 Description Filter Magnetic Breaker 1 Pole 10 Amp. Battery Charger #1 and #2 Magnetic Breaker 1 Pole 15 Amp. I/O Diesel Board Lockable 3 Position Selector Switch ViZiTouch Main Board Isolating Switch BC1 MB BC2 DANER CB3 CB4 CB1 CB2 F SS1 RATIN LABEL PDB IS1 Front Door Layout Internal Layout REV. DESCRIPTION DD/MM/YY Drawing number 2 Change CB position 09/04/15 NYC Dpt of Building Approved 3 eneral Revision 26/06/15 PD-LY600 /E 4 Added Seismic logo 21/08/15 5 Modified Tornatech & Seismic logo /04/16 Copyright 2016 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.

Diesel Engine Fire Pump Controller Vdc or Vdc Negative round Wiring schematic L 0-0 Vac 50-60Hz N IS1 1L 1N F 53 L' L N E Filter 54 N' CB2 CB1 13 53 54 Power Available Model:PD Built to the latest edition of the NFPA 20 standard Battery Charger 1 Battery Charger 2 BATT. BOOST ALARM SUPPLY BATT. BOOST ALARM SUPPLY B1 B2 Com NO NC L N B1 B2 Com NO NC L N 63 15 16 17 18 13 54 83 19 20 21 54 Controller Trouble (Fail Safe) J36 TB1 I/O Diesel Board Engine Run Main Switch in HAND or OFF Common Engine Trouble Common Pump Room Alarm (Field Programmable) J38 TB2 J40 TB3 J42 TB4 J37 TB5 J39 TB6 J J16 J J15 J17 SV1 N AI5-IN AI4-IN AI3-IN AI2-IN Yellow/reen Blue Brown Analog Input Flow / Spare Temperature Analog Input Fuel Level Analog Input Water Level / Suction Pressure nd - SV1 Low Fuel Level 21 J18 AI1-IN Red White Black PT1 Discharge Pressure Transducer Remote Auto Start *J1 * Remove Jumper J1 to Use this Feature Deluge Valve Start ** Remove Jumper J2 to Use this Feature Fuel Tank Leak High Fuel Level **J2 23 25 26 27 28 29 30 MP MP- J25 J35 J44 Vac Vac J8 P1 53 54 Power Available P1 P2 ViZiTouch Main Board J J6 J3 Temperature Sensor 1 TM1 J16 () (-) Red Black - AB1 ECM SS in Alt. Pos Fuel Injection Malfunction Electronic Control Module Warning Electronic Control Module Fault PLD Low Suction Pressure High Raw Water Temperature Low Raw Water Flow Low Engine Temperature Energize to Start Solenoid Engine Run Overspeed Low Oil Pressure High Engine Temperature Battery 1 Battery 2 Start Contactor 1 Start Contactor 2 round round Energize to Stop Solenoid 301 302 303 304 305 310 3 3 1 2 3 4 5 6 8 9 10 301 302 303 304 305 310 3 3 1 2 3 4 5 6 8 9 10 J103 J104-1 J104-2 J104-3 J104-4 J104-5 J104-6 J104-7 J104-8 J104-9 J104-10 J104- J104- J1 NYC Dpt of Building Approved J4 J106 J107 J19-2 J19-1 J46-2 J46-1 J2-2 J2-1 J3-2 J3-1 J45-2 J45-1 Vext HV B1 B2- B1- CF1 B2 CF2 64 84 62 6 63 83 82 8 62 6 63 83 82 8 15 16 17 18 19 20 21 CB3 CB4 DI7 DI6 DI5 SS1 OFF H A Main Switch REV. DESCRIPTION DD/MM/YY 1 Added Re-Assignable Inputs 08/04/15 2 Added Seismic Logo and IS1 21/08/15 3 Modified Tornatech & Seismic Logo /04/16 DI4 Battery Charger 1 Battery Charger 2 J DI3 DI2 DI1 DI0 30 J13 ND AUTO 31 HAND V 32 Drawing for information only. Manufacturer reserves the right to modify this drawing without notice. Contact manufacturer for "As Built" drawing. Drawing number PD-WS602 /E CDL Copyright 2016 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.

Diesel Engine Fire Pump Controller Vdc or Vdc Negative round Louver Connections Model:PD Built to the latest edition of the NFPA 20 standard Located in Controller Engine Run Alarm Contact - - or or 21-21- 21 J38 TB2 M Louvers Motor Power Supply from a Reliable External Power Source (See NFPA20-2013.3.2 & A.3.2) NYC Dpt of Building Approved REV. DESCRIPTION DD/MM/YY 0 First Issue 25/05/15 1 Added Seismic logo 21/08/15 2 Modifed Tornatech & Seismic logo /04/16 Drawing number PD-TD403 /E Copyright 2016 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.

Diesel Engine Fire Pump Controller Vdc or Vdc Negative round Terminals Diagram 0-0 Vac 50-60Hz Power Supply Terminals Wire Size: 16-6 AW 2 Nm L IS1 N Engine Connections Model:PD Built to the latest edition of the NFPA 20 standard Controller Trouble (Fail Safe) Alarm Contacts Terminals Wire Size: - AW 0.5 Nm (--) / 8A (21-32-) / 5A I/O Diesel Board J36 - J36 - J36 - J36 - J36-21 J36 - TB1 Engine Terminal Strip Energize to Start Solenoid 1 Engine Run 2 Overspeed 3 Low Oil Pressure 4 High Engine Temperature 5 Battery 1 6 Battery 2 8 Start Contactor 1 9 Start Contactor 2 10 round round Energize to Stop Solenoid Electronic Control Module Selector Switch in Alternate Position 301 Fuel Injection Malfunction 302 Electronic Control Module Warning 303 Electronic Control Module Fault 304 PLD Low Suction Pressure 305 High Raw Water Temperature 310 Low Raw Water Flow 3 I/O Diesel Board 1 J104-1 2 J104-2 3 J104-3 4 J104-4 5 J104-5 6 J104-6 8 J104-7 9 J104-8 10 J104-9 J104-10 J104- J104- I/O Diesel Board 301 302 303 304 J103 305 310 3 Louver Activation Circuit Engine Run Main Switch in HAND or OFF Common Engine Trouble Common Pump Room Trouble (Field Programmable) Opens to activate Closes to activate J38 - J38 - J38 - TB2 J38 - J38-21 J38 - J40 - J40 - J40 - TB3 J40 - J40-21 J40 - J42 - J42 - J42 - TB4 J42 - J42-21 J42 - J37 - J37 - J37 - TB5 J37 - J37-21 J37 - J39 - J39 - J39 - TB6 J39 - J39-21 J39 - Low Engine Temperature 3 3 Low Fuel Level Remote Auto Start *J1 * Remove Jumper J1 to Use this Feature Deluge Valve Start ** Remove Jumper J2 to Use this Feature Fuel Tank Leak High Fuel Level Field Connections Terminals Wire Size: - AW 0.5 Nm **J2 I/O Diesel Board 21 23 25 26 27 28 29 30 J25 All wiring between the controller and diesel engine shall be stranded (NFPA20) Wiring between controller and engine (terminals 301, 302, 303, 304, 305, 310, 3, 3, 2,3,4,5) must be #AW as minimum. Wiring between controller and engine (terminals 1, [rated at 8A or 10A for 20 seconds] 9, 10 [rated at 8A or 10A for 15 seconds]) must be stranded #10AW as minimum. Wiring between controller and engine (terminals 6, 8, [rated at A]) must be stranded and sized according to distance. NYC Dpt of Building Approved REV. DESCRIPTION DD/MM/YY 2 Added Seismic logo 21/08/15 3 Louver activation circuit added 08//15 4 Modifed Tornatech & Seismic logo /04/16 Drawing number PD-TD602 /E Copyright 2016 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.