FEATURS HYUNDAI CLIMATE CONTROL CO., LTD.

Similar documents
LECTURE-18 Vapour Absorption Refrigeration System

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM

MODELS YIA 1A1 THROUGH YIA 14F3

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Specifications in the catalogue are subject to change without notice. AR-1012 Printed in Korea

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

Technical Data Sheet

Absorption Chiller Heat Pump

Start-Up, Operation, and Maintenance Instructions

ABSORPTION REFRIGERATION SYSTEMS

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

DOUBLE EFFECT ABSORPTION CHILLER /HEATER MG MODEL 1

Start-Up, Operation, and Maintenance Instructions

Water-Fired Chiller/Chiller-Heater. WFC-S Series: 5, 10, 20, 30 and 50 RT Cooling

CUSTOMIZED ABSORPTION HEAT PUMPS FROM INDIAN INDUSTRY

Gas-Fired Double-Effect Chiller-Heater

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

7 THERMAL APPLICATIONS

Adsorption Chillers Energysmart Green Cooling

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw

Appendix 13. Categories of Cooling and Heating systems

HVAC Equipments and Systems

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Page 1 of Relevant Provincial Jurisdictional legislation.

16LJ Single-Effect Hot Water-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

Product Data. Features/Benefits. 16JT Double-Effect Hermetic. Absorption Liquid Chillers Provide. With Product Integrated Controls (PIC)

There are several heat transfer loops in refrigeration system as described below: Figure 4.1 Heat Transfer Loops In Refrigeration System

HVAC Equipment and Systems

16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

Chapter 11 REFRIGERATION CYCLES

Technical Catalog SAB-LW Series Single Effect Double Lift Hot Water Driven Absorption Chiller 65 to 1,300 Nominal Tons (229 to 4,571 kw)

16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

Air-Cooling Evaporators

INSERT NEW PHOTO HERE

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

MaintenanceCircleTeam Page 1 June 7 th 2009 Maintenanc Maintenance circle

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

UNIT 4: REFRIGERATION PRINCIPLE

Chapter 11 REFRIGERATION CYCLES

Thermachill Absorption Chillers

Refrigeration Systems and Accessories

Product Data. Features/Benefits. 16JB Steam/Hot Water Single Effect, Hermetic Absorption Liquid Chiller 50/60 Hz

Engineered for flexibility and performance

Refrigeration and. Modern. Air Conditioning. Bracciano, BS, M.Ed., Ed. Sp. Alfred F. Andrew D. Althouse, BS, (ME), MA. Carl H. Tumquist, BS, (ME), MA

Refrigerant Installation Quick Reference Guide

Chilled Water system

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

FORM EG1 (1008) YIA Single-Effect Absorption Chillers Steam And Hot Water Chillers Style A TONS ( kw)

Fundamentals of Refrigeration p. 25 History and Fundamentals of Refrigeration Module p. 25 Development of Refrigeration p. 25 How a Mechanical

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 7, Issue 11, May 2018

Product Data. Features/Benefits. 16TJ Single-Effect, Steam Hermetic Absorption Liquid Chiller. 100 to 700 Nominal Tons

HVAC Fundamentals & Refrigeration Cycle

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

100 RT CH-K SERIES GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Refrigeration Technology in Building Services Engineering

MODELS LIST. Nominal Capacity RT

MECHANICAL SCIENCE Module 2 Heat Exchangers

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Thermodynamics II Chapter 5 Refrigeration

Model YPC Two-Stage Steam-Fired Absorption Chiller Style C

Brazed plate heat exchangers. For the refrigeration industry

R-407A R-448A R-449A

Chapter 10. Refrigeration and Heat Pump Systems

ABSORPTION CHILLER PRODUCT CATALOGUE

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

GAS-FIRED DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

Appendix A. Glossary of Common Terms

Air Conditioning and process cooling Energy Components at a Glance

Guide Specifications

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

30 80 RT K-SERIES GAS-FIRED, DOUBLE-EFFECT ABSORPTION CHILLER-HEATER

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Solution of I Mid Term Steam Engineering 6ME5A

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Case Study Condenser expertise from SPX focuses maintenance where it s needed and cuts downtime to a minimum to restore production to full capacity

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Refrigeration System with a Capillary Tube and a Thermostat

MILLENNIUM YPC Two-Stage Steam-Fired Absorption Chiller Models YPC-ST-14SC through YPC-ST-19S 300 through 675 Tons 1050 through 2373 kw

Method to test HVAC equipment at part load conditions

Design and Fabrication of Water Refrigeration System by Creating Vacuum

JEFFERSON COLLEGE COURSE SYLLABUS HRA 249 COMMERCIAL REFRIGERATION SYSTEMS. 5 Credit Hours. Prepared by: William Kaune November 30, 2010

products 22 º C Ventilation Air Conditioning Refrigeration Maritime Absorption Chiller Inside PROVIDED BY HEINEN & HOPMAN

Technical Catalog. SAB-HW Series Hot Water Driven Absorption Chiller 15 to 1000 Nominal Tons (52 to 3516 kw) ISO 9001 ISO CHP Solution Inc.

4th IIR International Conference on Thermophysical Properties and Transfer Processes of Refrigerants 2013

Operation/ Maintenance. Horizon

SAFETY AND ENVIRONMENTAL EDUCATION FOR DEVELOPMENT SEED

Revised April High School Graduation Years 2016, 2017, and Unit/Standard Number

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

Transcription:

FEATURS 1. Direct-fired absorption chiller-heater gives both heating and cooling. 2. The high efficiency associated with the absorption chilling system has reduced the space required for installation. 3. Absorption chiller gives lower running costs than eletrical chiller. 4. Ozone safe, cfc free, cooling requirements are met without chlorine based refrigerants. 5. Low noise and vibration. Hyundai absorption chilling system does not utilize a large motor-compressor, and this leads to quiet, trouble free operation. 6. Three different leak tests are performed in the shop to minimize leaks and to ensure high quality and reliability. 7. Hyundai absorption chilling system provides fully automatic control system such as stabilizer control, override control and de-crystalization system for simple, trouble-free operation. 8. Excellent for peak shaving during high electrical demand periods.

T HOW IT OPERATES he principle of refrigeration is the exchange of heat, and in direct-fired absorption chiller-heaters, there are five basic heat exchangers; evaporator, absorber, high and low pressure generators and condenser. In absorption chiller-heaters, the refrigerant is water. But like any other refrigeration system, the absorption chiller uses evaporation and condensation to remove heat. To maintain effective evaporation and condensation, the two-stage absorption chiller-heater employs two shells or one shell partitioned into two zones. The lower shell or zone (Evaporator and Absorber) has an internal pressure of about one-hundredth that of the outside atmosphere, or 6mm Hg, a relatively high vacuum. The vacuum allows water (the refrigerant) to boil at a temperature below that of the liquid being chilled. Thus chilled liquid entering the evaporator can be cooled for air conditioning purposes. 1. EVAPORATOR (for cooling only) Refrigerant enters the top of the lower shell or zone and is sprayed over the evaporator tube bundle. Heat from the liquid being chilled evaporates the refrigerant. 2. ABSORBER The refrigerant vapor is then drawn into the absorber side of the lower shell or zone. Here the vapor is absorbed by lithium bromide solution. Lithium bromide is, basically, similar to brine or salt water. But lithium bromide is a salt with an especially strong attraction for water. With the lithium bromide spray, it is as if hundreds of little sponges are sucking up the refrigerant vapor-called the "dilute solution" - which then collects in the bottom of the lower shell or zone. 3. HIGH PRESSURE GENERATOR The dilute solution is then pumped through the two heat exchangers where is preheated by hot concentrated solution from the generators. The heat exchangers improve the efficiency of the cycle by reducing the amount of gas/oil consumption required to heat the dilute solution in the high pressure generator. The dilute solution then flows to the high pressure generator shell (with a burner unit), beside the upper and lower shells. The dilute solution flows around the surfaces of the furnace tubes in the high pressure generator and is heated by gas combustion through the inside of furnace and tubes. The hot generator furnace and tubes allow the dilute solution to boil and it is further concentrated. Thus the dilute solution, straight from the high pressure generator is called the intermediate solution. The pressure in the high pressure generator is approximately 730mm Hg. The burner output is controlled by a valve in response to the cooling load required. Local superheat in the high pressure generator is avoided by the well distributed flow of the dilute solution between the shell and the outside of the furnace. 4. LOW PRESSURE GENERATOR The intermediate solution in the high pressure generator then flows to the upper shell or zone (low pressure generator & condenser) through the high temperature heat exchanger by gravity and pressure difference of both shells. The pressure in the upper shell is approximately one tenth that of the outside atmosphere, or 55mm Hg. The intermediate solution flows over the tubes and is reheated by refrigerant vapor-steam, generated previously in the high pressure generator. The refrigerant vapor has enough heat to make the solution more concentrated, releasing refrigerant vapor again at a lower pressure level and is drained to the condenser through a valve. The solution is now concentrated and flows through the heat exchanger, to the educator which is used to mix this solution with the re-diluted solution delivered from the solution pump. Then the mixed solution is sprayed on the absorber tubes. 5. CONDENSER The refrigerant flows to the condenser and is condensed. The liquid refrigerant, with the drained liquid from the low pressure generator, flows back to the lower shell, and is once again sprayed over the evaporator. The refrigerant cycle has been completed. Now the concentrated lithium bromide solution flows from the low pressure generator back to the absorber in the lower shell ready to absorb more refrigerant. Its cycle has also been completed. 3

H Y U N D A I C L I M A T E C O N T R O L C O., L T D. DOUBLE EFFECT ABSORPTION CHILLER SCHEMATIC High pressure generator Steam High temperature heat exchanger Drain Drain heat exchanger Cooling water Condenser Concentrated solution Intermediate concentrated solution Dilute solution Cooling water Solution pump II decrystallization system Lowpressure generator Absorber Evaporator Chilled water System & Drain Liquid refrigerant Refrigerant vapor Chilled water Cooling water Continuous purging system Low temperature heat exchanger Solution pump I Refrigerant pump Model : HTSN-1400

H Y U N D A I C L I M A T E C O N T R O L C O., L T D. STANDARD RATING DOUBLE EFFECT ABSORPTION CHILLER NOTE1 100 125 150 180 210 260 310 360 400 450 500 600 700 800 900 1000 1100 1250 1400 9

H Y U N D A I C L I M A T E C O N T R O L C O., L T D. SINGLE EFFECT ABSORPTION CHILLER SCHEMATIC Model : HSS-200

H Y U N D A I C L I M A T E C O N T R O L C O., L T D. STANDARD RATING SINGLE EFFECT ABSORPTION CHILLER NOTE1 11

Head Office 51-51, Mohwa-Ri, Oedong-Eup, Kyongju-si, Kyongbuk, Korea TEL : 82. 54. 745. 8661~5 FAX : 82. 54. 745. 8677 Homepage : http://www.hdcc.co.kr E-mail : hdcc@hdcc.co.kr Seoul Office Anam Tower #1116, #702-10, Yeoksam-Dong, Kangnam-Gu, Seoul, Korea TEL : 82. 2. 2009. 3121~2 FAX : 82. 2. 2009. 3120