MODELS LIST. Nominal Capacity RT
|
|
- Egbert Griffin
- 6 years ago
- Views:
Transcription
1
2 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION DATA MODELS LIST Nominal Capacity RT Refrigerant R134a Model Model Name LSBLG180H/Nb-M LSBLG10H/Nb-M LSBLG40H/Nb-M LSBLG300H/Nb-M LSBLG340H/Nb-M LSBLG380H/Nb-M LSBLG450H/Nb-M LSBLG500H/Nb-M LSBLG580H/Nb-M LSBLG640H/Nb-M LSBLG680H/Nb-M LSBLG760H/Nb-M LSBLG880H/Nb-M LSBLG1000H/Nb-M LSBLG1160H/Nb-M LSBLG180H/Nb-M Power Supply Ph, V, Hz
3 Flooded Screw Chiller Technical Sales Guide NOMENCLATURE LS B LG 180 H / Nb-M Model Model Description Options LS Water Chiller BLG Screw Compressor 180=18kW= 5 RT 10=1kW= 60 RT 40=38kW= 68 RT 300=96kW= 84 RT 340=340kW= 97 RT 380=383kW= 109 RT 180 Nominal Cooling Capacity 450=445kW= 16 RT 500=508kW= 144 RT 580=58kW= 165 RT 640=637kW= 181 RT 680=680kW= 193 RT 760=767kW= 18 RT 880=880kW= 50 RT 1000=1006kW= 86 RT 1160=1155kW= 38 RT 180=175kW= 36 RT H Flooded Nb Refrigeration Nb - R134a M Power Supply 380~415V,3ph,50Hz 3 FEATURES 3.1 Description With a wide cooling capacity range from 180 to 180 kw, GREE water-cooled screw chillers are being selected by more and more user for high efficiency and absolute dependability, GREE chillers are new widely applied in hotel, apartment, restaurant, office building, shopping mall, theater, gymnasium, hospital and so on, as well as supplying cool water for machine cooling purpose based on customized design all over the world. 3. Standard Specifications High Efficiency Full Load Operation Utilizing new screw compressor technology, the chillers meet or exceed the performance requirements of ASHRAE All system components are selected for optimum performance, including the condenser and evaporatars sizes. Excellent part load performance Because the units are not operated in full load condition most of the time, integrated part load value
4 (IPLV is an important performance indicator as outlined in standard ARI550/ Thanks to the patented design of two system parallel connection technology, a excellent IPLV performance has been come true. Capacity control Step or stepless capacity control are optional available, enable the unit be turned on with the least load to reduce startup current; and match up capability output of the units to actual load, which make the units operate steadily and reduce operation cost. Compressor Compact suction gas cooled semi-hermetic twin screw compressors with high efficiency performance curve. Compressors are provided with high efficiency suction strainer, oil trainer crank case heater and built in safety pressure relief valve. Compressors are also provided with intelligent electronics including motor temperature monitoring, phase reversal protection, manual reset lock-out and discharge temperature protection by PTC`s sensors. Optimized oil management ensure minimum refrigerant dilution in oil. Cooler Flooded type, shell-and-tube type with refrigerant evaporated inside the shell and water flowing in the tubes. With special high efficiency pool boiling heat-exchange tubes, which are expanded into a steel plate, the flooded type structure enable both the theories of pool boiling and nucleation boiling be well applied. Thus, the uniform refrigerant distribution, optimized temperature field of heat transferring, heightened evaporating temperature are achieved, and cooling capacity and EER of the unit are improved greatly. All evaporator are designed, constructed, inspected, and stamped according to the requirements of the ASME Boiler and Pressure Vessel Code. Condenser The condenser is shell-and-tube type, carbon steel fin and seamless high efficiency copper tubes with Refrigerant condensing inside the shell and water flowing through the tubes. Each condenser is designed, constructed, inspected, and stamped according to the requirements of the ASME Boiler and Pressure Vessel Code. Reliable oil return In order to ensure the oil in refrigeration system returning to compressor, the secondary oil separator with both centrifugal and absorption setups is used for improving the separating efficiency of oil from refrigerant, and a kind of injection equipment of refrigerant is specially designed which can be a great help of oil returning into compressor from refrigeration circuit; At the same time, the low oil location protection is applied to avoid the damnification to compressor from low oil to ensure reliability of the chiller. Strict Out-going test Each unit will be tested strictly not only on nominal operation condition but also minimum/maximum operation condition when leave factory by advanced on-line test system. 4
5 Flooded Screw Chiller Technical Sales Guide Control panel The Control panel provides a friendly interface for the operator with the color touch LCD(liquid crystal display which can display chiller's operating status, diagnostic message and date curve. Superior Controls GREE has provided the latest technology in controlling the chillers. The control logic is designed to provide maximum efficiency, to help provide continuous operation in unusual operating conditions through proactive controls, and to provide the history record of operating to aid in trouble shooting. Protocol for integrating with your building automation system (BAS are optional available. 3.3 Standard Accessories New throttling setup The new throttle setup can calculate optimal value of EER through control logic and adjust it automatically from actual value to optimal value because refrigerant flux and the high of the liquid in flooded evaporator can be control accurately by electronic expansion valve the efficiency of unit will be maximized in either full load operation or part load operation. Water flow switch A water flow switch is available for field installation in the chilled water piping to protect against evaporator freeze-up under low, or no flow conditions. Interface are provided in the unit control center for field connection of the water flow detection switch. The flow detection device need to be prepared on field. Pump control output Provides a digital output to control the secondary chilled water pump. Standard unit has one pump control output. Unit on-off switch ON-OFF switch is provided for manually switching the unit control circuit. Indicator lights LED lights of indicating power on of unit, running state and fault indications. Filter drier Refrigerant circuits are kept free of moisture, sludge, acid and oil contamination by filter drier. Under voltage and phase protection Protects against low voltage as well as phase fault reversal. Sight glass An color indicator shows moisture contents and provides a mean for checking the system refrigerant charge volume. Liquid line solenoid valve It will be closed when the compressor is off to prevent any liquid refrigerant from accumulating in the evaporator. 5
6 3.4 Standard Control & Safety Devices Safety valve Protecting the unit against high discharge pressure. Compressor built-in protection device Motor winding temperature, discharge gas temperature and phase reversal for direction of rotation. Crankcase heaters Protects the unit against from refrigerant migration, oil dilution and potential compressor failure. 4 PRODUCT DATA 4.1 Ratings Model Capacity(kW / RT EER LSBLG180H/Nb-M LSBLG10H/Nb-M LSBLG40H/Nb-M LSBLG300H/Nb-M LSBLG340H/Nb-M LSBLG380H/Nb-M LSBLG450H/Nb-M LSBLG500H/Nb-M LSBLG580H/Nb-M LSBLG640H/Nb-M LSBLG680H/Nb-M LSBLG760H/Nb-M LSBLG880H/Nb-M LSBLG1000H/Nb-M LSBLG1160H/Nb-M LSBLG180H/Nb-M 18/5 1/60 38/68 96/84 340/97 383/ /16 508/144 58/ / / /18 880/ / /38 175/ EER=Energy Efficiency Ratio at full load-the cooling capacity in Btu's per hour(btu/h divided by the power input in watts, expressed in Btu/h per watts((btu/h/watt. 6
7 Flooded Screw Chiller Technical Sales Guide 4. Physical Data Models Nominal Cooling Capacity Power Consumption Power Supply Running Control Safeties kw RT kw LSBLG H/Nb-M ~415V 3N 50Hz The multicolor touch LCD(liquid crystal Display High/low pressure protection, discharge temp. protection, anti-freeze water flow protection, low water flow protection,phase-sequence protection, compressor overload protection, low oil location protection, Safety valve, Crankcase heaters Compressor Type Refrigerant Type Cooler Water Flow Semi-Hermitic Screw Compressor R134a GPM Loss of Pressure Heat Exchanger Max.Pressure Water In/Out Pipe Diameter L/s Flooded Shell and Tube Evaporator 1.4 DN80 DN80 DN80 DN15 DN15 DN15 DN150 DN150 Condenser Water Flow GPM Loss of Pressure Heat Exchanger Shell and Tube Condenser Max. Pressure.0 Water In/Out Pipe Diameter L/s DN15 DN15 DN15 DN15 DN15 DN15 DN150 DN150 Height Dimension Width Depth Shipping Weights Operation Weights NOTES: 1 1 mm= in. Nominal Operate Condition. Inlet/Outlet chilled water temperature: 1/7 (44.6/53.6. Inlet/Outlet cooling water temperature: 30/35 (86.4/
8 Models Nominal Cooling Capacity Power Consumption Power Supply Running Control Safeties kw RT kw LSBLG H/Nb-M ~415V 3N 50Hz The multicolor touch LCD(liquid crystal Display High/low pressure protection, discharge temp. protection, anti-freeze water flow protection, low water flow protection,phase-sequence protection, compressor overload protection, low oil location protection, Safety valve, Crankcase heaters Compressor Type Refrigerant Type Cooler Water Flow Loss of Pressure Heat Exchanger Max.Pressure Water In/Out Pipe Diameter Semi-Hermitic Screw Compressor R134a L/s GPM Flooded Shell and Tube Evaporator 1.4 DN150 DN150 DN00 DN00 DN00 DN00 DN00 DN00 Condenser Water Flow Loss of Pressure Heat Exchanger GPM Shell and Tube Condenser Max. Pressure.0 Water In/Out Pipe Diameter L/s DN150 DN150 DN00 DN00 DN00 DN00 DN00 DN00 Height Dimension Width Depth Shipping Weights Operation Weights NOTES: 1 1 mm= in. Nominal Operate Condition. Inlet/Outlet chilled water temperature: 1/7 (44.6/53.6. Inlet/Outlet cooling water temperature: 30/35 (86.4/
9 Flooded Screw Chiller Technical Sales Guide 5 PERFORMANCE CORRECTION LSBLG180H/Nb-M LSBLG10H/Nb-M 50/71 30/65 10/60 190/54 170/48 80/80 60/74 40/68 0/63 00/ ( ( ( ( LSBLG40H/Nb-M LSBLG300H/Nb-M 30/91 380/ /85 80/80 60/74 40/68 0/63 360/10 340/97 30/91 300/85 30/ ( ( ( ( 9
10 LSBLG340H/Nb-M LSBLG380H/Nb-M 410/ /18 390/ / /99 330/94 440/15 40/ / / / ( ( ( ( LSBLG450H/Nb-M LSBLG500H/Nb-M 50/ / /14 480/ / /15 40/ / /153 50/ /14 480/ ( ( ( ( 10
11 Flooded Screw Chiller Technical Sales Guide LSBLG580H/Nb-M LSBLG640H/Nb-M 700/ /07 670/ /18 610/ / / / / / / / ( ( ( ( LSBLG680H/Nb-M LSBLG760H/Nb-M 840/39 800/7 760/16 70/05 680/ /18 90/61 880/50 840/39 800/7 760/16 70/ ( ( ( ( 11
12 LSBLG880H/Nb-M LSBLG1000H/Nb-M 1040/ / /84 960/73 90/61 880/50 840/37 110/ / / /84 960/ ( ( ( ( LSBLG1160H/Nb-M LSBLG180H/Nb-M 130/ / /35 100/ / / / / / / / / / ( ( ( ( 1
13 Flooded Screw Chiller Technical Sales Guide 6 ANTIFREEZE A glycol solution is required when ambient temperature is below 0 and there is water in evaporator or condenser for avoiding the copper in evaporate or condenser is frosted cleft. The use of glycol will reduce the performance of the unit depending on concentration. % By Weight Freezing Point -3.3(6-7.8( (7-1.7( (-9 Ambient Temperature 8.3(47-1.7(9-6.7(0-16.7( -6.7(-16 Cooling Capacity Correction Factor Water Flow Correction Factor Pressure Drop Correction Factor INSTALLATION 7.1 Dimensions Cooling water outlet Cooling water inlet Chilled water inlet Chilled water outlet The unit dimensions with single compressor LSBLG180H/Nb-M LSBLG640H/Nb-M Cooling water outlet Cooling water intlet Chilled water intlet Chilled water outtlet The unit dimensions with two compressors LSBLG680H/Nb-M LSBLG180H/Nb-M 13
14 Unit mm Models A B C D E F G H J LSBLG180H/Nb-M LSBLG10H/Nb-M LSBLG40H/Nb-M LSBLG300H/Nb-M LSBLG340H/Nb-M LSBLG380H/Nb-M LSBLG450H/Nb-M LSBLG500H/Nb-M LSBLG580H/Nb-M LSBLG640H/Nb-M LSBLG680H/Nb-M LSBLG760H/Nb-M LSBLG880H/Nb-M LSBLG1000H/Nb-M LSBLG1160H/Nb-M LSBLG180H/Nb-M Rigging Instruction Attention to Riggers Center of gravity is not unit center line. Ensure center of gravity aligns with the main lifting point before lifting. Use spreader bar when rigging, to prevent the slings during the unit. Caution All panels should be in place when rigging. Care must be taken to avoid damage to the pipeline during handing. Rigging schematic plan according to the indication on unit 14
15 Flooded Screw Chiller Technical Sales Guide 7.3 Mounting Location Footing of the unit Micro-stone concrete C300# (Secondary pour 100 Foundion bolt M18 (Self-supply by consumer Installation plane concrete C300# Compace soil Gutter Shock pad (Self-supply by consumer Back Left Right Front [Front of the unit] Mounting location schematic plan Unit mm Models A B D M K LSBLG180H/Nb-M LSBLG10H/Nb-M LSBLG40H/Nb-M LSBLG300H/Nb-M LSBLG340H/Nb-M LSBLG380H/Nb-M LSBLG450H/Nb-M LSBLG500H/Nb-M LSBLG580H/Nb-M LSBLG640H/Nb-M LSBLG680H/Nb-M LSBLG760H/Nb-M LSBLG880H/Nb-M LSBLG1000H/Nb-M LSBLG1160H/Nb-M LSBLG180H/Nb-M
16 F 7.4 Installation Clearance H G I Installation clearance schematic plan Unit mm Models D F G H I LSBLG180H/Nb-M LSBLG10H/Nb-M LSBLG40H/Nb-M LSBLG300H/Nb-M LSBLG340H/Nb-M LSBLG380H/Nb-M LSBLG450H/Nb-M LSBLG500H/Nb-M LSBLG580H/Nb-M LSBLG640H/Nb-M LSBLG680H/Nb-M LSBLG760H/Nb-M LSBLG880H/Nb-M LSBLG1000H/Nb-M LSBLG1160H/Nb-M LSBLG180H/Nb-M
17 Flooded Screw Chiller Technical Sales Guide 8 ELECTRICAL DATA Model LSBLG180H/Nb-M LSBLG10H/Nb-M LSBLG40H/Nb-M LSBLG300H/Nb-M LSBLG340H/Nb-M LSBLG380H/Nb-M LSBLG450H/Nb-M LSBLG500H/Nb-M Sectional Area of Electrical Wire 35mm 35mm 35mm 50mm 70mm 95mm 95mm 95mm Model LSBLG580H/Nb-M LSBLG640H/Nb-M LSBLG680H/Nb-M LSBLG760H/Nb-M LSBLG880H/Nb-M LSBLG1000H/Nb-M LSBLG1160H/Nb-M LSBLG180H/Nb-M Sectional Area of Electrical Wire 150mm 150mm 150mm 185mm 40mm 150mm 150mm 185mm 9 SCHEMATIC WIRING DIAGRAM Main Power Entrance Field Control Wiring Entrance Typical Control Box Lcations And Field Wiring (LSBLG180H/Nb-M~LSBLG640H/Nb-M Field Control Wiring Entrance Main Power Entrance Typical Control Box Locations And Field Wiring (LSBLG680H/Nb-M~LSBLG180H/Nb-M Terminal Block L1 L L3 N E L1 L L3 N Field Provided Unit Power Supply Legend: Field Power Wiring Field Control Wiring Chilled water pump contactor(0v~ Cooling water pump contactor(0~ 3 Cooling fan contactor(0~ 4, Power breakers voltage releases(0v~(option 1 Remote switch Chilled water flow switch 3 Cooling water flow switch 17
18 10 MICROPROCESSOR CONTROLLER After press startup button, the unit will be started-up after controls detect all inputed signals are normal. controls auto control compressor startup, capacity adjust and shutdown through the temperature of chilled in water detected; auto control the step of electrical expanding valve through degree of superheat temperature detected; auto prevent the chilled of water in evaporator to be frostbite through the prevent frostbite temperature detected; auto control startup or shutdown of cooling fan tower through the temperature of cooling in water detected; auto control overheat of the cooling water in condenser through the temperature of cooling out water detected; auto adjust the capacity of compressor through the press of evaporator and condense detected, so the unit can work in safe state once compressor startup, besides comes protective signals, operating time should be at least 6 min(adjustable,although the temperature of chilled in water has reached unload shutdown temperature after compressor stop, unit should be re-startup after at least 10 min(adjustable. after unit startup, firstly open chilled water pump, then open cooling water pump, and then open the cooling fan tower, at last control the startup or shutdown of compressor, adjust the capacity accordingto chilled in water. When unit shutdown, firstly shut down compressor, then close cooling fan tower, and then close cooling water pump, at last close chilled water pump. 11APPLICATION DATA 11.1 Work Range Leaving water temperature Chilled water Temperature difference of outlet and inlet water( / Leaving water temperature Cooling water Temperature difference of outlet and inlet water( / Installation Footing a. The installation footing is required with concrete or steel structure,can bear the Operation Weight of the unit, with a level upper plane, and preform gutter. b. According to Mounting Location schematic plan, place steel plate and shock pad exactly on the installation footing, proceed secondary pour after the unit and foundation bolt is placed. The foundation bolt is out about 100 mm of installation plane usually Installation Clearance a. Need to perform installation, operation and maintenance spacing. b. Ensure the unit keep out of insolation and rain away from fire, combustibles, corrosive gas and discharge gas; preform ventilation spacing; should have suitable measure to reduce noise and shock. 18
19
Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M
1. MODELS LIST 1. NOMENCLATURE 3 3. FEATURES 3 4. PRODUCT DATA 6 5. PERFORMANCE CORRECTION 9 6. ANTIFREEZE 1 7. INSTALLATION 13 8. ELECTRICAL DATA 16 9. ELECTRICAL DIAGRAM 17 10. SCHEMATIC WIRING DIAGRAM
More informationCASE STUDY AIR-CONDITIONERS
CASE STUDY AIR-CONDITIONERS An Investment in Longer Lasting Quality ABOUT US BT Commercial Ltd. is a dynamic and diversified company, which has been in operation since 1992. Our company, which is growing
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationContents 1. MODELS LIST 9. ELECTRICAL DIAGRAM MODELS LIST
Contents 1. MODELS LIST 2.NOMENCLATURE 3.FEATURES 4.PRODUCT DATA 5.PERFORMANCE CORRECTION 6.ANTIFREEZE 7.INSTALLATION 8.ELECTRICAL DATA 9. ELECTRICAL DIAGRAM 10.FIELD WIRING DIAGRAM 11.MICROPROCESSOR CONTROLLER
More informationDTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5
Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationSECTION ROTARY-SCREW WATER CHILLERS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.
More informationC. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.
SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers
More information60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS
R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationModular Air Cooled Scroll Chillers
Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube
More informationChapter-8 Capacity Control of Refrigeration Systems
Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control
More informationCall us today! (800)
150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More informationSECTION AIR COOLED WATER CHILLERS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2
More informationORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.
ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial
More informationTechnical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview
Product overview 1 Company Profile Yantai Oceanair Refrigeration & Air-Conditioning Co.,Ltd. was established in 2004 and has been listed on the New OTCBB (Stock Code: 831870). We are mainly specialized
More information30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz
30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More information30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw
Water-Cooled Screw Compressor Liquid Chillers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 0HC - 50 HZ Nominal
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationGuide Specifications
Guide Specifications Hot Water fired Adsorption Liquid Chillers Bry-Air Adsorption Chiller Overview The chiller shall be a Bry-Air ADC series. The chiller shall consist of a robust, compact, packaged chiller
More informationExclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Page 236423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical Plant
More information30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw
Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER 30G - 50 Hz Nominal cooling capacity 384-03 kw The 30G units are air-cooled chillers, designed from the ground up to meet the needs of today and
More informationprecision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs
next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled
More informationLiebert CSU3000 Chiller
CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More information30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw
AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of
More information30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation
Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationAll series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.
HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationWater-Cooled Dual Compressor Screw Chiller
Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,
More informationPathfinder Air-Cooled Single-Screw Chiller/Heat Pump
Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationDate: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days
Proposal Trane A Division of American Standard Inc. Prepared For: John Weston Desmet Ballestra Job Name: LAUER1 Biodiesel Chiller Pennsylvania Date: August 21, 2006 Proposal Number: G1-95502-1 Engineer:
More informationDAIKIN Modular Inverter Air Cooled Chiller
DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationChiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.
TURBOCOR COMPRESOR CHILLERS General Description Microprocessor controlled, water chiller using HFC 134a refrigerant, two stage centrifugal oil free variable speed compressor's and electronic expansion
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationProduct Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons
Product Data 07DA, DB 07EA, EB, ED Condensing Units 3 to 40 Nominal Tons 06D, 06E Compressors An excellent choice for your built-up system Carrier 07 Series condensing units built for the engineer who
More informationUltimate energy saving technology
Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More information30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient
PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme
More informationUltimate energy saving technology
Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today
More information30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw
Air-Cooled Screw Compressor Liquid Chillers GLOAL CHILLER Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 30G 50
More informationMAC-A R410A Series Air cooled Modular Chiller
Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationA. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.
15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationMAC-D R410A Series Air-cooled Modular Chiller/Heat pump
Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationGP SERIES Packaged Chillers
Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered
More informationModular Water Cooled Water Chiller
Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd. Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized
More informationAir-Cooled Global Chiller
Product Manual PM 970 Group: Chiller Effective: June 1997 Supersedes: None Air-Cooled Global Chiller Type AGR 055AS through 100AS Reciprocating Compressor with R-22 60 hertz 1997 McQuay International Table
More informationSECTION CHILLERS
SECTION 15650 PART I - GENERAL 1.01 WORK INCLUDED A. Extent of work shall be as indicated on Drawings and provisions of this section, including schedules and equipment lists associated with either Drawings
More informationProduct Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.
Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing
More informationERACS.C-N Higher efficiency air-cooled screw pump
ELITE TM Series COOLING ERACS.C-N Higher efficiency air-cooled screw pump HEATING HOT WATER Cooling Capacity:5~1341 (7~381 Tons) Heating Capacity:60~1363 (74~388 Tons) High Efficiency Air-cooled Heat Pump
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationAQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual
u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationHITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -
HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000
More information30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw
Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationLeadership, Innovation, Advanced Technology Synergise Here!
Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified
More informationPS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017
PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE Master Rack Compressor Sequencer 7/21/2017 1 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PARALLEL RACK NOMENCLATURE...
More informationAIR COOLED PACKAGED CHILLER
AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its
More informationAir-Cooled Screw Compressor Chillers
Catalog Cat AGSD-1 Air-Cooled Screw Compressor Chillers Models AGS 225D to AGS 450D 210 to 450 Tons, 740 to 1580 kw Packaged or with Remote Evaporator or Chilled Water Pump Package R-134a, Hz Engineered
More informationWater Chiller Solutions. A solution to every water cooling need.
Water Chiller Solutions A solution to every water cooling need. During the harsh summers of Middle East, the ambient temperature is very high and it can go up to as much as 52 o C. Naturally, in such conditions,
More informationORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS
ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0
More informationTrouble Shooting Guide FAA, 3-phase (D3631)
Trouble Shooting Guide FAA, 3-phase (D3631) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage tripped Loose
More informationAir-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a
Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition
More informationHYDROCIAT LW R407C. Water cooled chillers USE RANGE
Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationKelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw
Cooling Capacity: 280 ~ 1840 kw Water cooled liquid chillers in A class energy efficiency for indoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded
More informationSeries. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost
LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationDOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,
DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationkw COOLING kw HEATING
Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationMLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers
MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS
More informationPage 1 of Relevant Provincial Jurisdictional legislation.
Page 1 of 15 1. Act, Regulations and Codes (6.7%): To locate information relating to the staffing, operation, maintenance, inspection, and testing of the refrigeration plant and its equipment using reference
More informationAir Cooled Scroll Chiller
Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water
More informationGeneSys. Air-Cooled Screw Compressor Chillers. Catalog
Catalog Cat AGS-2 GeneSys Air-Cooled Screw Compressor Chillers Models AGS 120C to AGS 210C 110 to 210 Tons, 420 to 740 kw Packaged and with Remote Evaporator R-134a, 60 Hz Engineered for flexibility and
More informationMODULAR CHILLER. R410a R22
Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationProduct Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C
Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and
More informationAs a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.
NOMENCLATURE INTRODUCTION The HTT HWDX water-cooled chillers range is the latest addition to HTT s growing family of commercial products, featuring the most current technologies advances. The HWDX main
More informationCutting Edge Compressor Technology
CHILLER MODULES Cutting Edge Compressor Technology MagLev ; magnetic levitation Oil Free design Quieter than typical background noise Soft start; pulls only 2 amps at 460V Superior part load efficiency
More informationWater-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X
Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,
More information30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:
0RB/RQ ircooled Liquid Chiller Reversible irtowater Heat Pump 0RB: Nominal cooling capacity: 159758 0RQ: Nominal cooling capacity: 160 Nominal heating capacity: 1895 Features The quasnap Puron liquid chillers/airtowater
More informationZeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017
Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More information