s Sensor (S11) 3038 µs/cm 77.1 F Generic AI (S21) 30.5% Generic AI (S22) 37.9% List of possible s: Contacting Conductivity Electrodeless Conductivity Temperature ph ORP Disinfection Generic Transmitter/AI Monitor DI State Flow Meter, Contactor type Flow Meter, Paddlewheel type Feed Monitor Virtual Calculation Virtual Raw Value MAIN MENU/HOME SCREEN OVERVIEW HOME SCREEN (example) CCond SENSOR (S11) (S1) 3041 µs/cm 77.0 F MAIN MENU s Additional Confg Settings: Remote Communications (Modbus) On/ (R1) Flow Timer (R2) Alarm R1 R2 R3 R4 R5 R6 List of possible : On/ control mode Flow Timer control mode Percent Timer control mode Alarm Output mode Time Proportional control mode Manual control mode Pulse Proportional control mode PID control mode Dual Setpoint mode Timer control mode Probe Wash control mode Spike control mode Lag Output control mode Analog Ouput, Retransmit mode Analog Output, Proportional control mode Analog Output, PID control mode Analog Output, Manual mode Analog Output, Flow Proportional mode List of all Active To HOME SCREEN Settings Sensor DI Relay Low Axis Limit High Axis Limit µs/cm 3036 3035 14-Nov 3034 3033 3032 3031 Time Range 10 SENSOR Minutes(S1) 30 Minutes 1 Hour 2½ Hours X Hand Auto CCond (S11) 10.35 10.40 10.45 On/ (R2) 10 Minutes Additional Settings: Time Range More possible settings: 8 Hours 1 12 Hours 2 s 1 4 s ½ 35
s Sensor (S11) 3038 µs/cm 77.1 F Generic AI (S21) 30.5% Generic AI (S22) 37.9% s Calibration One Point Process Calibration One Point Buffer Calibration Two Point Buffer Calibration Three Point Buffer Calibration One Point Analog Calibration Two Point Analog Calibration Open Air Calibration (Cond) Zero Calibration (Disinfection) ssensor (S11) sensor type INPUTS Contacting Cond S11 (22) Additional Settings for Contacting Conductivity: Units Temp Compensation Temp Comp Factor Cell Constant Transmitter S11 (S12,13,21,22,23) AI Monitor S11 (S12,13,21,22,23) Additional Settings for Transmitter and AI Monitor: Units 4 ma Value 20 ma Value Electrodeless Cond S11 (S21) Additional Settings for Electrodeless Conductivity: Cell Constant Installation Factor Units Range Temp Compensation Temp Comp Factor Fluorometer S11 (12,13, 21,22, 23) Additional Settings for Fluorometer: Max Sensor Range Dye / Product Ratio Temperature S12 (S22) ph S11 (S21) ORP S11 (S21) Disinfection S11 (S21) Generic S11 (S21) Additional Settings for Temperature Sensor: Element Additional Settings for ph Sensor: Electrode Buffers (ph only) Additional Settings for ORP Sensor: Additional Settings for Disinfection Sensor: Sensor Additional Settings for Generic Sensor: Units Sensor Slope Electrode (Linear Sensor set or Ion Selective) Low / High Range Calculation (V1-V2) 2 Raw Value (V1-V2) DI State (D1-D6) Open SENSOR Message (S1) Closed Message Interlock Alarm Paddlewheel Flowmeter (D1-D6) Totalizer Alarm 36 Contactor Flowmeter (D1-D6) Totalizer Alarm Feed Monitor (D1-D6) SENSOR Totalizer (S1) Alarm Additional Settings for Virtual Calculation Low Range High Range Additional Settings for Raw Value: Smoothing factor Additional Settings for DI State: Total Time Additional Settings for Contactor, Flowmeter: Volume/Contact Flow Units Additional Settings for Paddlewheel, Flowmeter: K Factor Flow Units Rate Units Additional Settings for Feed Monitor: Total Alarm Flow Units Flow Alarm Rate Units Flow Alarm Delay Flow Alarm Clear Output Reprime Time Volume/Contact VIRTUAL INPUTS DIGITAL INPUTS
On/ (R1) Inhibitor (R2) On/ (R1) output type On/ (R1-R6) Flow Timer (R1-R6) Feed Accumulated Volume Bleed & Feed (R1-R6) SENSOR Setting (S1) Feed Time Limit Bleed then Feed (R1-R6) SENSOR (S1) Feed Percentage Feed Time Limit Reset Timer Percent Timer (R1-R6) SENSOR (S1) Sample Period Feed Percentage Alarm (R1-R6) SENSOR Setting (S1) Alarm Select Output Biocide Timer (R1-R6) SENSOR Setting (S1) s Additional Settings for On/OFF : Delay Time Additional Settings for Flow Timer : Flow Flow 2 Additional Settings for Bleed & Feed : Bleed Additional Settings for Bleed then Feed : Bleed Additional Settings for Percent Timer : Additional Settings for Biocide Timer : Bleed Prebleed Time Prebleed To Cond Bleed Lockout Add Last Missed Additional Settings for Alarm : Int. Sampling (R1-R6) Manual (R1-R16) Delay Time Pulse Prop (R1-R6) SENSOR Setting (S1) Minimum/Maximum Output PID Control (R1-R6) SENSOR Setting (S1) Gain Proportional Gain Dual Setpoint (R1-R6) 2 Timer Control (R1-R6) SENSOR (S1) Hourly Events Per Probe Wash (R1-R6) Hourly Events Per Spike Control (R1-R6) Set point Spike Set point OUTPUTS (RELAYS R1-R6) Additional Settings for Intermittent Sampling : Sample Time Min Relay Cycle Hold Time Maximum Blowdown Wait Time Cond Trap Sample Additional Settings for Manual : Additional Settings for Pulse Prop : Maximum Rate Additional Settings for PID Control : Integral Time Integral Gain Minimum Derivative Time Maximum Derivative Gain Gain Form Reset PID Integral Minimum Output Maximum Output Maximum Rate Additional Settings for Dual Setpoint : Delay Time Additional Settings for Timer Control : Add Last Missed Additional Settings for Probe Wash : 2 Sensor Hold Time Additional Settings for Spike Control : Event 1 (through 8) Time Prop (R1-R6) Sample Period Additional Settings for Time Prop : Lag Control (R1-R6) Lead Wear Leveling* Wear Cycle Time* Additional Settings for Lag Control : Activation * Min Relay Cycle 2 Delay Time* * See section 5.3.18 37
OUTPUTS (ANALOG A1-A2) On/ (R1) Inhibitor (R2) s On/ (R1) output type Retransmit (A1-A2) 4 ma Value 20 ma Value Additional settings for Retransmit : Proportional Control (A1-A2) Min Output PID Control (A1) Gain Proportional Gain Manual Control (A1-A2) Additional Settings for Proportional Control : Max Output Output Additional Settings for PID Control : Integral Time Integral Gain Derivative Time Output Derivative Gain Reset PID Integral Min Output Max Output Max Rate Minimum Maximum Gain Form Additional Settings for Manual Control : Flow Prop (A1-A2) Target Pump Capacity Pump Setting Lag Output (A1-A2) Lead Additional Settings for Flow Prop Control : Specific Gravity Flow Output Additional settings for Lag Output : Wear Leveling Wear Cycle Time 38
HOME SCREEN (example) CCond (S11) 3041 µs/cm 77.0 F CONFIG MENU s Date Time Location Controller Log Out Security Local Password DHCP SENSOR Setting (S1) Controller IP Address Network Netmask Network Gateway SENSOR (S1) DHCP Status Controller IP Address Network Netmask Remote Communications SENSOR Comm (S1) Status Data Format Data Port Verbose Logging Additional : Global Units Temperature Units Alarm Delay HVAC s Language Additional : DNS Server TCP Timeout VTouch Status LiveConnect Status Update Period Reply Timeout Additional : Network Gateway DNS Server MAC Address Last VTouch Data Last VTouch Home 1 Home 2 Home 3 Home 4 File SENSOR Transfer (S1) Status Data Log Range Log Frequency Export Data Log File Controller Product Serial Number Controller Board Additional Settings: Remote Communnications (Modbus) Additional : Home 5 Home 6 Home 7 Home 8 Adjust Display Key Beep Auto Dim Time Additional : Export Event Log Export System Log Export User File Import User File Restore Default Software Upgrade Additional : Power Board Sensor Board #1 Sensor Board #2 Network Board AO Board Last Data Log Battery Power Internal Temp 1 Internal Temp 2 Internal Temp 3 Internal Temp 4 +5 Volt Supply +3.3 Volt Supply LCD Bias Voltage LCD Supply Report SENSOR #1 (S1) through #4 Email Adresses Email Server SMTP Server Additional : SMTP Port From Address ASMTP Username ASMTP Password Report #1-4 Settings: Report Email Recipients (Datalog/Summary Reports) Reports Per (Datalog/Summary Reports) (Datalog/Summary Reports) of Month (Datalog/Summary Reports) Report Time (Datalog/Summary Reports) Log Frequency (Datalog Report) Alarm ( Report) Select ( Report) Alarm Delay ( Report) 39