RIM SEAL SYSTEMS E-BOOK

Similar documents
FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Foam Products ENGLISH

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

Emergency shutdown systems. Procedures for bypassing ESD s

Second Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement

Home of reliable fire systems and products

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Inert Gas Fire Extinguishing System

Portable Fire Extinguishers

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

MODULE 2. Water-Based Suppression System Basics

The Science Behind Water Mist Protection of Typical Building Hazards

WATER MIST CONVENTION AND EXHIBITION

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

TECHNICAL SERVICES DIVISION

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Essentials of Fire Fighting 6 th Edition Firefighter I

TENDER CRFQ NO (E-TENDER REF NO.13020)

FIRE SUPPRESSION SYSTEM

Industrial Fire Brigade

Deluge & Preac tion Systems

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

BOC FS125 The Fire Extinguishing Solution

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

Exterior Fire Protection for High-Rise Buildings

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2

CO 2 Fire Extinguishing Systems

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Foam Systems U.S. Quick Reference Guide

Explosion Protection Engineering Principles

Max Fire Box Users Guide

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

New Millennium Wildfires: Paradigm Shifts for the 21 st Century: Assessing the Home Ignition Zone

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Firefighting. It is the temperature at which a substance will continue to burn, when ignited.

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

Local area fire protection using automatic suppression

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

EXTINGUISHING SYSTEM DETECTION AND CONTROL

automatic FiReFighTing SYSTeMS in PainT booths

TRIPR FLAMMABLE LIQUID UNIT TRAINS

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

SECURITY BLANKET Foam Fire Protection Products

Fire suppression systems for server rooms and data centres

Water Spray Systems: NFPA 15

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Above Ground Fuel Tank Requirements

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Fire Suppression Solutions

FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Portable Fire Extinguishers

Risk Management Department. Fire Extinguishers

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Twin-Agent Fire Fighting/Securing Systems Specifications

Fire Protection for Printing Machines with High Pressure Water Mist

& Fire Extinguisher Training

Dual Agent Unit w / Atmospheric Tank 200 Litres DAHR 01

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

THE IDEAL SOLUTION FOR KITCHENS

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

LESSON ONE FIREFIGHTER I Fire Behavior

Water Mist Fire Suppression

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

Fire and Gas Mapping- Updates to ISA84 TR7


DIRECTIVE NO: D-B

REPORT DOCUMENTATION PAGE

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

HEAD, CLARA & MARIA FIRE SAFETY PLAN

Aircraft Hangers. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

...extinguish it with a water spray.

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

BERMAD Fire Protection

Fire protection on chemical manufacturing sites

In the event of a halt in operations, the economic detriment to client and own business is in addition to the significant risks of consumer supply

A Global Leader in Explosion Protection

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

7 Fire Protection Systems Synopsis

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Transcription:

RIM SEAL SYSTEMS E-BOOK

RIM SEAL SYSTEMS Rim Seal floating roof tank fires represent one of the most dangerous threats for chemical and petrochemical storage farms. Industry data base shows that the oil industry has experienced several rim seal fires worldwide and some of them have developed into very large disasters. The causes of such disasters start with a rim seal fire that breaks out and grows undetected to a point that it spreads over the whole seal area and therefore the floating roof tank becomes surrounded by fire. In the worst case scenario, the intense heat radiated is absorbed partially by the tank shell and the pontoon until the point that the metal sheets lose their mechanical stability.

In such conditions the roof is no longer capable to float normally and can incline causing the roof to sink under the fuel with a consequential full surface fire. The most efficient way to avoid such fires to develop uncontrolled is that of installing a fire detection and suppression system. Such systems specified by NFPA 11 provides well proven methods of firefighting on floating roof tanks. However, such systems have a reaction time from fire detection to suppression that still leaves many oil companies concerned about the fire suppression performance. It is in fact paramount that a fire on a floating roof tank is to be suppressed as soon as possible. In this respect an additional system is supplied and integrated with the tank floating roof in order to provide early fire detection and instantaneous fire suppression within the rim seal zone. Such packages are capable of detecting instantaneously the fire outbreak in the rim seal zone and discharge in seconds a charge of fire extinguishing agent directly on the zone where the incipient fire has developed. This strategy have been proven successful when the rim seal packages are interconnected with the main foam system that is automatically activated seconds after the rim seal unit has discharged. For such reasons the units are instrumented with low and high pressure switches that monitors the status of the unit as well as its activation. Those instruments are connected to the main control system or F&G that manage the system logics and triggers the traditional foam system.

RIM SEAL UNIT ON A FLOATING ROOF TANK SA Fire Protection is an OEM of rim seal fire detection & suppression solutions for the protection of floating roof tanks. The solutions available are several and each one is designed to cope with a specific tank seal design, fuel content and environmental condition. The Rim Seal Fire Suppression Systems are available based on the following extinguishing agents: 1. Foam Based unit ( FFFP or AFFF ). 2. Gas Based unit ( HFC 227 ea or CF3I ). 1. FOAM BASED UNITS CAN BE CONFIGURED WITH THE FOLLOWING OPERATIONAL METHODS: 1. Deluge using a pneumatic linear heat detection system. 2. Deluge using an electrical linear heat detection system. 3. Wet type using closed head nozzles. Activation of the unit is via a propellant gas (nitrogen) which can be: 1. Stored in the foam tank (Stored Pressurized Unit). 2. Held into an internal or external cartridge (Un-Pressurized Unit). Foam Concentrate is available for the unit as per: 1. AFFF. 2. FFFP.

Discharge Nozzle: 1. Open type deluge (discharge is simultaneous through all package nozzles). 2. Closed type wet (discharge takes place only from those activated. Solution available only for stored pressure units). 2. GAS BASED UNITS CAN BE CONFIGURED WITH THE FOLLOWING OPERATIONAL METHODS: 1. Pre-action using a pneumatic linear heat detection system. 2. Pre-action using an electrical linear heat detection system. 3. Wet type using closed head nozzles. Discharge of the extinguishing gas is gained via a propellant gas (nitrogen) stored in the container. Gas extinguishing medium available for the unit are: 1. HFC 227 ea 2. CF3I Discharge Nozzle are closed head (discharge takes place only from those activated.)

Fire Protection Strategies: Actuation & Monitoring Rim Seal Units interconnection with the main control system or F&G can follow different wiring philosophy depending on the oil company fire protection strategy, rim seal unit type and monitoring requirement. Actuation of foam based rim seal units can be: 1. Automatic or Single Zone 2. Automatic & Remote Manual Multiple Zones Automatic or Single Zone Automatic actuation takes place via a pneumatic or an electric trim. When pneumatic only one unit will discharge where fire is detected. If fire spreads laterally other units will actuate accordingly. Remote actuation is possible installing a pilot SOV on each unit. Automatic & Remote Manual Multiple Zones Automatic Multiple Zone actuation is possible only for foam based rim seal units and it is achieved using a unique pneumatic fire detection tubing interconnected to each unit. Independently from fire location all units will discharge simultaneously. Remote actuation is achieved installing one or more SOV. Remote electric actuation is used when the units are to be activated from control room because used for vapor seal purpose. With some foam based rim seal units it is in fact possible to integrate their action for vapor containments aimed at protecting the floating roof tanks from being involved in a domino effect. In such cases, should a tank be involved in an uncontrolled full surface fire, the fire protection strategy calls for spraying the nearby tanks in order to cool the metal surface and prevent mechanical failure of the shell. The heat radiated though can be such that the fuel content inside the nearby tank heats up to a point that vapors are likely to be released from the seal. Such a mixture creates a flammable atmosphere above the tanks that can ignite under the radiated heat and cause the fire to spread known as the domino effect. AFFF Foam based unit sparying in between primary and secondary seal for vapor sealing purpose. The foam based rim seal units can be so designed to enter into the fire protection strategy of vapor containments creating an additional chemical seal on the radiated tanks in order to block the fuel vapors to exit the seal zone. With such a configuration it is possible to call the tank units into operation from the control room on each tank that is identified as being at risk. This additional measure of protection safeguard the tank from being involved into a domino effect increasing significantly the degree of safety of the whole tank farm.

Interfaces with control systems The interface with the control system or F&G main panel allows for monitoring the unit status in stand by condition and can be arranged according to different architectures depending on the degree of monitoring that wants to be achieved. 1. Point type interconnection 2. Cumulative Zoning Point Type interconnection Allows for monitoring of each unit located on the tank can be achieved via hardwired interconnection. Cumulative Zoning Allow for monitoring of the units as a group can be achieved via hardwired interconnection. Monitoring Control Panels can be connected to third party DCS or dedicated monitoring station (SCADA). Graphic maps will be displayed on the monitor screen indicating the status of all rim seal units. +39 050 70 03 06 info@sasrl.it