Table of Contents. Attachments Attachment A Photos Attachment B Site Map. Pages 3 of 9

Similar documents
2018 Annual Landfill Inspection Report

2018 Annual Landfill Inspection Report

2016 Annual Inspection Report

CLOSURE PLAN. CCR (b) GERS Landfill Area. Pirkey Power Plant Hallsville, Texas. October, 2016

CLOSURE PLAN. CCR (b) GERS Little Broad Run Landfill. Mountaineer Plant New Haven, West Virginia. October, 2016

CLOSURE PLAN. CFR (b) Fly Ash Reservoir II. Cardinal Plant Brilliant, Ohio. August, 2016

ENVIRONMENTAL ENGINEERING LAND SURVEYING

January 15, Karen O. Zwolak Tampa Electric Company 702 N. Franklin Street Tampa, FL

WET PONDS INSPECTION & MAINTENANCE CHECKLIST

NOTICE OF INTENT. Submitted To: Bremo Power Station 1038 Bremo Bluff Road Bremo Bluff, VA 23022

Chesapeake Energy Center. Submitted To: Chesapeake Energy Center 2701 Vepco Street Chesapeake, VA 23323

PROJECT SCOPE OF WORK CITY OF TOWN AND COUNTRY STORMWATER PROGRAM

OPERATIONS & MAINTENANCE MANUAL STORMWATER CONTROL STRUCTURE DRY DETENTION POND

OPERATIONS & MAINTENANCE MANUAL FOR POST CONSTRUCTION MEASURES

LANDFILL FINAL COVER AND MANAGEMENT OF LEACHATE SEEPS BELOW FINAL COVER

Inspection and Maintenance of Stormwater Best Management Practices

PROJECT SCOPE OF WORK CITY OF TOWN AND COUNTRY STORMWATER PROGRAM

Selecting the Right Closure Cap Option for Your Surface Impoundment or CCR Landfill

C. WATER. 1. Surface Water Runoff. See Section C.3, Flood Hazard/Mudflow Hazard, page Ground Water

Severn River Sub-Watershed: BMP 09-Retrofit

Landfill Closure, Intermediate Cover & Post-Closure Care. Municipal League Meeting

SECTION 6. Routine Maintenance Activity Details

Urban Conservation Practice Physical Effects ESTABLISHMENT, GROWTH, AND HARVEST NUTRIENT MANAGEMENT

Consulting Engineers and Scientists. Closure Plan. Submitted by: GEI Consultants, Inc Voyager Drive Green Bay, Wisconsin

STANDARD SPECIFICATIONS SECTION TEMPORARY EROSION AND SEDIMENT CONTROL

Shelbyville, KY Stormwater Best Management Practices. Section 2 EROSION PREVENTION AND SEDIMENT CONTROL PLAN

Alternative Cover Systems

POND Construction. Perry L. Oakes, PE State Conservation Engineer Natural Resources Conservation Service

MARBLE RIVER WIND POWER PROJECT Agricultural Protection Measures

Emergency Action Plan (EAP) for Coal Combustion Residuals (CCR) Units

A Collection and Removal System for Water in the Final Cover Drainage Layer

Poisoned Park? How Exide s Lead Contamination Risks Frisco s Grand Park

APPENDIX A SIMPLIFIED APPROACH TO STORMWATER MANAGEMENT FOR SMALL PROJECTS. In West Sadsbury Township, Chester County, Pennsylvania

C ity of Grande Prairie Development Services Department

4. CONCEPT PLAN DEVELOPMENT

When planning stormwater management facilities, the following principles shall be applied where possible.

Grass Buffer T-1. Description. Site Selection. Designing for Maintenance

Maintaining Your Neighborhood Stormwater Facilities How to identify stormwater facilities and keep them working

R1a: REINFORCED TURF TO REPLACE GRAVEL /GRASS PARKING ADJACENT TO SOUTH PENNSYLVANIA AVENUE.

Piles, Trenching, Inverters, Cables, Material Deliveries

INFRASTRUCTURE EXISTING INFRASTRUCTURE A. Circulation B. Signals C. Drainage D. Utilities

Exposed Geomembrane Cover Systems for Coal Ash Facilities

POLE BRIDGE ROAD NEAR FIVE LOT FARM

Huntington Stormwater Utility

Butte Creek Canyon. The New Road Built in April of 2015 by Signalized Intersection West, LLC. Presentation slides from December 2015 through June 2016

SOIL EROSION AND SEDIMENT CONTROL

OVERBURDEN MANAGEMENT PLAN APPENDIX ENVIRONMENTAL IMPACT STATEMENT

IMPROVED STORMWATER MANAGEMENT BMPS AND FLOOD PREPAREDNESS FOR 2016 EL NIÑO STORMS

AGENDA 2015 Community Stormwater Event

PRELIMINARY DRAINAGE REPORT LATHAM 200 MMSCFD GAS PROCESSING PLANT

DRAINAGE CALCULATIONS

DESIGN CRITERIA PACKAGE

E PL UNIVERSITY OF KENTUCKY LEXINGTON, KENTUCKY

Town of Essex Small Site Erosion Control Guide

Maintaining Your Neighborhood Stormwater Facilities

THE FOLLOWING IS AN EXCERPT FROM THE 2011 CITY OF SEATTLE STANDARD SPECIFICATIONS WITH MINOR CORRECTIONS MADE TO SECTION 9-03.SEATTLE.

GEOWEB slope & shoreline protection OVERVIEW

Safety Factor Assessment Plant McDonough-Atkinson Ash Pond 3 (AP-3) and Ash Pond 4 (AP-4)

CHECKLIST FOR PHASE II DRAINAGE REPORT

WQ-23 MOUNTAINOUS AND STEEP SLOPE SITES

STAFFORD TRACT NORTH OF US90A 1.0 INTRODUCTION 1.1 OBJECTIVE

Green City, Clean Waters

Technical Manual for Dam Owners Impact of Plants on Earthen Dams FEMA 534

A. INTRODUCTION AND SUMMARY OF FINDINGS B. EXISTING CONDITIONS. Table 10-1 Adjacent Storm Drains

Triangle Land Conservancy Conservation Area Monitoring Report Carolina North

SITE PLAN REVIEW APPLICATION AND CHECKLIST

Draft Rhode Island Stormwater Design and Installation Standards Manual

HIGH PERFORMANCE COAL COMBUSTION RESIDUAL (CCR) SOLUTIONS

EMERGENCY ACTION PLAN

YENNADON QUARRY, DOUSLAND, YELVERTON, DEVON, PL20 6NA EXTRACTIVE MATERIALS MANAGEMENT STATEMENT. For YENNADON STONE LTD

Operation & Maintenance of Stormwater Management Facilities

City of Stoughton Erosion Control Permit Application (effective 2/6/2018)

City of O Fallon, Missouri Stormwater Management Policy

EROSION & SEDIMENT CONTROL

April 29, 2015 NOTICE OF VIOLATION

A. Regional Detention Requirements

Archaeological evaluation at Willowdene, Chelmsford Road, Felsted, Essex

North Branch of Cypress Creek Ecological Restoration: A Comprehensive Approach to Stream Restoration

2 ALTERNATIVES AND OPTIONS

Invasive Plant Removal, Slope Stabilization, and Native Planting Manual

Public Information Centre # 2 Coronation Park Drainage Improvements Town of Oakville Municipal Class Environmental Assessment

SUPPORTING DOCUMENT STORMWATER POLLUTION PREVENTION PLAN (SWPPP) NARRATIVE

Pollutant Removal Benefits

HEAP LEACH PAD DESIGN AND CONSTRUCTION PRACTICES IN THE 21 ST CENTURY

PHASE III DRAINAGE REPORT

Key elements : Filter Strips must be designed within parameters required by the Fort Wayne s Development Standards/Criteria Manual.

VALLEY COUNTY MINIMUM STANDARDS FOR PRIVATE ROAD DESIGN AND CONSTRUCTION

GREEN SHEET ENVIRONMENTAL COMMITMENTS FOR THE IOWA HIGHWAY 100 EXTENSION

APPENDIX J PERFORMANCE STANDARDS FOR GRAVEL MINE, PIT MINE, OR QUARRY

Fellgate Estate, Jarrow Surface Water Management Plan 2015

APPENDIX C: STORMWATER CONTROL PLAN

Bioretention cell schematic key

Geosynthetics for Erosion Control and Reinforcement

Slope Stability in Harris County

City of Yelm. Public Works Department. July 29, Re: Stormwater Maintenance Re-Inspection Results

City of Waco Stormwater Management Regulations

City of Dade City AMEC Project No Dade City Stormwater Master Plan September 2012 Page 32

C-10. Disconnected Impervious Surface

Technical Specification Guidelines

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Transcription:

Table of Contents 1.0 Introduction...4 2.0 Description of Landfill...4 3.0 Review of Available Information...5 4.0 Inspection...5 4.1 Changes in Geometry since Last Inspection...5 4.2 Volume...5 4.3 Definitions of Observations and Deficiencies...5 4.4 Visual Inspection...6 4.5 Changes that Effect Stability or Operation...6 5.0 Summary of Findings...6 5.1 General Observations...6 5.2 Maintenance Items...7 5.3 Items to Monitor...7 5.4 Deficiencies...7 Attachments Attachment A Photos Attachment B Site Map Pages 3 of 9

1.0 INTRODUCTION This report was prepared by AEP- Geotechnical Engineering Services (GES) section, in part, to fulfill requirements of 40 CFR 257.84 and to provide the H.W. Pirkey Plant an evaluation of the facility. Mr. Dan Murphy, P.E. performed the 2017 inspection of the FGD Stackout Area at the H.W. Pirkey Plant. This report is a summary of the inspection and an assessment of the general condition of the facility. Mr. W. Greg Carter and Mr. Ron Franklin were the facility contacts. The inspection was performed on September 12, 2017. Weather conditions were cloudy and the temperature was in the mid 70 s ( F). There was no rainfall over the seven days prior to the inspection. 2.0 DESCRIPTION OF LANDFILL The FGD Stackout Area is designed to temporarily hold a stockpile of Coal Combustion Residuals (CCR) material until it is hauled off by dump trucks for permanent disposal in a separate landfill. A radial arm stacker deposits the CCR material on the ground surface within the footprint of the FGD Stackout Area. A stone berm with a geomembrane cover exists around the perimeter of the FGD Stackout Area to contain any contact water. All contact water drains by gravity to the lower surge pond or auxiliary surge pond for circulation back to the plant. There is concrete pad used for washing the tires of dump trucks that drive into the FGD Stack-out Area. These features, including the approximate limits of each area, are shown on the site map included as Attachment B. Selected photographs taken during the inspection and used to illustrate the visual observations presented in the report are presented in Attachment A. Additional inspection photos can be made available to the Plant upon request. 3.0 REVIEW OF AVAILABLE INFORMATION (257.84(b)(1)(i)) A review of available information regarding the status and condition of the FGD Stackout Area which include files available in the operating record, such as design and construction information, previous periodic structural stability assessments, previous 7 day inspection reports, and previous annual inspections has been conducted. Based on the review of the data there were no signs of actual or potential structural weakness or adverse conditions. 4.0 INSPECTION (257.84(b)(1)(ii)) 4.1 CHANGES IN GEOMETRY SINCE LAST INSPECTION (257.84(b)(2)(i)) A gravel berm with a geomembrane cover has been placed around the perimeter of the FGD Stackout Area since the 2016 Inspection. The purpose of the berm is to contain any runoff from the FGS Stackout Area. No other modifications have been made to the geometry of the FGD Stackout Area since the 2016 annual inspection. The geometry of the landfill has remained essential unchanged. 4.2 VOLUME (257.84(b)(2)(ii)) The total volume of ash that has passed through the FGD Stackout Area since September of 2016 estimated as 400,000 cubic yards. At the time of the inspection, it was estimated that about 10,000 cubic yards were stockpiled at the FGD Stackout Area. Pages 4 of 9

4.3 DEFINITIONS OF VISUAL OBSERVATIONS AND DEFICIENCIES This summary of the visual observations uses terms to describe the general appearance or condition of an observed item, activity or structure. The meaning of these terms is as follows: Good: A condition or activity that is generally better or slightly better than what is minimally expected or anticipated from a design or maintenance point of view. Fair/Satisfactory: A condition or activity that generally meets what is minimally expected or anticipated from a design or maintenance point of view. Poor: Minor: Significant: Excessive: A condition or activity that is generally below what is minimally expected or anticipated from a design or maintenance point of view. A reference to an observed item (e.g., erosion, seepage, vegetation, etc.) where the current maintenance condition is below what is normal or desired, but which is not currently causing concern from a structure safety or stability point of view. A reference to an observed item (e.g. erosion, seepage, vegetation, etc.) where the current maintenance program has neglected to improve the condition. Usually conditions that have been identified in the previous inspections, but have not been corrected. A reference to an observed item (e.g., erosion, seepage, vegetation, etc.) where the current maintenance condition is above or worse than what is normal or desired, and which may have affected the ability of the observer to properly evaluate the structure or particular area being observed or which may be a concern from a structure safety or stability point of view. This document also uses the definition of a deficiency as referenced in the CCR rule section 257.84(b)(5) Inspection Requirements for CCR Landfills. This definition has been assembled using the CCR rule preamble as well as guidance from MSHA, Qualifications for Impoundment Inspection CI-31, 2004. These guidance documents further elaborate on the definition of deficiency. Items not defined by deficiency are considered maintenance or items to be monitored. A deficiency is some evidence that a landfill has developed a problem that could impact the structural integrity of the landfill. There are four general categories of deficiencies. These four categories are described below: 1. Uncontrolled Seepage (Leachate Outbreak) Leachate outbreak is the uncontrolled release of leachate from the landfill. 2. Displacement of the Embankment Displacement of the embankment is large scale movement of part of the landfill. Common signs of displacement are cracks, scraps, bulges, depressions, sinkholes and slides. 3. Blockage of Control Features Blockage of Control Features is the restriction of flow at spillways, decant or pipe spillways, or drains. 4. Erosion Pages 5 of 9

Erosion is the gradual movement of surface material by water, wind or ice. Erosion is considered a deficiency when it is more than a minor routine maintenance item. 4.4 VISUAL INSPECTION (257.84(b)(1)(ii)) A visual inspection of the FGD Stackout Area was conducted to identify any signs of distress or malfunction of the landfill and appurtenant structures. Specific items inspected included all structural elements of the landfill perimeter berms, ponds and drainage patterns. Overall the facility is in good condition. The FGD Stackout Area is functioning as intended with no signs of potential structural weakness or conditions which are disrupting to the safe operation of the landfill. Inspection photos are included in Attachment A. Additional pictures taken during the inspection can be made available upon request. A site map presenting locations of the inspection observations is included in Attachment B. 1. An erosion rill has formed on the ground surface of the FGD Stackout Area as a result of concentrated water flowing from the truck washing pad. This erosion rill was estimated to be a maximum depth of about 2.5 feet. The truck washing pad is located within the FGD Stackout Area, approximately 175 feet northwest of the radial arm stacker. 2. The gravel berm with a geomembrane cover appeared to be in good condition. There was no evidence of holes, air/water pockets, or other signs of distress noted on the geomembrane. 3. A notch has formed at the northern end of the western gravel berm with a geomembrane cover. Non-contact water which drains along the railroad spur and the gravel berm with a geomembrane cover would enter the FGD Stackout Area and eventually end up in the surge pond. The surrounding grades and railroad spur in this area would not allow any contact water to escape through this notch and discharge off site. 4. There is no vegetal cover on the FGD Stackout Area due to material constantly being stockpile and removed. 5. Surface water runoff from along the eastern gravel berm with a geomembrane cover is conveyed underneath an access road via a steel pipe culvert. This culvert outlets onto a concrete slab with curb walls underneath the supports for the conveyor belt which feeds the radial arm stacker. A section of these curb walls have been notched out to allow surface water runoff to drain to the auxiliary surge pond. 6. Vehicle traffic enters the site from the south end. A gravel access road ramps over the top of the gravel berm covered with a geomembrane material. 4.5 CHANGES THAT EFFECT STABILITY OR OPERATION (257.84(b)(2)(iv)) Based on interviews with plant personnel and field observations there were no changes to the FGD Stackout Area since the last annual inspection that would affect the stability of the facility. Pages 6 of 9

5.0 SUMMARY OF FINDINGS 5.1 GENERAL OBSERVATIONS The following general observations were identified during the visual inspection: 1) In general, the FGD Stackout Area is functioning as intended and is in good condition. The Plant is performing regular maintenance and inspections as required. Several maintenance items have been noted and are described in Section 5.2. 5.2 MAINTENANCE ITEMS The following maintenance items were identified during the visual inspection, see site map for locations. Contact GES for specific recommendations regarding repairs: 1) Repair the erosion rill which has formed from concentrated water flowing from the truck washing area to the lower surge pond. Convey water from the truck washing area via a conduit, or protect the ground surface of the FGD Stackout Area from erosion. 5.3 ITEMS TO MONITOR There are no items to monitor as a result of observations made during this visual inspection: 5.4 DEFICIENCIES (257.84(b)(2)(iii)) There were no signs of structural weakness or disruptive conditions that were observed at the time of the inspection that would require additional investigation or remedial action. There were no deficiencies noted during this inspection or during any of the periodic 7-day inspections. A deficiency is defined as either: 1) Uncontrolled seepage (leachate outbreak), 2) Displacement of the embankment, 3) Blockage of control features, or 4) Erosion, more than minor maintenance. If any of these conditions occur before the next annual inspection contact AEP Geotechnical Engineering immediately. Pages 7 of 9

ATTACHMENT A Photos

September 12, 2017 Pirkey Power Plant FGD Stackout Area Inspection Page 1 Photo # 1 View of the FGD Stackout Area. Photo # 2 View of the erosion rill which has formed on the ground surface of the FGD Stackout Area as a result of concentrated flows from the vehicle wash pad. Photo # 3 Another view of the erosion rill on the ground surface of the FGD Stackout Area.

September 12, 2017 Pirkey Power Plant FGD Stackout Area Inspection Page 2 Photo # 4 View of the gravel berm with a geomembrane cover, facing south. Photo # 5 View of the notch which was formed at the northern end of the western gravel berm, allowing non-contact water from a small ditch adjacent to the railroad spur to enter into the FGD Stackout Area. Photo # 6 View of the gravel berm with a geomembrane cover, facing east.

September 12, 2017 Pirkey Power Plant FGD Stackout Area Inspection Page 3 Photo # 7 View of the eastern gravel berm with a geomembrane cover, facing north. Photo # 8 View of the outlet area of the steel culverts under the conveyor system which feeds the radial arm stacker. The notch in the curb is circled in white. Photo # 9 View of the culvert which directs runoff into the auxiliary surge pond. This culvert is downstream of the notch in the curb shown in Photo #8.

ATTACHMENT B Site Map