4iE Smart WiFi Thermostat Operating Guide

Similar documents
Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

On initial power up the thermostat will guide you through set up procedure for the following:

Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

ENTOUCH ONE USER GUIDE

Thermotouch Dual Dual Control Thermostat

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

Model: Available in: Sapphire Black and Glacier White. 1 Series

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

For Quick Set-Up go to Page 14

Lyric T6 & T6R Smart Thermostat

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Digital Thermostat Models: VS30W and VS30B

5230IG. Thermotouch 3.2aP Wireless Heating Thermostat

Operating Instructions

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Model: Available in : Sapphire Black and Glacier White. 1 Series

User Manual 561_U. WiFi Thermostat 561. Introduction 10/16

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

VisionPRO Series with RedLINK. User Guide

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Programmable Load Management Thermostat

Microelectronic Programmable Thermostat Owner s Manual. 1 J.H Form Number

stock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Digital Room Thermostat

CT2800 Programmable Thermostat

MCD User Manual

SMART THERMOSTAT WITH HOT WATER CONTROL

MagicStat CT3300 Programmable Thermostat

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

4 in 1 Digital Thermostat Control

T6 and T6R SMART THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

2018 thesimple, Inc.

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Cent$ible Power Users Manual

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Model: Edge-HC. 1 edge-hc

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Owner s Manual MODEL 8555

Model: Touch-RS. 1 Touch-RS

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

Installation, Configuration and User Manual

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

PRT-TS WiFi PRT-TS WiFi

Wiser Air User Interface Guide. Thermostat

TPOne-S. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Smart Thermostat. User Guide

CT2700 An Electronic Round Programmable Thermostat

IntelliSync Thermostat / Mobile App Frequently Asked Questions

Thermostats & smart controls. neohub+ UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

ELECTRONIC THERMOSTAT

CT500 Electronic Thermostat

Programmable Interactive User Manual

Manual & Technical Documentation V1.1

User Guide ecobee ecobee 477 Richmond St West 2nd Floor, Toronto Ontario M5V 3E7 Canada Toll free

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Bosch Connected Control

Model: RT510RF. Installation Manual

In Home Device Reference Guide. Brought to you by

T5+ Smart Thermostat Programmable Thermostat RCHT8610WF, RCHT8612WF

User Guide Danfoss Link A central controller for your entire house

Digital Electronic Thermostat With RF

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

Schluter -DITRA- HEAT-E-WiFi WiFi Touch Thermostat Interactive User Manual

Smart thermostat with Humidification/De-humidification control

Model: Slimline-N. 1 Slimline Series

Electronic Thermostat With RF

IDEAL E-NERGY Thermostat Touch type User Manual

SC Installation, Operation & Application Guide

: PRT / PRT PRT / PRT-N1

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

INSTRUCTION MANUAL P Heating and 1 Cooling

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

Model : PRT-EN Model: PRT-EN1

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

Touch Thermostat Interactive User Manual

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL

Digital Room Thermostat with Night Set-back

Door/Window Sensor. Set-Up Guide

TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675-TS32 3 Heating and 2 Cooling

T6 Pro Z-Wave. User Guide. Welcome. Need help? Get in touch. Programmable Thermostat

Digital Electronic Thermostat With RF

Transcription:

4IE-01-XX-01/4IE-01-XX-02 4iE Smart WiFi Thermostat Operating Guide See reverse for Installation Guide Smartphone control Use your smartphone, tablet or computer to control your heating online Self-adjusting Early Start technology ensures your home is at the right temperature at the right time WarmApps TM Get apps on your 4iE like traffic alerts and transport delays for your journey Energy saving advice The 4iE finds you better energy deals and smart ways to lower your usage Learning mode Set the 4iE to learn your schedule and program the heating itself Energy monitoring Graphical display of your energy usage and cost, with comparisons and forecasts. Smart Overrides TM Intuitive control of your heating. No need to reprogram if your routine changes Experts on hand Our UK based team is available to take you through the advice and help you save

2 Introduction The 4iE default screen is the home screen. Pressing the temperature figure in the centre of the screen allows you to override it, pressing the menu button allows you to start programming and setting up the 4iE. You ll often find a help button on pages with several options to give more information. If you do not press any button for 1 minute the 4iE screen will dim and revert to the home screen. To wake the 4iE just tap the screen or press Wake. Hold the power button on the bottom of the device for 3 seconds to turn the thermostat on or off. The icons at the bottom of the screen are your WarmApps. These can be set up on MyWarmup to show things like traffic and journey alerts, along with your energy saving advice MyWarmup You can also program and set-up your 4iE with your tablet or computer by visting my.warmup.com. If you use a smartphone to access MyWarmup you will be shown a mobile version which gives quick access to important features like Smart Overrides. 3

4 Getting Started On initial power up the 4iE will ask you to connect to a WiFi network. Once connected you will be required to create a MyWarmup account. If you skip the WiFi connection stage, you will be guided through a setup procedure as below and you can set up a MyWarmup account at any time in the future. Language Internet Settings Time Date Daylight Savings Heating type Temperature Display Theme Brightness Audio Feedback Floor type Heating control type Heating Program Schedule Energy Monitor settings Important! Ensure you choose the correct System Type. Electric (underfloor), Hydronic (underfloor) or Conventional (central heating with radiators). 5

6 Connect to MyWarmup Once your 4iE is powered up, you need to create your MyWarmup account. Navigate your web browser to my.warmup.com Enter your email address and create a password for your account. You will be sent a confirmation email when your account is set up. Make sure you check your spam folder as well as your inbox. When you ve received your account activation email, you can connect your 4iE to the account. Ensure your 4iE is connected to the internet. If you see an error icon on the homescreen like below, then your thermostat is not connected to the internet. If you can t connect to the internet, you can skip this stage and connect any time in the future. If you see these icons, call Warmup for 24/7/365 assistance on 0845 345 2288 Not connected to Server No WiFi Connection When your 4iE is connected to the internet, just enter the unique code displayed on the connection screen into MyWarmup. Your 4iE will then be connected. 7

8 Set your heating program You can choose to set a custom heating schedule, fixed temperature or a preset program designed for different rooms. To adjust the program just highlight the days that you want to program by pressing them, then press Program. You can select multiple days in any combination, such as weekdays only, to program separate weekday and weekend temperatures. To do this, program all the weekdays at once and then program the weekend when you re finished. The programming works by setting Comfort Periods of warm temperatures, shown with a green line. Any time not covered by a Comfort Period will use a lower Setback temperature to save energy. The default setback temperature is 16 C and you can change this once you ve set up your program if needed. You can add up to 5 Comfort Periods per day and when you ve set what you want, just press Accept. You ll see the summary of your program which you can edit by repeating the steps above, or just press Accept to set your program. Remember: The 4iE can also learn your schedule and program itself. To activate this, set it into Learning Mode on MyWarmup 9

Holiday Mode Holiday Mode allows you to override your schedule with a fixed temperature over a number of days. This helps you save energy when you know you ll be away for a while by setting a lower temperature. Holiday Mode can be found in the Program menu Just set the start and end times of your holiday, then set the temperature you want when you re away. Frost Protect Select Frost Protect mode to set your heating to 7 C. This will help protect your home from frost and will run continuously until you raise the temperature again. Preset Programs You can select a preset program schedule to get you started. You can edit the program whenever you like by following the steps in Set Your Heating Program Below is a summary of the Preset Programs 10 Pre-Set Setback Temperature Day Start Time End Time Target temperature Regulator value Bathroom 16 C Mon-Fri 06:00 08:00 22 70% (Reg: 0%) 19:00 21:00 20 50% Sat-Sun 07:00 11:00 22 70% 19:00 21:00 20 50% Kitchen 16 C Mon-Fri 06:00 08:00 21 50% (Reg: 0%) 18:00 22:00 21 50% Sat-Sun 07:00 11:00 21 50% 18:00 22:00 21 50% Bedroom 16 C Mon-Sun 06:00 08:00 21 70% (Reg: 0%) 20:00 23:00 20 50% Living Room 16 C Mon-Fri 18:00 21:30 21 50% (Reg: 0%) Sat-Sun 08:00 21:30 21 50% 11

12 Energy Monitor The 4iE learns how you use your system and how your house reacts to the heating and weather. It can give you an estimate of your energy usage and the running cost of your system. You will need to enter the power of your system, and in some cases, the efficiency. If you do not know these, speak to your installer or system manufacturer. You will also need to enter the cost of your energy, in order to calculate the running cost of your system. Press Energy Settings, and select if you have a single rate tariff or a standard/low energy tariff (where you have a discounted cost during part of the day). Enter your cost per KWH and relevant currency and, if required, the time the low energy tariff starts and stops and the discounted cost during that time. When you ve set up the Energy Monitor you can view the estimated usage or cost over a selected time period. If you have a standard/low energy tariff, the amount and cost of energy used during the standard period will be displayed in dark green and the amount used in the low period will be displayed in light geen 13

Settings The 4iE can be configured in different ways to suit you. The functions that can be accessed in the Settings menu include: Time Set time Set date Daylight savings manually set time (only available without WiFi connection) manually set date (only available without WiFi connection) set daylight savings (only available without WiFi connection) Heating preferences Temperature format Control air/floor Early Start choose celsius or farenheit use air or floor sensor as main measurement starts heating early so it s up to temperature at the right time Display/Audio Background Home screen style Display brightness Lock Audio Feedback change the screen background (upload your own on MyWarmup) choose a theme for the main screen change the screen brightness for normal use and standby set a lock code and limits for when the lock is active turn the click sound on or off Network 14 Choose a WiFi network and enter the password if required Advanced settings These options can affect the performance of your thermostat and should only be modified by an experienced professional or under the instruction of Warmup Technical Support Heater settings Heater limits Set the temperature limits for your floor type. User Defined lets you set custom limits Regulator Regulator mode controls the heating in 10 minute cycles. The number you enter is the number of minutes in every 10 minute cycle that the heating will be on. This mode will not use the floor or air sensors for measurement Fil Pilote This is a feature specifically for France. You must also connect Fil Pilote to terminal 1 Master/Relay This allows one thermostat to control another 1. Choose which thermostat is Master and which is Relay 2. Use low voltage cable to connect terminal 6 of both thermostats 3. Use low voltage cable to connect terminal 7 of both thermostats (in addition to floor sensor cables on the Master thermostat) 4. Set Relay thermostat to Relay mode first, then set the Master thermostat to Master mode 5. Program the Master thermostat. The Relay thermostat will no longer use its sensors, it will follow the Master thermostat Gradual Start Set the maximum temperature and time required to reach that temperature Probes Set the specification of the probes. You can also choose to hide the error message if you do not want to connect a probe Probe application Choose if the floor probe is being used as a Floor or Amb (ambient) sensor Offset Set the offset of the sensors to improve accuracy Reset This will restore all the factory default settings. You can also hold the button on the rear of the front module for 10 seconds to perform a system reset 15

Electric Underfloor Installation see numbering on diagram below 2. Connect to Power Supply (Live MAX 240V) 3. Connect to Power Supply (Neutral MAX 240V) 4. Connect to Warmup heater(s) (Neutral MAX 3600W/ 16 Amps) 5. Connect to Warmup heater(s) (Live MAX 3600W/ 16 Amps) 7. Connect to 1st wire of floor sensor (colour not important) 8. Connect to 2nd wire of floor sensor (colour not important) Hydronic Underfloor Installation see numbering on diagram below 2. Connect to Power Supply (Live MAX 240V) 3. Connect to Power Supply (Neutral MAX 240V) 4. Connect to wiring centre (Neutral if present MAX 3600W/ 16 Amps) 5. Connect to wiring centre (Switch Live MAX 3600W/ 16 Amps) 7. Connect to 1st wire of floor sensor (colour not important) 8. Connect to 2nd wire of floor sensor (colour not important) Central heating Installation see numbering on diagram below 2. Connect to Power Supply (Live MAX 240V) 3. Connect to Power Supply (Neutral MAX 240V) 4. Connect to Boiler circuit (Neutral if present MAX 3600W/ 16 Amps) 5. Connect to Boiler circuit (240V Switch Live MAX 3600W/ 16 Amps) For extra low voltage or volt-free systems a contactor must be used. Contact Warmup for more details. Connecting the 4iE directly to extra low voltage or volt-free boilers may cause damage to the boiler circuit. 16 Special Installation see numbering on diagram below Second sensor installation: (2nd floor probe or exterior probe) 6. Connect to 1st wire of external sensor/ 2nd floor sensor 7. Connect to 2nd wire of external sensor/ 2nd floor sensor Master/Relay installation: (connecting 2 stats together) 6. Connect to terminal 6 on other thermostat 7. Connect to terminal 7 on other thermostat 4 33 OB Mounting Thermostat thermostat 1. Push excess wire back through the wall box and insert thermostat back module into wall box. 2. Put fixing screws through mounting holes and tighten. 3. Ensure that thermostat is straight before tightening completely. 4. Replace thermostat front housing; i) align and sit front housing on to hinges, ii) push lower half of front housing until a click is heard. 5. Ensure front housing is securely fixed. 6. IMPORTANT: Tighten both retaining screws Powering Up You can now power up the thermostat and begin the programming process. An easy to follow menu will guide you through the rest. If you want to turn on / off the thermostat and heating system then hold down the recessed button on the bottom of the stat for 3 seconds Error Messages Your thermostat can give you two error indications: 1. er1 : This will occur if no floor sensor is detected 2. er2 : This will occur if the floor sensor has a short circuit 17

Introduction The 4iE thermostat is designed to aid in the comfort of your home by providing timed regulation of your heating system. The thermostat is designed to receive temperature input signals from the following sensors: 1. Air sensor located inside thermostat 2. Floor sensor installed in floor if using underfloor heating (see Warmup heater instructions for details) 3. Optional 2nd sensor The thermostat is not a safety device. In order to avoid damaging your system the correct system and floor type should be selected during the thermostat programming process. Electrical Specification: Supply voltage: 230V +/-15% at 50Hz Thermostat is not designed for use with intermittent power supply. Maximum Switch Load: 16A resistive Insulation Class : II Housing : IP33 Standards: EN60730-1 & EN60730-2-9 standards WARNING Important safety note This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should always isolate the power supply before attempting to install or repair the 4iE thermostat. The thermostat should not be put into operation unless you are certain that the entire heating installation complies with current general safety requirements for electrical installations. Electrical installation to be in accordance with latest IEE Wiring Regulations and appropriate Statutory Regulations. Location The thermostat should be installed inside a single gang electrical wall box that is at least 30mm deep. For optimal performance the thermostat should be located in an area with good ventilation. It should not be beside a drafty window/ door, in direct sunlight or above another heat generating device (e.g. radiator or TV). The thermostat is designed for operation between 0 C and 55 C with relative humidity less than 80%. 18 Installation Separate the front housing of thermostat from wall module: 1. Unscrew both closing screws (bottom of stat) until they will not turn any further. 2. Release front housing by gripping lower half of outer frame and pulling outwards then upwards 3. Place front housing somewhere safe 4. Run all wires to the wall box. Check to ensure that you have included the following: Power (Live and Neutral) Heater (Live and Neutral or Switch Live only) Floor sensor Fil pilote (if necessary) External/ 2nd floor Sensor (if necessary) 5. Pull wires through wall box and complete terminal wiring. IMPORTANT: Ensure that multi stranded wires are fully inserted into the terminals and secured tightly. Any loose strands should be trimmed as they could cause a short-circuit. If connecting more than two heaters, an electrical junction box will be required. NOTE: Always ensure that the sensor cable is installed in a separate conduit to the power cables supplying the thermostat and heating system. 19

Contact Us UK 0845 345 2288 702 & 704 Tudor Estate Abbey Road Park Royal London NW10 7UW Installation guide Warranty Warmup plc warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup s option. If the product is defective, please either, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or (ii) contact Warmup. Warmup will determine whether the product should be returned, or replaced. This warranty does not cover removal or reinstallation costs, and shall not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation or damage which occurred while the product was in the possession of a consumer. Warmup s sole responsibility shall be to repair or replace the product within the terms stated above. WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. This Warranty does not affect your statutory rights. Lifetime warranty also available. Contact Warmup or visit www.warmup.co.uk for details