Fire Alarm Advanced Application AEL-AD3A

Similar documents
Electrical Faults in Air Conditioning Systems Unit TEFA

Simple Compression Refrigeration Circuit Unit TSCR

Introduction to Refrigeration Unit TIR

THARALB. Refrigeration and Air Conditioning Unit (one condenser (air) and one evaporator (water)) PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION

THAR2LB. Refrigeration and Air Conditioning Unit (two condensers (water and air) and one evaporator (water))

THARA2B. Refrigeration and Air Conditioning Unit (one condenser (air) and two evaporators (water and air))

THAR22B. Heat Pump, Refrigeration and Air Conditioning Unit (two condensers (water and air) and two evaporators (water and air))

Centrifugal Fan Teaching Trainer HVCB. Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

Computer Controlled Recycle Loops Unit TRLC

BSR Addressable Fire Detection control panel. Installation operation manual

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TRX MAINS CONNECTION DIAGRAM

Model 17A00 Expansion Enclosure

Electronic Fire and Security Systems: Fire Alarm Systems Installation (SCQF level 6)

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

SUPREMATouch. Modular Fire & Gas Detection System

TECHNICAL AND VOCATIONAL EDUCATION ELECTRONICS LABORATORY (2TV)

Computer Controlled Heat Exchangers Training System TICC

Specification/ Data Sheet

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Conventional Releasing Control Panel

Electrical Installations Assembly Kits ELE-KITS

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

SUPREMATouch. Modular Fire & Gas Detection System

D3D Wi-Fi GSM Smart Alarm System -User Manual

System 800 Addressable Fire Detection & Alarm System

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

TECHNICAL DATA OBSOLETE

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Commercial and Light Industrial Fire Alarm Control Panel

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Control/Communicator Installation Manual

OPERATION AND INSTALLATION MANUAL

Release Control Fire Alarm Systems

good things in small packages

Basic Installation Manual

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

General Routing Interface

AND ARCHITECT SPECIFICATIONS

Deluge/Preaction Systems Annotated Instructor s Guide

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Deluge/Preaction Systems Annotated Instructor s Guide

FEC400 Series. Installation Manual

DS7400Xi Addressable Control/ Communicator

LifeAlarm Fire Alarm Control Panels

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

The EN54 Part 2 & 4 Fire System

Contents. Contents

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

AND ARCHITECT SPECIFICATIONS

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Refrigeration and Air-conditioning Technology. Open- and closed-loop control in refrigeration and air-conditioning systems

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

The EN54 Part 2 and 4 Fire System

EXTINGUISHING CONTROL PANEL PX2 SERIES

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Tips how to use the MAS Web tool

System Layout Annotated Instructor s Guide

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Digijock Home Security

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Installation Manual Premier 412/816/832. Issue 10

Section 9 System Operation

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24

Excel-EN Conventional Fire Control Panel

AUDIBLE SIGNALIZATION

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

DAI600 - Fire and Egress Door Assembly Inspection (Online Version) Syllabus

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Conventional Leaflets

1935, Lionel-Bertrand Blvd. Boisbriand, Quebec, Canada J7H 1N8 Tel.: (450) Fax: (450) Toll Free: (866)

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Multi-Zone Wireless Control Training Systems ( )

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Quick Programmer s Manual

Pioneer-R16 Gas Monitor Operator s Manual

LEVEL SWITCH NP-3T DL v1.0 Installation instructions Order no E-no

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

FireNET Plus Wiring Instructions

Transcription:

Engineering and Technical Teaching Equipment Fire Alarm Advanced Application AEL-AD3A INTRODUCTION Nowadays, alarms are used in a wide range of applications, such as fire detection, reminders or burglar alarms. Fire alarms are one of the most important security measures in our days, since they save lives and objects that would be lost if they did not exist. In addition, many of these alarms could be considered an active protection element when they include water sprinklers to help to extinguish the fire. ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) 1 Certificates ISO 14001 and ECO- Management and Audit Scheme (environmental management) Certificate and Worlddidac Member

GENERAL DESCRIPTION The Fire Alarm Advanced Application, AEL-AD3A, is designed with the aim to study different types of fire alarms. This complete application includes several types of sensors and alarms. The sensors included are a smoke detector, an ionized air detector and a temperature detector. These sensors activate the following alarms, also included: indoor siren, bell type alarm and a water solenoid valve to extinguish the fire. All these devices are controlled by a fire alarm station with battery, just in case the fire damages the electrical system. This application will be used by students to simulate several situations caused by fires and study the operation of each device. The AEL-AD3A includes the following modules: N-ALI02. Domestic Main Power Supply. N-ALI03. AC Auxiliary Power Supply. N-ALA02. Fire Alarm Station with Battery. N-SEL21. Indoor Siren. N-SEL17. Fire alarm bell + push-button. N-DET06. Smoke Detector. N-DET10. Water Electrovalve. N-DET21. Fire detector through ionization. N-DET22. Fire thermal detector. Expansion learning software: In addition, Edibon provides expansion learning software (AEL-AD3A/ICAI) to reinforce knowledge about this field. This software is formed by: ECM-SOF. EDIBON Classroom Manager (Instructor Software). ESL-SOF. EDIBON Student Labsoft (Student Software). The application AEL-AD3A can be mounted on rack (option A) or on rail (option B): Option A: This application needs the following racks: N-RACK-A. Optionally the AEL-WBR. Electrical Workbench (Rack) can be supplied to place the rack/s. Option B: This application can be mounted on rail. Optionally the AEL-WBC. Electrical Workbench (Rail) can be supplied to mount the modules. 2

SPECIFICATIONS The application includes the following modules: N-ALI02. Domestic Main Power Supply. Voltage supply (Single-Phase): 230 VAC, PH+N+G. ON-OFF removable key. Output Voltage Connections: N-ALI02 Two Single-Phase: 230 VAC. Single-Phase supply wire connecting plug. Differential magnetothermal, 2 poles, 25 A, 30 ma AC 6 KA. N-ALI03. AC Auxiliary Power Supply. Voltage supply (Single-Phase): 230 VAC PH+N+G. Output voltage: Single-Phase 24 VAC/12 VAC. N-ALI03 24 VDC. 0-24 VDC through potentiometer. N-ALA02. Fire alarm station with battery. Two control zones. Voltage supply, 230 VAC. Ground connection. N-ALA02 One input to activate the remote reset. One input to deactivate the programmed delays. Normally open fail contactor. Normally open alarm contactor. N-SEL21. Indoor Siren. Volume configuration through voltage, 12-24 VDC. 87-112 db. 12 30 ma. N-SEL21 32 tones. 3

N-SEL17. Fire alarm bell + push-button. Specifications Voltage supply, 19-28 VDC. Current consumption: 20 ma. Sound output: 95 db. Range of temperature: from -10 to +55ºC. N-SEL17 Pushbutton: Inner resistor: 100 ohm. Maximum current/voltage ratio: 2A/30 VDC. N-DET06. Smoke Detector. Output voltage, 9-28 VDC. Consumption of 85 ua in standby and <100 ma in alarm. N-DET06 Operation temperature from -10 to 70 ºC. N-DET10. Water solenoid valve. Voltage supply, 230 VAC. Normally closed position. Maximum pressure, 1.5 MPa. N-DET10 N-DET21. Fire detector through ionization. Working voltage, 9-28 VDC. Current of 85 ua in standby and <100 ma in alarm. Operation temperature from -10 to 70ºC. N-DET21 N-DET22. Fire thermal detector. Operation voltage: 9-28 VDC. Current of 85 ua in standby and <100 ma in alarm. Pre-warning indication: LED flickering. Alarm indication: fixed LED. N-DET22 Operation temperature from -10 to 70 ºC. All necessary cables to realize the practical exercises are included. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. 4

EXERCISES AND PRACTICAL POSSIBILITIES 1.- Checking and measuring the main power supply. 2.- Checking the working of the auxiliary power supply. 3.- Checking the operation and control of the Fire Alarm Station. 4.- Simulate situations in two safety zones managed by the Fire Alarm Station. 5.- Checking the operation of the air ionization sensor. 6.- Checking the operation of the temperature sensor. 7.- Checking the operation of the smoke detector. 8.- Checking the operation of the indoor siren. 9.- Checking the operation of the bell. 10.- Checking the operation of the water solenoid valve. 11.- Combine the different types of sensors with the alarms to simulate different situations. REQUIRED SERVICES - Electrical supply: single phase, 230 V./50 Hz. or 115 V./60 Hz. DIMENSIONS AND WEIGHTS AEL-AD3A: - Dimensions: 640 x 320 x 920 mm approx. (25.19 x 12.59 x 32.22 inches approx.) - Weight: 60 Kg approx. (132 pounds approx.) 5

Optional AEL-AD3A/ICAI. Interactive Computer Aided Instruction Software System: With no physical connection between unit and computer (PC), this complete software package consists of an Instructor Software (EDIBON Classroom Manager -ECM-SOF) totally integrated with the Student Software (EDIBON Student Labsoft -ESL- SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. Instructor Software - ECM-SOF. EDIBON Classroom Manager (Instructor Software). ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for individual students, workgroups, units, etc... so the teacher can know in real time the level of understanding of any student in the classroom. Innovative features: User Data Base Management. Administration and assignment of Workgroup, Task and Training sessions. Creation and Integration of Practical Exercises and Multimedia Resources. Custom Design of Evaluation Methods. Creation and assignment of Formulas & Equations. ECM-SOF. EDIBON Classroom Manager (Instructor Software) Application Main Screen Equation System Solver Engine. Updatable Contents. Report generation, User Progression Monitoring and Statistics. ECAL. EDIBON Calculations Program Package - Formula Editor Screen ETTE. EDIBON Training Test & Exam Program Package - Main Screen with Numeric Result Question ERS. EDIBON Results & Statistics Program Package - Student Scores Histogram 6

Innovative features: Student Log-In & Self-Registration. Existing Tasks checking & Monitoring. Optional Student Software - ESL-SOF. EDIBON Student Labsoft (Student Software). ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time, as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge. Default contents & scheduled tasks available to be used from the first session. Practical Exercises accomplishment by following the Manual provided by EDIBON. Evaluation Methods to prove your knowledge and progression. Test self-correction. ESL-SOF. EDIBON Student LabSoft (Student Software) Application Main Screen Calculations computing and plotting. Equation System Solver Engine. User Monitoring Learning & Printable Reports. Multimedia-Supported auxiliary resources. For more information see ICAI catalogue. Click on the following link: /en/files/expansion/icai/catalog EPE. EDIBON Practical Exercise Program Package Main Screen ECAL. EDIBON Calculations Program Package Main Screen ERS. EDIBON Results & Statistics Program Package - Question Explanation * Specifications subject to change without previous notice, due to the convenience of improvement of the product. REPRESENTATIVE: C/ Del Agua, 14. Polígono Industrial San José de Valderas. 28918 LEGANÉS. (Madrid). ESPAÑA - SPAIN. Tel: 34-91-6199363 Fax: 34-91-6198647 E-mail: edibon@edibon.com Web: Edition: ED01/17 Date: November/2017 7