SF6-Analyzer GCTU-PDT-PTY-SO2 Gas Collection and Transfer Unit - with Pump-Back & Vacuum. AC Operated.

Similar documents
ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

Mix Boiler & Font Range ( #, #, #, , )

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

MIX Boiler & Font Range Service Manual

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Dew-Point Transmitters and Instruments

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Mercury Vapor Monitor VM-3000

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

DC200 Digital Dispenser Operating Manual

SHORT WAVE INFRARED PANEL DRYER

Tri-Tech Medical Inc.

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODEL Revision 9 th Mar Uber Boiler

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

PAC1500Xi PORTABLE APPLIANCE CHECKER

Please read this sheet as it contains important information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Ion Gateway Cellular Gateway and Wireless Sensors

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Room Sensor [RBT-3C] Installation Instructions

VM-3000 Mercury Vapor Monitor

IntelliDoX Operator Manual

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Oxygen & Carbon Dioxide Analyser. Model 1737 Operators Manual

Marco Beverage Systems Ltd.

Zircomat Oxygen Analyzers

Closomat Lima Vita installation & user guide

Focus 4010\ Focus 4010 HT porcelain firing furnace

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Refrigerated Incubator Model and Operating Instructions

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

PORTABLE DEW POINT MONITOR

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

incubator, the best in its class

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Oxygen & Carbon Dioxide Analyser. Model 1737 Operators Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

OPTISENS TUR 2000 Technical Datasheet

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

THX-DL Data Logger USER & INSTALLATION MANUAL V

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

Superdew 3. Hygrometer. Operating Instructions

Controller Specification Sheet

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

ph COOLING TOWER CONTROLLER

Parker icount Oil Sampler (IOS)

LC2200 Level Controller Installation and Maintenance Instructions

DIESEL Engine Fire Pump Controllers Features

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Accuracy by Design Products for the HVAC Professional

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

QIAcube HT Unpacking and Installation Instructions

Duct and Rough Service Carbon Monoxide Sensor

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Med Touch Combination Alarm Conversion Kits

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

DIESEL Engine Fire Pump Controllers Features

Installation and user manual

Chemistry diaphragm pumps

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

WHA 3000P Hot Air Station

Instruction Manual. B Issue B. next Pump Accessories

C-Bus Four Channel General Input Unit Installation Instructions

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

Original Instructions Instucciones originales Consignes originales. Model: AC R-1234yf A/C Recover, Recycle, Recharge Machine

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

S/601 Controller Installation Manual

ORP/MILLIVOLT CONTROLLER

Battery Powered Actuator with Watering Timer RBC MVA

Stability Chambers & Rooms

A new wave in automated instrument washing. Introducing the new HYDRIM G4 series

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Service Manual for RESmart CPAP V1.0. RESmart TM CPAP System. Service Manual

# TFB-S-120, TFB-L-120 TFB-S-220, TFB-L-220 FWS-S-120, FWS-L-120 FWS-S-220, FWS-L-220

Quick setup guide. English

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

RAM 50 Series Operation Manual

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

Transcription:

SF6-Analyzer GCTU-PDT-PTY-SO2 Gas Collection and Transfer Unit - with Pump-Back & Vacuum. AC Operated. User Manual English

Safety Information The SF6 Analyzer GCTU-PDT-PTY-SO2 is designed to be connected to AC/Mains electric voltages (110V). The SF6 Analyzer GCTU-PDT-PTY-SO2 must be earthed. Check to establish that all wiring and connections are not damaged. If damage is observed to any electrical wiring or damage to the apparatus they must not be connected to the AC/mains supply but returned to the supplier for rectification. Warnings Risk of electric shock - Do not open any part of the SF6 Analyzer GCTU-PDT-PTY-SO2 or any electrical apparatus whilst connected to the AC/mains supply. Ignoring this safety information could result in severe personal injury and/or mechanical damage to the SF6 Analyzer GCTU-PDT-PTY-SO2. Do not connect the SF6 Analyzer GCTU-PDT-PTY-SO2 or any electrical apparatus to the AC/mains supply until they are in their permanent positions ready for sampling. The product specifications must not be exceeded at anytime as this may cause damage to the instrument or cause risk of damage or fire. Do not connect the SF6 Analyzer GCTU-PDT-PTY-SO2 to any other device that is not recommended in this manual. If in any doubt - contact Delta Instrument LLC Tel: NJ 201-768-7200 Ensure that the SF6 Analyzer GCTU-PDT-PTY-SO2 does not come into direct contact with water or any other fluids or liquids. Avoid direct sunlight. To avoid the risk of electric shock, risk of damage or fire, these safety instructions and guidelines must be followed. Only qualified personnel/technicians should install this instrument to the AC/mains supply and ensure it is safe before use. Safe Isolation Switch off at the AC/mains socket and remove the plugs before any maintenance is carried out by a qualified person. Always test components with an approved voltage meter before handling to ensure it is completely dead. CERTIFICATE No. FM35600 BS EN ISO 9001: 2015

SF6-Analyzer GCTU-PDT-PTY-SO2 Gas Collection and Transfer Unit - with Pump-Back & Vacuum. AC Operated. Document Reference: 2413 - Issue 2 18/04/2018 User Manual This is a step by step instruction manual to help you successfully set up and operate the SF6 Analyzer GCTU-PDT-PTY-SO2 correctly before use. This manual should be kept with the SF6 Analyzer GCTU-PDT-PTY-SO2 for future reference. Please read this manual carefully from the start. CAUTION: The SF6 Analyzer GCTU-PDT-PTY-SO2 is a fragile instrument and great care must be taken not to drop, impact or shock the instrument, doing so could severly damage the electronics and/or other components, particularly when transporting the unit. Alpha Moisture Systems Ltd.

Index Introducing your new SF6 Analyzer GCTU-PDT-PTY-SO2 5 Functions and Features - SF6 Analyzer - GCTU-PDT-PTY-SO2 6 The SF6 Analyzer GCTU-PDT-PTY-SO2 Control Panel 7 QUICK START GUIDE 8-9 General Information 10 Control Display Screens - Navigation and Functions 11-14 Contact Information 15 4

Introducing your new SF6 Analyzer GCTU-PDT-PTY-SO2 Thank you for purchasing the Alpha Moisture Systems SF6 Analyzer GCTU-PDT-PTY-SO2. We are sure that after using this instrument you will agree that the SF6 Analyzer GCTU-PDT- PTY-SO2 is quick and easy to use. The instrument has many functions and features specifically designed with the operator in mind to fully optimize the instrument to specific applications. The instrument is pre-factory set and calibrated to take standard measurements straight away. The SF6 Analyzer GCTU-PDT-PTY-SO2 has been developed to meet worldwide regulations on green house gas emissions, especially SF 6 and other flourine gases. These damaging gases have global warming potential (GWP) to the environment which is why your SF6 Analyzer GCTU- PDT-PTY-SO2 has the most reliable quality components installed for safety and reliability. The whole purpose of this popular SF6 Analyzer GCTU-PDT-PTY-SO2 instrument, is to allow the user to accurately and quickly measure moisture content (dewpoint), purity and SO2 levels in SF6, and return the entire SF6 sample back to source, quickly and secularly with zero effect to the installation, and without releasing the gas to atmosphere. This is achieved by a very simple procedure, and with the help of the internal pump-back system integrated within the SF6 Analyzer GCTU-PDT-PTY-SO2. As we work hard to maintain and increase our excellent global reputation for Quality and Customer Services through really listening to our customers, we would welcome any feedback or comments you may have, however small, at this address please: info@amsystems.co.uk. Thank you once again for purchasing the SF6 Analyzer GCTU-PDT-PTY-SO2. Best Regards The Alpha Moisture Systems Team Protect the Environment - Never release SF6 to atmosphere. 5

Functions and Features - SF6 Analyzer - GCTU-PDT-PTY-SO2 High Quality Dewpoint Transmitter: Model PDT 4-20mA transmitter. Measuring Range: -76 to +68 F (-60 to +20 C) Dewpoint. Accuracy: ± 3.6 F (2 C) Dewpoint. Fast Response. Calibrated to International Standards SF6 Purity Analyzer (%): Sensor Type: NDIR. Range: 0-100%. Accuracy: ± 0.5%. Displayed: Color Touch Screen LCD. Factory alarm pre-set for MV and HV installations. SO2 Sensor Analyzer (ppmv): Sensor Type: Electrochemical Gas Sensor 4-20mA. Range: 0-100ppmv. Connections, Pressure and Flow: Swagelok QC4 male self-sealing process connectors, (maximum process pressure 12 barg), Process pressure indicator, sample flow regulator (sample flow controllable between 0.1 and 0.9 l/min), Sample flow indicator. Auto sample shut off when collection vessel is full. Vent for Vacuum. Transfer (Pump-Back) and Vacuum System: Quality hard wearing oil-less discharge pump. No oil residue emissions. (Maximum discharge pressure 175 p.s.i.g. (12 BARG) Power supply: AC input: 110 VAC - 50/60Hz. Accessories included: 2 metres of quality PTFE lined stainless steel braided connection hose with ¼ Swagelok self sealing quick mating connector. USB to USB cable for logging download. PC/Laptop logging software. AC/Mains cable. Dimensions: 24.6 x 19.7 x 11.6 (625 x 500 x 297mm) Weight: 49.5lb (22-5kg) Features Transportation Case Robust and toughest protective case in the industry. Fully integrated protection system. Quality easy press/pull latches and easy open hinge. Hard wearing, comfortable and soft non-slip grip handles side and top. Waterproof with full foam lid seal IP rating 67. Tough high quality urethane wheels. Pressure vents for air transportation. Retractable soft non-slip grip pull along handle (as pictured). 6

The SF6 Analyzer GCTU-PDT-PTY-SO2 Control Panel USB to USB PC Connection for Logging Color Touch Control and Display Screens Sample Flow Control Valve SF6 INLET FAST CONNECT Safety Fuses 2A and 10A AC Isolation On/Off Switch 110V AC Power Connection Vent Vacuum Inlet Fast Connect UPPER SCREEN Real Time and Date Real time logging Dewpoint in F, C or ppmv Note: Alarm set points will show in C - Default Dewpoint is F as shown here. SF6 Purity in % LOWER SCREEN Test Start and Stop and Test Complete Set Vacuum time Switch between High Voltage (HV) & Medium Voltage (MV). Quick-Start Instructions SO2 display in ppmv Touch to change to SF6 or N2 Flow rate display in litres per minute Discharge Start and Stop, and Discharge complete Vacuum Start and Stop, and Vacuum complete Input Pressure from pressure regulator in PSI 7

Quick Start Guide Ensure that the GCTU-PDT-PTY-SO2 is situated on a flat, level and secure surface before connecting up. Locate the nearest AC/mains power point. NOTE: If purging with other dry gases, such as nitrogen, prior to SF6 sampling - follow the same steps below. 1. Connect the GCTU-PDT-PTY-SO2 to the AC/Mains and switch on. 2. Ensure that the Sample Flow Control Valve is turned off (Fully Counter-Clockwise). 3. With a sealed connection/fitting already attached to the end of the sample line, to be connected later to the installation after the Vacuum procedure is completed, connect the other end of the sample line (with the Swagelok fitting) to the Vacuum Inlet on the GCTU-PDT-PTY-SO2 and press Vac (Vacuum) on the touch screen display. Do not connect the sample line to the installation at this stage. Note: The GCTU-PDT-PTY-SO2 is pre-factory set to vacuum for 1 minute. Press Vac Time prior to Vacuum to increase/decrease the Vac time using the + or buttons, then press save to load the new time value. 4. After the Vac is completed, disconnect from the Vac connection inlet and connect to the the SF6 Inlet Fast Connect (Gas Source). Connect to the installation under test (Switchgear for example), ensure gas tight ready for sampling. 5. Select Test on the lower screen and slowly open the Sample Flow Control Valve (Clockwise) until the flow reaches 0.8 Litres per minute (lpm). Ensure the flow states SF6. If purging with nitrogen press the flow reading to change the flow to N2. Note: The SO2 test will automatically run first for 1 minute, if successful, the rest of the test will then continue. If unsuccessful, a message will be seen on the lower screen, a Discharge (Pump- Back) will need to be performed before a re-test, this will reset the GCTU-PDT-PTY- SO2. 8

Quick Start Guide - Continued SF6 Analyzer GCTU-PDT-PTY-SO2 6. Allow the display to stabilize before taking readings. 7. Press the LOG button (upper screen) to record 1 minute blocks of readings (optional). After Sampling Procedure 1. When final readings have been obtained and Stop is selected, or when the internal vessel is full, the final readings will be displayed. Select Discharge in the lower screen to return the sample. 2. When all sampling is complete, shut off the Sample Flow Control Valve by turning Fully Counter-Clockwise until light resistance is felt. Do not over tighten. 3. Power down the unit. 4. Isolate and disconnect the gas source first (Switchgear for example) before removing the gas source from the GCTU-PDT-PTY-SO2 connection. To unlock the Gas Source connector push down firmly on the collar carefully separate the two halves of the connector. 5. Disconnect the power at the AC/Mains Power point first, then at the GCTU-PDT-PTY-SO2. 9

General Information The SF6 Analyzer GCTU-PDT-PTY-SO2 is a 110V AC operated unit. It is a fully self contained unit incorporating a Dewpoint Transmitter, SF6 Purity and SO2 analyzer, integral collection vessel (up to 15 litres capacity) and powerful pump (up to 175 p.s.i.g /12barg back pressure) for Vacuum and Pump-Back functions. The SF6 Analyzer GCTU-PDT-PTY-SO2 is supplied pre-factory set and calibrated, and is ready for immediate use. It has been specifically designed for ease of operation and is a stand aloan instrument. Dewpoint Range of the SF6 Analyzer GCTU-PDT-PTY-SO2-76 F to +68 F Dewpoint (-60 C to +20 C Dewpoint) Instrument Part Number Definition: GCTU = Gas Collection and Transfer Unit PDT = Polymer Dewpoint Transmitter PTY = Purity Sensor (in %) SO2 = Sulphur-Dioxide Sensor (in ppmv) Logging Logging is via USB/USB to PC or Laptop. PC Software provided. 10

Control Display Screens - Navigation and Functions Below are displays of the screens and an explanation to each of their functions: 1. To see the logged data on a PC/Laptop follow this procedure - Install the logging software that came with the GCTU onto a PC or Laptop with Windows XP or above. Plug the USB cable into the USB port on the GCTU and plug also into the PC/Laptop where the software is installed. 2. 1. This display in the Upper Screen is displayed when the GCTU is first turned on. Note: AC power to the GCTU is not needed as the software will power the screen on the GCTU via the USB from the PC/Laptop. Start the software on the PC/Laptop, all logged data can now be seen in 1 minute logged blocks. 2. When the Test button is pressed in the Lower Touch Screen, this display will appear in the Upper Screen showing date/time, and five touch screen buttons: LOG, Instructions, HV/MV - (change alarm pre-sets) for High/Medium Voltage Installations). Dewpoint can be changed to F, C, ppm(v) or ppm(w), and flow can be set to SF6 or N2 if purging. Having taken note prior to logging of the time/date of the installation under test will help determine which logged block of data belongs to which installation if the user is making multiple installation tests. The logged data blocks can be saved as a CSV file onto the PC/Laptop hard drive. To delete permanently the logged data in the GCTU fixed memory, please refer to the instructions for the software that came with the GCTU. See next page on how to download logged data. The user will see in real time the output from the sensors: dewpoint, SF6 purity, SO2 (if fitted), and flow. Press LOG at any time after all readings have settled and are stable, this will now commence logging for 1 minute on the internal memory. Tip: Manually take note of the time/date and the installation under test to help when reviewing the data on a PC/Laptop. 11

Control Display Screens - Navigation and Functions - Continued Downloading Logged Data To download logged data:- 1 Open the Design Studio. 2 Connect the supplied USB lead to the unit. 3 When the computer recognises the unit use the top right menu button to see the drop down list. 4 Select Retrieve Device Logged Data 5 Follow the instructions, select the log file and download. You can chose to keep the data on the GCTU or clear it after download. Open the saved file with Word and save as a.csv file. This can then be opened in Excel and manipulated as required. Please note that the Project cannot be uploaded from the GCTU via the Studio. On-Board Manual The on-board manual is a quick guide - It gives basic information to get started, and will display like this below. Press the blue Home button to return to the main display screen. 12

Control Display Screens - Navigation and Functions - Continued 3. This touch screen button allows the user to switch between HV or MV. Note: Doing so will also change the preset alarm points. See also pre-set alarm points on page 12. Note: Alarm set points must be in o C. 5. The capacity of the internal vessel holds approx 15 litres and will give the user at least 10 minutes sampling time. When the vessel becomes full, sampling will automatically stop. To pump-back the sample to the installation, simply touch the blue Discharge button, the pump will be heard working. Full discharge takes about 5 minutes. The Discharge button will turn red until completed as the display example below. 4. 3. After a short boot-up after switch on, this display will appear. The user will control the Test Start/Stop, Discharge (Pump-Back) Start/Stop, Vacuum and Vacuum duration. Also displayed here is the Input Pressure. The discharge can be stopped at any time by touching the red discharge button. When discharge (pump-back) has been completed, the pump will stop and the Discharge Complete message displayed, shown here. 4. When you see this message, re-check that both connections are fitted properly. 5. 13

6. Whilst still connected to the installation, if the user wishes to re-take the sample, touching the Test button again will start the process. SF6 Analyzer GCTU-PDT-PTY-SO2 Control Display Screens - Navigation and Functions - Continued 7. Note: Alarm set points must be in o C. The alarm set-points can be changed in this display by pressing the + / - buttons and saving the new setting by pressing the green tick button Save Alarms When the new settings have been saved successfully the Alarms Saved message will appear, as shown above. 6. Alarm Set Points - This instrument has been factory pre-set to visually alarm in accordance with IEC 60480:2004 for dewpoint, purity and SO2 for both HV, and MV. Alarm points High Voltage (HV) Installations: Dewpoint: -32.8 F (-36 C) or 198ppmv Purity: 97% SO2: MAX 50ppmv Alarm points Medium Voltage (MV) Installations: Dewpoint: -9.4 F (-23 C) or 762ppmv Purity: 97% SO2: MAX 50ppmv When an alarm set point has been reached or exceeded, the digits for that measurement will turn red as the above examples. 7. The Vacuum timer can be changed in this display by pressing the + / - buttons and saving the new setting by pressing the green tick button Save Vac Time When the new settings have been saved successfully the Vac Time Saved message will appear, as shown above. 14

Contact Information SF6 Analyzer GCTU-PDT-PTY-SO2 Head Office: Alpha Moisture Systems Alpha House 96 City Road Bradford West Yorkshire BD8 8ES United Kingdom Tel: +44 (0) 1274 733100 Fax: +44 (0) 1274 733200 Email: info@amsystems.co.uk Web: www.amsystems.co.uk Office Opening Hours: Monday - Thursday 8.30am - 5.30pm GMT Friday 8.30am - 5.00pm Saturday and Sunday - Closed Authorized distributor throughout USA and Canada: www.deltainstrument.com Tel: New Jersey 201-768-7200 or 866-628-8457 Toll Free Fax New Jersey: 201-768-5020 Corporate Office: 148 Veterans Drive, Northvale, NJ 07647 Stoney Creek, Ontario, Canada (Sales Office) Telephone: 905-643-3500 Notes: 15