PTE0705 Electric Fence Monitor

Similar documents
Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

ZLM4 OEM Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

ZM1 User Manual JVA TECHNOLOGIES.

ZM20 OEM Technical Manual

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

General Purpose IO Technical Manual

Ethernet General Purpose

USER MANUAL FOR OPERATING SYSTEM

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Carbon Monoxide Transmitter

Added password for IP setup page : Password must be in IP format!

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Door Release Power Supply

21-light Remote Annunciator. Owner s Manual

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

OWNER S OPERATION MANUAL

Installation, Operating and Maintenance Manual

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

CLEANROOM MONITOR CR3A Network - Installation Instructions

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Installation Manual Tracker 221

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

ACCURATE ELECTRONICS INC

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

02/11/2015

HRX Technical Manual. Version 1.2

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

20 Light Remote Annunciator

Beacon 800 Gas Monitor Operator s Manual

Water Detection Controllers

Ax60+ Multi-Gas. Service Manual

Introduction. OM-THA2

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

02/11/2015

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

products and services

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Application, Installation, Operation & Maintenance Manual

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

P2267 NETWORK INTERFACE

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Beacon 110 Gas Monitor Operator s Manual

Pump-Down Controller MODEL 4052

Across-the-Line SERIES MP300 Combined Manual and Automatic

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

Soft Start Series MP700 Solid State, Reduced Voltage

Superdew 3. Hygrometer. Operating Instructions

HRX3000. Technical Manual

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

Pioneer-R16 Gas Monitor Operator s Manual

Pump-Up Controller MODEL 4062

Public Safety DAS Annunciator Panel

Danfoss gas detection units

Dryer Controller M720

Installation Manual RINS1211-4

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

INTRODUCTION / TABLE OF CONTENTS

Series Temperature Controller Instruction Sheet

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

M2500 Engine Controller Installation Manual

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

IF-L/RF Protection Switch

Temperature Controllers

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

MO n : 12JMC rév A

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

M1000 Alarm Annunciator

DMFPM-2R MULTIFUNCTIONAL

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Operating Instructions

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

System 9000TS Sequence of Events Recorder

SMARTWALK DEMENTIA WANDERING SYSTEM

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

DGS - Danfoss Gas Sensor Check / Calibration Procedure

User Manual. Dryer Controller M720

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

REPEATER FS5200R INSTRUCTION MANUAL

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

REC-8R Environmental Control. Operation and Installation Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

User manual. KNXpar. version

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Instruction Manual Model Backup Switch, 1 for 8

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Transcription:

PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies.

TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS... 4 SPECIFICATIONS... 6 INSTALLATION... 7 INSTALLATION... 7 OUTPUT CONNECTIONS... 7 ELECTRIC FENCE MONITOR OUTPUTS... 8 LED DISPLAY... 8 RELAY OUTPUT... 8 STAND ALONE OPERATION... 9 CONNECTION TO AN ALARM PANEL... 9 LOW FENCE VOLTAGE SET POINT AUTOMATIC SETTING... 10 LOW FENCE VOLTAGE SET POINT MANUAL SETTING... 10 DELAY SETTING AND LATCHING... 10 0-10V ANALOGUE OUTPUT... 11 RS232 OUTPUT... 11 SDI-12 OUTPUT... 12 WARRANTY... 13 1

DESCRIPTION The PTE0705 Electric Fence Monitor is designed to allow the voltage on an electric fence to be monitored for the purpose of integration with other systems. It can be thought of as a transducer taking electric fence pulse voltage on the input terminals and delivering the peak voltage readings in a number of different formats. It may be installed near the energiser or at any point along the fence line. The PTE0705 replaces all of the models in the PTE700 V2 series: PTE0700, PTE701, PTE702 and PTE703. It combines most of the features of these four units into a single, highly integrated device. The PTE0705 may be connected to other systems via: Form C dry contacts (Relay output) 0-10V analogue output RS232 data SDI-12 protocol (not available yet) The PTE0705 is compatible with modern low impedance electric fence energisers that conform to IEC60335.2.76 standards. It can measure pulse voltages of up to 10kV peak. The PTE0705 draws only a few ma from any 10-24V DC supply making it suitable for Solar powered systems. This manual applies to Firmware Version 3.00 and PCB version 3.1 and higher. 2

QUICK START GUIDE Caution: Read the electric fence energiser manual and understand the risks associated before proceeding. This section gives the minimal information required to get the PTE0705 connected and running. 1. Turn the electric fence energiser off. 2. Remove the cover from the Monitor. 3. Wire the 12V and Gnd to a 10V to 14V power source, but leave the power off for now. 4. If you are going to use the Relay, RS232 or 0-10V outputs wire these up to your equipment now. 5. If you intend to look at the RS232 data configure your terminal program to 9600 baud, 8 data, 1 stop bit, no parity and no handshaking. 6. If you are using a USB to RS232 serial adaptor make sure you identify the correct COM port. 7. Wire the Fence and Ground binding posts (large Red and Green Terminals at the top of the product) to the live and ground wires on the fence. Or directly to the Fence and Earth terminals of the electric fence energiser. Use suitable insulated wire. 8. Check that fence wires are kept 25mm or more away from other equipment and any low voltage wiring. 9. Position the Delay pot to 12 O clock and the Voltage pot to 9 O clock. 10. Do not move the calibration trim pot. 11. Turn the electric fence energiser on. 12. Turn the 12V DC supply to the Monitor on. 13. The LEDs should all flash once and then start to light up with each energiser pulse. 14. Wait 30 seconds. 15. The monitor should not go into alarm (beeper off), the 0-10V output will show the fence voltage in /1000, the relay will be in the normal state and the RS232 data will read the fence kv. 16. After a few seconds turn the energiser off. 17. Wait about 30 seconds. 18. The monitor will go into alarm, the 0-10V output will go to 0V, the relay will change state and the RS232 data will show 0kV. 19. Turn the energiser back on and check the connected equipment is reading the data from the monitor. 3

FEATURES Monitors the peak pulse voltage from any electric fence (Note 1,2) Low Power Drain from 10 to 24 Vdc (12V nominal) Reverse polarity protection Relay contact outputs may be configured for normal or fail safe operation (J4) The relay may be mimic or latched (J3). ASCII RS232 data output stream shows fence voltage each pulse 0-10V Analogue output proportional to 0-10kV peak fence voltage with 4 pulse filtering Fence input rated to 10kV Contains opto isolation as required under IEC60335.2.76, CSA60335.2.76, AS/NZS60335.2.76 LED bar graph voltage display Low Fence Voltage alarm set point or automatic self-setting Adjustable calibration IP65 weather proof wall mountable enclosure Internal beeper for fence fail alert (can be silenced) Notes 1. Energiser must be above 0.2J rated output. 2. Energiser must be a pulse type, not a continuous AC. Continuous AC are rare but are still sold in the USA. EXPLANATION OF TERMS Low Fence Voltage Alarm set point is the fence voltage below which the Monitor will go into Alarm to show a failed fence. The PTE0705 Electric Fence Monitor allows you to manually adjust this set point, or alternatively it can be set to automatically adjust this set point. Please note, automatic is not operating at this time! When automatically adjusting, it also follows the fence s performance. If, for example, the fence were operating at 7kV when the Electric Fence Monitor is switched on, it would set its Low Fence Voltage Alarm set point at about 6kV. As days go by, grass might build up on the electric fence, lowering the voltage on the fence, or a dry spell might slowly increase the voltage on the fence. The Electric Fence Monitor sees the gradual change and adjusts its set point accordingly. If, however, the fence voltage drops more quickly the Electric Fence Monitor will raise an alarm. False alarms are less likely to be raised if the Electric Fence Monitor is allowed to automatically adjust its set point. Another advantage of using auto-adjustment is that the Monitor will also alarm on a quickly rising voltage. Note: the Low Voltage Set point and Delay settings are only important if you are using internal Beeper or the relay output. Delay from Low Fence Voltage to alarm is the adjustable amount of time the Monitor waits after the fence fails before it raises an alarm. For example, if the delay is set to six seconds, and the fence voltage goes low for only three seconds, no alarm is raised. The alarm would only be raised if the fence voltage stayed below the Low Fence Voltage Alarm set point for more than six seconds. 4

Raising the Alarm is when the Monitor changes the relay to the Alarm state, The Alarm LED lights permanently, and the Beeper sounds. The monitor will go into Alarm if the voltage measured between the Fence and Earth terminals goes below the Low Fence Voltage Alarm Set Point for longer than the Delay as set on the Delay pot. If you do not want the beeper to sound place the jumper on the two pins labelled /Beeper. Changing Relay to Alarm State. The relay is on or off. Which of these represents the Alarm state depends on whether J4 is linked (covered by a jumper) or not. If J4 is off the connection from NO to C will be closed on Alarm. This is discussed further on Page 8, under Relay Output. Optical (opto) isolation from fence inputs means that the fence inputs are not electrically connected to the rest of the circuitry. Instead, they are connected optically. This helps to protect any accessories connected to the Electric Fence Monitor and the Electric Fence Monitor itself from the high voltages on the fence. A electric fence lightning diverter can add further protection when connected between the fence and the monitor. RS232 output means that the data collected by the Electric Fence Monitor can be transmitted to other equipment in RS232 serial data format. You can easily use a computer to collect, save and display this information. The data is: 9600,8,n,1 format, No handshaking is required. 5

SPECIFICATIONS Specification Name Specification Supply voltage Supply current Min measurable input voltage Max measurable input voltage Acceptable Pulse period Input voltage measurement Relay output 10-24V DC 6mA (20mA with relay on) 0.3 kv 9.9 kv voltages over 9.9kV are shown as 9.9kV 1.0 to 3.0 seconds (0.33 to 1.0Hz) Peak of Voltage over 200uS from pulse start Dry changeover contacts 30V 1A (<500mA recommended) Energiser compatibility All pulse output type energisers with output over 0.2J Isolation from fence circuit Accuracy 0-10V output Accuracy RS232 output Operating temperature range 25kV (design target) ±5% after factory calibration on a 2J energiser ±5% after factory calibration on a 2J energiser -10 to +50 o C Table 1 Specifications Specifications are subject to change without notice. For the latest copy of this manual see www.jva-fence.com.au/downloads.php 6

INSTALLATION INSTALLATION Remove the 4 screws holding the top cover in place. Secure the PTE0705 to the wall or mounting device using the 4 mounting holes that will be hidden after the lid is replaced. Thread the 12-volt supply and any output leads into the Electric Fence Monitor enclosure through the cable gland on the side; tighten it to stop moisture or ants from entering. Attach a suitable insulated cable from the Electric Fence Monitor s red input binding post to the electric fence, and from the Electric Fence Monitor s green input binding post to a good earth connection. If possible connect to the same fence earth as the energiser is connected to. OUTPUT CONNECTIONS The Electric Fence Monitor s Power and Output connections are visible on the bottom edge of the circuit board and consist of a row of pluggable screw terminals. Figure 1 shows the screw terminals, adjustment trimmers and LED s. Voltage and Delay adjustments LEDs Output terminals along bottom edge of PCB. Figure 1 - Output Terminal Locations The cables shown should enter the enclosure of the Electric Fence Monitor through the cable gland on the side. The connections to the electric fence are not shown in Figure 1 those cables can be connected at the large Red and Green binding posts on the outside top of the Electric Fence Monitor s enclosure. 7

ELECTRIC FENCE MONITOR OUTPUTS LED DISPLAY The Electric Fence Monitor has Seven LEDs. Two Alarm LEDs and 5 Bar Graph LEDs. The Graph LEDs show the fence voltage in steps of 2kV live with each electric fence pulse detected. Green Over 8kV Green 6-8kV Green 4-6kV Red 2-4kV Red 0-2kV Red Alarm No Fence Pulse or low voltage. Flashes with a bad pulse, on permanently when the Monitor is in Alarm. Green Ok Flashes with each good pulse seen. RELAY OUTPUT The Electric Fence Monitor Relay has three terminals. These three terminals are: Common [C], Normally Closed [NC] and Normally Open [NO.] The relay will connect from C to NO when the fence fails (if J4 is off). These contact are may be connected to external alarm panels inputs, sirens or strobes. Terminal NC C NO Function Normally Closed Common Normally Open Table 2 Relay Connections NOTE: The relay contacts are rated at 30V, 1A (<500mA recommended). They MUST NOT be used to switch 240Vac. If you want to switch 240V you will need a 240V rated buffer relay with a 12V coil. You can switch the buffer relay coil from the Monitors relay. The Relay is can be configured to be fail safe by placing a jumper on J4. This means that the relay will be powered on until there is a fence fault. In the alarmed condition, the C and NC terminals are shorted. A fail safe relay will cause the monitor to consume slightly more power. 8

STAND ALONE OPERATION In Stand Alone Operation, the relay can be used to switch a siren or a strobe on when an alarm condition is raised. If both a siren and a strobe required they can be connected in parallel (provided the power supply or battery is big enough to power both). Battery or power pack. Figure 2 - Stand Alone Operation CONNECTION TO AN ALARM PANEL In Alarm Panel Operation, the relay outputs are connected to the alarm panel. See the documentation supplied with the Alarm Panel. Battery or power pack. Alarm Panel Figure 3 - Alarm Panel Operation 9

LOW FENCE VOLTAGE SET POINT AUTOMATIC SETTING Please note, automatic is not operating at this time! Turn the Volts trimmer fully anticlockwise Switch on the electric fence and ensure that it is operating in the expected range. Switch on the Electric Fence Monitor by supplying it with twelve volts. If the Electric Fence Monitor was already switched on, it may need to be reset by switching off (disconnecting the twelve volts supply) and switching back on. The Electric Fence Monitor has now automatically set the Low Fence Voltage Alarm Set Point and is now monitoring the Electric Fence. You can test its operation by deliberately placing a short on your electric fence the Electric Fence Monitor will raise an alarm. LOW FENCE VOLTAGE SET POINT MANUAL SETTING Remove the Jumper from J3 so that an alarm is not latched. Turn the Volts trimmer fully anticlockwise and then advance it clockwise slightly. If you do not advance the trimmer, the Electric Fence Monitor will think that it is set to automatically calibrate. Switch on the electric fence and ensure that it is operating in the expected range. Switch on the Electric Fence Monitor by supplying it with twelve volts. The Green OK LED should be flashing, indicating a working fence. The Low Fence Voltage Alarm Set Point is very low at present, because the Volts trimmer is turned almost completely anticlockwise. Gradually increase the set point by slowly turning the trimmer clockwise. The Low Fence Voltage Alarm Set Point is slowly increasing and will soon rise above your electric fence s voltage. When this happens, the Red Alarm LED will flash and after the delay set on the delay trimmer, the Alarm LED stay on, the beeper and relay will activate. The Low Fence Voltage Set Point is now about the same as your electric fence s voltage and needs to be lowered slightly. Do this by turning the Volts trimmer anticlockwise until the OK LED flashes again. DELAY SETTING AND LATCHING Switch off the electric fence OR place a short across the live to ground to remove the voltage at the monitor. Note the amount of time taken for the Electric Fence Monitor to raise an alarm. Turn the Delay trimmer anticlockwise to reduce the delay and clockwise to increase the delay. The shorter the delay is, the more likely the Electric Fence Monitor is to raise a false alarm, because every electric fence will have an occasional low voltage pulse. If Jumper J3 is on an alarm will be latched for the same Delay. This means the fence voltage must come good for the Delay time before an alarm will be cancelled. If Jumper J3 is off the alarm will be cancelled after 2 good electric fence pulses. This is mimic mode. 10

0-10V ANALOGUE OUTPUT The 0-10V Analogue Output is from terminals V and GND. The 0-10V analogue output voltage linearly represents the fence voltage ranging from 0-10kV, ie: Fence Voltage = (Analogue Output Voltage) x 1000 Note: The monitor has software filtering which is intended to give the average output over the last 4 pulses. The minimum time the Monitor must be powered before this output is valid is 3 seconds. If you are using the 0-10V output you can ignore J3, J4 and the Low Voltage and Delay settings. You may inhibit the internal Beeper by placing a Jumper over the /Beeper pins. RS232 OUTPUT The default mode is verbose with the output string as below: V 5500C R L F Where: 5500 is the measured peak voltage of the last fence pulse and C R is a carriage return and L F is a line feed. 8 characters inclusive of the C R L F The line will be repeated with each fence pulse detected. If the fence stops (no voltage) the output string will be sent after 2 seconds and each 2 seconds thereafter. V 0000C R L F Pin Tx Rx Gnd Function Transmit (link to Rx on your equipment) Receive Ground Table 3 PTE0700 RS232 Connections If you are using the RS232 output you can ignore J3, J4 and the Low Voltage and Delay settings. You may inhibit the internal Beeper by placing a Jumper over the /Beeper pins. If you require another format then please request it via email to sales@jva-fence.com.au 11

SDI-12 OUTPUT The SDI-12 Protocol is not available at the time of writing. Pin 12V Gnd Function 12V power in Ground (0V) Dat SDI-12 data line 0-5V Table 4 PTE0705 SDI-12 Connections If you are using the SDI-12 protocol you can ignore J3, J4 and the Low Voltage and Delay settings. You may inhibit the internal Beeper by placing a Jumper over the /Beeper pins. 12

WARRANTY The PTE0705 Electric Fence Remote Monitor Series is covered by a 12-month warranty against defective parts or workmanship. If you have any problems, return the Monitor along with your proof of purchase, or contact the store of purchase or distributor. For assistance If you have any operational problems, difficulties etc. you can phone or email your questions or comments to JVA: Phone (07) 0499 000 455 International +61 7 3888 3793 E-mail: sales@jva-fence.com.au Mailing address: PO Box 408 Narangba QLD 4504 Australia Street address: 1 Helium Street NARANGBA Qld 4504 Australia More help is available at the WEB site: www.jva-fence.com.au 13