T Mirror Cooling Specifications & Design Revision: -

Similar documents
OVEN INDUSTRIES, INC.

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

WaterFurnace FX10 Application Guide Reversible Chiller

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

I/A Series 716C 1/16 DIN Temperature Controller

ADDITIONAL INFORMATION

Water Tank and Heater

Analog Input Module IC670ALG630

RTD TEMPERATURE SENSING SYSTEM

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

CT398 Heaterstat TM Temperature Controller. Technical User Guide

SECTION BUILDING AUTOMATION SYSTEM

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657

RS485 MODBUS Module 8AI


Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Instruction Manual Model Backup Switch, 1 for 8

IF-L/RF Protection Switch

I/O ZONE 560/583 USERS GUIDE

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

B-40/B-41 Modulating Temperature Controller

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Substation Monitoring System

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

TC-9102 Applications

ESSEX ENGINEERING CORPORATION

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Pre-Cool and Free- Cool Fan Control

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

SLV CONTROLLER 105N46XX SERIES

Added password for IP setup page : Password must be in IP format!

ACCURATE ELECTRONICS INC

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

ECO N DATE DESCRIPTION OF CHANGE CHG

LineGuard 2300 Program User Manual (FloBoss 107)

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

02/11/2015

Temperature Controllers

TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies

02/11/2015

Substation Monitoring System

Temperature Data Logging

Sequence of operation

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

ELECTRONIC HUMIDISTAT: H270

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Installation Manual COPYRIGHT NOTICE

EasyLog Data Logger Series

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC

NEW LINE BOILER CONTROLLERS

- Essay Control Functions and Benefits

UDC100 Universal Digital Controller Specifications

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

QD-ENG-68 Controller for Thermoelectric Thermal Management

TEC Controller Heating & Cooling Heat Pump with Internal Reversing Valve & Mixed Air Control, Application 2072

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

AirTrak. Digital Control System. User Manual. Touchscreen Systems

General Routing Interface

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

QuadraTouch Pro Software Manual Dryer Control System

Installation and Maintenance Manual IM

Comparative analysis of power supply single speed air mover and an entire electronics enclosure system fan

DGC-500 DIGITAL GENSET CONTROLLER

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

PLC / HMI Modbus (Slave) Addressing

Dryer Master DM510 Commissioning Guide

UDC 700 Universal Digital Controllers and Indicator Specifications

MODEL NUMBER: SRCOOL60KCW

GEYSERWISE INSTRUCTION MANUAL

HLR 1000E Technical Specifications

Smart Thermostat. User Guide

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

HeatNet Manual Control Adjustment and Operation Instructions for Hydrotherm Firmware Version 2.8

Tasman Sea Control System

Sensaphone 400 Telemetry System Integration

Table of Contents SECTION PAGE

EasyLog Data Logger Series


Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Power & Instrumentation BU

3500/61E & 3500/67E Temperature Monitor

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Transcription:

. REV - DESCRIPTION Initial Release DATE 8/28/09 BY EAW T3-3151 Mirror Cooling Specifications & Design Revision: - FILENAME: T3-3151_Mirror Cooling Spec & Design.doc LAST SAVE: 12/14/2009 11:17 AM Page 1 of 7

TABLE OF CONTENTS 1 SUMMARY... 3 2 BACKGROUND... 3 3 REQUIREMENTS FOR NEW SYSTEM... 3 3.1 CONTROLLER REQUIREMENTS... 3 3.1.1 CONTROL ACTUATORS... 3 3.1.2 TEMPERATURE CONTROL... 3 3.1.3 TEMPERATURE SET POINT... 3 3.1.4 EXCHANGER ICING CONDITION... 3 3.1.5 MIRROR CONDENSATION PREVENTION... 3 3.2 ELECTRICAL REQUIREMENTS... 4 3.2.1 HEATER... 4 3.2.2 COOLING WATER FLOW ACTUATOR... 4 3.2.3 FAN... 4 3.2.4 AIR HANDLER TEMPERATURE SENSOR... 4 3.2.5 BOARD TEMPERATURE SENSOR... ERROR! BOOKMARK NOT DEFINED. 3.2.6 SPARE TEMPERATURE SENSOR... 4 3.2.7 DIFFERENTIAL PRESSURE SENSOR... 4 3.3 MECHANICAL REQUIREMENTS... 4 3.4 INTERFACE & COMMUNICATIONS REQUIREMENTS... 4 3.4.1 TCS3 INTERFACE... 4 3.4.2 DEW POINT TEMPERATURE SENSOR... 4 3.4.3 MIRROR TEMPERATURE SENSORS... 4 4 DESIGN... 5 4.1 OVERVIEW... 5 4.2 MAJOR COMPONENTS... 6 4.2.1 ETHERNET HUB... ERROR! BOOKMARK NOT DEFINED. 4.2.2 GALIL POCKET PLC... 6 4.2.3 RELAY BOARD AND TEMP FILTER... 6 4.3 CONTROLLER ALGORITHM... 6 TABLE OF FIGURES & REPORT TABLES FIGURE 1 MIRROR COOLING CONTROL SYSTEM BLOCK DIAGRAM... 5 Page 2 of 7

1 Summary This document lists the specifications and requirements for a new Mirror Cooling Controller and also includes the design and other information. This is not a major project, so much of the information can be conveniently placed in one document (excluding software). 2 Background Cold air is blown over the mirror during the day to cool it down before observing at night, when it is off to avoid air turbulence which affects seeing. The goal is to cool the mirror down to the outside air temperature. As of August 2009, the IRTF has a manual system for cooling the mirror it is turned on when the day crew arrives and off when they leave (Mon Fri). Just prior to this, it was a combination of manual and limited automation. This system was also powered on when the day crew arrived and then turned off when they left. However, it also had a controller that would simply blow cold air on the mirror and when it detected ice build up on the heat exchanger, it would stop cooling, turn on a heater for 30 minutes to melt the ice, and then resume cooling. The microcontroller on the Relay Board failed and it was decided to just make it completely manual since its operation was very close to being manual anyway and to then design a new Mirror Cooling Controller. Being able to automatically control the air and heater on weekends when nobody is up at the summit will be a requirement. Continuously blowing cold air bas been acceptable since there is not sufficient cooling capacity to lower the mirror temperature below the outside air temperature. However, in the future, the intention is to have sufficient cooling capacity to lower and control the mirror s temperature at a specified set point. Thus, a new controller will be required to accomplish this. 3 Requirements for New System 3.1 Controller Requirements 3.1.1 Control Actuators The control system shall control a fan to blow air on the mirror, a valve to control the cold glycol from the cooling system to the heat exchanger, and a heater to melt ice that collects on the heat exchanger from condensation. 3.1.2 Temperature Control The temperature of the mirror (average of the 6 mirror temperature sensors) shall be controlled to within +/- 1 deg C of the set point. Since the mirror cooling system only has the ability to cool, it is only required to control the mirror temperature if the set point is below dome air ambient temperature. 3.1.3 Temperature Set Point The control system shall accept temperature set points from -10C to 20C. NOTE: The input range can be large, but it just won t be used in practice. It also won t drive the design, so it can be anything really as long as it encompasses the actual temperature range that will be used. 3.1.4 Exchanger Icing Condition The control system shall detect and remove heat exchanger icing conditions. 3.1.5 Mirror Condensation Prevention The control system shall monitor the dew point temperature and cease cooling if the mirror temperature is less than??? deg C above the dew point temperature. Page 3 of 7

3.2 Electrical Requirements Since this is not a new design, many of the interfaces and components exist. 3.2.1 Heater The control system shall power two heaters that are each rated at 208 Vrms and 5.5 A (resistance measured at 38Ω). Total power will be about 2300 Watts (11 A @ 208 Vrms). 3.2.2 Cooling Water Flow Actuator The control system shall control a glycol flow actuator that has a nominal control voltage of 6-9 VDC which is directly proportional to valve stroke, i.e. 6 VDC (fully closed) to 9 VDC (fully open). The control signal input impedance is 10kΩ. 3.2.3 Fan The control system shall power a fan, via a contactor, used to blow air over the mirror. 3.2.4 Air Handler Out Temperature Sensor The controller shall monitor the outgoing air temperature from the air handler. The temperature sensor is a 10 kω (25 C) NTC thermistor. 3.2.5 Air Handler Out Temperature Sensor The controller shall monitor the incoming air temperature for the air handler. The temperature sensor is a 10 kω (25 C) NTC thermistor. 3.2.6 Glycol Temperature Sensor The controller shall monitor the glycol temperature. Sensor will be mounted to the glycol metal piping. The temperature sensor is a 10 kω (25 C) NTC thermistor. 3.2.7 Differential Pressure Sensor The controller shall monitor the differential pressure sensor. Its output is an on/off type switch which is normally open. 3.2.8 Fire Alarm Protection The fire alarm system has a normally closed switch output that is wired in series with one voltage leg of the motor contactor. 3.3 Mechanical Requirements There are no stringent mechanical requirements. Controller board must simply fit in a box mounted on the wall. 3.4 Interface & Communications Requirements 3.4.1 TCS3 Interface The control system shall be built around the TCS3 control system. The TCS3 system shall be the actual controller in the control system and other hardware essentially carries out its commands. Remote hardware shall interface to TCS3 via Ethernet and provide relevant telemetry and accept on/off commands. 3.4.2 Dew Point Temperature Sensor The control system shall query and receive dew point temperature data from the dew point temperature sensor via Ethernet. Describe model and equipment here. 3.4.3 Mirror Temperature Sensors The control system shall receive mirror temperature data from the mirror temperature sensors. The values are provided by the iqup system. The temperature sensors, known as TD1 thru 6, are archived in the iqup mysql database. Page 4 of 7

4 Design 4.1 Overview All of the sensors and actuators already exist and are in place for this design. In actuality, only the controller and interface is being designed as opposed to an entire control system. The design goal was to make this control system as simple as possible while not making it too dependent on other systems. Below is a block diagram illustrating the entire control system with new components highlighted in orange. Figure 1 Mirror Cooling Control System Block Diagram Page 5 of 7

4.2 Major Components 4.2.1 Galil Pocket PLC This device offers an assortment of I/O and other options suited for industrial applications, particularly: 6 PID controllers 8 analog inputs (+/- 10V, 12 bit ADC) 8 analog outputs (+/- 10V, 12 bit DAC) 16 optically isolated digital inputs 8 isolated digital outputs Ethernet connection The type and number of I/O offered meet the requirements for the control system and the PID controllers can be used if desired. This device is relatively inexpensive (~$345) and small (3.88 x 4.26 x 1.26 ). 4.2.2 Relay Board and Temp Filter As its name implies, the board will provide relays and buffers that can be activated to provide power to the fan, heater, and glycol valve. In addition, filtering for the thermistors will also be provided as well as AC to DC conversion to supply power to the Galil Pocket PLC. 4.3 Controller Algorithms (section is TBD) 4.3.1 Thermistor Temperature Conversion Thermistors are extremely nonlinear. However, their temperature vs. resistance curve can be accurately approximated by the Steinhart-Hart equation. Since computers are cheap and readily available, a somewhat complex equation is not an issue. Equations are copied directly out of a Mathcad sheet that derived them. The units should be ignored in the equations. The units are not entirely correct since Mathcad has issues with the natural log and units so some fudging of units occurred. Strip off the units (but keep exponents like k )and the answer will be in Kelvin. Equations could be arranged differently, but this is what Mathcad displayed by default. The equation to get the temperature (in Kelvin) for a given resistance is: Where: Page 6 of 7

R is equal to: Where: AD_div_V is the thermistor voltage measured by the AD. AD_source_V is the source voltage (about +9V) measured by the AD. R_divider_t is nominally 36.5 kω. thermistor_amp_gain is nominally (1 + 10kΩ/36.5 kω) = 1.274 4.3.2 Heater Cycle Page 7 of 7