RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

Similar documents
D285DH. Installation Instructions Photoelectric Duct Smoke Detector

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

RADION smoke RFSM-A. en Installation Guide

F220-B6PS/M. Installation Guide. Addressable Detector Bases

PHOTOELECTRONIC SMOKE DETECTOR

1161/1162 Residential Wireless Detectors

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

INSTALLATION AND OPERATION MANUAL

1161/1162 Residential Wireless Detectors

HomeLink Wireless Control System

FMR Installation Instructions. Addressable Fire System Controller

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

1126 Series Ceiling Mount PIR Motion Detector

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

D250A/D253/D261AW/D280A/D290 Series

PRODUCT DIAGRAM PACKAGE CONTENTS

1100X Wireless Receivers

Wireless DESCRIPTION. sentrol U L

Duct smoke housing, 2-wire D340/D340P

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

1125 PIR Motion Detector

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Installer Guide smart connect

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

D7044. Installation Instructions Multiplex Single Input Module

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

ESL 500N Series Smoke Detector Installation Sheet

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

DS160/161 Request To Exit PIR sensors Installation Instructions

User guide. for smoke detector

1164/1164NS WIRELESS SMOKE DETECTOR

D1255RB/D1256RB/D1257RB

PRODUCT DIAGRAM PACKAGE CONTENTS

1100D Wireless Receiver

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

D7052. Installation Instructions Multiplex Dual Input Module

SILENT KNIGHT. IntelliKnight Smoke Detector Cleaning and Testing Instruction. Equipment Needed. Testing Equipment. Cleaning Equipment

Wiring Instructions (01-09)

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

D7053. Installation Instructions Multiplex Input/Output Module

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Multiplex Eight Input Remote Modules

Badge Reader BR Installation Guidelines. Product Summary

Installer Guide smart connect

Addressable NAC Output Module D327A

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

Zigbee Smoke Sensor PSG03

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Model 17A00 Expansion Enclosure

Quick Touch Pendant User Guide

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

PAD100-6DB & PAD100-4DB PAD100-PD

Dear Tech-Man Subscriber:

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Honeywell Temperature & Humidity Sensor with LCD

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

7251DH Intelligent Air Duct Smoke Detector

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Wireless Installation Instructions BETA

RELEASE DEVICE CONTROLS

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

RADION. Transmitter. en Reference Guide

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

SIGA-CC1 Single Input Signal Module Installation Sheet

D720 and D1255 Command Centers

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

TrueAlarm Analog Sensing

TOTALPAC2 Integrated Fire Protection System

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

ESL 320A/350 Series. AC Powered Photoelectric Smoke Alarm Installation Instructions Description. Selecting a Location U L

FX-PDD Duct Smoke Detector Installation Sheet

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

RADION receiver SD B810 CHI. Reference Manual

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Motion Detector User Guide

INSTALLATION GUIDE XTLN-WIFI PANEL

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

Print Specification. Publication. Instructions. Specific requirements. General requirements

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

DS7465i. Installation Instructions. Input/Output Module

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Commercial Series TriTech Motion Detector. Reference Guide

Transcription:

RF80THS EN Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

RF80THS Installation Instructions Trademarks Trademarks Chamber Check is a registered trademark of Bosch Security Systems in the United States..0 Overview The RF80THS Smoke Detector is an open-area wireless smoke detector designed for use with commercial fire protective signaling and household fire warning systems. Refer to NFPA 7 and the Smoke and Fire Detectors Installation Considerations (P/N: 675). For commercial and industrial installations, allow spacing of 30 ft (9 m) between detectors. An Alarm and Test LED flashes approximately every 6 sec to verify the detector has battery power and the smoke sampling circuitry is functioning. The LED flashes every 0.5 sec in an alarm, allowing you to verify individual detector alarms. The detector automatically resets after 3 min if the alarm condition no longer exists. The detector can be manually reset by pressing the Test button. If there is an alarm after the Test button is pressed, the detector re-alarms in 0 to 30 sec. After the alarm condition clears, the control panel alarm can be cleared by a control panel reset command. Supervision is provided by transmitting a low power level signal to the receiver every 65 min if there is no other activity. All transmissions from the RF80THS send battery status information to the control panel. Figure : - Base locking tab - Lock-In feature. Break away to access. 3. Remove the detector from the mounting plate by twisting the base counterclockwise. 4. Install the mounting plate in the desired location, and do not attach the detector to the mounting plate at this time. 5. Install the two lithium batteries (Item in Figure ) in the detector s base and observe the polarity. These batteries are supplied in a separate package. Figure : Modifying the Lock-In Tab Installing the Batteries.0 Mounting The detector s maximum wireless range in open air is approximately 500 ft (50 m). In normal residential or commercial applications, keep the detector within 00 ft (30 m) of the control panel receiver it is assigned to. Temporarily mount the detector using double-sided tape, and test it from the desired location before permanently mounting it.. Remove the detector s dust cover. You can replace the dust cover during construction periods, but remove it when the alarm system is enabled.. The mounting plate has a base locking tab that, if used, requires you to press the locking tab towards the mounting surface to release the detector. If you do not want the Lock-In feature, do not make changes to the mounting plate. Use the Lock-In feature by modifying the base locking tab as shown in Figure. 6777087 6777087 - Lithium batteries () - Programming serial number 6. A two-part sticker on the detector s base (Item in Figure ) contains the nine-digit programming serial number. Remove one of the stickers and store it in a safe place. You need the number to program the detector from the control panel. 7. Connect the detector to the mounting plate and twist it clockwise.

RF80THS Installation Instructions 4.0 Testing 3.0 Programming Refer to your control panel wireless reference guide for programming information. 4.0 Testing 4. Operational Notify all concerned parties before and after performing maintenance or testing the fire alarm system. 4.3 Manual. Press and hold the Test button (Item in Figure 3).. Observe the Alarm and Test LED (Item in Figure 3). The detector can take up to sec to enter Test Mode. Figure 3: Sensitivity Testing Components. When the system is free of alarms, check each detector to ensure the red Alarm and Test LED flashes approximately every 6 sec. This verifies the detector is operating properly.. Test each detector to ensure it causes a control panel alarm. 3. Alarm the detector by doing one of the following: a. Press and hold the the Test button for 9 to sec. The LED lights, the sounder sounds, and a Test Report is sent to the control panel. b. Release the Test button to end the test. or Simulate an alarm following the instructions for an Underwriters Laboratories, Inc. (UL) Listed aerosol smoke detector tester, such as the Home Safeguard Industries 5S. 4. Sensitivity The detector s calibration is important in determining its continued operation. Depending on local regulations, the frequency of calibration testing might be required more often than once a year. According to NFPA 7, test calibration at installation, and every other year thereafter. Perform a Functional Test monthly. Test the detector s sensitivity by pressing the Test button and observing the Alarm and Test LED. 3 - Test button - Alarm and Test LED 3 - Cover latch If the detector is within the factory-marked calibration range, it goes into alarm and the LED steadily lights. If the detector is too sensitive, the LED rapidly flashes four times (once every 0.5 sec) and the detector goes into alarm with the LED steadily on. If the detector is not sensitive enough, the LED slowly flashes twice (once every sec) and the detector goes into alarm with the LED steadily on. If the detector is not operational, it does not signal an alarm. Return the unit for repair. 4.4 Visual Check The RF80THS includes the Chamber Check Automatic Trouble Indication. The detector uses this feature to automatically indicate when its calibration is out of the factory-listed range. Check the detector s sensitivity by visually inspecting it and observing the Alarm and Test LED s flash rate. Normally, the flash rate is once every 6 sec. When the detector is out of the sensitivity range, the LED quickly flashes twice every 6 sec to indicate low sensitivity. The LED quickly flashes twice every 3 sec for high sensitivity, indicating a dirty chamber. 3

RF80THS Installation Instructions 5.0 Thermistor Test 5.0 Thermistor Test Expose the thermistor to a heat source such as a hair dryer or a shielded heat lamp. Expose the thermistor until the detector goes into alarm and the Alarm and Test LED flashes every 0.5 sec. If the detector does not go into alarm, return it to Bosch for repair. Before proceeding to the next detector, clear each alarm for each test Figure 4: Removing the Detector Cover 6.0 Maintenance At least once a year, clean the detector s cover. Use a vacuum, clean and dry compressed air, or water. Pay particular attention to the screens. In dusty areas or areas of heavy insect concentration, cleaning might be required more often. To clean the detector:. Remove the detector from the mounting plate.. Insert a thin, flathead screwdriver into the cover latch and pry the cover away from the chassis (Figure 4). 3. Grasp the chamber cover and pull it up and away from the chassis (Figure 5). 4. With the chamber cover removed, clean the inside of the cover with a vacuum, clean and dry compressed air, or water. 5. Clean the inside of the chamber with a vacuum or clean and dry compressed air. Do not clean the chamber with water. - Cover latch - Chassis Figure 5: Removing the Chamber Cover 6. Replace the chamber cover by placing it parallel to the chamber and gently snapping the locking tabs into place. 7. Replace the detector s cover. 8. Connect the terminal strip and return the detector to its mounting plate. 9. Test the detector for proper calibration. 3 - Detector cover - Chamber cover 3 - Chassis Do not paint the detector. Paint or other foreign matter covering the screen can prohibit or retard smoke from entering the detector. 4

RF80THS Installation Instructions 7.0 Specifications 7.0 Specifications Table : Specifications Description Operating Temperature Supply Voltage Battery Life Recommended Battery Types Compatible Receivers Patents Compliance Wireless Photoelectric Smoke Detector with an integral +35 F (+57 C) heat sensor and an internal 85 db sounder +3 F to +00 F (0 C to +38 C); 0 to 95% relative humidity, non-condensing Approximately 6 VDC supplied by two 3 VDC lithium batteries Approximately 5 years under normal operating conditions with the recommended battery types Duracell DL3A Energizer EL3AP Panasonic CR3A RF34 RF3 RF3 RF33 The RF80THS is protected by one or more of the following: #5,400,04 #5,543,777 #D339,078 #DES,93,089 This device complies with Part 5 of the Federal Communications Commission (FCC) rules and the RSS-0 of Industry and Science Canada. Operation is subject to the following conditions: This device might not cause harmful interference, and This device must accept any interference received, including interference that might cause undesirable operation. Changes not expressly approved by Bosch can void the user s authority to operate this detector. 5

RF80THS Installation Instructions Notes Notes 6

RF80THS Installation Instructions Notes Notes 7

Bosch 30 Perinton Parkway Fairport, NY 4450-999 USA Customer Service: (800) 89-0096 Technical Support: (888) 886-689 004 Bosch 3666E