PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

Similar documents
ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E

TENDER NOTICE. Kolhapur Zilla Sahakari Dudh Utpadak Sangh Ltd. B-1, M.I.D.C., Gokul Shirgaon, Tal. Karveer, Dist. Kolhapur

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

Following are the systems proposed as per NBC & Local Fire Authority:

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

A. This section includes design and performance information for fire protection and suppression systems.

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SPRINKLERS TABLE OF CONTENTS

DIVISION 21 - FIRE SUPPRESSION

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

PROFESSIONAL SUPPLIER

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Specification/ Data Sheet

B. Related Sections: The following Sections contain requirements that relate to this Section.

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

DIVISION 21 - FIRE SUPPRESSION

SECTION SPRINKLER SYSTEMS

TR CASSETTE AC 1 NOS TR CASSETTE AC 1 NOS. Rate in words : TR HIGH WALL (3 star rated) 2 NOS.

TECHNICAL SPECIFICATION FOR FIRE DETECTION & ALARM SYSTEM INCLUDING FIRE EXTINGUISHERS

WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS

ADDITIONAL PRODUCTS 65

WET AUTOMATIC FIRE SPRINKLER SYSTEMS

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SECTION AUTOMATIC SPRINKLER PIPING

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

FIRE SUPPRESSION SPRINKLER SYSTEM

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

Discontinued Product

CENTRAL AIR CONDITIONER SPLIT SYSTEM

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Part # Page Dampers Supported Directly From Structure 5. Dampers Supported From Ductwork Above 4

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Fill Point, Level Gauges, and Control Range

3.1 Introduction. 3.1 Introduction

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

PART 1 - GENERAL SECTION FIRE PROTECTION BASIC MATERIALS AND METHODS

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Installation Instructions

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) PRICED BILL OF QUANTITIES

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

SECTION HYDRONIC PIPING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION WET-PIPE SPRINKLER SYSTEMS

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

Copyright 2013 Fike 12/13 SECTION CLEAN-AGENT FIRE-EXTINGUISHING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

2. Welding Materials and Procedures shall conform to the ASME Code.

CADDY CORPORATION. Utility Distribution Systems

The following information shall become and form part of the contract documents.

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

OPEN SPRINKLER SYSTEM

30.45 Electric Release PDRP-2001

Cater Hoses. Manufactured to BS669 PT2: /2 & 3/4 Braided Cater Hose with Lanyard - Quick Release

Accessories. Safety Shut-off Valves. Certifications. Accessories. ASV375NT Safety Shut-off Valve. Combination Gas Control/Valve

Flow Control for Fire Protection

SECTION METERS AND GAGES FOR HVAC PIPING

Flow Control for Fire Protection

Transcription:

ANNEXUREIII D: FIRE PROTECTION SYSTEM SECTION ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation, testing and commissioning of Analogue Addressable Fire Alarm Control panel with battery backup for 8 hours normal operation and 5 minutes alarm operation. Panel to have number of loops based on quantity of detectors mentioned in the respective item below. The control panel, battery charger etc. shall be UL listed. The panel shall be calculate below quantity of devices with adequate loop arrangements and with 5% capacity additional for future use. & The panel shall be consisting with 40 x 4 line character LCD display and 485 for networking. Cost shall be included for required control module & control relay modules (Location ground floor BMS Room ) NO Supply, installation, testing and commissioning of Repeater panel FOR Each floor and security cabin. Nos 0 3 Supply, installation, testing and commissioning of Analogue Addressable PhotoElectrical detector with programmable for timed automatic sensitivity selection with base, junction box and other accessories as required and detectors shall be UL listed.(osd) Nos 355

4 5 6 7 8 Supply, installation, testing and commissioning of Analogue Addressable Photo Thermal Multi Criteria Detector (PTMCD) with programmable for timed automatic sensitivity selection with base, junction box and other accessories as required and detectors shall be UL listed. Nos 5 Supply, installation, testing and commissioning of Response indicator for all detectors located above false ceiling 5 Supply, installation, testing and commissioning of Analogue Addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communication when shorted conditions are corrected. Supply, installation, testing and commissioning of Horn cum Strobe rated at 8 DBA @ 3m for Audible annunciation and 75cd flashing at Hz for visual indication. Supply, installation, testing and commissioning of Addressable Single action Manual pull station having an integrally mounted addressable moudle that monitors and reports contact status. Nos 90 Nos 50 Nos 50 ANNEXUREIII 9 Supply, installation, testing and commissioning of Addressable monitor Module Nos 0 0 Supply, installation, testing and commissioning of Addressable Control Relay Module 0

ANNEXUREIII Supply, laying & fixing of x.5 sq. mm, PVC insulated copper Cable confirming to IS standards and specifications.(below ceiling or in shafts/walls etc) Rmt 000 Supply, laying & fixing of x.5 sq. mm, PVC insulated copper wires confirming to IS standards and specifications. (Underground including excavation, back filing, proper manner sand & brick work as per standard electrical manner.) FOR SECURITY CABIN. Rmt 00 3 Supply, laying & fixing of perforated G.I. sheet cable tray with necessary angle iron suspension supports, anchor, fastners etc. complete. Maximum height of suspension shall not exceed 500mm size of the tray is a) 00mm x 50mm x 4SWG. Rmt 500 4 Supply, installation, testing & commissioning of photo electric integrated low flow duct detectors complete with mounting relays and housing. Nos 50 AUTOMATIC SPRINKLER SYSTEM (REPAIRING & REWORK) 3

ANNEXUREIII Supplying, installing, testing and commissioning of G.I. pipes confirming to IS 39 Pt I heavy grade with painting, suitable type of supports, (shall be hanger type for all size pipes which run below the slab & for wet risers C Channel to be used) with anchor fasteners, bolts nuts, clamps, "U" bolts shall be of malleable specials. Reducers, Tees, Elbows, flanges. Including cutting, welding, fixing in/ on walls, ceiling by using suitable supports etc. as per drawings. The quoted rate shall also include for chasing chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement mortar etc. complete. a) 65mm nominal dia Rmt 30 b) 50mm nominal dia Rmt 48 c) 40mm nominal dia Rmt 36 d) 3mm nominal dia Rmt 48 e) 5mm nominal dia Rmt 7 4

ANNEXUREIII Supplying, installing, testing and commissioning of G.I. pipes confirming to IS 39 Pt I heavy grade with painting, suitable type of supports, Reducers, Tees Elbows, flanges, including cutting, welding, as per drawings. The rate quoted should be included with anticorrosive treatment with 4mm polymer corrosion resistant tape as per IS 0, overlap shall be 5mm minimum, cement mortar etc. complete. a) 50mm nominal dia Rmt 6 b) 80mm nominal dia Rmt 6 3 Providing and fixing 5mm dia CP gunmetal / brass sprinkler head with temperature of operation 68 deg. C at working pressure of 75 psi, quartzoid bulb and set to operate at specified temperature. a) Pendant type Nos 0 b) Upright type Nos c) Pendant type 9 deg. C FOR PANTRY. Nos 6 4 Supplying, installing, testing and commissioning C.I Butterfly valves as per BS: 555 (PN0) slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. a) 50mm nominal dia Nos b) 00mm nominal dia Nos c) 80mm nominal dia Nos d) 65mm nominal dia Nos 5

ANNEXUREIII 5 Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves as per (PN0) with fitting of screwed end type. a) 50mm nominal dia Nos 6 b) 5mm nominal dia Nos 6 Providing and fixing electrically operated flow indicating switches with threaded connection for minimum flow of 900 Ipm for indicating water flow in sprinkler branch line on each floor with necessary junction box installed in accessible plate 00mm nominal dia Nos a) b) 80mm nominal dia Nos c) 65mm nominal dia Nos 7 Supplying and fixing approved make 5mm dia automatic air release valve with unions etc. complete. 8 UL Listed Sprinkler Flexible drop pipes made of Corrugated SS Tubing to with stand 6 Bar pressure with all support accessories with false ceiling framing work a) 000 mm long Nos 500 FIRE HYDRANT SYSTEM Supplying, erecting and commissioning of landing Hydrants comprising of the following in the fire duct. a) no. Stainless steel short branch pipe with nozzle. Nos 8 FIRE SUPPRESSION SYSTEM (FM 00] FOR UPS AND SERVER ROOMS Fire Fighting System for Server & UPS, Electrical rooms 6

Designing, supply, installation, testing & commissioning of CCOE certified 80 L capacity. Seamless cylinders with valve assembly & protection cap, pressure gauge, Safety burst disc and with low Nos pressure supervisory switch for FM00 gas installed on cylinder valve with Cylinder Pressure Operated Head with Hose & accessories, install on the Cylinder Valve cylinder support arrangements etc. complete.. Supply of OEM Factory Filled FM 00 Gas. kg 70 ANNEXUREIII 3 supply, installation, testing & commissioning of 4 VDC.0 amps, Resettable Electrical cum Mechanical actuator for FM 00 Cylinder with Cylinder Support Assembly, floor mounted, Flexible rubber discharge hose, with braided reinforcement Make: Kidde or equivalent Designing, supply, laying & fixing/ installation of the FM 00 piping will be, as per flow calculations, Sch 40, ASTM A06 Gr. B with seamless 4 3000 psi Socket weld fittings, Discharge nozzles, rigid angle supports, coats of zinc primer & 3 coats of P.O red paint. The equipments should be ISI Marked and Indian Seamless. Supply, Installation, Testing & Commissioning of Two zone gas release panel with all requisite mounting accessories and it should be able 5 integrate with other related and BMS System. The Panel should be Complete with Red Colour Housing, Power supply, required Battery charger & 30 min battery backup Supply, Installation, Testing & Commissioning of Manual Abort 6 Stations with DPDT Relay, The Abort will be monitored simultaneously by Fire Alarm System Supply, installation, testing & commissioning of Manual Release 7 Stations with DPDT Relay, The Release switch will be monitored simultaneously by Fire Alarm System. Job 4 7

Supply, installation, testing & commissioning of Sign Board with 8 Marking "Gas Discharge. Do Not Enter". Should Operate on 4 V DC, Driven Through Gas Release Panel / CM (for use outside room) 9 0 Supply, installation, testing & commissioning of Sign Board with Marking "Gas discharge Evacuate immediately". (for use inside room) Supply, installation, testing & commissioning of Cylinder Discharge Pressure Switch, Shall be installed on the FM 00 piping. ANNEXUREIII TESTING COMMISSIONING OF HYDRANT AND SPRINKLER SYSTEM Testing commissioning of existing hydrant and sprinkler system with necessary addition and alterations for the smooth functioning of the system complete including additional coat of paints where ever required as per engineerincharge's directions with necessary sign boards, floor plan indicators, warning boards, entry exit indicators, etc. complete. Providing warranty for the entire firefighting, fire detection and fire suppression system for a period of one year from the date of handing over the system with proper documentations. Job Job TOTAL 8