INSTALLATION, OPERATION

Similar documents
INSTALLATION, OPERATION

INSTALLATION, OPERATION

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

13-1. Temperature Regulator

Installation and Maintenance "L" and "LS" Series

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Advanced Solutions for Steam and Condensate Management

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

TITAN FLOW CONTROL, INC.

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Advanced Solutions for Steam and Condensate Management

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Model: 1100 Float-Controlled Condensate Trap, PN 25

THERMODYNAMIC STEAM TRAP

Why steam trap survey?

Disc Type Steam Trap TSD-42

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Radiator Trap Radiator Valve

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Liquid Drainers LIQUID DRAINERS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Noiseless Heater Vacuum Relief Valve

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

Series B Inverted Bucket Steam Traps

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Inverted Bucket Steam Traps

TECHNICAL DATA. Wet 26a. February 22, 2009

Pure Performance For Steam Mains and Tracers

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. QuickTrap FX1 Trap Unit X1. Manufacturer

Installation, Operation & Maintenance Instructions

THERMODYNAMIC STEAM TRAPS

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Series 1140 and 1141 Temperature Regulators

BK 45 BK 45-U BK 45-LT BK 46

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

LIQUIDATOR UMT-TD Series Thermodynamic

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

DRYAIRE DESICCANT SYSTEM MODEL 6760

Installation and Maintenance Manual

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

THERMODYNAMIC STEAM TRAPS

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

INSTRUCTION MANUAL UFO3-BN UFO3F-BN UFO3-CN FREE BALL-BUCKET STEAM TRAP UFO SERIES. Copyright (C) 2007 by TLV Co., Ltd. All rights reserved.

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Instructions for Installation, Operation, Care and Maintenance

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

mechanical. OPERATION Rapidrop Global

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS FS SERIES. QuickTrap FS3/FS5/FS5H.

Pure Performance For Steam Mains and Tracers

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Economical and simplified solutions that offer quality and optimum steam trap service.

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

CD-33/CD-33S Controlled Disc Steam Traps

! WARNING. Before using product, read and understand instructions.

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

THERMOSTATIC STEAM TRAPS

STEAM TRAPS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH7RH-B JH7.

Operation, Maintenance and Installation Manual

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

SuperKlean Washdown Products

SERVICE BULLETIN A

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Operating and installation instructions

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

INSTRUCTION AND REPAIR MANUAL

ESCO. Committed. Group of Companies. to help conserve Steam Energy

FT14 Ball Float Steam Trap (Screwed)

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Peerless Pump Company

AXPR Wall Mounted Axial Panel Fans

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

MFP14 Automatic pumps. for condensate and other industrial fluids

THE THERMOSTATIC STEAM TRAP

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS

! WARNING. Series 101-A Electric Water Feeder SPECIFICATIONS INSTRUCTION MANUAL MM-307H

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Transcription:

OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan

2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this manual thoroughly to understand the correct handling and operating procedure. The manual should be used by experienced personnel as a guide to the installation and maintenance of the Steam Traps. We ask you to contact MIYAWAKI or its local representative if further information is required. 1. Dimensions and Technical Specification Model SC-310 SC-311 SC-312 SC-314 SC-315 SF-310 SF-311 SF-312 SF-314 SF-315 Connection Screwed Rc, NPT Flanged ANSI, JIS,DIN Size mm (inch) 20 (3/4 ) 25 (1 ) 32 (1 ¼ ) 40 (1 ½ ) 50 (2 ) 20 (3/4 ) 25 (1 ) 32 (1 ¼ ) 40 (1 ½ ) 50 (2 ) Max. Oper. Pressure barg (psig) 16 (230) Max. Dimensions mm Oper. (inch) Temp. C ( F) L H1 H2 W 220 (428) 180 (7.1) 240 (9.5) 87 (3.5) 104 (4.1) 111 (4.4) 95 (2.0) 104 (4.1) 81 (3.2) 100 (3.9) 75 (3.0) 100 (3.9) 96 (3.8) 106 (4.2) 96 (3.8) 106 (4.2) Body Mater. Cast Iron FC 250 Weight kg (lb) 6,0 (13.2) 8,0 (17.6) 8,7 (19.1) 9,3 (20.5) 10,0 (22.0) 12,0 (26.4) 13,5 (29.7) 14,5 (31.9)

3 2. Installation CAUTION Before installing the trap, always blow down the piping that leads to the trap s inlet. A. Install the trap according to the direction of the arrow on the body. B. Install the trap at the lowest point of the steam using equipment to be drained. C. Install the trap so that the condensate will flow naturally into the trap. D. Thermodynamic steam traps can be installed either horizontally or vertically. E. The trap should be installed for easy maintenance. Due to the length of the strainer there should be space from the center of the inlet and outlet for maintenance purposes. 3. Trouble-shooting The steam trap should be checked for proper operation at least once a year. The thermodynamic steam trap is operating intermittently, i.e. it will open (discharge the condensate) and close at certain cycles. Problem The trap is not discharging. The trap is cold. The Trap is discharging continuously condensate. The trap doesn t close. The trap is blowing through or leaking steam. The disc is moving very quickly ( chattering ). Reason A. The inlet valve is closed. B. The strainer is plugged. Remove the Body Plug (No.8) and clean the strainer. C. The inlet orifice is plugged. D. The disc sticks to the seat due to oil or other dirt in the steam. E. The control chamber is filled with condensate, the disc is in closed position. It happens usually if the condensate is flowing back to the steam trap due to an incorrect installation of the condensate recovery line. F. Air locking - There is a lot of air inside the steam pipe. The air filles the control chamber and the disc sticks to the seat. A. The capacity of the trap is too low. A. Scale is lodged between the disc and the Disc seat. B. The disc and/or the disc seat are worn or damaged. C. The differential pressure is too low. The traps are designed to operate at a minimum differential pressure of 0,03 Mpa (4,35 psi). D. The trap may be oversized. E. The back pressure is too high (higher than 50% of the inlet pressure). F. The inlet pressure is higher than the maximum allowable operating pressure of the trap.

4 4. Maintenance, Disassembling and Assembling WARNING Before disassembling a steam trap be sure to close the valves in both supply and discharge lines, reduce the pressure inside the trap to atmospheric pressure, and allow the trap to cool before opening it. For cleaning purposes or for changing parts perform the following steps: A. Remove the Body Plug (8), take out the Screen (7), check and clean it. B. Remove the Cover (2). Then remove the Cap (3). C. You can take out the Disc (4). Firthermore the parts No. 5 (seat), No. 10 & 11 (gaskets), No. 6 (pin) and No. 15 (small pipe) can be taken out. D. Clean and check the parts. Replace any parts that are worn or damaged. If the seat or disc are worn, please, replace the complete inner unit. E. Assemble in the opposite way as disassembling. Don t forget to set the pin in the right place. Replace the gaskets by new ones. F. Tighten the cover bolts (No. 12) evenly. Wrench Sizes and Torques Type Parts Number Parts Name Wrench Size Torque SC-310,311 SF-340,341 12 Cover Bolts 22 mm 700 kgf cm SC-312,314,315 SF-342,344,345 12 Cover Bolts 24 mm 900 kgf cm SC-310,311 SF-340,341 8 Strainer Plug 35 mm 700 kgf cm SC-312,314,315 SF-342,344,345 8 Strainer Plug 40 mm 900 kgf cm

5 5. Details and Spare Parts List LIST MAIN SPARE PARTS No. Parts / Unit Name 4 Disc 11, 12 Gaskets 5 Seat

6 MIYAWAKI Inc. 2-1-30, Tagawakita Yodogawa-ku Osaka 532-0021 Japan Tel.: +81-6-6302-5549 Fax: +81-6-63025595 export@miyawaki.net www.miyawaki.net MIYAWAKI GmbH Birnbaumsmühle 65 15234 Frankfurt (Oder) Germany Tel.: +49-335-4144-201 Fax: +49-335-4000-122 info@miyawaki.de