T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.

Similar documents
LINE COMPONENTS VALVES

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Thermostatic Expansion Valves Type TR 6

Thermostatic expansion valves for ammonia Type TEA

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

General information on refrigerant controllers

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

Accumulators - Suction Line

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Emerson Superheat Control. The smart solution for your application

Filter Driers with Replaceable Core

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

Product Catalog VALVES

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

500 EX Fusion Compressor Series

REFRIGERATION PRODUCTS

Easy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017

REFRIGERANT CHANGEOVER

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Easy Find the right products fast with our Quick Selection Guide. Products and technologies for all your application needs, today and tomorrow

Chapter-8 Capacity Control of Refrigeration Systems

DESIGN STANDARDS SECTION 15600

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Thermostatic Expansion Valves

Bulletin , March Electric Hot Gas Bypass Valves

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Check valve Types NRV and NRVH

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications

64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions.

Energy Use in Refrigeration Systems

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

DDNCY (Temporary use)

ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application

10/4/2013. The Changing State of Refrigerants

49 Danfoss Thermostat Kits Ranco Varifix Kits

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

Dehydrators and Filters

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

Condensing Units CUS 15-60

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

.2 Section Waste Management and Disposal.

One. Save time and money Streamline your heat pump business! makes a difference.

PWM expansion valves 2028

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Sealed Type Liquid Line and Suction Line Specifications

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

Technical Information

PULSE WIDTH MODULATING VALVES

30GT FLOTRONIC AIR-COOLED CHILLERS

Suction Accumulators. Introduction. Suction Accumulators

DEHYDRATORS AND FILTERS

Copeland Scroll Condensing Units for the Food Service Market

Refrigeration Systems and Accessories

Air-Cooled Condensing Units with Compact Screw Compressors

30GN FLOTRONIC II AIR-COOLED CHILLERS

DANFOSS OPTYMA PLUS INVERTER UNITS

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

Commercial High-Efficiency Condensing Units

R-407A R-448A R-449A

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

LZT High efficiency air to water heat pumps with E.V.I. compressors

MACH N-407 Heat Pump Air-Cooled Chiller

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

These valves can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications.

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Research Design Quality Value Service Experience

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Refrigerant changeover guidelines

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Air-Cooled Condensing Units with Bitzer Compressors

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Pressure switch KPU. Data sheet

MODELS LIST. Nominal Capacity RT

Liebert CSU3000 Chiller

Optyma Slim Pack Condensing Units

Thermostatic Radiator Valves (Caleffi)

JCseries EVAPORATIVE CONDENSER. engineering data

Transcription:

DANFOSS THERMOSTATIC EXPANSION - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. FEATURES Large temperature range, suitable for freezing, refrigeration and air conditioning applications. Interchangeable oriice assembly MOP Valves (Max. Operating Pressure) availiable - protects the compressor motor against excessive evaporating pressure during normal operation. CONNECTIONS REFRIGERANT TEMPERATURE RANGE C EQUALISED BDA0020 068Z3206 TX2 R22/R407C INT TYPE IN. OUT. BDA0040 068Z3209 TEX2 R22/R407C BDA0060 068Z328 TX2S R22/R407C INT BDA0080 068Z3284 TEX2S R22/R407C BDA000 068Z3346 TN2 INT BDA020 068Z3348 TEN2 BDA040 068Z3383 TN2S INT BDA060 068Z3385 TEN2S BDA0200 068Z3400 TS2 INT BDA0220 068Z3403 TES2 BDA0240 068Z344 TS2S INT BDA0260 068Z345 TES2S BDA0280 068Z3408 TS2 MOP 50 (MOP50) -40 TO -5 INT (MOP50) -40 TO -5 BDA0300 09 068Z3409 TES2 MOP50

DANFOSS ORIFICE - T2 NOMINAL CAPACITY ORIFICE NUMBER R22 R404A BDA0320 068-2002 0X.0 0.9 0.7 0.6 0.7 0.6 BDA0340 068-2003 00.8.4.2 0.8.3 0.9 BDA0360 068-200 0 3.3 2..9. 2.4.4 BDA0380 068-205 02 4.2 2.5 2.2.3 3.2.7 BDA0400 068-2006 03 7.2 4.2 3.7 2. 5.5 2.9 BDA0420 068-2007 04 0.8 6.2 5.5 3.2 8.5 4.2 BDA0440 068-2008 05 4.6 8. 7.2 4..2 5.5 BDA0460 068-2009 06 7.0 9.4 8.6 4.9 3.4 6.6 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces low Decrease superheat - Anti-clockwise turn, increases low TX VALVE ISOLATION COVER Universal design, suitable for a range of brands Compact design suitable for internal and external balance Easy assembly Strong insulating properties Temperatures down to -45 C Ice blocking Stylish appearance BDA000 CFTXCOV Isolation Cover Tx Valve 0

DANFOSS THERMOSTATIC EXPANSION - TE5 TO TE55 The TE series expansion valve regulates the injection of refrigerant into evaporators. It controls the refrigerant low based on the superheat. The exchangeable power element is produced with Danfoss laser welding technology for extended lifetime capability. FEATURES Interchangeable oriice assembly. Stainless steel power element, capillary tube and bulb. Wide capacity range. Superior charge performance. Balanced oriice design on TE55 series. DANFOSS ELEMENTS - T5 REFRIGERANT BDA0480 067B3250 TEX5 R22/R407C BDA0500 067B3297 TEN5 BDA0520 067B3342 TES5 BDA0540 067B3358 TES5 MOP45 (MOP45) TEMPERATURE RANGE C EQUALISED TYPE -40 TO +0-40 TO -5 DANFOSS VALVE BODY - T5 CONNECTION DIRECTION BDA0560 067B4009 T5 Body ANGLE BDA0580 067B4007 T5 Body STRAIGHT TYPE IN. OUT. BDA0600 067B400 T5 Body ANGLE BDA0620 067B4008 T5 Body STRAIGHT BDA0640 067B403 T5 Body ANGLE BDA0660 067B40 T5 Body ANGLE BDA0680 067B4034 T5 Body ANGLE

DANFOSS ORIFICE - T5 NOMINAL CAPACITY ORIFICE NUMBER R22/R407C BDA0700 067B2788 0.5 9.9 6.7 6. 3.9 7.4 4.7 BDA0720 067B2789 0 8.2 2.3.2 7. 3.5 8.7 BDA0740 067B2790 02 25.4 7.3 5.7 0.0 8.9 2.2 BDA0760 067B279 03 32.0 2.6 9.9 2.7 23.8 5. BDA0780 067B2792 04 43.7 29.0 27. 7.0 32.5 20.4 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces low Decrease superheat - Anti-clockwise turn, increases low DANFOSS ELEMENTS - T2 REFRIGERANT BDA0800 067B320 TEX2 R22/R407C BDA0820 067B3232 TEN2 BDA0840 067B3347 TES2 TEMPERATURE RANGE C EQUALISED TYPE -40 TO +0 DANFOSS VALVE BODY - T2 CONNECTION BDA0860 067B4022 T2 Body ANGLE BDA0880 067B4020 T2 Body STRAIGHT BDA0900 067B402 T2 Body ANGLE BDA0920 067B4023 T2 Body STRAIGHT DIRECTION TYPE IN. OUT. DANFOSS ORIFICE - T2 NOMINAL CAPACITY ORIFICE NUMBER R22/R407C BDA0940 067B2708 05 43.7 33.9 33.3 2.3 42.6 25.3 BDA0960 067B2709 06 5.2 43.5 43.7 27.4 53.2 30.7 BDA0980 067B270 07 67.7 54.0 56.0 35.5 63.6 36.3 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces low Decrease superheat - Anti-clockwise turn, increases low 2

DANFOSS THERMOSTATIC EXPANSION - TUA/TUAE TUA/TUAE valves are made of stainless steel and can be used in many diferent forms of refrigeration systems, for example: Traditional refrigeration systems, heat pump systems, air conditioning units, refrigeration appliances, liquid coolers, ice cube machines, mobile refrigeration systems FEATURES Interchangeable oriice assembly designed for easy mounting and optimised tightness Bimetal connections - Simple, fast soldering without the need for wet cloth or refrigeration pliers. Stable regulation Bilow function (oriice to 8) Compact design - Small dimensions and low weight Stainless steel, solder version - High connection strength and tightness - Capillary tube joints of high strength and vibration resistance Laser-welded, stainless steel thermostatic diaphragm element - Optimum function - Long diaphragm life - High pressure resistance Stainless steel bulb - Simple and fast installation - Good heat transfer from pipe to bulb Interchangeable ilter for easy cleaning DANFOSS TUA TX CONNECTIONS BDB0020 068U2205 TUA REFRIGERANT TEMPERATURE RANGE C EQUALISED TYPE IN. OUT. INT BDB0040 068U2207 TUAE BDB0060 068U2285 TUA BDB0080 068U2287 TUAE INT NOMINAL CAPACITY ORIFICE NUMBER BDB000 068U030 0 0.5 0.3 0.4 0.3 BDB020 068U03 0.6 0.4 0.6 0.4 BDB040 068U032 2 0.9 0.5 0.8 0.5 BDB060 068U033 3.2 0.7.2 0.6 BDB080 068U034 4.8.0.7.0 BDB0200 068U035 5 2.4.3 2.3.3 BDB0220 068U036 6 3.6.9 3.4 2.0 BDB0240 068U037 7 4.9 2.6 4.6 2.6 BDB0260 068U038 8 7.3 3.9 6.8 4.0 BDB0280 068U039 9 0.8 5.7 0.2 5.8 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 4K Increase superheat - Clockwise turn, reduces low Decrease superheat - Anti-clockwise turn, increases low 3

EMERSON ELECTRONIC THERMOSTATIC EXPANSION - EX SERIES Emerson electrical control valves EX4, EX5, EX6, EX7 and EX8 are optimised for the control of liquid or gaseous mass low in refrigeration systems. The stepper motor, which produces a precise valve opening, is energised directly from the electrical power and therefore operates independent from diferential pressure ensuring stable operation at low condensing pressures. The valve seat and slider are made of solid ceramic for long life, low operating force, low internal leak rate and to eliminate corrosion. The positive shut of function and fast response time eliminates the need for an additional solenoid valve. The special shape of the valve slide provides for proper low through the valve and a highly linear capacity characteristic between 0% and 00% of maximum capacity. FEATURES Fully hermetic design Fast full stroke time Applicable to all common refrigerants (HCFC, HFC), for subcritical CO2 applications High resolution and excellent repeatability Bi-low versions for heat pump applications Positive shut-of function to eliminate the use of an additional solenoid valve Linear low capacity Wide capacity range (0-00%) Continuous modulation of mass low, no stress (liquid hammering) in the refrigeration circuit Direct coupling of motor and valve for high reliability (no gear mechanism) Ceramic slide and port for accurate low and minimal wear Balanced force design Corrosion resistant stainless steel body, and connections 5

EMERSON ELECTRONIC EXPANSION VALVE KITS CAPACITY RANGE kw BDC0020 EX4-U3KIT EX4-U3 Electronic Exp. Valve Kit BDC0040 EX5-U3KIT EX5-U3 Electronic Exp. Valve Kit BDC0060 EX6-I3KIT BDC0080 EX7-U3KIT INLET OUTLET R407C R22 R404A R40A R744 2-7 2-7 - 3-2 2-9 3-34 5-53 5-50 4-39 4-35 6-58 0-02 EX6-I3 Electronic Exp. Valve Kit 5-26 5-20 0-93 0-84 5-40 24-244 EX7-U32 Electronic Exp. Valve Kit 35-347 35-330 25-255 25-230 40-385 70-670 Kits include Bi-low valves with identical capacity in both low directions, electronic driver, transformer, NTC probe, transducer and connection kit. For capacity conditions, application examples or other technical data, please contact us. ELECTRONIC EXPANSION VALVE PARTS BDC000 EX4-U3 Alco EX4-U3 Electronic Exp. Valve BDC020 EX5-U3 Alco EX5-U3 Electronic Exp. Valve BDC040 EX6-I3 Alco EX6-I3 Electronic Exp. Valve BDC060 EX7-U3 Alco EX7-U32 Electronic Exp. Valve BDC080 TF20D 20VA Transformer To Suit EXV 230/24v BDC0200 XEV22D Dixell EXV Driver BDC0220 NT6-67 Dixell NTC 3m Probe Suit EXV BDC0240 PP Pressure Transducer -.5 - Bar EXV BDC0260 EXV-M5 Plug and lead.5m kit for EEV EX4-8 BDC0280 EXV-M30 Plug and lead 3.0m kit for EEV EX4-8 EXV-M30 XEV22D EX5-U3 Parts available in combined kit form. PP TRANSDUCER NT6-67 6

DENALINE ROTALOCK With 30 years of experience and over million valves manufactured each year, Denaline has the igures, know-how and technology you d expect from a true leader. Based in Italy, Denaline manufacture, quality-control and test their products in house, which are then distributed worldwide.they are a leading name in Europe and are recognised as such by virtue of their strong focus on quality, safety, technology and the environment. 7 BDD0020 39304R BDD0040 ROTALOCK PIPE ID Rotalock RL x Pipe 39307R Rotalock RL x Pipe BDD0060 39009R Rotalock RL x Pipe BDD0080 39007R Rotalock RL x Pipe BDD000 39008R Rotalock RL x Pipe BDD020 3907R Rotalock - RL x Pipe BDD040 3905R Rotalock - RL x Pipe BDD060 3908R Rotalock - RL x Pipe BDD080 43304R Rotalock - RL x Pipe BDD0200 43306R Rotalock - RL x -/8 Pipe BDD0220 45506R Rotalock - RL x Pipe BDD0240 45507R Rotalock - RL x -/8 Pipe BDD0260 45508R Rotalock - RL x - Pipe BDD0280 45505R Rotalock - RL x - Pipe BDD0300 6502R Rotalock 2- RL x - Pipe 2 BDD0320 6503R Rotalock 2- RL x 2-/8 Pipe 2 2 /8

DENALINE PRESSURE RELIEF Individually certiied, these Italian made pressure relief valves open gradually and reset quickly to minimise refrigerant loss in the event of an increase in pressure. CONNECTIONS BDE0020 DLD0/CS Pressure Relief Valve INLET NPT OUTLET PSI BAR kpa 435 30 3000 To meet increasingly demanding speciications, the Denaline dual shut-of valve allows the isolation of individual pressure relief valves for servicing and testing. CONNECTIONS BDE0040 7750S Three-Way Dual Shut-of Valve INLET NPT OUTLET 2 X RANCO 4 WAY REVERSING VALVE - 240V COIL & LEAD INCLUDED CONNECTIONS NOM KW (R22) NOM KW (R40A) DISCH. SUCT. MIN MAX MIN MAX TON BDF0020 V-2408064-2IL 2.6 7 3.2 7.7 2 BDF0040 V3-40084-7IL 3.5 9.8 4.2 0.9 3 BDF0060 V6-42084-IL 3.5 9.3 4.2 23.5 6 BDF0080 V6-44084-IL 3.5 9.3 4.2 23.5 6 BDF000 V0-44084-2IL 5.8 34.8 9.7 4.8 0 BDF020 V0-4424-2IL 5.8 34.8 9.7 4.8 0 BDF040 V0-4844-2IL 5.8 39.4 9.7 47.5 0 BDF060 V2-4220T4-2IL 2. 49.2 26.4 59. 2 * Capacity based on +7.2deg evaporating / 54.4deg condensing. Max capacity at 4kPa pressure drop. 8

RANCO REPLACEMENT COIL BDF0200 RANL30-42480 Reversing Valve Coil 240v BDF0220 RAN9220000 Reversing Valve Coil 24v SHUT OFF CAPPED LINE BDG0020 BDH0020 BDG0040 BDH0040 BDG0060 BDH0060 BDG0080 BDH0080 BDG000 BDH000 BDG020 BDH020 BDG040 BDH040 BDG060 BDH060 DANFOSS CHECK 9 TYPE BDI0020 020-040 Straightway BDI0040 020-04 Straightway BDI0060 020-042 Straightway BDI0080 020-043 Straightway BDI000 020-044 Angleway TYPE BDI020 020-00 Straightway BDI040 020-0 Straightway BDI060 020-02 Straightway BDI080 020-08 Straightway BDI0200 020-09 Angleway BDI0220 020-020 Angleway BDI0240 020-02 Angleway BDI0260 020-026 Angleway

EMERSON BALL - WITH ACCESS PORT The BVS Ball valve is a fully hermetic ball valve for the refrigeration and A/C industry. FEATURES Two threads at valve body for easy mounting Hermetic design Compatible with high pressure refrigerants such as R40A and CO2 (sub-critical) Light weight design Virgin PTFE seal gaskets Bi-directional low characteristics Valve cap retained by strap attached to main body Pressure relief port design full low design (minimal pressure drop) Access port with schrader core BDJ0020 BVS-04 BDJ0040 BVS-038 BDJ0060 BVS-02 BDJ0080 BVS-034 BDJ000 BVS-058 BDJ020 BVS-078 BDJ040 BVS-8 BDJ060 BVS-38 BDJ080 BVS-58 BDJ0200 BVS-28 2 /8 TECHNICAL DATA Maximum allowable pressure PS 45 bar Test pressure PT 49,5 bar Burst pressure 225 bar Medium temp. TS -40 20 C (50 C short term) Construction Forged brass body, copper extension tubes, chrome plated ball Medium compatibility * HFC, HCFC, CO2, mineral, synthetic and polyol-ester (POE) lubricants Material Body CW67N, copper tubes CW 024A acc. EN2420 * BVS Ball valves are not released for use with caustic, poisonous or lammable substances. 20

DANFOSS CRANKCASE PRESSURE REGULATORS Crankcase pressure regulator type KVL is itted in the suction line ahead of the compressor. KVL protects the compressor motor against overload during start-up after long standstill periods or after defrost periods (high pressure in evaporator). BDK0020 034L004 KVL2 BDK0040 034L0042 KVL5 BDK0060 034L0043 KVL2S BDK0080 034L0049 KVL5S BDK000 034L0045 KVL22S BDK020 034L0046 KVL28S BDK040 034L0052 KVL35S DANFOSS EVAPORATOR PRESSURE REGULATORS KVP evaporator pressure regulators are itted in the suction line of refrigeration and air conditioning systems. They are used to: Maintain a constant pressure equivalent to a constant temperature on the evaporator. Protect against a dangerously low evaporating pressure by throttling down when pressure falls below the set value. Diferentiate the evaporating pressures in two or more evaporators in systems with one compressor. 2 BDL0020 034L002 KVP2 BDL0040 034L0022 KVP5 BDL0060 034L0023 KVP2S BDL0080 034L0029 KVP5S BDL000 034L0025 KVP22S BDL020 034L0026 KVP28S BDL040 034L0032 KVP35S

DANFOSS SOLENOID Danfoss EVR valves are suitable for liquid, suction, and hot gas lines. They are compatible with a wide choice of coils for AC and DC and are designed for temperatures of up to 05 C. FUNCTION FUNCTION BDN0020 032F807 EVR3 BDN060 032F206 EVR3S BDN0040 032F86 EVR3 BDN080 032F204 EVR3S BDN0060 032F8072 EVR6 BDN0200 032F22 EVR6S BDN0080 032F8079 EVR6 BDN0220 032F209 EVR6S BDN000 032F8095 EVR0 BDN0240 032F27 EVR0S BDN020 032F8098 EVR0 BDN0260 032F24 EVR0S BDN040 032F80 EVR5 BDN0280 032F228 EVR5S BDN0300 032F225 EVR5S BDN0320 032F240 EVR20S BDN0340 032F220 EVR25S BDN0360 042H06 EVR32S BDN0380 042H2 EVR40S 2 /8 * Above solenoid valves do not include coils. Please see below. DANFOSS SOLENOID COILS CONNECTION TYPE VOLTS WATTS BDN0400 08F6702 IP67 Terminal Box 240AC 0 BDN0420 08F6252 With Lead 240AC 0 BDN0440 08F6730 IP67 Terminal Box 0AC 0 BDN0460 08F6706 IP67 Terminal Box 2AC 0 BDN0480 08F6707 IP67 Terminal Box 24AC 0 BDN0500 08F6856 IP67 Terminal Box 2DC 20 BDN0520 08F6857 IP67 Terminal Box 24DC 20 *To suit EVR solenoid valves 22

DRIERS DANFOSS LIQUID LINE FILTER DRIER DML Danfoss DML driers have a core composition of 00% Molecular Sieve making them ideal for applications requiring the highest moisture capacity. FEATURES High drying capacity minimising the risk of acid formation The drier shell has a powder coated corrosion resistant inish Sizes ranging from 3 75 cubic inches The ilter is thermally stable up to 20 C. DANFOSS LIQUID LINE FILTER DRIER DML - 23 BDO0020 023Z5035 DML032 BDO0040 023Z5036 BDO0060 LIQUID CAPACITY KW R22 R404A 7.45 6.7 5.0 DML033 4.46 2.85 9.86 023Z5037 DML052 8.45 7.67 5.62 BDO0080 023Z5038 DML053 4.44 2.87 9.8 BDO000 023Z5039 DML082 8.32 7.68 5.44 BDO020 023Z5040 DML083 6.03 4.9 0.98 BDO040 023Z504 DML084 3.76 28.6 2.33 BDO060 023Z5042 DML62 8.3 7.68 5.43 BDO080 023Z5043 DML63 7.4 6.33.8 BDO0200 023Z5044 DML64 35.4 32.9 23.54 BDO0220 023Z5045 DML65 5.82 44.64 36.59 BDO0240 023Z0049 DML303 6.59 5.7 0.56 BDO0260 023Z0050 DML304 36.63 32.5 25 BDO0280 023Z005 DML305 52.72 45.7 36.96 BDO0300 023Z093 DML306 53.22 43.73 39.89 BDO0320 023Z008 DML43 9.49 8.4 2.44 BDO0340 023Z009 DML44 38.5 33.39 26.45 BDO0360 023Z00 DML45 6.92 55.48 4.84

DRIERS DANFOSS LIQUID LINE FILTER DRIER DML - BDO0460 023Z5048 DML032S BDO0480 023Z5050 BDO0500 LIQUID CAPACITY kw R22 R404A 7.45 6.7 5.0 DML033S 4.46 2.85 9.86 023Z5053 DML052S 8.45 7.67 5.62 BDO0520 023Z5054 DML053S 4.44 2.87 9.8 BDO0540 023Z5057 DML082S 8.32 7.68 5.44 BDO0560 023Z5058 DML083S 6.03 4.9 0.98 BDO0580 023Z506 DML084S 3.76 28.6 2.33 BDO0600 023Z5063 DML62S 8.3 7.68 5.43 BDO0620 023Z5064 DML63S 7.4 6.33.8 BDO0640 023Z5067 DML64S 35.4 32.9 23.54 BDO0660 023Z5068 DML65S 5.82 44.64 36.59 BDO0680 023Z0067 DML303S 6.59 5.7 0.56 BDO0700 023Z0068 DML304S 36.63 32.5 25 BDO0720 023Z0069 DML305S 52.72 45.7 36.96 BDO0740 023Z0070 DML306S 53.22 43.73 39.89 BDO0760 023Z007 DML307S 75.4 64.25 53.95 BDO0780 023Z0 DML44S 38.5 33.39 26.45 BDO0800 023Z02 DML45S 6.92 55.48 4.84 BDO0820 023Z03 DML47S 78.5 66.74 56.32 BDO0840 023Z04 DML49S 09.42 95.3 76.29 ARI 70-2004: -5 c evaporating temp, 30 c condensing temperature and.07 bar 24

DRIERS DANFOSS BURN-OUT DRIER DAS Danfoss DAS burn-out driers are used in the suction line to clean up refrigeration and AC-systems with luorinated refrigerants after a compressor motor burn-out. The solid core is composed of 70% activated alumina and 30% molecular sieve which works to absorb harmful acids as well as moisture. By absorbing these acids, the DAS burn-out ilter drier protects the new compressor from premature failure. FEATURES 2 Schrader access valves to measure pressure drop across the drier Sizes ranging from 8 to 60 cubic inches, The drier shell has a powder coated corrosion resistant inish Allows installation in any position provided the low is in the arrow direction BDO0940 023Z009 DAS64S BDO0960 023Z008 BDO0980 RATED CAPACITY kw Qe R22 R404A 0.5 6 8.5 DAS65S 5 9.5 3 023Z02 DAS67S 22 3.5 9 BDO000 023Z03 DAS305S 8 5 BDO020 023Z04 DAS306S 22 4 9 BDO040 023Z05 DAS307S 26 6 22 BDO060 023Z06 DAS309S 3 20 27 Capacity is rated at 4 C evaporating temp,.2bar Capacities for other temperatures than 4 C are calculated by use of correction factors. Divide your actual evaporator capacity with the correction factor given for your actual evaporating temperature. Look up the capacity table for the necessary rated capacity. Qe/Fe = Qn Qe = Actual evaporator capacity Qn = Nominal capacity Fe = Correction factor Correction factors. Fe evaporating temperatures [ C] [ C] 4 0-5 -0-5 -20-25 -30-35 -40 Fe 0.9 0.75 0.6 0.5 0.4 0.35 0.25 0.2 0.5 Example To select a burn-out ilter drier for a plant with an evaporator capacity at 8.5 kw at -5 C you may use a burn-out ilter drier with a rated capacity of 8.5/0.75 =.33 kw or bigger. For example DAS 305. 25

DRIERS DANFOSS BI-FLOW DRIER DMB Bi-low ilter driers have built-in check valves which ensure that refrigerant liquid always lows through the ilter driers from the outer side of the ilter core towards the centre. Thus all dirt particles are retained irrespective of low direction. DMB ilter driers ensure fast and efective absorption of moisture as well as organic and inorganic acids. FEATURES High drying capacity minimising the risk of acid formation Seamless core blend for systems operating at high condensing temperatures and require high drying capacity No dirt released by reversing the low direction Sizes ranging from 8 30 cubic inches DANFOSS BI-FLOW DRIER DMB - BDO60 023Z42 DMB082 BDO80 023Z4 BDO200 LIQUID CAPACITY kw R22 R404A 4.3 3.9 2.8 DMB083 8.2 7.4 5.3 023Z40 DMB084 9.2 8.3 6 BDO220 023Z45 DMB63 20 8 3 BDO240 023Z44 DMB64 32 28 20 BDO260 023Z43 DMB65 40 37 29 DANFOSS BI-FLOW DRIER DMB - BDO280 023Z443 DMB082S BDO300 023Z442 BDO320 LIQUID CAPACITY kw R22 R404A 4.3 3.9 2.8 DMB083S 8.2 7.4 5.3 023Z44 DMB084S 9.2 8.3 6 BDO340 023Z446 DMB63S 20 8 3 BDO360 023Z445 DMB64S 32 28 20 BDO380 023Z444 DMB65S 40 37 29 BDO400 023Z447 DMB307S 47 43 32 ARI 70-2004: -5 c evaporating temp, 30 c condensing temperature and.07 bar. 26

DRIERS ESK FILTER DRIERS FEATURES Solid cores are easily replaceable Drier can be used alternatively as a ine strainer element after removal of solid core Schrader itting to measure pressure drop Steel connector ittings Epoxy coating for surface protection CORE BDO580 FTX- BDO600 FTX-22 BDO620 FTX-28 BDO640 FTX-35 BDO660 FTX-42 BDO680 FTX-54 2 /8 BDO700 FTX-2. 2 BDO720 FT2X-35 2 BDO740 FT2X-42 2 BDO760 FT2X-67 2 2 DRIER CORES SUITABILITY MATERIAL BDO2999 Suction Mesh Filter All refrigerants. Reuseable Stainless steel BDO3000 Core Standard General Clean Up All Round Clean-up (not recommended for POE oil) 80%MS, 20%AL BDO3020 Core Burn-Out Complete Clean Up Not recomended for long time use especially with POE 60%MS, 35%AL, 5%AC BDO3040 Core Ultra Drier HD Moisture Ideal for POE 00% MS MS = Molecular sieve AL = Activated Alumina AC = Activated Carbon 27

SIGHT GLASS DANFOSS MOISTURE INDICATOR - SIGHT GLASS SGN Sight glasses are used to indicate:. The condition of the refrigerant in the liquid line of the plant. 2. The low in the oil return line from the oil separator. 3. The moisture content in the refrigerant. The Danfoss SGN are equipped with sensitive indicators that relects a colour, depending on the moisture content in the refrigerant. FEATURES Indicates excess water content in the refrigeration system Indicates lack of subcooling DANFOSS MOISTURE INDICATOR - SIGHT GLASS - NO. BRAND BDP0020 04-06 SGN6 BDP0040 04-062 SGN0 BDP0060 04-063 SGN2 BDP0080 04-065 SGN6 BDP000 04-066 SGN9 DANFOSS MOISTURE INDICATOR - SIGHT GLASS - NO. BRAND BDP020 04-08 SGN6S BDP040 04-082 SGN0S BDP060 04-083 SGN2S BDP080 04-084 SGN6S BDP0200 04-085 SGN9S BDP0220 04-086 SGN22S DANFOSS MOISTURE INDICATOR - SIGHT GLASS - MALE/FEMALE NO. BRAND MALE/ BDP0240 04-07 SGN6 BDP0260 04-072 SGN0s BDP0280 04-073 SGN2 BDP0300 04-074 SGN6 BDP0320 04-075 SGN9 28

VIBRATION ELIMINATORS PACKLESS VIBRATION ELIMINATORS Vibration Eliminators can be installed in both suction and discharge line of air conditioning, heat pump and refrigeration systems. The function of a vibration eliminator is to absorb the vibrations caused by the compressor. 29 Ø D L (+/ 5) inch mm VAF3 250 BDQ0040 VAF4 270 BDQ0060 VAF5 290 BDQ0080 VAF6 270 BDQ000 VAF8 330 BDQ020 VAF9 370 BDQ040 VAF0 420 BDQ060 VAF 432 BDQ080 VAF82 2 /8 508 BDQ0200 VAF83 2 60 BDQ0020