DTS Light fittings for explosive atmospheres

Similar documents
PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

Illumination unit For sight glass level indicator Model LGI

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Dräger Polytron 5700 IR Detection of flammable gases and vapours

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5720 IR Toxic Gas Detection

Operating Instructions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Ex LED light fittings

Dräger Polytron 5720 IR Detection of carbon dioxide

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

Dräger Polytron 8720 IR Detection of carbon dioxide

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

XLFE-4/1. Borosilicate glass globe

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

High bay LED lighting fixture

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INTRINSICALLY SAFE LIGHTING RANGE

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

DB4 Range - SPEAKERS - Up to 25 Watts

Integrated Solutions Low Voltage Systems

Certification Supplement Manual

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

BC9700 series High Power LED Explosion Proof Light

Manual Power relay SR853

Dräger Polytron 5100 EC Detection of toxic gases and vapors

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

CCTV quick connect Harsh and Hazardous area connectors for camera stations

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION & SERVICE MANUAL

TPPL TUBULAR PROFESSIONAL PERFORMANCE LIGHTING SMART LIGHTING FOR HARSH ENVIRONMENTS

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Industrial & Hazardous Area Electrical Equipment

Helyum. Feam Product Brochure LOCATION CERTIFICATES REFERENCES. Milan / ITALY ATEX, IECEX, EX GOST, INMETRO, NEC500-5

Explosion-proof Immersion Heater Type D-8660

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

standards: standards:

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

CoreLine Batten the clear choice for LED

Flameproof Manual Call Points Series MCP

official distributor of Newson Gale Ltd.

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Electrical Installations Design, Selection, Erection and Inspection

ATM Lighting sp. z o.o

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Certificate of Compliance

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Floodlights. In this section.

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

ATM Lighting sp. z o.o

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Certification Supplement Manual

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

Certificate of Compliance

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Champ-Pak Wall Pack Luminares

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

UL HAZARDOUS LOCATIONS SERVICES

Hazardous Area Portable Fan Heater The Bulldog

HAZARDOUS AREA SOLUTIONS

Gas cylinder scale Model GCS-1

EVLPF Series Compact Fluorescent

Transcription:

DTS Light fittings for explosive atmospheres For all zones and industrial applications

LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light fittings XFFL Range - XFF Range - Fluorescent Tubular glass light fitting for Zones 1, 2, 21 & 22 All components mounted on sliding gear tray for easy installation and maintenance Available in glass for chemical environment and corrosive atmospheres Including accessories (cable gland, plug & fixing brackets) Supplied with offshore grade paint II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C XFP Range - Fluorescent with automatic switch off II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 100-240Vac 50/60Hz IEC 62262: IK08 - module with diffuser II 2 G, Ex d IIB or IIC T6 Gb for -20 C to +55 C XEL Range - Self contained & Slave II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 100-240Vac 50/60Hz 12-110Vdc Battery 3h - XFF EM (220-240Vac/Vdc 50/60Hz) IEC 62262: IK08 II 2 G, Ex de IIB or IIC T6 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T80 C or T70 C Db & IP66 for -20 C to +55 C 2x18W, 100-240Vac 50/60Hz 110Vdc Battery 3h - XFP EM (220-240Vac/Vdc 50/60Hz) IEC 62262: IK08 II2G, Ex d IIC T6 Gb or II2G, Ex de IIC T6 Gb II 2 D, Ex tb IIIC T80 C Db & 1x4W 220-240Vdc 50-60Hz Battery 1h or 3h IEC62262 : IK07 Weatherproof polycarbonate tubular light fitting for industrial application FFL Range - FF Range - Fluorescent Ingress protection IP66 ideal for wash down areas All components mounted on a removable gear tray which gives easy access for installation & maintenance Tubular shape to avoid waste accumulation Including accessories (cable gland & fixing brackets) Possibility to retro-fit gear tray into existing fixtures mounted with T8 lamps. IP66, -20 C to +55 C 100-254Vac 50-60Hz IEC 62262: IK09 - module with diffuser IP66, -20 C to +55 C 100-254Vac 50-60Hz Battery 3h - self test - FF EMB IEC 62262: IK09

PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Floodlights, warnings & wellglass XLF Range - XSF / XQF / XEF Range Floodlight fitting for Zones 1, 2, 21 & 22 & Industrial applications Integrated junction box Flat or pole mounting Including cable gland Supplied with offshore grade paint II 2 G, Ex de IIB T6 Gb for -20 C to +40 C or Ex de IIB T5 Gb for -20 C to +55 C or Ex de IIB T4 Gb for -20 C to +60 C II 2 D, Ex tb IIIC T85 C Db IP66 for -20 C to +40 C or Ex tb IIIC T100 C Db IP66 for -20 C to +55 C or Ex tb IIIC T135 C Db IP66 for -20 C to +60 C 105W 100-277Vac (+/- 10%) 50/60Hz Operating life > 50,000h (according to ambient temperature) IEC 62262: IK09 More than 7800 lumens output with narrow & wide beam II 2 G, Ex de IIB T3 or T4 or T5 Gb for -20 C to +40 C, Ex de IIB T4 or T3 Gb for -20 C to +55 C II 2 D, Ex tb IIIC T100 C or T135 C or T200 C Db IP66 for -20 C to +40 C, Ex tb IIIC T200 C or T135 C Db & HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz Flat or pole mounting SF / QF / EF Range Industrial applications Wellglass for industrial application & zones 2 & 22 - Wellglass Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge lamp according to models EVH, EVX Range - Wellglass II 2 GD, Ex d IIC T5 to T3 Gb, Ex tb IIIC T95 C to T164 C & HP Sodium: 70W, 150W, 250W, 400W Metal Halide: 150W, 250W, 400W Halogen: 70W, 140W, 250W 230Vac 50Hz Four 3/4 NPT entries - fitted with 2 plugs IP66, -20 C to +55 C HP Sodium: 150W, 250W, 400W Metal Halide: 250W, 400W Halogen: 2x70W 230Vac 50Hz Other Voltages: 220Vac 60Hz / 120Vac 60Hz Flat or pole mounting

LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Linear light fittings EVS Range - Fluorescent EVNL Range - Linear light fitting for all zones & Industrial applications Double central locking for ingress protection Automatic switch off upon opening for safe maintenance All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable gland & fixing brackets) II 2 G, Ex de IIC T4 Gb for -40 C to +60 C or Ex de IIC T5 Gb for -40 C to +35 C II 2 D, Ex tb IIIC T85 C Db & IP66 for -40 C to +60 C EVN Range - Fluorescent 108 to 254V ac or dc Battery 3h - EVS EM Battery 3h with automatic test and blackstart capabilities - EVS EMA II 3 G, Ex na IIC T5 for -40 C to +25 C, T4 for -40 C to +60 C Gc II 3 D, Ex tc IIIC T65 C for -40 C to +35 C or T85 C for -40 C to +60 C Dc Zones 2 & 22 EVDL Range - 100-254Vac 50-60Hz - module with diffuser II 3 G, Ex na IIC T4 Gc for -40 C to +40 C, Ex na IIC T3 Gc for -40 C to +60 C II 3 D, Ex tc IIIC T65 C Dc IP66 for -40 C to +40 C, Ex tc IIIC T85 C Dc & IP66 for -40 C to +60 C Zones 2 & 22 108-254Vac or dc Battery 3h - self test - EVN EMB II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 21 & 22 100-240Vac 50-60Hz - module with diffuser EVD Range - Fluorescent EVT Range - Fluorescent Industrial applications EVTL Range - Industrial applications II 2 D, Ex tb IIIC T85 C Db for -40 C to +60 C, Ex tb IIIC T65 C Db for -40 C to +35 C Zones 2, & 22 220-240Vac/Vdc 50-60Hz Battery 3h - self test - EVD EMB 108-254Vac or dc 50-60Hz Battery 3h - self test - EVT EMB 100-254Vac 50-60Hz - module with diffuser

PRODUCT OVERVIEW - LIGHT FITTINGS FOR ALL ZONES AND INDUSTRIAL APPLICATIONS Light fittings for all zones and industrial applications Recessed light fittings Recessed lighting fitting for zones 1 & 2 Steel housing and body powder paint coated 6mm clear toughened glass panel Including accessories (cable gland) ESB Range - Fluorescent II 2 G, Ex de IIC T4 Gb for -40 C to +60 C Zones 1 & 2 2x18W, 108-254Vac or dc 50/60Hz Battery 3h - ESB EM IEC 62262: IK08

LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES About ABB Value commitment 01 01 Oil & gas application 02 XEL About DTS DTS is part of the ABB group and provides a complete range of explosion proof lighting and emergency lighting. Our DTS range covers all zones of potential explosion gas & dust atmospheres and is compliant with most stringent national, European and international regulations including IECEx and ATEX standards, making it possible to be used in a wide variety of industries across most of the world. Our value commitment DTS is committed to helping you meet the challenges of corrosion prevention with electrical solutions, services and systems that deliver value. DTS helps to make your life easier by the practicality of its designs by providing effective advice and by being responsive to your need. 02

Thomas & Betts Ltd. Br. Member of the ABB Group Office 724 6WA West Wing Dubai Airport Free Zone PO Box 54567 Dubai United Arab Emirates T +971 (0)4 609 1635 F +971 (0)4 609 1636 E enquiryme@tnb.com Thomas & Betts Saudi Arabia Member of the ABB Group Building 128 Dammam Industrial Area #2 PO Box 514 Al Khobar 31952 Saudi Arabia T +966 (0)13 812 1222 F +966 (0)13 812 2981 E enquiryme@tnb.com www.abb.com new.abb.com/low-voltage/hazardous YouTube Channel Copyright 2018 ABB. All rights reserved. Specifications subject to change without notice. 9AKK107045A2778 REV A 23.12.2018