TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

Similar documents
FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Operating Instructions. For. Alarm Control Module. Model SSR 500

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DETECTION AREA OA-FLEX AIR T. Active Infrared Sensor FLEX EYE A X B C D E F G. Emitting area

Electrisaver User and Installation Instructions

M15051) INSTRUCTION MANUAL

OPTISENS TUR 2000 Technical Datasheet

Installation, Operating and Maintenance Manual

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Door Release Power Supply

RE-PR3-E-27 3-Phase Panel Mount 27kW

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

BENSON LINEAR RADIANT TUBE

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

User Information Sheet 008 : 2010

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

SECTION AUTOMATIC TRANSFER SWITCHES

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Hand Dryer Installation & User Manual

INSTRUCTION MANUAL A131 High Level Audible Warning System

Application, Installation, Operation & Maintenance Manual

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Electronic timeswitch

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

3 o/c2 The symbol used to show that a BS 88 device has a motor circuit application is a gg b gm c l z d I 2.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

SET-2000 Hi Level/Oil

Datasheet - AZM 161SK-12/12RK-024

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

F1202 TRACE HEATING. Road & Ramp

MBCE-110/230UV Flame Sensor Module

ELECTRICAL SAFETY for GAS ENGINEERS ACV. Do a GOOD JOB Take care of YOURSELF STAND OUT from the competition 2018 ISSUE 1. sterling4gas.co.

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

C106 Coded Access Keypad

OilSET-1000 (12 VDC)

Networked Access Control Panel. Installation Guide

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Fill Point, Level Gauges, and Control Range

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

INSTRUCTION MANUAL (ATEX / IECEx)

User Manual 120/240/300 Outdoor Motion Detector

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

Universal Tank Alarm Type Installation, Operation & Maintenance

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Datasheet - AZM 161SK-12/12RK-024

Heating Element. Building Technologies HVAC Products

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Flostop TS D7E and A8E. Operation Manual

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

IS09 ECN2087. EB3, EB4 & EB6 Automatic Fill Water Boilers INSTALLATION, USER & SERVICING INSTRUCTIONS

LC3000 Level Controller Installation and Maintenance Instructions

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

BC3250. Blowdown Controller

General Routing Interface

User manual and installation guide

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Original instructions AR

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

Self-Regulating Point Heating Performance Requirements

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Dual Input ph/orp Analyzer

Electronic 7 Installation Instructions

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Amendment Number 3 of BS how it might affect you

DOUBLE DISHDRAWER TM DISHWASHER

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Steam Mop Instructions for Use

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Instruction Manual WARNINGS

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

CMT MANUAL 6. NMC SENSORS

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Transcription:

3P Technik TCS5JBL & TCS5JBLA Low-Voltage Top-Up Switch Installation and Operation Manual 3P TCS5JBL/TCS5JBLA Page 1 11/09/16

Table of Contents Description Of Operation...2 Installation...2 Safety Precautions...2 Included Components...3 Layout...3 Control Panel Mounting...3 Connections...4 Float Switch...4 Solenoid...4 Mains Supply 230Vac...4 Operation...4 Safety Precautions...4 Adjustments...5 Specifications...5 3P TCS5JBL/TCS5JBLA Page 2 11/09/16

Description Of Operation The TCS5JBL Low Voltage Top-up Switch is intended to ensure the availability of water in a tank by topping up the tank when the level becomes low, with a measured amount of mains water. Water level in the tank is sensed via a float switch, and top-up of mains water is achieved via a solenoid valve connected to the mains water supply. The solenoid will be activated when the float switch reaches a downward angle of approx 45deg or more, the top-up cycle will then continue until the float switch reaches an upward angle of approx 45deg, thereby ensuring a measured quantity of water is introduced to the tank and avoiding unnecessarily frequent top-ups. The float switch and solenoid circuits are both powered by a safe low-voltage, either 24Vdc (TCS5JBL) or 24Vac (TCS5JBLA) with limited current and over-voltage protection. Installation Safety Precautions Mains Voltage There are exposed electrical conductors inside this appliance. This appliance must be installed and serviced by a competent electrical technician to the current requirements of BS7671 and IEEE recommendations. Before servicing this appliance, normal safe isolation procedures should be implemented. Do not touch any connection terminals while energised. Do not attempt to service this item when wet, or in a wet or high humidity environment. If the housing of the control panel becomes damaged, you must shut down and securely isolate this appliance immediately. Included Components TCS5JBL/TCS5JBLA Series Control Unit 2 x Male Connecting Plugs Layout The control panel can be mounted indoors or in sheltered outdoor locations (barns, covered areas, etc). It is rated at IP66 and will not withstand persistent and direct rain, immersion, etc. 3P TCS5JBL/TCS5JBLA Page 3 11/09/16

Voltage drop will affect the cable size needed to take power to your appliances. The more current is drawn the greater the effect over distance. Voltage drop will be greater with direct current versions. The float switch supplied is a 2 way float switch, it is set by default to close the circuit when the float is facing downwards. This suits the majority of tank re-filling applications. If desired it can be re-wired to close when the float is held upwards to suit tank drainage requirements. To do this the wiring within the plug attached to the float switch must be changed. The brown wire is common and connected to the voltage to be switched, blue returns voltage when the float is facing up and black returns voltage when the float faces downwards. Cables extension is straightforward using mains flex, there is no neutral, and there is no earth, only one pole is carried through the float switch. For the extension of float switch cables we recommend an IP68 cable joiner 3P Part number X20BKSD. Suitable circuit protection must be installed and should include as a minimum a suitable earth, overcurrent protection, and residual current protection at 30mA, ideally on it's own circuit, but always in accordance with BS7671 and applicable regulations. Control Panel Mounting Open the cover of the control panel. There are 4 recesses, one on each corner of the panel. Drill through at these locations and attach to the wall or a suitable support, taking care not to damage cabling inside the panel. Fixings are not included and should be selected to suit the material to which the panel will be mounted. Connections Float Switch The 2 outer poles in the plug should be used. Polarity is unimportant for the float switch connection. If you are using a double switching float switch (3 wires), select the 2 wires which connect when the float switch is hanging downwards. The float switch cable should be fastened within the tank between the points at which you want the top-up cycle to start and stop. The distance between start and stop is determined by the length of free cable to the float. Solenoid The polarity of the solenoid connection is unimportant if you have the AC version of this unit (TCS5JBLA). If using the DC version, the pole marked L in the plug will be positive, and the pole marked N will be negative, although it is good practice to verify this with a multimeter during 3P TCS5JBL/TCS5JBLA Page 4 11/09/16

installation. Mains Supply 230Vac The mains power supply cable is pre-wired. Connect to a fused outlet or isolator as usual. This is a Class 2 isolated appliance without earth, but the earth wire must still be connected and validated as usual to provide safety in the event of damage to the supply cable. Current draw is shown at the end of this manual under Specifications. NOTE Do not coil the cables, cut them to an appropriate length. Coiled cables suffer increased impedance and are susceptible to voltage induction from nearby circuits and appliances. Where possible try to maintain a separation of at least 150mm between mains power cables and low voltage cables. Operation Safety Precautions Mains Voltage There are exposed electrical conductors inside this appliance. This appliance must be installed and serviced by a competent electrical technician to the current requirements of BS7671 and IEEE recommendations. Before servicing this appliance, normal safe isolation procedures should be implemented. Do not touch any connection terminals while energised. Do not attempt to service this item when wet, or in a wet or high humidity environment. If the housing of the control panel becomes damaged, you must shut down and securely isolate this appliance immediately. Adjustments Operation is automatic. There are no adjustments to be made at the control unit. Non-weighted float cables The level around which the system starts and stops the top-up cycle can be adjusted by moving the point at which the float cable is attached within the tank. The top-up duration can be adjusted by increasing or decreasing by the length of free cable to the 3P TCS5JBL/TCS5JBLA Page 5 11/09/16

float. Weighted float cables If your float switch has a weight attached along it's length, the position of that weight can be adjusted. You may need to secure it with a cable tie. The level around which the system starts and stops the top-up cycle can be raising or lowering the float into the tank. The top-up duration can be adjusted by increasing or decreasing by the length of free cable between the float and the weight. Specifications Dimensions (W x H x D) 130mm x 94mm x 57mm Enclosure Material Polystyrene Ingress Protection IP66 UV Resistant Output TCS5JBL 24Vdc 0.63A max TCS5JBLA 24Vac 1.25A max 3P TCS5JBL/TCS5JBLA Page 6 11/09/16