Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs 3 year warranty as standard
CONTROL PANEL GENERAL SPECIFICATION IP rating Operating Temperature ( c) 2, 4, 6, 8, 10, or 12 zone conventionally wired or Twin Wire combined detection & sounder circuits fused at 500ma 4k7 Ohm 5% 0.25w EOL resistor IP30-5 c to +40 c Operating Humidity <95% Standby Current 75mA (2 zone) 85mA (4 zone) plus 42mA for each 4 zone standard extension card and 49mA for each high spec extension card Alarm load 2.4 amps shared between all sounder outputs Common fire relay Common fault relay External inputs Outputs Mains Supply & fuse Power supply rating Battery charging voltage Auxiliary supply to field accessories Max. battery size & space Volt free no/c/nc contact rated 3 amp @30 Vdc Volt free no/c/nc contact rated 3 amp @30 Vdc Class change and Alert pulse sounders Non latching switched ve inputs. Max input voltage 28Vdc Fire and fault common outputs Switched ve voltage outputs for external relay control, max load 40mA 230vac +10 / -15% 50Hz protected by 4 Amp fuse 3 Amp including battery charging 27.3 Vdc @20 O C 28Vdc fused @ 500mA 2 x 7Ah max 12volt VRLA ( Use Yuasa NP range batteries) Terminal Capacity 0.5mm 2 to 2.5mm 2 Cable entry Enclosure material and colour Panel dimensions (mm W x H x D) 20 x 20mm top entry knockouts 8 x 20mm rear entry knockouts Mild Steel, Epoxy powder coated silver grey Colour ref: Radon MW334E Interpon powder coat 455 x 310 x 85 mm Approvals LPCB approved to EN54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 by LPCB
Internal construction The main circuit board comprises of 2 or 4 zone circuits. The 6, 8 & 12 zone panels are constructed by adding 4 zone extension cards to the motherboard. There are 2 versions of the 4 zone extension cards, High Specification and Standard. Each high specification extension cards include additional switched ve outputs, am auxiliary relay output and two monitored sounder outputs. Panel size Motherboard 4 Zone extension cards Hi Spec Standard 2 zone 2 zones n/a n/a 4 zone 4 zones n/a n/a 6 zones 2 zones 1 or 1 8 zones 4 zones 1 or 1 12 zone 4 zones 2 or 2 or one of each HIGH SPEC 4 ZONE EXTENSION CARD SPECIFICATION 4 zone conventionally wired or Twin Wire combined detection & sounder circuit fused at 500mA 4k7 Ohm 5% 0.25w EOL resistor Standby Current Outputs 49mA 2 x programmable switched ve voltage outputs for external relay control, max load 40mA 1 x auxiliary relay output STANDARD 4 ZONE EXTENSION CARD SPECIFICATION Standby Current 4 zone conventionally wired or Twin Wire combined detection & sounder circuit fused at 500mA 4k7 Ohm 5% 0.25w resistor 42mA
CONTROL PANEL SPECIFICATION continued: Front of panel indications External Controls at access Level 2: (Access by key switch or code entry) External Controls at access Level 3: (Access by key switch or code entry) Internal controls Zones in Fire Zones in Fault, Disabled or In Test Mode Supply Healthy General Fire General Fault General Disablement Test Mode Sounder Status Aux Output Status Power Supply Fault Delay status Repeater fault System Fault Access Level Colour coded buttons for controls and programming Button functions: Resound alarms Silence alarms Reset Disable Mode Test Mode Mute Buzzer Test Lamps Enter View event history Set buzzer volume Clear all disablements Initialise factory settings Panel wide settings including: change keypad access code set delay time set number of repeater panels Set zonal functions including: non latching zones short circuit fire detector removal monitoring silent mode Set panel & zones to dependency mode Select sounder resound zone options (EN54 requirement) Program inputs Program outputs Program repeater panels PSU Voltage adjustment DIL switches: Zonal Twin Wire mode Zone interface quick set Access level 3 mode
2 to12 ZONE PANEL DIMENSIONS