Excel-EN Conventional Fire Control Panel

Similar documents
Intelligent Security & Fire Ltd

Conventional & Twin-wire Fire System

Precept Marine Control Panel Application Guide

Installation, Operating and Maintenance Manual

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Intelligent Security & Fire Ltd

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Application, Installation, Operation & Maintenance Manual

Installation, Commissioning & Operating Manual

OPERATION AND INSTALLATION MANUAL

System 800 Addressable Fire Detection & Alarm System

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

The EN54 Part 2 and 4 Fire System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Installation, Commissioning & Operating Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Conventional Fire Alarm System 2014 V1.2

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

FireNET Plus Wiring Instructions

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

SALES SUPPORT DOCUMENT

An introduction to... Sigma

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

4 wire conventional alarm system

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

ZXSe Range Data Sheet

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

User Operation Manual

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Menvier Fire System MF9300

GAS SUPRESSION CONTROL PANEL:

FEC400 Series. Installation Manual

The EN54 Part 2 & 4 Fire System

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Conventional Fire Control Panel

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

MR-2602 Two Zone Fire Alarm Control Panel

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

Model 17A00 Expansion Enclosure

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Surveyor Envoy-MINI 4

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Technical Data Sheet

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

Conventional Leaflets

Operation and Maintenance Manual

Commercial and Light Industrial Fire Alarm Control Panel

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Installation Manual Premier 412/816/832. Issue 10

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

TECHNICAL DATA OBSOLETE

Components Brochure DX CONNEXION

MINERVA MX. 800 Series Ancillary Equipment

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

Intelligent addressable fire alarm control panel

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

EXTINGUISHING AGENT RELEASE MODULE

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

The complete conventional fire warning system

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

INSTALLATION MANUAL PC56O. Version 1.OA

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL NEW ZEALAND EDITION. 27/05/2015 Rev C DOC

ACP10 & ACP50 Security Systems

Flair 500 Series Annunciators

General Routing Interface

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Transcription:

Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs 3 year warranty as standard

CONTROL PANEL GENERAL SPECIFICATION IP rating Operating Temperature ( c) 2, 4, 6, 8, 10, or 12 zone conventionally wired or Twin Wire combined detection & sounder circuits fused at 500ma 4k7 Ohm 5% 0.25w EOL resistor IP30-5 c to +40 c Operating Humidity <95% Standby Current 75mA (2 zone) 85mA (4 zone) plus 42mA for each 4 zone standard extension card and 49mA for each high spec extension card Alarm load 2.4 amps shared between all sounder outputs Common fire relay Common fault relay External inputs Outputs Mains Supply & fuse Power supply rating Battery charging voltage Auxiliary supply to field accessories Max. battery size & space Volt free no/c/nc contact rated 3 amp @30 Vdc Volt free no/c/nc contact rated 3 amp @30 Vdc Class change and Alert pulse sounders Non latching switched ve inputs. Max input voltage 28Vdc Fire and fault common outputs Switched ve voltage outputs for external relay control, max load 40mA 230vac +10 / -15% 50Hz protected by 4 Amp fuse 3 Amp including battery charging 27.3 Vdc @20 O C 28Vdc fused @ 500mA 2 x 7Ah max 12volt VRLA ( Use Yuasa NP range batteries) Terminal Capacity 0.5mm 2 to 2.5mm 2 Cable entry Enclosure material and colour Panel dimensions (mm W x H x D) 20 x 20mm top entry knockouts 8 x 20mm rear entry knockouts Mild Steel, Epoxy powder coated silver grey Colour ref: Radon MW334E Interpon powder coat 455 x 310 x 85 mm Approvals LPCB approved to EN54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006 by LPCB

Internal construction The main circuit board comprises of 2 or 4 zone circuits. The 6, 8 & 12 zone panels are constructed by adding 4 zone extension cards to the motherboard. There are 2 versions of the 4 zone extension cards, High Specification and Standard. Each high specification extension cards include additional switched ve outputs, am auxiliary relay output and two monitored sounder outputs. Panel size Motherboard 4 Zone extension cards Hi Spec Standard 2 zone 2 zones n/a n/a 4 zone 4 zones n/a n/a 6 zones 2 zones 1 or 1 8 zones 4 zones 1 or 1 12 zone 4 zones 2 or 2 or one of each HIGH SPEC 4 ZONE EXTENSION CARD SPECIFICATION 4 zone conventionally wired or Twin Wire combined detection & sounder circuit fused at 500mA 4k7 Ohm 5% 0.25w EOL resistor Standby Current Outputs 49mA 2 x programmable switched ve voltage outputs for external relay control, max load 40mA 1 x auxiliary relay output STANDARD 4 ZONE EXTENSION CARD SPECIFICATION Standby Current 4 zone conventionally wired or Twin Wire combined detection & sounder circuit fused at 500mA 4k7 Ohm 5% 0.25w resistor 42mA

CONTROL PANEL SPECIFICATION continued: Front of panel indications External Controls at access Level 2: (Access by key switch or code entry) External Controls at access Level 3: (Access by key switch or code entry) Internal controls Zones in Fire Zones in Fault, Disabled or In Test Mode Supply Healthy General Fire General Fault General Disablement Test Mode Sounder Status Aux Output Status Power Supply Fault Delay status Repeater fault System Fault Access Level Colour coded buttons for controls and programming Button functions: Resound alarms Silence alarms Reset Disable Mode Test Mode Mute Buzzer Test Lamps Enter View event history Set buzzer volume Clear all disablements Initialise factory settings Panel wide settings including: change keypad access code set delay time set number of repeater panels Set zonal functions including: non latching zones short circuit fire detector removal monitoring silent mode Set panel & zones to dependency mode Select sounder resound zone options (EN54 requirement) Program inputs Program outputs Program repeater panels PSU Voltage adjustment DIL switches: Zonal Twin Wire mode Zone interface quick set Access level 3 mode

2 to12 ZONE PANEL DIMENSIONS