Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Similar documents
Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Allure EC-Smart-Air Series Communicating sensors

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Accuracy by Design Products for the HVAC Professional

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Carbon Monoxide CO Transmitter ADT-X3-1110

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger REGARD -1 Control System

C7232A,B Sensor and Controller

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Model D12-IR. Digital Gas Transmitter...

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

CLEANROOM MONITOR CR3A Network - Installation Instructions

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Key Features. General Description

Product Catalogue. Air and Gas Sensors. Save Life and Energy

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

APPLICATION DATA SHEET

User's Guide. CO 2 Monitor. Model CO200

Dräger Polytron 8310 IR Detection of flammable gases and vapour

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Multi-Gas-Controller MGC2

A New Standard of Excellence

Datasheet: K-22 LO Sensor

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Inc Series Digital Gas Detector/Controller. Operation Manual

Dräger REGARD -1 Control System

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Carbon Monoxide Transmitter

Dräger Polytron 8700 IR Detection of flammable gases and vapors

EasyLog Data Logger Series

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

HUM-M2 Humidity Sensor Module Description

Outside Air Humidity & Temperature Sensor

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

EasyLog Data Logger Series

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Duct Humidity/Temp Sensor

Dräger Polytron 5100 EC Detection of toxic gases and vapors

APPLICATION DATA SHEET

Dräger Polytron 8720 IR Detection of carbon dioxide

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

Danfoss gas detection units

CN7232 Advanced Garage Ventilation Controller

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Danfoss gas detection units

Using the DewTrak II Dew Point/ Humidity Transmitter

I/A Series 716C 1/16 DIN Temperature Controller

Oxygen (O2) Single-Point Gas Detection System

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Dräger Polytron 7000 Fixed gas detector

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

RSMFM-2R MULTIFUNCTIONAL

KANE-ALERT-CO 2 Monitor with Temperature

Lamp Supply (Recommended)

Gas Controller Module GC-06

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Hydrazine Analyzer Series 2171 Specifications

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

QPM21 Series Duct CO 2 and Air Quality Sensors

High-accuracy Multi-sensor IAQ Detector MSD Commercial grade for intelligent& green buildings

Dräger PointGard 2100 Detection of toxic gases and vapours

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

S5000 Gas Monitor. GMS5000.com

TER Active Room Temperature Sensor (Controller),

Model Q45P/R. ph/orp Monitor...

CD-Px Series Duct Mount CO 2 Transmitters

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Sensor Selection Guide. Sensing for Building Applications

Specifications Minimum Typical Maximum Unit

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Duct and Rough Service Carbon Monoxide Sensor

Controllers. Instruction Manual WARNING

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Warranty Registration

Transcription:

Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. Patented ABC Logic self-calibration system eliminates the need for manual calibration in most applications. Lifetime calibration guarantee when using ABC Logic. Mounting plate with two-piece terminal blocks provide quick, easy wiring. Gas permeable, water resistant diffusion ilter prevents particulate and water contamination of the sensor. Dual simultaneous analog outputs (V & ma) available for. BACnet output versions Sensors are shipped factory calibrated. Temperature sensor on all models. Modern enclosure with customized branding available., humidity and temperature models. Two-piece design allows unit to be replaced without the need for rewiring. Locking screw secures cover and sensor to the mounting bracket for tamper resistance. Amphenol Advanced Sensors

Controlled Ventilation Ventilation is an important part of maintaining a comfortable, healthy, productive environment for people. Improper ventilation can have a negative impact on occupant health and performance, increase the risk from litigation, and/or waste energy. Demandcontrolled ventilation using sensors prevents energy losses from over-ventilation while maintaining indoor air quality. The most energy savings potential is in buildings where occupancy luctuates during a 24-hour period. Numerous organizations now require and/or recommend -based ventilation control in different commercial HVAC applications. Some utility companies also offer rebates to building owners for installing sensors. Wall mount sensors are used to control a speciic area such as a conference room, classroom, meeting hall, etc. The Telaire 8000 Ventostat series are easy to install and have a clean, modern look that suits most indoor environments. Ordering Information Examples: T8100-D ABC Logic, display T8100-D-BAC ABC Logic, display,bacnet T8200-HD Dual channel, Humidity, Display T8300-BAC ABC Logic, pitotot tube, BACnet T8100-DB ABC Logic, display, black case The Telaire 8000 Ventostat series is available in a number of conigurations. The primary coniguration is determined by the type of sensor included. T8100 uses a single channel sensor using Telaire patented ABC Logic for lifetime calibration. Singlechannel sensors are used in spaces where there is not full-time occupation (most applications). T8200 uses a dual-channel optical system and three-point calibration process for enhanced stability, accuracy and reliability. Used in applications where there is full-time occupation 24 hours a day. T8300 uses a single channel sensor with pitot tube kit for duct measuring of. ABC Logic enabled. Notes: 1. This product is intended to be used in occupied building HVAC applications. 2. This product is not designed or intended for use in safety critical functions. T8 100, 200, 300 Humidity (H) Display (D) Color (B, W) Range (5P, 10P) BACnet (BAC) T8 Note: Not all combinations are available, i.e., T8300 with humidity. Please see www.ventostat.com to see the latest list of available part numbers. Note: T8100-5P-R versions are conformally coated. Black versions are for applications such as movie theaters 2

Wall Mount Speciications Sensing Method Non-dispersive infrared (NDIR) absorption Gold-plated optics Patented ABC Logic self calibration algorithm Measurement Range T8100/T8200/T8300 0 to 2000 ppm (0 ppm = 0 V, 4 ma; 2000 ppm = 10/5V, 20 ma) T8100/T8200/T8300-5P models 0 to 5000 ppm (0 ppm = 0 V, 4 ma; 5000 ppm = 10/5V, 20 ma) T8200 (10P models) 0 to 10,000 ppm (0 ppm = 0 V, 4 ma; 10,000 ppm = 10/5V, 20 ma) T8200 (20P models) 0 to 20,000 ppm (0 ppm = 0 V, 4 ma; 20,000 ppm = 10/5V, 20 ma) Accuracy ± 30ppm or 3% of the reading shown, whichever is higher * Power Supply Requirements 18-30 VAC RMS, 50/60 Hz, or 10.8 to 42 VDC, polarity protected Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS Temperature Dependence 0.2% FS per C (±0.11% per F) Stability T8100/T8300 - Single Channel <2% of FS over life of sensor (15 years) T8200 - Dual Channel <5% of FS or <10% reading annual over life of sensor (10 years) Pressure Dependence 0.135% of reading per mm Hg Warranty 24 months on mechanical defects Calibration - lifetime warranty for T8100 and T8300 series Certifications CE and RoHS compliant Signal Update Every 5 seconds Warm-up Time < 2 minutes (operational) 10 minutes (maximum accuracy) Operating Conditions 32 F to 122 F (0 C to 50 C) 0 to 95% RH, non-condensing Storage Conditions -40 F to 158 F (-40 C to 70 C) Flammability Classification UL94 5VA Passive Thermistor Type (not Bacnet version) NTC 10 K W thermistor Thermistor Accuracy ±1 C (15 to 35 C) RH Sensing Element Capacitive polymer sensor RH Range 0% to 99% RH (non-condensing) RH Accuracy (25 C) ±2.5% RH (20 to 80% RH) ±3.5% RH (<20% and >80% RH) Active Temperature Accuracy ±0.8 C @ 22 C Active Temperature Range 32 F to 122 F (0 to 50 C) Note: Active analog output standard and only available on T8100-R and T8100-H versions. Output Analog Version 0 to 10 V (100 W output impedance) and 4 to 20mA (R L maximum 500 W) available simultaneously BACnet Version MS/TP RS485 Baud rates 38400 or 9600 *C0 2 accuracy statement excludes standard gas used for calibration that has an accuracy of 2%. In addition, there is a potential digital to analog error of up to 1%. 3

Note: Applies when used in typical indoor ambient air. Consult Telaire if other gases or corrosive agents are part of the application environment. Calibration Guarantee Telaire is serious about minimizing maintenance, so each single-channel sensor (T8100/T8300) comes with a lifetime calibration guarantee. And each dual channel sensor has a two-year calibration guarantee (T8200). Calibration Interval For T8100 and T8300 series, no calibration is required due to ABC Logic. For T8200 series, annual calibration is recommend for the best accuracy. However, most applications using T8200 series could extend the calibration interval. For the humidity sensor, no calibration is required. Replacement humidity sensors are available. If a Telaire 8000 series single channel sensor drifts out of calibration range, it can be sent back to Telaire for a free factory calibration. Further information on the guarantee is available on our website. Ventostat wall mount dimensions Sensor Accuracy & Field Calibration ABC Logic Self Calibration T8100 and T8300 single channel sensors employ the patented ABC (Automatic Background Calibration) Logic self-calibration system. ABC Logic virtually eliminates the need for manual calibration in applications where the indoor level drops to outside levels during unoccupied periods (e.g. during evening hours). ABC Logic is a special software routine in the sensor that remembers the background readings for 14 consecutive evenings, calculates if there is a sensor drift, and then corrects for it. T8200 Dual Channel The T8200 dual channel sensor can be described as a channel that measures gas concentration and a reference channel that measures the sensor signal intensity. The dual channel sensor performs periodic self-calibrations using the reference channel. The selfcalibrations are approximately every 24 hours. During the self-calibration the sensor ppm reading is frozen, it will not react to changing. The calibration time is adjustable but nominally two minutes. Telaire recommends periodic gas calibration depending on the application accuracy requirements. While the reference channel corrects for changes over time, a ield calibration using nitrogen gas or alternatively ambient calibration will immediately restore the highest level of accuracy. Refer to the calibration manual for details. With ABC Logic enabled, the sensor will typically reach its operational accuracy after 25 hours of continuous operation at a condition that is exposed to ambient reference levels. Sensors will maintain accuracy speciications with ABC Logic enabled, given that it is at least three times in 14 days exposed to the reference value and this reference value is the lowest concentration to which the sensor is exposed. 4

Multi Measurement Display versions scroll between ppm, %RH Humidity and F Temperature when the option is selected. Wiring Features Non-Display Wiring No display, basic functionality for and passive thermistor only. Display Wiring Digital display, functions of and thermistor are standard. Humidity and active temperature options are available. Display scrolls all measurements that are included. Non-Display Wiring Display Wiring BACnet Wiring 5

Smaller Enclosures Smaller enclosure versions are available for regional preferences. Dimensions: 81.4 mm x 86.4 mm 8300 Pitot Tube Configuration The pitot tube kit is used for duct measurement of. The pitot tube is installed in the duct and the sensor is mounted remotely, which allows for easy access. Enhanced Field Serviceability The Ventostat 8000 series features a ield-replaceable Relative Humidity (RH) sensor tip module that allows the end user to replace the sensor on-site while maintaining ±2.5% RH accuracy. The user simply powers off the unit, installs the new sensor module and powers back the unit. This virtually eliminates the need for time consuming and costly factory calibration, while reducing downtime during service intervals to near zero. The sensor is protected from dust contamination by a specially designed ilter as shown in the photo below. Pitot Mounting Coniguration T8300-D with Pitot T8300 with Pitot 6

Ventostat Accessories Enclosure Specifications T1508 Aspiration Box for Duct Mounting The Model 1508 is designed for in-duct sampling of concentrations at low rates greater than 400 fpm. Clear cover allows for observation of the sensor. They will accommodate any of the Ventostat 8100 or 8200 series, and can be used for temperature and RH when itted. Enclosure is screwed to the duct with probe inserted into air stream. Air sampling probe is 1-inch (25.4mm) diameter and 8-inch (203.2mm) long. Enclosure (ABS plastic) has knockouts for conduit connection. Note: Wiring penetrations must be sealed prior to use. sensor not included. T1505 Splash Resistant Enclosure The Model 1505 is designed to protect the 8000 series in damp or wet environments as might occur in agricultural, industrial or food processing environments. This enclosure (ABS plastic) is designed to protect the sensor from dripping or sprayed water. Any wall mount model of the Ventostat 8000 series sensor can be installed inside the enclosure. The transparent cover allows for viewing of the sensor/display. Four diffusion ports allow for entry of. Knockouts are provided for conduit connection. Response time of the sensor is slowed to approximately 30 minutes to measure a 90% step change in concentrations. Enclosure is designed to screw directly to a wall. sensor not included. T1552 Outside Air Enclosure The Model 1552 is a rugged weatherproof enclosure (ABS plastic), designed to allow the 8000 series sensor to operate in an outdoor environment and/or where ambient temperatures are below freezing. The 1552 is ideal for monitoring outside air or as a surrogate for combustion fumes in parking garages, tunnels and loading docks. This enclosure features a temperature control circuit and internal heaters to maintain the sensor within its normal operating temperature range, even if temperatures outside the enclosure are as low as -20 F (-29 C). Four diffusion ports allow for entry of. Response time of the sensor is slowed to approximately 30 minutes to measure a 90% step change in concentrations. Enclosure is designed to screw directly to a wall. sensor not included. Power consumption is 24V, 1.5 Amp (max), and includes the Ventostat 8000 series. T1508 Aspiration Box for Duct Mounting T1505 Splash Resistant Enclosure and T1552 Outside Air Enclosure 7

Ventostat UIP Software The Ventostat UIP software allows you to modify the standard settings on the T8100, T8200 and T8300 series products. The software features: Altitude adjustment for maximum accuracy performance Analog output adjustment Single point and span gas calibration Turn on and off ABC Logic Change temperature display units Graphing and logging of, temperature and %RH (H Versions only) The software can be used by distributors to make modiications to the Ventostat prior to shipping to the customer, as well as to make adjustments in the ield. The USB cable supplies power to the Ventostat, negating the need for a separate power supply. The T2090 UIP software kit is supplied with a USB-to- Ventostat cable and software CD. Amphenol Advanced Sensors www.amphenol-sensors.com 2014 Amphenol Corporation. All Rights Reserved. Speciications are subject to change without notice. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. AAS-920-585D-11/2014

Part No T8100-E T8100-E-D T8100-E-H Description Wallmount CO2 Sensor for standard ventilation applications with ntc. Wallmount CO2 Sensor for standard ventilation applications, digital CO2 display and ntc. Wallmount CO2 Sensor for standard ventilation applications with active temp and humidity, and ntc. T8100-E-HD Wallmount CO2 Sensor for standard ventilation applications active temp and hum outputs, digital display. T8100-E-D-R Wallmount CO2 Sensor for standard ventilation applications active temp and hum outputs, digital display, low voltage relay. T8100-NS Wallmount CO2 Sensor for standard ventilation applications with ntc and Night setback. US size case. T8100-NSP T8100-E-BAC Wallmount CO2 Sensor for standard ventilation applications with ntc, potentiometer, and Night setback. US size case. Wallmount CO2 Sensor for standard ventilation applications with BACnet MS/TP output. T8100-E-D-BAC T8100-E-H-BAC T8100-E-HD- BAC * T8100-E-H- MOD * T8100-E-HD- MOD T8200-E Wallmount CO2 Sensor for standard ventilation applications with BACnet MS/TP output and digital display. Wallmount CO2, Humidity, & Temp Sensor for standard ventilation applications with BACnet MS/TP output. Wallmount CO2, Humidity, & Temp Sensor for standard ventilation applications with BACnet MS/TP output & digital display. Wallmount CO2, Humidity, & Temp Sensor for standard ventilation applications with Modbus output. Wallmount CO2, Humidity, & Temp Sensor for standard ventilation applications with Modbus output & digital display Wallmount CO2 Sensor for 24/7 ventilation applications with ntc. T8200-E-D T8200-E-HD Wallmount CO2 Sensor for 24/7 ventilation applications with digital CO2 display and ntc. Wallmount CO2 Sensor for 24/7 ventilation applications with active temperature and humidity outputs, digital display. T8200-E-D-5P- R T8200-E-BAC Wallmount CO2 Sensor for 24/7 ventilation applications (0~5k) with digital CO2 display, relay, and ntc. Wallmount CO2 Sensor for 24/7 ventilation applications with BACnet MS/TP output. T8200-E-D-BAC T8200-E-H-BAC Wallmount CO2 Sensor for 24/7 ventilation applications with BACnet MS/TP output and digital display. Wallmount CO2, Humidity, & Temp Sensor for 24/7 ventilation applications with BACnet MS/TP output. T8200-E-HD- BAC T8300-B T8300-DB T8300-B-BAC T8300-DB-BAC T8100-B T8100-DB Wallmount CO2, Humidity, & Temp Sensor for 24/7 ventilation applications with BACnet MS/TP output & digital display. Kit to sample duct air via pitot tube and measure CO2 in normal ventilation applications. Black US size case. Kit to sample duct air via pitot tube and measure CO2 in normal ventilation applications with digital display. Black US size case. Kit to sample duct air via pitot tube and measure CO2 in normal ventilation applications. BACnet MS/TP Output. Black US size case. Kit to sample duct air via pitot tube and measure CO2 in normal ventilation applications with digital display BACnet MS/TP Output. Black US size case. Wallmount CO2 Sensor for standard ventilation applications with ntc. Black US Size Case. Wallmount CO2 Sensor for standard ventilation applications, digital CO2 display and ntc. Black US size case. T8100-HDB Wallmount CO2 Sensor for standard ventilation applications active temp and hum outputs, digital display. Black US Size Case. T8200-B Wallmount CO2 Sensor for 24/7 ventilation applications with ntc. Black US Size Case. 1 of 2

T8200-DB T8200-HDB Wallmount CO2 Sensor for 24/7 ventilation applications with digital CO2 display and ntc. Black US Size Case. Wallmount CO2 Sensor for 24/7 ventilation applications with active temperature and humidity outputs, digital display. Black US Size Case. T8700-E T8700-E-D Wallmount Temp and Humidity Sensor with ntc. Wallmount temp and Humidity Sensor with digital display and ntc. * T8700-E-MOD Wallmount Humidity Sensor with Modbus Output T8041 Ventostat Duct Probe CO2 Transmitter (0-10V Output, <150mm duct) T8042 T5100-E-V T5100-E-I T5100-E-LED T8013 T9002 Part No T1505 Ventostat Duct Probe CO2 Transmitter (0-10V Output, >150mm duct) Wallmount CO2 Sensor (factory set 10v, 5v available by jumper GE branding) Wallmount CO2 Sensor (4-20 ma, EU Case, GE branding) Wallmount CO2 Sensor with LED (factory set 10v, 5v available by jumper GE branding) Airestat CO2 Transmitter. (85-230V supply) 6 colour LED indication, 230V rated output switch. Vaporstat Dew Point Sensor Sensor Accessories Water Resistant 1505 - Wall mount NEMA 3-R enclosure to protect sensor from excessive moisture or water spray. ABS plastic enclosure, four diffusion ports allow for entry of, knockouts are provided for conduit connection. T1552 Outside Air 1552 - Rugged weatherproof enclosure (ABS plastic), designed to protect sensor from excessive moisture or water spray. It is ideal for monitoring outside air or as a surrogate for combustion fumes in parking garages, tunnels and loading docks. T63164 T63139 T2090 Calibration Cerificate. Please note this must be ordered with the relevent sensor 24V international power adaptor suitable for supplying T5000, T8000, and T9000 series sensors. Customer will need to install wiring to sensor. Ventostat User Interface Program (UIP) including disc and USB connection cable. Part No T7001 Handheld Monitors Standard /Temperature Monitor Battery (4 AA) powered sensor, large ppm display, 0-4 V output, with calibration/flow through port and no power adaptor. T7001Di RH & Datalogger Combines the Telaire 7001 and a built-in RH/Temp Datalogger, Interface Cable & Graphing Software. This combo allows for measuring, recording and graphing, Temp and RH. Package includes international power adapter (62933). T7001i Standard /Temperature Monitor Battery (4 AA) powered sensor, large ppm display, 0-4 V output, with calibration/flow through port. Package includes international power adapter (62933). T7001SKi AQ/DCV Starter Kit Standard /Temperature Monitor, Adapter, Interface Cable and CD Containing Real Time Graphing Software & IAQ Reference Library. Package includes international power adapter (62933). Part No T2077 Handheld Accessories Data Logger & Software that attaches to the back of the 7001 and is equipped with a custom cable to read levels via the RJ-45 connection. One additional port is available to record a fourth gas. Includes datalogging software. May also be used as standalone to measure RH and temperature. T2080 Real Time Software program that displays and graphs real-time levels at a user adjustable time interval. The program records CO2 levels in a sequential format but does not record the time of the measurement. View allows the user to perform a zero and span calibration (gases sold separately) on the Telaire 7001 sensor. Supplied with interface cable. T2070 3 ft Voltage output cable (RJ-45) with the two stripped leads (temperature and ) to connect to any other device accepting a 0-4V output. One lead connects to the back of the Telaire 7001 while the stripped lead connects to a third party device. Voltage output cable with 2 pigtail leads to connect to standard dataloggers. 2 of 2