Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

Similar documents
Daikin Altherma Selection Report

NEW AQUAREA RANGE HIGH-EFFICIENCY HEAT PUMP TECHNOLOGY A++

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

Performance of Solar Water Heating Systems in the United States

Equipment ATA 12 April 2016

The Ed Roberts Campus Berkeley, CA

Heat Pumps and Public Swimming Pools, a Perfect Match

DISTRICT HEATING SCHEME FEASIBILITY STUDY FRANKTON FLATS QUEENSTOWN

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013

Economic Analysis of Solar Assisted Chemical Heat Pump Dryer

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

Better Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results

Storing excess daytime solar energy to heat greenhouse at night!

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

MEASURED PERFORMANCE DATA FOR

Cork County Energy Agency

System Using Exhaust Heat from Residential GHPs

New Steps towards Compact Solar Combisystems in Scandinavia

Living the (Solar) Dream Powering your lifestyle with the sun Ron Kube. Photo: Great Canadian Solar

Heat Consumption Assessment of the Domestic Hot Water Systems in the Apartment Buildings

Copyright 2003 IBACOS, Inc. All rights reserved.

Keep your electricity bill cool this summer

announcements 4/10/08

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno

Cooling Options for Geothermal and Concentrating Solar Power Plants

The new standard. The advanced solar absorber tube. The collector for every budget. Efficient modular installation system

CHART PERUVIAN TECHNICAL STANDARDS

Free cooling on RTAF Chiller. Integrated option

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Annual environmental performance evaluation of light and heat in daylight harvesting systems using Radiance and NewHASP

SOUTHEND CARELINE ANNUAL REPORT

MASTER PLAN KICK-OFF Open House #1A, April 28, 2015

WLAC Facilities Committee Meeting. September 18, 2017

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis

On Balance: Heat Rejection Control a Packaged Solution

OCHSNER CO 2 heat pipes an option for vertical collectors

Energy efficient climate control in museum stores. Poul Klenz Larsen

Standardization Programme ( ) Building & Construction Standards Committee

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

Solar Heating Solutions

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Remodeling Market. Kermit Baker. Remodeling Futures Conference November 9, Harvard University JOINT CENTER FOR HOUSING STUDIES

Boulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Oct. 19, 2017

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects

Dehumidification: Energy Efficiency Comparisons

Energy Efficient Measures That Add Little or no. Program Lights & Appliances: How To Benefit from the Low-Hanging Fruit

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Sustainable Hot Water: Better Design, Delivery, and Use

Boulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Nov. 2, 2017

Appendix A. Reference Evapotranspiration (ETo) Table.

Compact and efficient.

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR RESIDENTIAL BUILDINGS

Generation gap: How baby boomers and millennials stack up in their perceived and actual electricity use. Report. March 2019 BCH19-217

LEASEHOLD YEARLY PROPERTY SCHEDULE

THREADING TURNING MILLING BROACHING RUBBING HONING SPINNING LAPPING HOBBING DRILLING

Asparagus Response to Water and Nitrogen

High-Temperature Cooling & Low-Temperature Heating AC System Evaluation of energy saving in an office in Tokyo

Farm Energy Audit Workshop

The complete heating system

Food Control Plans or National Programmes Cold Hold Records 2019

Estimated Household Water Heater Energy Use, Running Costs and Emissions, Victoria. Based on energy price projections,

User manual. JASPI COMFORT MONO 8 & 12Kw UK 1x230V. Air/water heat pump LEK

Heat Recovery Systems PTG, SWT Series.

Continuous Commissioning: A Valuable Partner to Retrofit Projects

COST REDUCTION BY REPLACING STEAM WITH COKE OVEN GAS FOR HOT AIR DRYER UNIT IN THE ELECTROLYTE CLEANING LINE

Special Topics on Residential HVAC

Innovative Technologies [and Design Concepts] in Commercial Foodservice

Condensation in Glazed Flat Plate Solar Collectors Timothy Anderson 1

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Bench Top Production Hydroponic Production

Enhance Facility Energy Management at Naval Expeditionary Base Camp Lemonnier, Djibouti. 12 May 2011

The perfect duo. ROTEX thermal store ROTEX solar system

Analysis of System Reports of Task 26 for Sensitivity of Parameters

The quest for acid-tolerant lucerne

Heritage Park Irrigation System Inspection Review of Water Use Estimated Water Budget Potential for Savings

CROWN YEARLY PROPERTY SCHEDULE

Heat recovery. Heat recovery. Gas heating 280 up to 54,000 /year. Oil heating 284 up to 54,761 /year. Electrical power consumption

Condensing technology

Designing and Operating an Energy Efficient Foodservice Facility March 12, 2014 Winnipeg, MB

Produced by the Residential Solution Sales Division. Daikin AC Americas, Inc.

User manual NIBE F2026

Energy & Water Savings in Commercial Food Service

BOA-Systronic. KSB Know-how, Volume 2

Air System Sizing Summary for AHU/CU-1 Project Name: Wilton Manors Fire Station#16 06/26/2016 Prepared by: L.N.I.

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

WLAC Facilities Committee Meeting. May 15, 2017

INSTRUCTIONS MANUAL FOR MED75HD - UPRIGHT GLASS DOOR FRIDGE

Regional Open Space Conservation Plan. Regional Staff Committee January 18, 2018

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

New Westminster Downtown Parking Strategy Public Open House #1 September 13, 2012

Orange Solar Pump HD50

FOOD PREMISES INSPECTION REPORT for Non-Compliant Critical / Non-Critical Items. Extreme Pita 48 Kenmount Road, St. John's, NL.

SEASONAL CROP COEFFICIENT OF GERBERA SOILLESS CULTURE

Transfer Station Recycling Update SWANA Technical Session-Waste Diversion 4 2/24/2017 2/28/2017

KELLYVILLE LIONS CALENDAR 2016 to 2017

Transcription:

Sivu 1/8 Design of a heat pump heating system with Aquarea Designer Project: Suomi 1 Date: Created by:?, (no data provided), (no data provided) Phone: (no data provided) Email: (no data provided) Building data Address Esimerkki Location Tampere 33xxx (FIN) (from database) Building area 120 m 2 Standard heating requirement 6.0 kw Internal gains 3600 kwh/year Solar gains (windows) 0 kwh/year Indoor design temperature 21 C Outdoor temp. limit for heating 'on' 15 C Underfloor heating by -- % Heat distribution Radiator heating by 100 % Wall heating by -- % Max. flow water temperature 45 C Max. return water temperature 40 C Solar collector area -- m 2 Service hot water Type of service Hot water with heat pump Tank volume 300 Litre Average daily need 150 Litre Cold water inlet temperature 10 C Target tank temperature 50 C Exchange loss 5 K Electrical auxiliary heating necessary yes

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5-19 o'clock 11.5 Ct/kWh Nighttime rate of heat pump Time for nighttime rate 19-5 o'clock 11.5 Ct/kWh Heat circulation pump(s) like heat pump: yes -- Ct/kWh Heating element for monoenergetic operation like heat pump: yes -- Ct/kWh Heating element for post heating of hot water like heat pump: yes -- Ct/kWh Climatic data Climatic location Tampere 33xxx (FIN) (from database) Monthly average temperatures in C Jan -7.5 Jul 16.0 Feb -7.3 Aug 13.9 Mar -3.2 Sep 9.4 Apr 2.6 Oct 4.5 May 9.5 Nov -0.4 Jun 14.2 Dec -5.2 Used Panasonic heat pump Description Sanitary tank Heat pump type Wattage at 2/35 WH-SXF12D9E8 Nordic Tank 300L air / water heat: 12.0 kw, electric: 3.5 kw Recommended flow-through of air 4800.0 m 3 /h Max. flow temperature 55 C Mode of operation bivalent (parallel) Design/Bivalent temperature -20 C Number of heat pumps used 1 Wattage of fan (included in heat pump performance 60 W data: yes) Wattage of heat circulation pump(s) 50 W

Sivu 3/8 Calculation results Monthly heat consumption Total heat consumption Heat consumption supplied Space heating in kwh Service hot water in kwh by heat pump 13154 2488 by second heat source 570 34 Power consumption By heat pump for space heating for service hot water 4097 kwh/year 849 kwh/year By Oil heating (additional power for non-monovalent mode of operation) for space heating 570 kwh/year for service hot water 34 kwh/year By auxiliary components Fan (included in heat pump performance data: yes) Heat circulation pump(s) 78 kwh/year 264 kwh/year Operating time of heat pump for space heating for service hot water 1089 h/year 206 h/year Heat withdrawal from heat source for space heating for service hot water 9220 kwh/year 1674 kwh/year

Sivu 4/8 Annual energy costs Caused by heat producers Caused by heat consumers Total Heat pump 598 Oil heating 79 Space heating 538 Service hot water 109 Heat circulation pump(s) 30 677 Annual C.O.P. 3.2 (auxiliary power included: )

Sivu 5/8 Operational costs Type of heating Price in Ct/kWh Efficiency [%] Additional costs in Total costs in /year /year Heat pump 315 992 Oil 11.5 88 265 2439 Gas 10.0 90 350 2207 Electric night storage heater 10.5 100 100 1805 Electric heating element 11.5 100 0 1868 wood heating 5.0 80 343 1410

Sivu 6/8 Investment costs Reference period: 20 years Rate of interest: 6.0 % Type of heating Sum of investment Operational costs in Investment costs in Total costs in costs in /year /year /year Heat pump 7750 992 674 1666 Oil 4000 2439 319 2758 Gas 3700 2207 276 2483 Electric night storage heater 1500 1805 130 1935 Electric heating element 500 1868 43 1911 wood heating 21500 1410 1845 3255

Sivu 7/8 Energy coverage Comparison of CO2-Emissions

Sivu 8/8 This calculation is based on user values and valid for normal meteorological conditions. The correct adjustment of the heat pump heating system is assumed. This calculation cannot guarantee that the calculated values are fulfilled in practical operation.