Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

Similar documents
Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

CCTV Portfolio. Phoenix Explosion-proof Range

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

INSTRUCTION MANUAL (ATEX / IECEx)

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Approved by: Document no.: EGT

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Beamex. Calibration White Paper. Calibration in hazardous areas

[ TECHNOLOGY ] and does this definition affect a burner.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Beamex Calibration White Paper. Calibration in hazardous areas

Overview of Hazardous Locations as They Relate to Solenoid Valves

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

ATEX, NOMENCLATURE AND CODING

Dual certification! Air handling units for potentially explosive atmospheres

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ATEX, NOMENCLATURE AND CODING

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Guide for hazardous areas

Dräger Polytron 8310 IR Detection of flammable gases and vapour

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

manual addendum DELPHI Ex

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Dräger Polytron 8700 IR Detection of flammable gases and vapors

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Dräger Polytron 8700 IR Detection of flammable gases and vapors

UL HAZARDOUS LOCATIONS SERVICES

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

4) Intrinsic Safety Certification

INSTRUCTION & SERVICE MANUAL

Explosion-protected actuator Page 259 of 292

1. GENERAL TECHNICAL INFORMATION

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Drive systems for the chemical, oil and gas industry. Electric drives and systems

OPTIBAR DP 7060 Supplementary Instructions

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Explosion-protected network cameras Safety first

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Flameproof Manual Call Points Series MCP

S T R I T T & P R I E B E I N C.

standards: standards:

Hazardous Area Portable Fan Heater The Bulldog

OPTIWAVE X500 Supplementary Instructions

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Hazardous Area Portable Fan Heater The Bulldog

Desiccant. Breather Range

Implementation of ATEX Guidelines

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Motorola Professional Series Enhanced ATEX Portable Radios. October 2007

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

ATEX Safety Switches. More than safety.

Hazardous Area Portable Fan Heater The Bulldog

Explosion-proof Immersion Heater Type D-8660

Dräger PIR 3000 Detection of flammable gases and vapours

High bay LED lighting fixture

Intrinsically Safe Solutions

VSD AND SS DRIVING ATEX MOTORS February 2014

Sieger Apex. Flexibility that meets your requirements

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Hazardous Area Zirconia Oxygen Systems

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Electrical Installations Design, Selection, Erection and Inspection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Operating Instructions

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Description. Applications

Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry

DTS Light fittings for explosive atmospheres

BC9700 series High Power LED Explosion Proof Light

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Certification Supplement Manual

Transcription:

Phoenix Flameproof Pan & Tilt heads and Camera Housings for potentially explosive environments www.vanderbiltindustries.com

Video monitoring under extreme conditions Security Products from Vanderbilt is a world leader in the manufacture of flameproof housings and Pan & Tilt heads. These are typically used in petrochemical, industrial, aerospace, or offshore industries, on sites where there is a risk of explosion because volatile gases, vapours, mists or dusts are present. The Phoenix range is recognised and chosen internationally by customers who require the best engineered solution for security in hazardous areas.

Video products for potentially explosive environments 30 years of proven reliability Phoenix range of explosion-proof housings and Pan & Tilt heads have been used around the world for over 30 years. First launched in 1980, the range was chosen because of its engineering performance and reliability - the latest Phoenix range takes this performance even higher, and is now the replacement of choice for upgrades and system expansions. A wide range of applications Since its launch in 1980, the Phoenix range of Pan & Tilt heads and housings have been used in: Oil refineries Oil tankers Oil & gas rigs Pharmaceutical plants Petrochemical plants n n Chemical process Flameproof housings and Pan & Tilt heads are popular in CPI (Chemical Processing Industry) applications, like petrochemical or food and beverage processing plants, that are dealing with volatile vapours, flammable dusts (such as flour, sawdust), and solvent vapours. Safety and Security Persoel safety should always be the number one priority, whether it be lone workers on oil platforms, or processing staff in a chemical plant. The Phoenix Flameproof range ensures that process controls and security levels can be maintained in hazardous areas whilst protecting the workforce. Low ruing costs Phoenix products are available with a range of built-in telemetry receiver options which are compatible with all Siemens telemetry controllers. This eliminates the need and cost of additional ATEX - approved flameproof enclosures. Phoenix housings are available with sunshields and heaters, integral telemetry receivers and wipers. Phoenix housings are also available with a factory pre-build option of cameras/lenses (Baseefa requirement for IIC certification). International Standards Phoenix equipment is certified to meet the rigorous and exacting European ATEX Directive, and is certified by the internationally-recognised body: Baseefa Ltd. All Phoenix products also meet the relevant European standards for electrical and mechanical safety, as well as electromagnetic compatibility. These standards generally meet or exceed the requirements of most international certification bodies.

ATEX / IEC Marking - Certification Information Ex II 2 G D Ex II2GD Ex db IIB T6 Ex tb IIIC T85 C Db Ex II2GD Ex db IIC T6 Ex tb IIIC T85 C Db ATEX Specific Marking Group II: non mining applications Equipment Category 2 giving a level of protection to equipment intended to be used in areas in which explosive atmospheres caused by gases, vapours, mists or air / dust mixtures are likely to be present. This protection is afforded under both normal and fault conditions. G D: for use in gas/vapour/mist and dust environments EEx: for use in potentially explosive environments Ex db: flameproof, pressure-resistant enclosure according to BS EN 60079-1:2007 IIB: suitable for gas groups IIB & IIA eg ethylene and propane IIC: suitable for gas groups IIC,IIB & IIA eg hydrogen, acetylene, ethylene & propane Suitable for use in Zones 1 and 2 (Intermittent hazards which are present for up to 1,000 hours per aum) T85 C Temperature class. Based on an ambient temperature of 40 C, maximum surface temperature will not exceed 85 C Features and benefits n n Options for Gas Group IIB and IIC explosive environments Suitable for use in hazardous conductive dust conditions n n Each unit is individually pressure-tested Housings include thermostatically-controlled demister and sunshield ncost n effective wiper options n n Pre-build option available for camera and lens

Phoenix Explosion-proof selection guide MODEL FP50B FH07B-30 FH07B-40 FH07C-30 FH07C-40 FPHC-40 Pan & Tilt Housing Housing Housing Housing Camera Head FEATURES ATEX Approvals Ex II2GD Ex db IIB T6 Ex tb IIIC T85 C Db Ex II2GD Ex db IIC T6 Ex tb IIIC T85 C Db Load rating 40 kg 40 kg Mounting Side mount Side mount Presets Standard Standard Heater Standard Standard Standard Standard Sunshield Standard Standard Standard Standard Factory fitted wiper Option Option Option Option Option Factory fitted 10fn receiver Option Option Option Option Option Factory fitted 17fn receiver Option Option Option Option Option DIMENSIONS External - Length 448 mm 545 mm 675 mm 545 mm 675 mm 675 mm (Housing) 448 mm (Pan & Tilt) External - Width 167 mm 210 mm 210 mm 210 mm 210 mm 210 mm (Housing) 167 mm (Pan & Tilt) External - Height 286 mm 186 mm 186 mm 186 mm 186 mm 186 mm (Housing) 286 mm (Pan & Tilt) Internal - Length 290 mm 420 mm 290 mm 420 mm 420 mm Internal - Width 114 mm 114 mm 114 mm 114 mm 114 mm Internal - Height 94 mm 94 mm 94 mm 94 mm 94 mm Weight 19 kg 10 kg 11.8 kg 10 kg 11.8 kg 11.8 kg (Housing) 19 kg (Pan & Tilt) OTHER Environmental EN 60079 IP67 IP67 IP67 IP67 IP67 IP67 Power Options (230 VAC, 50Hz) (24 VAC, 50/60Hz) (110 VAC, 60Hz) FP50B FP50B/L FP50B/U FH07B-30 FH07B-30/L FH07B-30/U Recommended brackets FH07B-40 FH07B-40/L FH07B-40/U FH07C-30 FH07C-30/L FH07C-30/U FH07C-40 FH07C-40/L FH07C-40/U FPHC-40 FPHC-40/L FPHC-40/U Warranty 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years Factory Fit Options FH07W Wiper kit for FH07 housings, 230 VAC, 50Hz FH07W/L As above but 24 VAC 50/60Hz FH07W/U As above but 110 VAC 60Hz PHOENIX-CERT_3RD Factory Fit customer-supplied camera and lens plus ATEX equipment certification for FH07 housings (additional charge per housing) Telemetry receivers are available as an option. Please contact Customer Support for further details. Accessories FH07C-CG_Cable Gland _100kg Heavy Duty Bracket _40kg Bracket CAHA1040_40kg Swivel Mount Adaptor (Standard 4 PCD)

The information in this document contains general descriptions of technical options available, which may not always need to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Vanderbilt - 2015 EN Vanderbilt International GmbH Head Office Borsigstrasse 34 65205 Wiesbaden Germany Sales Office Siemensallee 84 76187 Karlsruhe, Germany Tel.: +49 721 958 8138 Fax: +49 721 958 8159 Vanderbilt International Ltd. Suite 7 Castlegate Business Park Caldicot South Wales NP26 5AD United Kingdom Tel.: +44 20 3630 0670 Fax: +44 20 3630 0699 Vanderbilt International AB Englundavägen 7 Box 1275 17124 Solna Sweden Tel.: +46 8 629 0300 Fax: +46 8 627 0096 www.vanderbiltindustries.com