TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

Similar documents
VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

FIRE PROTECTION FIRE DAMPERS ISONE+

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

Bevent Rasch BSKC6. - Fire /06/17

Smoke extraction duct of sheet steel

HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR

Light oil - kerosene burner

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

SECTION AIR DUCT ACCESSORIES

Fire dampers. For diverse applications

Light oil burners. One stage operation

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Intumescent Fire Dampers

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

IRBB Inert gas damper

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

Type EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET, ALSO FOR NATURAL SMOKE AND HEAT EXHAUST SYSTEMS

INSTALLATION INSTRUCTION BOOKLET FOR SMOKE DAMPERS

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

Fire-Resistant. Automatic Doors

Fire damper DESIGN GENERAL FIRE CELL DIVISION DISTRIBUTION OF RESPONSIBILITIES FIRE PROTECTION DOCUMENTATION HAGAB FIRE DAMPER DESIGN

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

FAN ENGINEERING. Sealing of Fan Housings

THE HOME OF REACTIVE PROTECTION SYSTEMS

Oil burners Brûleurs fioul Stookoliebranders

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Fire resistance testing of technical cabinets in accordance with EN

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

The Passive Fire Protection Handbook

Light oil / kerosene burner

SECTION AIR HANDLING UNIT

Edward K. Budnick Hughes Associates, Inc. Wheaton, Maryland, U.S.A SUMMARY. that is entrained or otherwise mixed into the mass.

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Bevent Rasch RABC-VAV. - Fire /03/2018

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

The Passive Fire Protection Handbook

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Ventilation Solutions Laundries. fantech

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

NKW. Heater series HEATERS

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Instructions for operation and maintenance

Guideline No.: C-02(201510) C-02 FIRE DOORS. Issued date: October 20,2015. China Classification Society

Parts Available from

2006 Upgrade Kit FPX Wood Fireplaces

ELECTRICAL FIRE STOPPING SOLUTIONS

Fire Protection. Fire-resistant Glass Range. Pilkington Pyrostop. Pilkington Pyrodur

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop. Pilkington Pyrodur

Residential Fans & Air Purifiers

Chilled Water DOAS Fan Powered Terminal Units

Technical instructions

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

Direct Vent System Required

C-01 FIRE DECKS AND BULKHEADS

VASKA C11. gas -fireplace installation guide

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

Circular Fire Damper Cartridge

InstrumentationTools.com

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

GASEOUS HYDROGEN SYSTEMS

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

FIRE RESISTANCE OF ROLLING STOCK ELEMENTS STANDARD AND SPECIAL CASE OF TUNNELS

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

Double Skin Casing Air Handling Units

Basic Fire Door Requirements

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

W - WR - WD. Technical information W- WR - WD. Gas-fired convection heaters with fan

Bevent Rasch. FIDs. - Fire /05/18

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Loss Prevention Standards

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Two (2) Side Rail Cable Tray

HE120, HE160 Humidifier Installation Kit

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

Smoke Sealing Solutions for Service Enclosures in Exit Routes

CO 2 Fire Extinguishing Systems

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Advance Release September 2009

IFE Level 3 Certificate in Passive Fire Protection

ISO 9001 TUV CERT CE

Instructions for the BASIC Air Handling System, Sizes General 1.1 Description of the System

Transcription:

Brandspjæld BFD-CS Rektangulært brandspjæld FIRE DAMPER Our Fire Damper (BFD-CS) with EN1366-2:1999 EIS120 certification and CE marklet. E Integrity: Integrity is the ability of a component of a fire damper to prevent the transmission of fire as a result of the passage of significant quantities of flames or hot gases from the fire to the unexposed side, thereby causing ignition either of the non-fire exposed surface or of any material adjacent to that surface. I Insulation: Insulation is the ability of a component of a fire damper to withstand fire exposure without the transmission of fire as a result of significant transfer of heat. S Smoke Leakage: Smoke leakage is the ability of a product to resist the passage of smoke under defined temperature and pressure conditions. 120 Value in minutes of EIS classification periods (120 minutes resistance) Fire damper is a part of fire wall. The primary function of fire damper is closing when the temperature inside air duct reaches to 72 C. Besides this on usual time periods. Fire damper should have thermal sensor. The ability of closing at 72 C of fire dampers is through the agency of thermal sensor. Motorized fire dampers can be also connected to smokesensitive fire detection systems in order to react earlier. Fire damper must be closed during fire. Until temperature inside air duct increases, the dampers can be closed or opened for various of purposes. But when the temperature reaches to 72 C fire damper must be closed and provide integrity of fire wall. Fire damper must be also closed in case of power failure. Spring and lock mechanism inside actuator are resistant to high temperature. After fire damper is closed, it is not allowed to be opened by remote intervention. 62

Fire Damper (BFD-CS) Standard Dimensions, Effective Area and Flow Rate Chart: Standard Dimensions Effective Area Recommended (WxH) (mm) (m 2 ) Maximum Flow Rate (m 3 /h) View from above View from side 63

Fire Damper (BFD-CS) Component (For Wall Installation) 1 1,50 mm galvanized frame 2 Special gasket (Providing tightness between wall and casing) 3 Intumescent gasket (Providing tightness) 4 1,50 mm galvanized frame 5 Fire damper with actuator (72 C thermal) 6 72 C thermal sensor 7 Ceramic gasket 8 Intumescent gasket (Providing tightness) 9 30 mm thick calcium silicate board 10 High temperature resistant silicon 64

Fire Damper (BFD-CS) Wall Installation Detail: Front View There should be no space between wall and fire damper and they should form a tight structure. Thermal sensor of actuator should be on the upper side as shown at the drawing above. Damper blade should be at the middle of the wall. Fire damper should be installed vertically to the wall. 65

Fire Damper (BFD-CS) Components (For Duct Installation): 1 1,50 mm galvanized frame 2 1,50 mm galvanized frame 3 Fire damper with actuator (72 C thermal) 4 72 C thermal sensor 5 Ceramic gasket 6 Intumescent gasket (Providing tightness) 7 30 mm thick calcium silicate board 8 High temperature resistant silicon Fire Damper (BFD-CS) Duct Installation Detail: Wall Duct Connection Duct Duct Connection Seramic based gasket and heat-resistant silicon must be used between damper and air duct. Air duct must be tightly connected to fire damper with M8 bolt+washer+nut from every corner of facing flanges. Also, fire damper and air duct must be connected to each other using flange clamps with equal spacing between 15-20 cm. Heat-resistant silicon must be used on every place on duct that may have leakage. 66

CERTIFICATE 67

68