EXH Series Explosionproof Electric Air Heaters

Similar documents
FX5 Series Explosion-Proof Electric Air Heaters

FE1 Explosion-Proof Electric Air Heaters

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Brasch Hazardous Location Unit Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters

CX1 ProVector Explosion-Proof Heaters

HLA Series Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater

CF1 ProVector Explosion-Proof Heaters

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Description. Applications

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Comfort. Description. Applications

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

LMV Series W Low Profile - Medium Base

EJB Custom-Built Control Panels

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

EVLPF Series Compact Fluorescent

Ultra-Safe EXP Unit Heater

Description. Applications

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

KUH. Horizontal Unit Heater. Applications. Description

N2MVF Series Compact Fluorescent

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

ULTRA-SAFE Explosion-proof Duct Heaters

Description. Construction

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

ULTRA-SAFE Explosion-proof Duct Heaters

Explosion-Proof Forced Air Unit Heater - XGB

Circulation Heaters Selection Guidelines

Explosion-Proof Forced Air Unit Heater - XGB

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

ELECTRIC UNIT HEATERS FOR STANDARD AND HAZARDOUS (CLASSIFIED) LOCATIONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

DMV Series W For Combustible Dusts

Overview of Hazardous Locations as They Relate to Solenoid Valves

Circulation Heaters Selection Guidelines

MAC N-407 Air-Cooled Chiller

Screw Plug Immersion Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

LUH HORIZONTAL FAN-FORCED UNIT HEATER

FX5 SD Series Electric Forced Air Heaters for Hazardous Locations

Tubular Industrial Process

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

MACH N-407 Heat Pump Air-Cooled Chiller

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Applications. Standard Materials

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Owner s Manual. Electric Forced Air Heaters for Hazardous Locations. This manual covers the installation, maintenance, repair and replacement parts.

Custom Duct Heaters. Special Applications

Industrial Air Heaters

( )

(770) wwww.southgateprocess.com

Thermal Devices, Inc. Mount Airy, Maryland USA

SECTION DOMESTIC WATER HEATERS

Table 500-3(d) Identification Numbers. Maximum Identification

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018


ASME Packaged Electric Water Heater

FE2 Series. Installation, Operation, & Maintenance Instructions. Electric Forced Air Heaters for Hazardous Locations. Model Coding

Chilled Water DOAS Fan Powered Terminal Units

Powers Controls ET 134 Low Temperature Detection Thermostat

Electric Unit Heaters

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Heavy Industrial/Marine MaxGard

MAC-120HE-03 Air-Cooled Chiller

Immersion Heaters. Screw Plug Immersion Heater

Type UB-2502A and UB-3002A Forced-Air Heater

Copy Right By: Thomas T.S. Wan

Easy Installation & Service

SECTION (15767) - UNIT HEATERS

Installation, Operation and. Maintenance Instructions

PANELBOARD PROTECTION ON A GLOBAL SCALE

SECTION STEAM CONDENSATE PUMPS

Product Catalog. Air and Space Heaters. Section C

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

SUBMITTAL SCHEDULE & DATA

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Transcription:

EXH Series Electric Air Heaters Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G NEMA 7CD, 9EFG EXH explosionproof electric heaters are used: In areas made hazardous by the presence of flammable gases and vapors, and combustible dusts For rugged locations including: oil refineries, petrochemical plants, rigs, pumping stations, turbine compressors, pulp and paper mills, coal mines, grain elevators, etc. In areas where flammable vapors or gases or highly combustible dusts may be present due to accidental or abnormal conditions For standby heat to prevent process heat loss, or for personnel comfort during maintenance/repair operations Split fan guard for easy access to fan Compact design makes handling during installation easy Evacuated cores heat up quickly with even heat distribution Larger models offer greater kilowatt range providing more economical means to heat large areas Permanently sealed cores improve reliability and make field servicing easier Control box provides easy access for installation and maintenance Class I, Division & 2, Groups C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G NEMA: 7CD, 9EFG UL Standard: 823 CSA Standard: C22.2 Nos. 25, 30, 46 Heater shown has optional built-in thermostat. Options: The following special options are available: Description Suffix Built-in disconnect switch... D Built-in pilot light... P 3-way switch... S Built-in thermostat... T Built-in HRC explosionproof thermostat... HRC Accessories: Basic mounting kit suitable for applications where the support arm can be bolted or welded directly to structural steel or concrete. Cat. # BMK-EXH5 (insert fan size: 2, 6 or 20) Wall mounting kit suitable for mounting on Z sections. Cat. # WMK-EXH5 (insert fan size: 2, 6 or 20) Hanging mounting kit simple and economical if adequate overhead structure exists. Requires " pipe, cut and threaded not supplied. Cat. # HMK-EXH5 Swivel hanging mount kit swivels 360. Requires " pipe, cut and threaded not supplied. Cat. # SHMK-EXH5 (insert fan size: 2, 6 or 20) Pipe mounting kit useful in buildings with insufficient strength to use other types of mounts. requires 3" pipe. Cat. # PMKEXH5 (insert fan size: 2, 6 or 20) Standard Materials and Finishes: Fan Aluminum blade; steel spider and hub with 5 /8 in. (5.875 mm.) bore Core Steel with integral aluminum fins, vacuum charged and hermetically sealed Heating Elements Three long life, low watt-density, high grade metal sheathed elements Heat Transfer Fluid Long life formulated ethylene glycol and water, freeze protected to 49 F ( 45 C) Cabinet Material 4 gauge (0.075 in.) (.90 mm) steel; epoxy coated with 5 stage pre-treatment including iron phosphate Conduit Material Heavy walled, 0.22 in (3. mm.) steel cadmium plated BMK Basic Mounting Kit SHMK Swivel Hanging Mounting Kit HMK Hanging Mounting Kit WMK Wall Mounting Kit PMK Pipe Mounting Kit 684 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

EXH Series Electric Air Heaters Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G NEMA 7CD, 9EFG Specifications: EXH52 EXH56 EXH520 Nominal kw 3 5 7.5 0 5 20 25 30 35 Maximum Altitude (ft.) 2,000 8,000 0,000 7,000 0,000 7,000 0,000 7,000 6,000 (m.) 3,658 2,438 3,048 2,34 3,048 2,34 3,048 2,34,829 Air Delivery @70 F (CFM) 500 500 850 850 750 750 3600 3600 3,950 @ 2 C (m 3 /hr) 850 850 444 444 2973 2973 66 66 6,7 Horizontal Throw (ft.) 5 5 30 30 40 40 70 70 70 (m.) 4.6 4.6 9. 9. 2.2 2.2 2.3 2.3 2.3 Max. Mounting Height (ft.) 7 7 0 0 0 0 20 20 20 (m.) 2. 2. 3.0 3.0 3.0 3.0 6. 6. 6. Motor Power (HP) (kw) 0.87 0.87 0.87 0.87 0.87 0.87 0.373 0.373 0.373 Fan Diameter (in.) 2 2 2 2 6 6 20 20 20 (mm.) 305 305 305 305 406 406 508 508 508 Net Weight (lbs.) 40 40 40 40 68 68 20 20 20 (kg.) 63.5 63.5 63.5 63.5 76.2 76.2 9.2 9.2 9.2 Shipping Weight (lbs.) 94 94 94 94 28 28 252 252 252 (kg.) 88 88 88 88 98.9 98.9 4.3 4.3 4.3 Motor Type. Thermally protected. Permanently lubricated ball bearings. 725 RPM. Fan Guard Heating Elements Temperature High-Limit Control Circuit Control Transformer Split design with close wiring spacing. /4 in. (6.3mm.) probe will not enter. Three long-life, low watt-density, high grade metal-sheathed elements. Automatic reset type, snap-action bimetal, open on temperature rise. Rated 00,000 cycles at 0 amps, handles 0.28 amps. 20 Volts, 0.28 ams, 5 VA. Multi-tap primary, 20V secondary, 50 VA. Contactor 60 or 00 amp. rated,000,000 cycles at maximum capacity, operating at not more than 84% full load. 20V, 5 VA fuse protected coil. Overpressure Protection Fusible alloy plug 70 psi (.7 MPa). Temperature Code Rating T3B 65 C (329 F) Class I & II. Temperature Limitations Operational; 49 F to 76 F ( 45 C to 80 C), short term to 248 F (20 C). Dimensions Dimension 2.5-0 kw 2.5-20 kw 20.9 - Dim. 35 kw Tolerance ± Dimensional tolerances ±/8" (3.2mm) unless otherwise specified. A B C D E F in. 8 7 /6 8 7 /6 8 7 /6 /8 mm 25 25 25 3 in. 8 3 /6 22 5 /6 26 /4 /8 mm 462 566 667 3 in. 27 3 35 3 /6 mm 686 787 889 4 in. 8 22 26 /8 mm 470 572 674 3 in. 9 7 /5 23 7 /6 27 7 /6 3 /8 mm 494 596 697 0 in. 7 9 2 3 /6 mm 444 495 554 8 5 /6 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 685

EXH Series Electric Air Heaters Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G NEMA 7CD, 9EFG Ordering Information: Nominal Maximum Total Temperature Rise Heat Output Wattage (kw) Voltage Phase Cat. # Current (Amperes) F C BTU/Hr. EXH52 EXH56 EXH520 3.0 208 EXH5-20860-030 4.4.2 6.2 0,250 3.0 208 3 EXH5-208360-030 8.3.2 6.2 0,250 3.0 240 EXH5-24060-030 2.5.2 6.2 0,250 3.0 240 3 EXH5-240360-030 7.2.2 6.2 0,250 3.0 480 EXH5-48060-030 6.3.2 6.2 0,250 3.0 480 3 EXH5-480360-030 3.6.2 6.2 0,250 3.0 600 3 EXH5-600360-030 2.9.2 6.2 0,250 5.0 208 EXH5-20860-050 24.0 8.6 0.3 7,00 5.0 208 3 EXH5-208360-050 3.9 8.6 0.3 7,00 5.0 240 EXH5-24060-050 20.8 8.6 0.3 7,00 5.0 240 3 EXH5-240360-050 2.0 8.6 0.3 7,00 5.0 480 EXH5-48060-050 0.4 8.6 0.3 7,00 5.0 480 3 EXH5-480360-050 6.0 8.6 0.3 7,00 5.0 600 3 EXH5-600360-050 4.8 8.6 0.3 7,00 7.5 208 EXH5-20860-075 36. 27.9 5.5 26,600 7.5 208 3 EXH5-208360-075 20.8 27.9 5.5 26,600 7.5 240 EXH5-24060-075 3.3 27.9 5.5 26,600 7.5 240 3 EXH5-240360-075 8.0 27.9 5.5 26,600 7.5 480 EXH5-48060-075 5.6 27.9 5.5 26,600 7.5 480 3 EXH5-480360-075 9.0 27.9 5.5 26,600 7.5 600 3 EXH5-600360-075 7.2 27.9 5.5 26,600 0.0 208 3 EXH5-208360-00 27.8 37.2 20.7 34,50 0.0 240 EXH5-24060-00* 4.7 37.2 20.7 34,50 0.0 240 3 EXH5-240360-00 24. 37.2 20.7 34,50 0.0 480 EXH5-48060-00 20.8 37.2 20.7 34,50 0.0 480 3 EXH5-480360-00 2.0 37.2 20.7 34,50 0.0 600 3 EXH5-600360-00 9.6 37.2 20.7 34,50 5.0 240 3 EXH5-240360-50 36. 27. 5. 5,200 5.0 480 EXH5-48060-50 3.3 27. 5. 5,200 5.0 480 3 EXH5-480360-50 8.0 27. 5. 5,200 5.0 600 3 EXH5-600360-50 4.4 27. 5. 5,200 20.0 480 EXH5-48060-200 4.7 36. 20. 68,300 20.0 480 3 EXH5-480360-200 24. 36. 20. 68,300 20.0 600 3 EXH5-600360-200 9.2 36. 20. 68,300 25.0 480 3 EXH5-480360-250 30. 45.2 25. 85,400 25.0 600 3 EXH5-600360-250 24. 45.2 25. 85,400 30.0 480 3 EXH5-480360-300 36. 26.4 4.6 02,360 30.0 600 3 EXH5-600360-300 28.9 26.4 4.6 02,360 35.0 480 3 EXH5-480360-350 42. 30.7 7. 9,450 35.0 600 3 EXH5-600360-350 33.7 30.7 7. 9,450 Catalog Number Example: * Not available with built-in disconnect switch (option D). 686 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

XC Series Electric Heaters NEC: Cl. I, Div. & 2, Groups B*, C & D IEC: Cl. I, Zones & 2, Group IIB & H2* NEMA: 7B*CD Single phase XC explosionproof electric heaters are used: In areas where flammable liquids, gases or vapors are present For rugged locations including: Petroleum refineries, gasoline storage and dispensing areas Wastewater treatment plants Areas that use flammable liquids for cleaning parts in dip tanks Petrochemical plants Paint spraying areas Aircraft hangars and fuel servicing areas Hydrogen fuel cell and battery storage facilities Natural gas plants In areas where flammable vapors or gases may be present due to accidental or abnormal conditions For standby heat to prevent process heat loss or for personnel comfort during maintenance/repair operations Standard Sloped-top cabinet prevents objects that restrict airflow from being set on top Corrosion-resistant design with no exposed copper or brass suitable for H2S environments High-velocity airflow heats up area faster with better heat distribution 4-gauge steel cabinet for rugged reliability Short cabinet lengths take up less wall and floor space Optional built-in thermostat (Class I, Division, Groups C & D, and Zone, Group IIB models) reduces field installation costs Incoloy 840 heating elements have longer life expectancy Radial-embossed aluminum plate fins warp less for better heat transfer Galvanized steel mounting brackets for quick installation NEC: Class I, Divisions & 2, Groups B*, C, D IEC: Class I, Zones & 2, Group IIB + H2* NEMA: 7B*CD UL Standard: 823 CSA Standard: C22.2 Nos. 25, 30, 46 Temperature Code: T2A 280 C (536 F) Standard Materials and Finishes: Heating elements resistance wire embedded in a magnesium oxide refractory and sheathed in an Incoloy 840 tube Finned tube assembly aluminum tube with radial-embossed aluminum plate fins Cabinet 4-gauge (0.075"/.90 mm) steel, green-gray epoxy powder-coated front and side panels, galvanized steel back panel Accessories and Options: Built-in thermostat for 20-, 208-, 240-, 277- or 480-volt applications (see ordering information on next page) Remotely mounted HRC85 explosionproof thermostat using Honeywell control for 45 F 85 F heating range (order separately) Specifications: Nominal kw.2.8 3.6 4.8 7.6 Shipping Weight (lbs.) 6.3 6.3 6.3 88.4 04.3 (kg) 27.8 27.8 27.8 40. 47.3 Enclosures Mounting Brackets Heating Elements Optional Built-In Thermostat Cabinet Material Temperature Code Rating Temperature Limitations Operational Storage NEMA Type 7. For dry indoor use only. Do not immerse in water. Do not store or use in areas exposed to rain or snow. Two 4-gauge galvanized steel brackets. Two Incoloy 840-sheathed elements. room thermostat with 0 settings. 4-gauge (0.075"/.90 mm) steel. Rear panel is galvanized. Front and side panels are baked green-gray epoxy powder coated with five-stage pre-treatment, including iron phosphate. T2A 280 C (536 F) 45 C to 40 C ( 49 F to 04 F) 45 C to 80 C ( 49 F to 76 F) *Hydrogen applications only apply to heaters without built-in thermostats. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 687

XC Series Electric Heaters NEC: Cl. I, Div. & 2, Groups B*, C & D IEC: Cl. I, Zones & 2, Group IIB & H2* NEMA: 7B*CD Ordering Information: Without built-in room thermostat Class I, Div. & 2, Groups B, C & D; Zones & 2, Group IIB + H2 Cat. # Wattage (kw) Output (BTU/Hr) Voltage (Volts) Current (Amps) XC A N0.2 4097 20 0.0 5 XC A2 N0.2 4097 208 5.8 5 XC A3 N0.2 4097 240 5.0 5 XC A4 N0.2 4097 480 2.5 5 XC A5 N0.2 4097 600 2.0 5 XC A6 N0.2 4097 277 4.3 5 XC B N0.8 646 20 5.0 20 XC B2 N0.8 646 208 8.7 5 XC B3 N0.8 646 240 7.5 5 XC B4 N0.8 646 480 3.8 5 XC B5 N0.8 646 600 3.0 5 XC B6 N0.8 646 277 6.5 5 XC C2 N0 3.6 2292 208 7.3 20 XC C3 N0 3.6 2292 240 5.0 20 XC C4 N0 3.6 2292 480 7.5 5 XC C5 N0 3.6 2292 600 6.0 5 XC C6 N0 3.6 2292 277 3.0 5 XC D2 N0 4.8 6389 208 23. 25 XC D3 N0 4.8 6389 240 20.0 25 XC D4 N0 4.8 6389 480 0.0 5 XC D5 N0 4.8 6389 600 8.0 5 XC D6 N0 4.8 6389 277 7.3 20 XC E2 N0 7.6 25950 208 36.5 40 XC E3 N0 7.6 25950 240 3.7 35 XC E4 N0 7.6 25950 480 5.8 20 XC E5 N0 7.6 25950 600 2.7 5 XC E6 N0 7.6 25950 277 27.4 30 Maximum Circuit Fuse (Amps)* *Or equivalent breaker as per National Electrical Code and Canadian Electrical Code With built-in room thermostat Class I, Div. & 2, Groups C & D; Zones & 2, Group IIB Cat. # Wattage (kw) Output (BTU/Hr) Voltage (Volts) Current (Amps) XC A B.2 4097 20 0.0 5 XC A2 B2.2 4097 208 5.8 5 XC A3 B3.2 4097 240 5.0 5 XC A4 B4.2 4097 480 2.5 5 XC A6 B6.2 4097 277 4.3 5 XC B B.8 646 20 5.0 20 XC B2 B2.8 646 208 8.7 5 XC B3 B3.8 646 240 7.5 5 XC B4 B4.8 646 480 3.8 5 XC B6 B6.8 646 277 6.5 5 XC C2 B2 3.6 2292 208 7.3 20 XC C3 B3 3.6 2292 240 5.0 20 XC C4 B4 3.6 2292 480 7.5 5 XC C6 B6 3.6 2292 277 3.0 5 XC D3 B3 4.8 6389 240 20.0 25 XC D4 B4 4.8 6389 480 0.0 5 XC D6 B6 4.8 6389 277 7.3 20 XC E4 B4 7.6 25950 480 5.8 20 Maximum Circuit Fuse (Amps)*. Remote-mounted explosionproof room thermostats are not suitable for Group B & IIC applications. Remote contactors are also required on all 600-volt heaters and heaters with a current draw greater than 22 amps (supplied and installed by others). 2. Remote mounted explosionproof room thermostats suitable for Group B, IIB + H2 applications are a special-order item. 3. Operation at lower than rated voltages will result in reduced kw output and amp draw. Actual Output (kw) = [(Supply Voltage) 2 (Rated Voltage) 2 ] x Rated Wattage (kw) Dimensions Heater kw Rating A Dimensions B Dimensions.2-3.6 37.0" (940mm) 3.34" (796mm) 4.8 55.25" (400mm) 49.45" (256mm) 7.6 65.25" (654mm) 59.49" (5mm) *Hydrogen applications only apply to heaters without built-in thermostats. 688 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

HRC Thermostats with Honeywell Control Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G Cl. III NEMA 7CD, 9EFG, 2 Raintight Wet Locations HRC thermostats with Honeywell control are used: For heavy duty line voltage thermostats to control fan coils, fans, motor starters, valves, contactors, and circulator motors in heating and/or cooling systems. If larger motors than listed are to be controlled, relays or magnetic motor starters must be interconnected between motors and thermostats In specific hazardous atmospheres such as encountered in oil refineries, chemical plants, paint and varnish manufacturing plants, certain hazardous metal finishing areas, coal processing locations, granaries and grain processing plants A heavy duty snap switch is mounted in the enclosure; the temperature sensitive element is mounted on the external surface of the cover and actuates the switch through a shaft and bearing mechanism An external knob permits temperature setting within calibrated range; the knob is removable to prevent unauthorized adjustment; room ambient is indicated on thermometer at front NEC/CEC: Class I, Division & 2, Groups C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G Class III NEMA/EEMAC: 7CD, 9EFG, 2 UL Standard: 203 CSA Standard: C22.2 No. 30 Electrical Rating Ranges: 20 / 240 VAC 50 / 60 hertz Full load current in amperes: 20 VAC 240 VAC Heating 0.2 6.5 Cooling 7.4 4.0 Ordering Information: Temperature Range Non-Adjustable Operating Differential (approx.) Cat. # 45 85 F F HRC85 Furnished with thermostat and thermometer. Dimensions* Standard Materials: Feraloy iron alloy Standard Finishes: Electrogalvanzed and aluminum acrylic paint Size Ranges: Hubs 3 /4" through-feed *Dimensions are approximate, not for construction purposes. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds 689

HRC Bimetal Thermostat Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G Cl. III HRC Bimetal Thermostats are used: To control heating only, cooling only or ventilation systems in demanding industrial environments In specific hazardous atmospheres such as encountered in oil refineries, chemical plants, paint and varnish manufacturing plants, coal processing locations, waste storage facilities, pulp and paper mills, granaries and grain processing plants or any other location where specific explosive gases or dusts are present Bimetal sensing element that is fast acting, reliable and unaffected by altitude Compact, lightweight design makes it easy to install No exposed copper or brass parts for excellent resistance to corrosion Feed-through design for easy installation Durable all aluminum exterior Available for heating only or heating or cooling/ventilation applications Ordering Information Hub Size Description Cat. # 3 /4 Single Pole, Single Throw (heating only) HRC 3 /4 Single Pole, Double Throw (heating or cooling/ventilation applications) HRC2 NEC/CEC: Class I, Division & 2, Groups C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G Class III UL Standard: 203 CSA Standard: C22.2 No. 30 Dimensions Standard Materials: Copper-free aluminum Standard Finishes: Natural Size Ranges: Conduit opening 3 /4" hub Electrical Ratings: 480 VAC max HP @ 20 VAC HP @ 250 VAC 22 amps Res. Temperature Range: 36 F to 82 F (2 C to 28 C) Temperature differential: 2.5 F (.5 C) 690 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

TCH Electric Clocks Factory-sealed Cl. I, Div. & 2, Groups C, D Cl. II, Div., Groups E, F, G Cl. III Type TCH electric clocks are used: In oil refinery control rooms, hospital operating rooms, chemical plants, grain handling and processing plants and other similar locations where specific hazardous atmospheres may exist Sheet steel case may be used where environmental conditions are not severe; electric motor and connections are contained in corrosion-resistant enclosure; dials are 3" in diameter; reset knob protrudes from bottom of case Disassembly for installation and maintenance is easily performed; the motor housing is factory-sealed, with no external seals required NEC: Class I, Division & 2, Groups C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G Class III UL Standard: 203 Standard Materials: Clock body and cover sheet steel Motor housing copper-free aluminum Ordering Information: Sheet Steel Case Enclosing Sheet Enclosure with Clock Metal Band Motor Hub Size Style Cat. # Cat. # 0 VAC 60 hertz Self-Starting Synchronous (3 Watts) Dimensions* " With Sheet Steel Case Surface Mount TCH2220 TCH202 Standard Finishes: Aluminum aluminum acrylic paint Sheet steel baked aluminum enamel Size Ranges: Hubs " through-feed Electrical Rating Ranges: 0VAC, 60 hertz Self-starting synchronous motor 3 watts Options: The following special options are available: Description Suffix Sheet metal band notched for conduit, can be supplied for enclosing gap between wall surface See and back of case listings *Dimensions are approximate, not for construction purposes. Cat. # a b c TCH2220 7 2 7 /8 3 7 /6 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 202 Cooper Crouse-Hinds 69

ETW Telephones Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. III Raintight Wet Locations ETW series telephones are used: For communication in areas which may be hazardous due to the presence of flammable gases or vapors, and/or combustible dusts In chemical plants, oil refineries, bulk loading stations, paint and varnish manufacturing plants, grain processing and similar industries Modern styled, pushbutton wall-mount unit is very rugged in design, suitable for the harshest industrial applications Large, easy to read keyboard allows gloves-on operation Cast copper-free aluminum housing, with baked on powder coat finish, is highly resistant to corrosive atmospheres s are tone or pulse compatible and offer superior audio clarity Handset cord features a pin-type connector for easy field replacement; handset circuit is intrinsically safe Up to ten units can be connected on one line NEC/CEC: Class I, Divisions & 2, Groups B, C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G UL Standard: 203, 698 CSA Standard: C22.2 No. 30 FCC Approved Standard Materials: Enclosure copper-free aluminum Handset high impact plastic Dimensions ETW40 Ordering Information: Description Cat. # Phone w/ handset ETW40 Replacement handset (0' cord) ETW ETW:30SC Replacement handset (20' cord) ETW ETW:30SC 20 Phone w/ headset ETW40 HS Phone push-to-talk handset ETW40 PB Replacement headset ETW:P7200 ringer ETR Standard Finishes: Enclosure baked powder paint (safety blue) Accessories: A standard volume explosionproof ringer (ETR) is available, see page 694 for listing. For locations with a high level of ambient noise, a louder ringer can be installed. An ESR bell or ETH horn may be used by installing an ETC relay between the telephone line switch and the bell or horn. The relay coil is energized by the ringing current and the relay contacts control a separate power source to the signal. Dimensions are approximate, not for construction purposes. 692 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds

Telephone Accessories Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G Cl. III Raintight Wet Locations ETC232 power relays are used with ESR bells and ETH, W2H or WH horns; the relay coil is energized by the telephone ringing circuit, and the relay contacts control the separate 5VAC, 60 hertz power source ETR external ringer for ETW40 telephone; for low ambient noise areas, ring tone level is similar to a general use telephone; includes a ring detect relay which is powered by the telephone line voltage, (maximum 90VAC) NEC/CEC: Class I, Division & 2, Groups B*, C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G Class III UL Standard: 203 CSA Standard: C22.2 No. 30 Power Relay Description Rating Relay for Horn Signal 0A 5VAC 60 hertz Hub Size Cat. # 3 /4" ETC232 Ringer Description Normal volume external ringer for ETW40 telephone Hub Size Cat. # 3 /4" ETR Standard Materials: Bodies copper-free aluminum Covers copper-free aluminum Standard Finishes: Aluminum baked epoxy powder paint *For use in Group B hazardous areas, seals must be installed within " of each conduit entrance. 694 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Cooper Crouse-Hinds