MODBUS RS485 TECHNICAL INSTRUCTIONS

Similar documents
MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

Manual for the integration in BMS/GTC

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

eco PREMIUM ENERGY RECOVERY UNIT» INSTALLATION AND MAINTENANCE MANUAL

Corrigo E Ventilation

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

SAVE VTC 200. Installation and Service. Document in original language A002

SAVE VSR 150/B. Installation and Service. Document in original language A001

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

eco TOP INSTALLATION AND MAINTENANCE MANUAL

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

N M AirControl AHU. Control manual

SAUTER flexotron 800 Ventilation application User Guide

SAVE VTR 500. Installation and Service. Document in original language A001

Climatix Basic reference addresses for eq Fläkt application v1.x

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

» WITH REGASORP ROTARY HEAT EXCHANGER

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

CASA. W5 Smart. Installation, commissioning and maintenance instructions. W5_d_EN-t

Installation and User Guide

Systemair UAB Linų st. 101, LT Ukmergė, LITHUANIA Phone: Fax:

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CHILLED BEAM CASSETTE IQ STAR LYRA

HEAT RECOVERY UNIT MINIMASTER RDKS INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Installation and Service

HOTEL CHILLED BEAM IQ STAR SILENCIA

Fresh Air Ventilation

Fresh Air Ventilation

CPD COOKER HOOD TECHNICAL DATA

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

SAVE VTR 250/B. User Manual. Document in original language A001

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

RS485 MODBUS Module 8AI

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

AHU Plus. DX Air Handling Units

Corrigo E. Second generation which contains all applications and languages

ggg Air Handling Unit RT 700/1000S-EC-RS INSTALLATION OPERATION & CONTROL PANEL MAINTENANCE & SERVICE

Carbon Monoxide Transmitter

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

recooler HP EQKR HEAT PUMP

Technician manual

MicroTech Rooftop/RMC

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

Air Shower TECHNICAL DATA

TopMaster Air Handling unit. Technical data

TopMaster Air Handling unit. Installation instructions

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

PRO greenair HP. Ventilation unit with heat recovery and integrated heat pump. Design, installation, and operation instructions

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Sauter flexotron 800 ventilation Manual

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Corrigo E - User Manual Ventilation

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Installation and user's manual TAC4 DG + Modbus RTU

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are.

TSEK VHR EC HEAT RECOVERY UNITS

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

FCCP 200: Fume-cupboard indicator and monitor

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

MAKING MODERN LIVING POSSIBLE. User Guide. Danfoss Air Units.

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

SAUTER flexotron800 V2 Ventilation V3.3. manual P P

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

HEAT RECOVERY UNIT VILLAMASTER RDAF INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

L SERIES UNITS 505,191M. 4/2006 Supersedes 504,908M

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

VEKA Integrated Control

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

FUNCTION MANUAL, INSTALLATION GOLD RX/PX/CX/SD Generation F. Applicable to Program Version 1.27 and newer versions

Pre-programmed room controller with communication

FIS SMART SENSOR U (Draft 1) June 25, 2001

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

CLEANROOM MONITOR CR3A Network - Installation Instructions

BACnet Points for Single Compressor Water-to- Air Heat Pumps With Hot Gas Reheat Utilizing the FX10 Controller

Database for CTS6000 MODBUS

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

GLOBAL PX/RX/LP. Operation and maintenance instructions GLOBAL RX GLOBAL PX GLOBAL LP FW GLOBAL PX FW GLOBAL RX TOP GLOBAL PX TOP FW

Transcription:

MODBUS RS485 TECHNICAL INSTRUCTIONS

2 Modbus RS485 - Technical instruction DESCRIPTION, CONNECTIONS, PRESENTATION, DECIMALS DESCRIPTION RS485 has two connections, A and B. Often there is also a protective earth, ground. RS485 units are connected A to A and B to B. You may have to shift A and B in order for Modbus to work. RS485 is so called half duplex communication: Communication can only go in one direction at a time; i. e. the master will first send an enquiry and will then listen for the reply. A and B are used for both transmission and reception. CONNECTION TO CONTROL BOARD A to terminal 70 B to terminal 69 Modbus RS485 A B GND Ground to terminal 68 See figure to the right. 1 N 70.69.68 67.66.65.64 Default settings for RS485 communication is: Com speed 19200 Parity None Data bits 8 Stop bits 1 2 L 3 N 4 L 5 N 6 L 7 N 8 L A USB 51 50 49 48 47 46 PRESENTATION 1 bit status are presented as 0=off and 1=on 1 bit alarm are presented as 0=Normal and 1=Alarm 16 bit real values are presented in their actual value. E.g. %, Pa, l/s B 27 28 37 38 DECIMALS When Modbus are using a 16 bit register to handle real values, a factor must be used to have decimals. All temperature values and set points have a factor 10 and must then be divided/multiplied with 10 in the Master device. FläktGroup DC-9458-GB 2017-12-20_R0 Specifications are subject to alteration without notice

Modbus RS485 - Technical instruction 3 PARAMETER LIST COILS Address R / R/W 1) Description Comment I/O Range Default Housing eco Premium eco Top VEKC 00013 R External timer 1 DI1 Yes/No 00014 R External timer 2 DI2 Yes/No 00020 R Pressure switch, supply filter 2) DI5 Yes/No 00022 R Pressure switch, extract filter 2) DI6 Yes/No 00025 R Cooker hood switch DI9 Yes/No 00033 R By-pass Damper DO5 Yes/No 00085 R Summer/Winter Mode 1=Summer 0=Winter 00094 R Fire alarm Alarm Yes/No 00095 R/W Sensor error supply temperature Alarm Yes/No 00096 R/W Sensor error out door temperature Alarm Yes/No 00097 R/W Sensor error extract/room temperature Alarm Yes/No 00098 R Sensor error frost protection Post heater. Alarm Yes/No 00099 R/W Sensor error defrost temperature Alarm Yes/No 00105 R/W Dirty filter Alarm Yes/No 00106 R/W Supply fan error Alarm Yes/No 3) 00107 R/W Extract fan error Alarm Yes/No 3) 00110 R/W Frost alarm Plate heat exchanger Alarm Yes/No 00111 R/W Rotary heat exchanger failure Alarm Yes/No 00112 R/W Filter alarm, supply air 2) Alarm Yes/No 00113 R/W Filter alarm, extract air 2) Alarm Yes/No 00114 R/W Over heating electrical heater Alarm Yes/No 00115 R Pump/ heater malfunction Alarm Yes/No 00116 R Freezing hot water battery Alarm Yes/No 00117 R/W Summary alarm cooler Alarm Yes/No 00118 R/W Pump/cooling malfunction Alarm Yes/No 00182 R/W Acknowledge all Alarm 00184 R/W Temperature alarm Alarm Yes/No 00214 R Humidity control running Yes/No 1) R = Read only, R/W = Read/Write 2) Accessory 3) Only when COP/CAV FläktGroup DC-9458-GB 2017-12-20_R0 Specifications are subject to alteration without notice

4 Modbus RS485 - Technical instruction PARAMETER LIST HOLDING REGISTER Address R / R/W 1) Description Comment I/O Range Default Housing eco Premium eco Top VEKC 40025 R Supply air Temperature AI1 40,0 - +100,0 C 40026 R Out door air Temperature AI2 40,0 - +100,0 C 40027 R Extract/room air Temperature AI3 40,0 - +100,0 C Freezing protection post 40028 R Temperature AI4 40,0 - +100,0 C heater 40030 R Defrost air Temperature AI5 40,0 - +100,0 C 40032 R CO 2 Air quality AI6 0-2000 ppm 40035 R Humidity 1 Supply AI9 0-100 %rh 40036 R Humidity 2 Extract AI8 0-100 %rh 40037 R Pressure supply air 4) AI7 0-1000 Pa 40038 R Pressure extract air 4) AI8 0-1000 Pa 40039 R Airflow supply air 5) Calculated 0-10000 l/s 40040 R Airflow extract air 5) Calculated 0-10000 l/s 40041 R Fan speed, Supply air Signal AO1 0-100 % 40042 R Fan speed, Extract air Signal AO2 0-100 % 40043 R Post heating Signal AO3 0-100 % 40044 R Pre heating Signal AO4 0-100 % 40045 R Cooling 2) Signal AO5 0-100 % 40046 R Rotary heat exchanger Signal AO6 0-100 % 40049 R/W Set point Temperature 7,0-35,0 C 18 40054 R/W Min supply air temperature Temperature 15,0-35,0 C 15 40055 R/W Max supply air temperature Temperature 15,0-35,0 C 35 40073 R/W Set point CO 2 Air quality 0-2000 ppm 800 40078 R/W Supply fan speed trickle Speed low 30-100 % 30 40079 R/W Supply fan speed normal Speed normal 30-100 % 55 40080 R/W Supply fan speed boost Speed high 30-100 % 75 40081 R/W Supply fan speed cooker hood Speed 30-100 % 30 40082 R/W Supply fan speed fireplace Speed 30-100 % 100 40083 R/W Extract fan speed trickle Speed low 30-100 % 30 40084 R/W Extract fan speed normal Speed normal 30-100 % 55 40085 R/W Extract fan speed boost Speed high 30-100 % 75 40086 R/W Extract fan speed cooker hood Speed 30-100 % 100 40087 R/W Extract fan speed fireplace Speed 30-100 % 30 0 = Stop 1 = Auto 40213 R/W Main switch 0-3 2 = Manual 3 = Fire place 0 = Trickle/low 40202 R/W Fan speed 1 = Normal 0-2 2 = Boost/High 40094 R/W Setpoint air pressure 4) Supply air 0-2000 Pa 40101 R/W Setpoint air pressure 4) Exhaust air 0-2000 Pa 40095 R/W Setpoint airflow trickle 5) Supply air low 0-9999 l/s 40222 R/W Setpoint airflow normal 5) Supply air normal 0-9999 l/s 40223 R/W Setpoint airflow boost 5) Supply air high 0-9999 l/s 40102 R/W Setpoint airflow trickle 5) Exhaust air low 0-9999 l/s 40224 R/W Setpoint airflow normal 5) Exhaust air normal 0-9999 l/s 40225 R/W Setpoint airflow boost 5) Exhaust air high 0-9999 l/s 40275 R Active TemperatureSetpoint Temperature 0,5-50,5 C 40277 R/W Dirty filter alarm time 0 = Filter alarm disabled 0-600 days 180 1) R = Read only, R/W = Read/Write 2) Accessory 4) Only when COP, Constant Pressure Control 5) Only when CAV, Constant Air Volume Control FläktGroup DC-9458-GB 2017-12-20_R0 Specifications are subject to alteration without notice

FG_DC-9458-GB_Modbus RS485_TE_2017-12-20_R0_300dpi Copyright 2017 FläktGroup WWW.FLAKTGROUP.COM ECO PREMIUM FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. PRODUCT FUNCTIONS BY FLÄKTGROUP Air Treatment Air Movement Air Diffusion Air Distribution Air Filtration Air Management Air Conditioning & Heating Controls Service» Learn more on www.flaktgroup.com or contact one of our offices