ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Similar documents
ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

COMPLETE WATER TEMPERATURE CONTROL SYSTEM

NEW GENERATION HIGH LOW SYSTEMS

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

WATER TEMPERATURE CONTROL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

MEGATRON MODEL TA, TA-LF

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

CLASSIC HIGH LOW MANIFOLD SYSTEMS

INSTALLATION ADJUSTMENT SERVICE

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

TA-300, TA-300-LF, TA-350, TA-350-LF

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

TMV45 & TMV80 Standard Thermostatic Mixing Valves

HL45, HL80 Thermostatic High-Low Valves

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

EZ Plate Instantaneous

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

DigiTemp. Digital Water Tempering System. PVI.com

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Mixing Safety and Performance

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

Automatic Temperature Controller (ATC)

Wall Mounted Shower Systems

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

HOT INLET COLD INLET INSTALLATION

water source / fan coils

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

Installation S

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

Heat Transfer Packages

INDIRECT FIRED EQUIPMENT INSTALLATION FORM

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Installation S

Installation S

WALL MOUNTED SHOWER SYSTEMS

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

OUTLET LEONARDH THERMOSTATIC INSTALLATION

SECTION DOMESTIC WATER PIPING SPECIALTIES

Semi-Instantaneous Indirect Fired Water Heater

ADMS. AERCO Digital Mixing Station. AERCO.com

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Installation S

Installation S

GOLD Plus 30/40/60/80

SEQUENCE OF OPERATIONS

WALL MOUNTED SHOWER SYSTEMS

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

SECTION HUMIDITY CONTROL EQUIPMENT

Home. One Source For All Your Potable Water Needs

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Med Touch Combination Alarm Conversion Kits

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Sequence of operation

RQE Series Temperature Controllers

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

Transcription:

- 3 5 kg/cm C AS SE 7-3 5 THEMOSTATIC H - 3 5 3 5 - COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Submittal Data Sheet S-5Z-LF August, MEGATON LEAD FEE MODEL NB-LF HOT & COLD INLETS MIXED OUTLET ¼ ETUN PIPING. to GPM(3.7 to 5 l/min) Valve assembly is ASSE 7 Certified Valve assembly is certified to meet Low-Lead requirements of wetted surface area containing less than.5% lead by weight. All other fittings and components, the sum total of which comprise the wetted surface of this product, contain less than one quarter of one percent of lead by weight. See page for Specification detail See page 3 for Drawing detail See page for Flow capacity chart! WANING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer. For more information, go to www.p5warnings.ca.gov See page 5 for Options Engineer's Approval Job # Arch/Eng. Contractor Product is non-cancellable and non-returnable from date from order with factory. Signed submittal required with purchase order. Note: The models shown represent Leonard Products which are believed to be equivalent in type and function to items specified. Leonard Valve Company is not responsible for errors or omissions due to differences in interpretations of information provided. Leonard Valve Company Printed in USA 3 Elmwood Avenue, Cranston, I 9 USA Phone:.. Fax:.9.53 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com

EQUIED INFOMATION WHEN ODEING Circulator requirements must be specified by the Engineer, lines and are EQUIED, line 3 is optional. Circulated flow required, (not mixing valve flow). Head required without Megatron Assembly 3. Standard pump is TACO 3, if another manufacturer is preferred please specify, but note that ANY change from standard pump will result in a PICE INCEASE MEGATON MODEL NB-LF MEGATON MODEL NB-LF Complete Water Temperature Control Station (. - GPM, 3.7 to 5 l/min) to include: Wetted surface area of this product contains less than one quarter of one percent (.5%) of lead by weight Lead Free construction, to comply with LEAD FEE requirements bottom inlet connections (copper tube) top outlet connection (copper tube) ¼ return line size with piping method #5 Large thermostatic water mixing valve with DUA-trol solid bimetal thermostat (with Extended 7 Year Limited Warranty) directly linked to hot and cold valve porting, adjustable high temperature limit stop set for F (9 C)*, color-coded dial: C-H, locking temperature regulator, inlet angle strainer checkstops Full port ball valve, pressure gauge on mixed water outlet piping of large mixing valve. Small thermostatic water mixing valve with DUA-trol solid bimetal thermostat (with Extended 7 Year Limited Warranty) directly linked to hot and cold valve porting, adjustable high temperature limit stop set for F(9 C)*, color-coded dial: Cold-Hot, integral checkstops on inlets. Full port ball valve on outlet of small mixing valve Dial thermometer (range: to F,-to C) and pressure gauge on mixed water outlet of the system. Outlet Test Connection with ball valve and ¾ hose connection with cap Full port ball valve mounted downstream of test connection on mixed water outlet of the system Inlet piping manifold with full port ball valves and dial thermometers ( to F, -7 to C on hot supply, to F,-to C on cold supply) on hot and cold supply inlets eturn piping, ¼, with aquastat, circulator, dial thermometer ( to F,-to C), balancing valve (with positive shutoff) to balance system, and check valve Aquastat with temperature differential of 5 to 3 F(3to7 C) GFCI* switch. The GFCI switch will be used to turn the circulator on or off for setup. *Ground Fault Interrupter Bypass piping, ¼, with check valve and isolation ball valve Maximum operating pressure: 5 PSIG (KPA) System mounted on strut, galvanized. Strut shall be assembled with three hole flat angle plate on corners, four hole tee plates or two hole flat plate connectors on all other support pieces using 3/ grip lock nuts and 3/ x hex head cap screws, washers and lock washers. Factory pre-assembled and tested as a complete system All electrical connections to be completed by Electrical Contractor

- 3 LEO NAD 5 kg/cm ASSE 7-3 5 THEMOSTATIC - 3 5 3 LEO NAD 5 - MEGATON MODEL NB-LF " MIXED OUTLET " 9 7 -/" ETUN FOM BUILDING " 3 C H 3 " " HOT " COLD 5 5 -/" ETUN TO HOT WATE SOUCE Dimensions may vary with the addition of options see page #5 LEGEND. Full port ball valve. Large TM mixing valve 3. Small TM mixing valve. Test connection 5. Balancing Valve. Dial thermometer 7. Pressure gauge. Circulator-As specified by Engineer 9. Aquastat. Circulator power switch. Flapper check. Galvanized Strut 3. Tee bracket. Corner Bracket 5. Tee Drain 3

- 3 5 kg/cm ps i LEONA D C ASSE 7-3 5 THEMOSTATIC H - 3 5 3 LEO N AD 5 - MEGATON MODEL NB-LF (. TO GPM) Flow Capacity MINIMUM FLOW (GPM) (l/min).3 5 SYSTEM PESSUE DOP (PSIG) 5 5 3 35.7.97..7... 5 3. 5 3. PSI BA. 7 3 9 5 (3.7) 95 59 3 7 97 7 5 7 7 5 GPM l/min NOTE: Flowrates will vary depending on existing field conditions. Leonard Valve Company always recommends using CASPAK sizing software for proper valve sizing and model number applications. Note: The High Low model must be selected based upon the following: Maximum system demand for mixed water System pressure drop* Designer s estimated minimum mixed water flow requirement *System pressure drop= the pressure available at the inlet of the mixing valve unit minus the pressure required to operate the farthest fixture, i, e,. Shower valves, in the building. EQUIED PIPING METHOD #5 DOMESTIC TEMPEED WATE HIGH TEMP. WATE BALANCING VALVE HOT WATE SOUCE HEAT TAP COLD SUPPLY EXTENDED THEMOSTAT WAANTY Call the factory at --- for details on Leonard's exclusive Extended Limited Warranty for High Low System Thermostats. Note! Specifications are subject to change without notice.!!!!

LE ONA D kg/cm LE O NA D kg/cm LEONA D kg / cm LE ONA D LEON AD OPTIONS LC Megatron furnished without a circulator. FM Megatron with 3 legs, 3 ½ feet and 5 degree braces front and back for mounting to floor in center of room. FS Megatron with legs to floor to support the unit without hangers. CAB Megatron with SS cabinet around mixing valve PUMPS edundant recirculation pump PUMPS H High temperature loop recirculation pump HBP High temperature by-pass flush with locking ball valve OPTIONS * OPTIONS (shown on next page) * PIPING OPTIONS * LC Less circulator FM Floor mount FS Free standing CAB Cabinet around mixing valve PUMP - edundant recirculator pump PUMP H - High temperature loop recirculator pump HBP- High temperature by-pass flush AL Audio Visual Alarm DU emote Display Unit LMS--P Leonard Monitoring system LMS--P-BMS Leonard Monitoring system with module to connect to building management P ½ - ½ eturn line size (M5) P - eturn line size (M5) * Any option chosen will alter pricing Leonard Valve Company Printed in USA 5 3 Elmwood Avenue, Cranston, I 9 USA Phone:.. Fax:.9.53 Email: info@leonardvalve.com WEB: http://www.leonardvalve.com

OPTION AL: Leonard Single Probe Digital Temperature Alarm Primary Alarm Box includes: Single Point Temperature Probe - ange: -ºF to ºF esolution: ºF User adjustable high & low set points and initial alarm delay period Audible & visual alarms emote alarm contacts (SPDT) with adjustable relay delay period Min./Max. temperature values AL option replaces analog outlet dial thermometer with a single digital display OPTION DU: Leonard emote Display Unit emote Alarm Delay Option Includes: Activation by Primary Alarm s (pictured above) remote alarm contacts Alarm Delay Module with yellow, red, green LED indicators ecommended maximum distance from controller to DU is 5 OPTION LMS--P: Leonard Point Digital Monitoring System with Alarm Unit includes: Four () Temperature Probes - ange: -ºF to ºF esolution: ºF Audio & visual alarms User adjustable high & low temperature alarm set points Alarm delay period to prevent nuisance alarms emote alarm contacts (SPDT) with adjustable relay period / Ethernet Connection Web Server Interface for Setup & Commissioning Unit can send an E-mail transmission of alarms for up to contacts Unit can send an E-mail report daily with temperatures readings over the previous day LMS--P option replaces analog dial thermometers with a single digital display for all temperatures, incoming hot, incoming cold, outlet and return OPTION LMS--P-BMS: Leonard Point Digital Monitoring System with Alarm & Enhanced Protocol Communication Interface Module Primary Alarm Box includes: Four () Temperature Probes - ange: -ºF to ºF esolution: ºF User adjustable high & low set points and initial alarm delay period Audio & visual alarms emote alarm contacts (SPDT) with adjustable relay period ProtoNode Accessory Box includes: Interface Module to connect LMS--P-BMS to Building Management System (-BMS) Network, Complete Protocol Package Supported protocols include BACnet MS/TP, BACnet IP, Modbus TU, Modbus TCP/IP, SNMP, JC N, available simply by selecting the proper DIP switches Cat 5 Ethernet Cable not included LMS--P-BMS option replaces analog dial thermometers with a single digital display for all temperatures, incoming hot, incoming cold, outlet and return Leonard Valve Company Printed in USA 3 Elmwood Avenue, Cranston, I 9 USA Phone:.. Fax:.9.53 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com