ALARM OUTPUT MODULE. Product #7736

Similar documents
WeatherLink for Alarm Output Addendum

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

RAIN COLLECTOR HEATER

INSTALLATION INSTRUCTIONS

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus

Sensor Interface Module Installation/Operation Instructions

21-light Remote Annunciator. Owner s Manual

F AN-ASPIRATED RADIATION SHIELD

Manual & Technical Documentation V1.1

F AN-ASPIRATED RADIATION SHIELD

Dry Contact Probe DCP (#30008)

SYSTEM ENHANCEMENT MODULE

APP 721 MODBUS Mapping

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Independent Zone Control (I.Z.C.)

PTE0705 Electric Fence Monitor

PERMACONN PM1030 Includes DI300. Installation Manual

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

User manual. KNXgal. version

Code 542 Peltier Rack User's Guide

ANNUNCIATOR FIXED MODULE

IDP-Zone-6 Six Zone Interface Module

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Remote Chexit Module (RCM) System. General Information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

20 Light Remote Annunciator

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

TTSIM-1 Sensor Interface Module

CZ-6A Six Zone Interface Module

DE5300 Delayed Egress System. General Information

OVEN INDUSTRIES, INC.

Instruction Manual April sitrans AS 100

SC-6 Six Supervised Control Module

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

Integrated Sensor Suite with Fan-Aspirated Radiation Shield

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

CPS3200U Technical Support Guide

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

RS485 MODBUS Module 8AI

Pioneer-R16 Gas Monitor Operator s Manual

Quick Alert Remote (QA216R)

Model 3300 Technical Support and Installation Manual

MMF Six Zone Interface Module

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

PBI Manual. Paradox to KNX-BUS Interface

M2500 Engine Controller Installation Manual

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

PowerRouter application guideline

E340 BOILER CONTROL INSTALLATION MANUAL

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

GSM RFID VOICE Alarm System

Installation & Operating Instructions

Model 17A00 Expansion Enclosure

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

How to use the BTRM in Remote Enclosures

ELECTRONIC COMMUNICATING THERMOSTAT

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

HRX Technical Manual. Version 1.2

HEAT PUMP PROGRAMMABLE THERMOSTAT

780 Keypad Demonstrator Module

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

WatchDog Wireless Crop Monitor Operation Manual

Integrated Sensor Suite Installation Manual

Sierra Series 900 Single & Dual Channel System. Instruction Manual

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

INSTALLATION INSTRUCTIONS

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

USER MANUAL FOR OPERATING SYSTEM

GLOBAL. InstallatIon & operation manual

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

RC-2000 Thermostat Installation Instructions

Transcription:

ALARM OUTPUT MODULE The Alarm Output Module (AOM) enables you to use weather station alarms or commands from your computer to automatically start or stop external devices such as indicator lights, audio alarms, sprinkler controllers, relays, or other low-voltage AC or DC loads. The AOM works with the GroWeather, Energy EnviroMonitor, or the Heath EnviroMonitor. The GroWeatherLink and Energy WeatherLink also allow you to control two alarm outputs manually (by turning them on or off from the software), though the software is not required for basic operation. CAUTION: WHILE WE HAVE MADE EVERY EFFORT TO INSURE THAT THE ALARM OUTPUT MODULE WILL WORK RELIABLY, YOU SHOULDNOT USE IT IN SITUATIONS INVOLVING POTENTIAL PROPERTY LOSS OR HAZARDS TO HEALTH OR SAFETY OF PEOPLE OR LIVESTOCK. DAVIS INSTRUMENTS CANNOT BE HELD LIABLE FOR ANY FAILURE OF THE ALARM OUTPUT MODULE. Product #7736

COMPONENTS The AOM includes the following components. Please make sure you have all listed components before continuing. Alarm Output Module Alarm Output Module Cable, 2-foot (0.6 m) Power Y-Cable AC-Power Adapter Two Cable Ties Three #6 x 1 (25 mm long) Self-Threading Screws Four Adhesive Pads TOOL AND MATERIALS NEEDED You will need some of the following tools and materials. Relays You may need to obtain your own relays in order to switch equipment at voltages higher than 28 volts or power levels above 10 Watts or to provide time delays or other logic functions. Application notes discussing this further are available from Davis Instruments. Medium Phillips Screwdriver Small Slotted Screwdriver Page 2 Alarm Output Module

TYPICAL AOM INSTALLATIONS The AOM may be connected to either the sensor interface module or to the Interface Cable Adapter Module. The two illustrations below show typical AOM installations. AOM CONNECTED TO SENSOR INTERFACE MODULE AOM CONNECTED TO INTERFACE CABLE ADAPTER MODULE Typical AOM Installations Page 3

OPENING AND CLOSING THE ALARM OUTPUT MODULE Remove the cover by pushing down on the tabs at the top until you can remove the tabs from the slots. REMOVING THE COVER Reattach the cover as shown below. Make sure the tabs on top of the cover snap back into their slots, locking the cover in place REATTACHING THE COVER Page 4 Alarm Output Module

ALARM OUTPUT MODULE OPERATION The section below provides technical information on the operation of the Alarm Output Module. Installation instructions appear separately below. Circuit Operation AOM CIRCUIT DIAGRAM The Console sends to the Sensor Interface Module (SIM) a serial data word containing one bit for each alarm signal and user- and system-controlled output. From the SIM (or the Interface Cable Adapter Module) this is sent to the Alarm Output Module. The data are sent twice, once in true form and once inverted, and are shifted into the AOM s Input Register. When the Verify circuit confirms that the correct number of bits has been sent and that the two data sets match correctly, it generates a LOAD pulse to transfer the data into the Output Register. All 16 bits of this register are available at terminal strip J3 for selection as outputs. Four of the 16 are jumper-selected by the user to drive the photo-coupled outputs and appear as contact closures A, B, C, and D (closure indicated by lighted red LEDs). Setting the ENABLE switch off causes all contacts to open (the LEDs continue to indicate the state of the selected alarms). The LOAD command pulse is sent back to the Console, where quality of data transfer is determined and sent to the Link software. LOAD also flashes the yellow indicator to show that a good transfer has occurred. Two Set/Reset (RS) Flip-flops can be used to latch the four outputs. Latch 1 is SET by output A and RESET by B. Latch 2 is SET by output C and RESET by D. The Latch contents are available as output contact closures L1 and L2 (set ON = closed). The OK circuits check that a good transfer has occurred within the past 10 seconds or so, that the power voltage is good, and that the ENABLE switch is on. This validity check result is indicated by the green LED and is available as the OK output contact (OK = closed). Alarm Output Module Operation Page 5

Available Outputs The AOM provides four output contacts which may be selected from the conditions listed below. Each output (except time, daily ET, and the User outputs) remains active as longs as the alarm condition exists. The time and daily ET outputs remain active for one minute. The User outputs must be activated and deactivated by the user via the WeatherLink Software for that station. Also shown in the table below are the pin assignments for each of the three consoles. The Radio Power output is used to control switching of power to radio when in the power-conserving mode (see AOM Connections for Radio Power-Conserving Options on page 12). ALARM SIGNAL PIN ASSIGNMENTS (J3) ALARM OUTPUT J3 PIN GROWEATHER CONSOLE ENERGY EM CONSOLE HEALTH EM CONSOLE 16 Time Time Air Temp-Low 15 Daily ET Temp-Hum Index Air Temp-High 14 Dew Point Dew Point Inside Temp-Low 13 Radio Power Radio Power Inside Temp-High 12 Hum-Low Air Temp-Low Outside Hum-Low 11 Hum-High Air Temp-High Outside Hum-High 10 Air Temp-Low Hum-Low Inside Hum-Low 9 Air Temp-High Hum-High Inside Hum-High 8 Soil Temp-Low Wind Chill UV Dose 7 Soil Temp-High Wind Speed Outside Temp-Hum Index 6 User 1 User 1 Wind Speed 5 Temp-Hum Index Daily Rain Temp-Hum-Sun-Wind Index 4 Wind Chill Not Used Daily Rain 3 Wind Speed Not Used Inside Temp-Hum Index 2 User 2 User 2 Wind Chill 1 Daily Rain Barometer UV Index Contact Specifications The contact closure is provided by a photo-coupled MOS device. Because it is a solid-state device, it is not subject, as long as the load conditions are within specification, to arcing and contact-welding as are mechanical relays. The Control Output and Status contacts are rated as follows: Nominal Load Voltage: 28V AC or 48V DC, Maximum Peak Voltage: Load Current ON Resistance ±100 V, Maximum ±300 ma, Maximum at 77 F (25 C), derated to 150mA at 176 F (80 C) 4 Ohms, Maximum Page 6 Alarm Output Module

Basic AOM Information The AOM outputs are updated by the console at intervals of approximately 3 seconds. The data are sent twice and checked for agreement before being output, providing a measure of error detection. Note the following information concerning the jumpers, LEDs, switches, and jacks found on the AOM board: Normally-Open/Closed Jumper (J7) Jumper J7 enables the user to select whether the output contacts are normally-open or normally-closed. One jumper selects the mode for all four contacts. Yellow LED Indicator (LOAD) The yellow LED flashes briefly for each successful transfer of alarm data from the console to the output contacts (LOAD pulse). Green Status LED Indicator and Contact Output (OK) The green LED is lighted and the contact is closed to indicate that the following are true: Power is on at the AOM. A correct update has been made within the last 10 seconds. The enable switch is set to ON. Alarm Outputs (A, B, C, D) and Red LED Indicators The AOM has four alarm output contacts (A, B, C, D) to which you may connect external devices. Each output contact may be connected to a different alarm signal by connecting the jumper wire from the desired alarm output to the appropriate pin jack on jumper J3 (See Programming the AOM on page 9). The red LED indicators display the status of each of the four selected alarm signals. When the LED is lighted, the output is closed (if the ENABLE switch is set to ON). Alarm Output Module Operation Page 7

Latch Circuit Outputs (L1 and L2) and Red LED Indicators The AOM includes two latch circuits; each has one output contact and a red LED indicator. The latches are set and reset by selected alarms, enabling the user to set up two simple control circuits in which each output contact is set on by one alarm and set off by another. (For example, start a fan when the high temperature alarm becomes active and keep it running until the low temperature alarm becomes active.) The red LED indicators display the status of each of the latches. When the LED is lighted, the output is closed. If using latch circuits, jumper J7 must be placed in the NORMALLY- OPEN position. Latch Circuit L1 is set on (output CLOSED) by alarm output A and reset by alarm output B. Latch Circuit L2 is set on (output CLOSED) by alarm output C and reset by alarm output D. ENABLE switch (in the upper right corner of the AOM board) The ENABLE switch opens all outputs when set to OFF. The indicators continue to display the condition of the selected alarms or remote control lines. Power Connector (A2) To provide power to the AOM, you must connect the AOM power adapter to connector A2. AOM Cable Connector (A1) To enable the console to update the status of the AOM outputs, you must run the AOM Cable from connector A1 on the AOM to connector S6 on the sensor interface module (SIM) or the interface cable adapter module (ICAM). Alarm Signal Selection Panel (J3 and J5) The row of pin jacks at J3 enables you to program specific alarms for each of the four alarm outputs. Each of the numbered pin jacks at J3 is assigned to an alarm on the station (see Connecting alarm signals to alarm outputs on page 9 for a list of the pin assignments for each station). The four pin jacks next to the solid white rectangles provide locations to park unused jumper wires. Terminal J5 contains four jumper wires, one for each alarm output (A, B, C, D).To connect an alarm signal to one of the alarm outputs, insert the desired jumper wire from J5 in the appropriate pin jack on J3. Page 8 Alarm Output Module

AOM Cover Label The label on the cover of the AOM provides spaces in which you may write the name of the alarm condition connected to each output (A,B, C, D) and each latch circuit (L1, L2). You may also mark the appropriate check box to indicate whether the AOM is configured so the outputs are normally open or closed. OPERATION OF THE ALARM OUTPUT MODULE Operation of the AOM requires the following, each of which is described in a separate section below: Programming the AOM (page 9) Connecting the Outputs (page 11) Connecting the AOM to the System and Powering the AOM (page 12) Mounting the AOM (page 14) Programming the AOM Programming the AOM involves three main steps: connecting alarm signals to alarm outputs, selecting between normally-open and normally-closed operation, and setting the ENABLE switch. Connecting alarm signals to alarm outputs To connect an alarm to an alarm output, insert the desired jumper wire from J5 into the appropriate pin jack at J3. Use the table on page 9 to determine pin assignments. Once you make your alarm output pin assignments, you may find it useful to write them in the left-hand column of the table on page 9. Write the letter of the alarm output next to the number of the pin to which that output is assigned. CONNECTING ALARMS TO ALARM OUTPUTS Operation of the Alarm Output Module Page 9

Selecting between normally-open and normally closed operation If you select normally-open operation, each of the four alarm outputs will close when the alarm connected to that output is active. If you select normally-closed operation, each of the four alarm outputs will open when the alarm connected to that output is active. If using either of the two latch circuit outputs, you must select normally-open operation. To select normally-open operation, place the jumper plug over the two pins closest to the side labeled OPEN. To select normally-closed operation, place the jumper plug over the two pins closest to the side labeled CLOSED. SETTING JUMPER J7 Setting the ENABLE switch Make sure the ENABLE switch is set to the ON position. Otherwise, the outputs will remain open. ENABLE SWITCH (JUMPER WIRES NOT SHOWN) Page 10 Alarm Output Module

Connecting the Outputs The output devices are photo-coupled MOS transistors. They provide floating contacts suitable for low-voltage AC or DC loads, as specified in Contact Specifications on page 6. Each output contact is connected between the two like-colored terminals (A, B, etc.) of terminal block J4 (labelled CONTACTS). To make connection to the outputs install the two wires from the external circuit, one to each terminal of the pair, in J4. To place wires into the cage clamp, strip about 5/16 (8 mm) of the insulation off each wire in the cable. Use a small screwdriver to push down on the lever next to the cage clamp, insert the exposed wire into the opening created, and release the lever. When you release the lever, the wire(s) will be held in place by the cage clamp If the external load voltage is DC, insert the more-positive voltage wire in the + side of the terminal pair. INSTALLING WIRES When finished, gather all wires together and secure them to the cable tie lug using a cable tie. as shown below. When tightening the cable tie, make sure the wires are on top of the lug. SECURING WIRES Operation of the Alarm Output Module Page 11

AOM Connections for Radio Power-Conserving Options For power conservation when using a solar-battery-powered wireless Weather- Link, the AOM is used to switch radio power ON for only brief intervals. Make the connections for this case as follows: 1. Insert the jumper wire for output D (at J5) into pin jack 13 (at J3). 2. Connect the yellow wire from the Solar Power Kit to the D+ terminal (at jumper block J4). Connect the green wire to D-. 3. Strip approximately 5/16 (8 mm) of insulation from the yellow and green wires, and insert at B3 (To Switch) on the regulator circuit. (Consult the Solar Power Kit manual for more details.) Insert the yellow wire into the terminal labeled Yel. Insert the green wire into the terminal labeled Grn. 4. Strip approximately 5/16 (8 mm) of insulation from wires in the radio s power cable, and insert at B4 (Switched Power) on the regulator circuit. Insert the wire with the white stripe into the terminal labeled Wht. Insert the black wire (no stripe) into the terminal labeled Blk. Connecting the AOM to the System and Powering the AOM The AOM may be connected to either the sensor interface module (SIM) or the interface cable adapter module (ICAM), depending on your installation. (See Typical AOM Installations on page 3 for illustrations.)a 2 (0.6 m) AOM cable is provided to make this connection. You may also use a 40 (12 m) standard 6-conductor cable (available from Davis Instruments). The maximum cable length for this connection is 40 feet (12 m). 1. Using the label sheets provided with your station, attach one of the S6/ALARM/A1 labels onto each end of the AOM cable. Make sure the S6 end of the label is closer to one end of the cable and the A1 end of the label is closer to other end of the cable. 2. Attach the S6 end of the AOM cable to connector S6 on the SIM or the ICAM. 3. Attach the A1 end of the AOM cable to connector A1 on the AOM. 4. Attach one of the A2/ALARM POWER/P1 labels onto the end of the AC-power adapter cable or the power Y-cable, depending on which you are using (see Powering the AOM below). 5. Attach the jack at the end of your power source to connector A2 on the AOM. 6. Gather the AOM cable and the power cable together and secure them to the cable tie lug using a cable tie. When tightening the cable tie, make sure the cables are on top of the lug. Page 12 Alarm Output Module

Powering the AOM You may use a separate AC-power adapter for the AOM and the console, or you may use the power Y-cable as shown below to connect power to both the console and the AOM from a single adapter. USING THE POWER Y-CABLE Operation of the Alarm Output Module Page 13

Mounting the AOM You may mount the AOM against a wall or other vertical surface or you may simply set it down on a horizontal surface Note: Consult the appropriate shelter manual if installing the AOM in either the Complete System Shelter or the Multi-Purpose Shelter. To mount the AOM against a wall or other vertical surface, attach the base to the mounting surface using the #6 x 1 screws. Use two screws (as pictured below) when attaching to a stud. Use three screws (as pictured below) in any other case. Tighten the screws until the base is securely fastened to the mounting surface. Do not overtighten. ATTACHING THE BASE TO THE MOUNTING SURFACE If you plan to place the AOM on a horizontal surface, attach one of the adhesive pads to each of the four raised circles on the underside of the base. ATTACHING ADHESIVE PADS Page 14 Alarm Output Module

Operation of the Alarm Output Module Page 15

Product Numbers: 7736 Davis Instruments Part Number: 7395-085 Alarm Output Module Manual Rev. B Manual (7/7/99) This product complies with the essential protection requirements of the EC EMC Directive 89/336/EC. Davis Instruments Corp. 1996. All rights reserved.