Always there to help you. Register your product and get support at AC4373 AC4375. Question? Contact Philips.

Similar documents
User manual. Always there to help you. Question? Contact Philips AC3252 AC3254 AC3256

Register your product and get support at AC4002 AC4004. User manual

Register your product and get support at. AC4076. User manual

User manual 2017 Koninklijke Philips N.V. All rights reserved.

Register your product and get support at. AC4006. User manual

Register your product and get support at AC4091. User manual

Always there to help you Register your product and get support at AC4030/00 AC4030/10 Question? Contact Philips User manual

1. Important safety information

VK-6008D. User Manual

NANO HIPPO 50WH Air Purifier

AIR PURIFIER MODEL NO: APA240 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC1114

Note: Verify that plastic bags are removed from filters, if equipped or installed, before first use (see page 8) CONTENTS

Comefresh CF-8608 Air Purifier

Coway Air Purifier AP-1008DH

Contents. 7 Notices 21 Electromagnetic fields (EMF) 21 Recycling Important 4

Please read this manual carefully before use to ensure proper usage and save

Coway Air Purifier AP-1008BH/CH

WINIX AIR PURIFIER. User Manual. Tower XQ

HD9216 HD9217. User manual

THANK YOU FOR PURCHASING THE LV-PUR131 TRUE HEPA AIR PURIFIER BY LEVOIT. GET STYLE #LevoitLove #LevoitLifestyle

Contents. 1 Important 4 Power failure backup function 7 Electromagnetic fields (EMF) 7

THANK YOU FOR PURCHASING THE LV-H133 TOWER HEPA AIR PURIFIER BY LEVOIT! GET STYLE #LevoitLove #LevoitLifestyle

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

English. Important Read this user manual carefully before you use the appliance and save it for future reference.

Straightener. EN User manual. Register your product and get support at

HP8180

BestAir. Instruction manual

3 C D E 1 I A B F G H J K M L

BestAir. Instruction manual

Register your product and get support at HP4944 HP4945. EN User manual

Always here to help you. Register your product and get support at GC4400 series. User manual

FR EN NL DE ES PT IT TR RU UK

Series HD9720-HD9727

MeacoClean CA-HEPA 119x5 Air Purifier

Styler. Register your product and get support at HP4674. User manual

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

Hairdryer. Register your product and get support at HP8251 HP8250. User manual

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

AIR PURIFIER WITH GERMICIDAL UV LIGHT

Owner s Manual Super-Slim Four-Way Cassette

Operating Instructions Air Conditioner

Blueair C User Manual

Operating Instructions

User Manual Manual del usuario Guide d utilisation. Blueair 400 Series

Air Purification System. Instruction Book CLI-AP20

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

WINIX AIR CLEANER. User Manual HR950, HR951

HEPA Air Purifier with Ion Flow Technology

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

Blueair Pro User Manual

OPERATING INSTRUCTIONS

HD

KSD-35 DR11 KUE-35 DVN11

WHYNTER Eco Pure Air Purifier

Clock Radio AJ3122. Register your product and get support at User manual

OWNER S MANUAL. Air Purifiers ROOM AIR PURIFIER. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER

Series HD HD9741. User manual

Operating Instructions Air Conditioner

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

Mijia Air Purifier Pro

Reverse Cycle Split System Air Conditioner

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

ELECTRIC CONVECTOR HEATER. This product is only suitable for well insulated spaces or occasional use.

7. CARE AND MAINTENANCE

Triple Action Humidifier Model: AW600

EVAPORATIVE AIR COOLER

Register your product and get support at Hairdryer HP8260. User manual

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA


METAL CERAMIC FAN HEATER

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

AirInstinct Air Purifier

Convection Panel Heater

OPAL MINI. Instruction Manual

Blueair Classic. User Manual series

FU-Z31E AIR PURIFIER OPERATION MANUAL PETUNJUK PENGOPERASIAN AIR PURIFIER. No. Reg. : 03/DJ-ILMEA/MG/I/2000. Free standing type Tipe Berdiri

Operating Instructions Air Conditioner

Register your product and get support at AJ3500. User manual

AirPurifier LET S GET STARTED ACAMV101

USER MANUAL EAP120HC. Unit 2, The Nursery Berristow Lane South Normanton Derbyshire, DE55 2FX

instructions for use Air Purifier with ionizer _00/

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

MD2000 Dehumidifier with 2 litre Tank USER MANUAL

SAFETY INSTRUCTIONS. General Safety Instructions. Safety Instructions Operating Instructions Troubleshooting Tips Customer Service

Operating Instructions Air Conditioner

Instruction Leaflet AIR PURIFIER WITH AER1 TM TOTAL AIR FILTERS. pure indoor living. filter series MODEL: BAP9700-CN

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OVHM80 Max Air Purifier

PLUG-IN PERSONAL CERAMIC FAN HEATER

Welcome to a Healthy Home

TECHNICAL SPECIFICATIONS *

English 6 Dansk 14. Ελληνικα 31. Français 55 Italiano 63. Norsk 79 Português 86 HP4674

Transcription:

Always there to help you Register your product and get support at www.philips.com/welcome Question? Contact Philips AC4373 AC4375 User manual

Contents 1 Important 4 Safety 4 10 Notices 22 Electromagnetic fields (EMF) 22 Recycling 22 2 Your air purifier 6 Overview 6 3 Getting started 7 Install filters 7 Set up the Wi-Fi connection for the first time 8 Set up the Wi-Fi connection when the network has changed 9 4 Using the air purifier 10 Switch the air purifier on or off 10 Understand the air quality light 10 Set the sensitivity of the air quality sensor 11 Select the fan speed 11 Set the timer 12 Activate child lock 12 Night mode 12 Turn Wi-Fi on or off 13 Factory Reset 13 5 Cleaning your air purifier 13 Clean the air purifier 13 Clean the air quality sensor 13 6 Cleaning the pre-filter 14 7 Replacing the filters 16 Reset filter lock 18 8 Troubleshooting 19 9 Guarantee and service 21 Order parts or accessories 21 EN 3

1 Important Safety Read this user manual carefully before you use the appliance, and save it for future reference. Danger Do not let water or any other liquid or flammable detergent enter the appliance to avoid electric shock and/or a fire hazard. Do not clean the appliance with water, any other liquid, or a (flammable) detergent to avoid electric shock and/or a fire hazard. Warning Check if the voltage indicated on the bottom or indicated at the rear of the appliance corresponds to the local power voltage before you connect the appliance. If the power cord is damaged, you must have it replaced by Philips, a service center authorized by Philips, or similarly qualified persons in order to avoid a hazard. Do not use the appliance if the plug, the power cord, or the appliance itself is damaged. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not block the air inlet and outlet, e.g. by placing items on the air outlet or in front of the air inlet. Caution This appliance is not a substitute for proper ventilation, regular vacuum cleaning, or use of an extractor hood or fan while cooking. If the power socket used to power the appliance has poor connections, the plug of the appliance becomes hot. Make sure that you plug the appliance 4 EN

into a properly connected power socket. Always place and use the appliance on a dry, stable, level, and horizontal surface. Leave at least 20cm free space behind and on both sides of the appliance and leave at least 30cm free space above the appliance. Do not place anything on top of the appliance and do not sit on the appliance. Do not place the appliance directly below an air conditioner to prevent condensation from dripping onto the appliance. Make sure all filters are properly installed before you switch on the appliance. Only use the original Philips filters specially intended for this appliance. Do not use any other filters. Avoid knocking against the appliance (the air inlet and outlet in particular) with hard objects. Do not insert your fingers or objects into the air outlet. Do not use this appliance when you have used indoor smoketype insect repellents or in places with oily residues, burning incense, or chemical fumes. Do not use the appliance near gas appliances, heating devices or fireplaces. Always unplug the appliance after use and before you clean it. Do not use the appliance in a room with major temperature changes, as this may cause condensation inside the appliance. To prevent interference, place the appliance at least 2m away from electrical appliances that use airborne radio waves such as TVs, radios, and radio-controlled clocks. The appliance is only intended for household use under normal operating conditions. Do not use the appliance in wet surroundings or in surroundings with high ambient temperatures, such as the bathroom, toilet, or kitchen. The appliance does not remove carbon monoxide (CO) or radon (Rn). It cannot be used a a safety device in case of accidents with combustion processes and hazardous chemicals. EN 5

2 Your air purifier Congratulations on your purchase, and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips.com/welcome. Philips VitaShield IPS technology and NanoCloud technology ensures you Healthy air always. VitaShield IPS technology effectively removes pollutants (ultrafine particles, allergens, bacteria and viruses) with size >0.02 micron including bacteria and virus*. *According to 2008 Microbiological Risk Assessment Report of the World Health Organization (WHO), the avian influenza, human influenza viruses, Legionella, Hepatitus viruses and SARS coronavirus are larger than 0.02 micron. Read this user manual carefully before you install and use the air purifier. Save it for future reference. 6 EN

Overview a Touchscreen control panel b Light sensor c Air quality light d Air quality sensor e Filter 4: HEPA filter (AC4154) f Filter 3: Activated carbon filter (AC4153) g Filter 2: Multi-care filter (AC4151) h Filter 1: Pre-filter i Front panel a b c d e f g h i EN 7

3 Getting started Install filters The appliance comes with all filters fitted inside, but you have to remove the packaging of the filters before you can use the appliance. Remove all filters, unpack them, and place them back into the appliance as described below. 5 Remove all packaging material from the filters. Insert the filters in the correct order. 1 Place your fingers in the recesses of the side panels and gently pull the top part of the front panel towards you. 6 Put the HEPA filter, activated carbon filter and multi-care filter back into the purifier. 2 Lift the hooks at the bottom of the panel out of the bottom of the appliance. 3 To remove the pre-filter, push both locking clips down, and then pull the filter towards you. 4 Remove the filter by pulling on the numbered label. 8 EN

Make sure that the side with the tag is pointing towards you. 7 Place the pre-filter in the appliance. 1 2 Make sure that the side with the two locking clips is pointing towards you, and that all hooks are properly attached to the appliance. 8 To re-attach the front panel, insert the bottom hooks into the bottom of the appliance first (1). Then, push the panel against the body of the appliance (2). Set up the Wi-Fi connection for the first time This instruction is only valid when the air purifier is being set up for the first time, or if a factory reset has been performed. If the network has changed or the setup needs to be performed again, consult chapter Set up the Wi-Fi connection when the network has changed on page 9. You cannot set up two air purifiers at the same time. If you want to set up more than one air purifiers, you can only do it successively. Make sure that the distance between your mobile device and the air purifier is less than 10 meters without any obstructions. 1 Plug the air purifier into the power socket. 2 Press the button once, and the Wi- Fi indicator will slowly blink with an orange color. 3 Download the Philips Smart Air app by scanning the QR code or visit www.philips-smartairpurifier.com. 4 Have your network name and password ready for entry. EN 9

5 Launch the APP and follow the onscreen instructions to connect the air purifier to your home network. 6 When the purifier is connected to your mobile device, the Wi-Fi indicator will be continuously lit with the color orange. 7 After following all the onscreen instructions, the Wi-Fi indicator will have a white color when the connection to the home network is successful. If this is not the case, consult the troubleshooting section on page 19, or the help section in the APP for extensive and up-to-date troubleshooting tips. Set up the Wi-Fi connection when the network has changed 1 Make sure the air purifier is plugged into the power socket and switched on (when the appliance is switched on, one of the fan speed indicators is on). 2 Press the and buttons at the same time until you hear a chime (this takes about three seconds). The Wi-Fi indicator will slowly blink with an orange color. 3 Have your new network name and/or password ready for entry. 4 Launch the APP and select that you want to perform a new network setup. 5 Follow the onscreen instructions. 6 When the purifier is connected to your mobile device, the Wi-Fi indicator will be continuously lit with the color orange. 7 After following all the onscreen instructions, the Wi-Fi indicator will have a white color when the connection to the home network is successful. If this is not the case, consult the troubleshooting section on page 19, or the help section in the APP for extensive and up-to-date troubleshooting tips. 10 EN

4 Using the air purifier Make sure that Wi-Fi is switched on and connected to the internet on your mobile device when using the Philips Smart Air Purifier APP. Switch the air purifier on or off Do not press any button on the control panel within 5 seconds from plugging in the air purifier. 1 Put the plug of the air purifier into the power socket.»» The fan speed indicators (AUTO) and goes on. When the purifier is switched on, the air quality sensor will take some time to measure the air quality in the room. The air quality light changes its color and eventually stays in the correct color in accordance with the air quality. 3 Press and hold the button for 2 seconds to switch off the purifier. 2»» All lights go on from left to right in cycle, and you hear a chime. Then, the lights go out again.»» The air quality light shows its 4 colors. 2 Press the button to switch on the purifier. Alternatively, you can use the Smart Air APP to switch on the purifier. Tip The purifier has a memory mode. It will recall the previous settings of your last use. If you disconnect the purifier from the power supply after switching off, it will enter the default mode for next use. EN 11

Understand the air quality light Color of the air quality light Blue Dark purple Purple Red Air quality level Good Fair Unhealthy Very unhealthy The air quality light automatically goes on when the purifier is switched on. The built-in air quality sensor measures the air quality and automatically selects the appropriate color of the air quality light. When the air is clean, the color of the air quality light is in blue. When the air quality deteriorates, the color of the air quality light changes from dark purple to red. Consult the Air Quality Explained section in the APP for detailed description on how the air purifier works and how it cleans the air When it is set to a higher sensitivity, the purifier becomes more allergic to the pollutants in the air. When the purifier is in (AUTO) mode, it is more likely to choose a higher fan speed than the standard mode. 1 Unplug the air purifier from the power socket. 2 Wait for approximately 10 seconds, and then plug it back into the power socket. Set the sensitivity of the air quality sensor To meet different needs when you use the appliance, we are offering you the opportunity to adjust the sensitivity of the air quality sensor. There are 3 sensitivity levels: standard sensitive extra sensitive The pollution sensor is set to extra sensitive by default. You can adjust the sensitivity of the air quality sensor in the following way. 3 After the air purifier is plugged in, wait for a few seconds first. 4 Press the and buttons simultaneously until you hear one chime. 5 Press the button repeatedly to adjust the sensitivity level of the air quality sensor.»» One of the indicators (,, or ) goes on to show the preferred sensitivity level of the air quality sensor. 12 EN

Fan speed indicator Sensitivity level extra sensitive (default sensitivity) sensitive standard 6 When the desired sensitivity has been selected, press the and buttons simultaneously again, until you hear two chimes.»» The sensitivity setup has been finished. After you have changed the sensitivity, the purifier automatically starts operating at the set sensitivity level whenever you switch on the purifier. Select the fan speed You can select the desired fan speed. 1 Press the button once or more times to select the desired fan speed (,,,,, or ). When the set time has elapsed, the purifier automatically switches off. 1 Press the button to activate the timer.»» The timer indicator (,, or ) goes on. 2 Press the button repeatedly to choose the number of hours you want the purifier to operate. The corresponding indicator (,, or ) goes on. To deactivate the timer function, press the button repeatedly until the indicator (,, or ) is out. Tip You can use the Scheduler in the APP to set your air purifier as per your own preferences. Alternatively, you can use the Smart Air APP to set the timer. Set the timer With the timer function, you can let the purifier operate for a set number of hours. EN 13

Activate child lock You can activate the child lock function. 1 Press and hold the button for 3 seconds to activate the child lock function.»» The child lock indicator lights up. 3 2 Press and hold the button again for 3 seconds to deactivate the child lock function. 3 When the child lock function is activated, all buttons are locked except the button. There will be no audio feedback when you press the buttons. Tip Alternatively, you can use the Smart Air APP to activate the child lock function. Night mode The purifier works in harmony with its surroundings. The purifier automatically switches to night mode in 3 minutes when the room in which it is operating becomes dark. All the lights on the control panel slowly go out. You can touch any buttons on the control panel during this period, and the lights go back on. However, they will go out again in 5 seconds if the purifier is in night mode. If the room becomes bright again for 5 minutes or longer, the purifier resumes normal operation. Turn Wi-Fi on or off The Wi-Fi function of the air purifier is activated by default. If you do not wish to use the Wi-Fi function, you can choose to deactivate the Wi-Fi function in order to save energy. All other functions of the air purifier will continue to work. Follow below steps to switch Wi-Fi on or off. 1 Unplug the air purifier from the power socket. 2 Wait for approximately 10 seconds. 3 Plug the air purifier back into the power socket again. 4 After the air purifier is plugged in, wait for a few seconds first. 5 Within 30 seconds from plugging in the air purifier, press the and buttons simultaneously for 3 seconds.»» The Wi-Fi function will toggle on or off. 14 EN

You cannot operate the air purifier through the APP if you have deactivated the Wi-Fi function. To operate the air purifier through the APP you need to have the Wi-Fi function activated. When the Wi-Fi function is deactivated, the indoor data cache will not be stored. Factory Reset 1 Unplug the air purifier from the power socket. 2 Wait for approximately 10 seconds. 3 Plug the air purifier back into the power socket again. 4 After the air purifier is plugged in, wait for a few seconds first. 5 Within 30 seconds from plugging in the air purifier, press the and buttons at the same time for 3 seconds.»» The air purifier chimes once.»» The factory reset has been finished. EN 15

5 Cleaning your air purifier Tip Before moving the purifier, make sure to unplug the purifier first. You can use the concave of the air quality light as a handle to lift the purifier up. Always unplug the purifier before you clean it. Never immerse the purifier in water or any other liquid. Never use abrasive, aggressive, or flammable cleaning agents such as bleach or alcohol to clean any part of the purifier. Only the pre-filter is washable. Other air purifier filters are not washable nor vacuum cleanable. 2 Clean the air inlet and the air outlet with a soft dry cloth. Clean the air quality sensor Clean the air quality sensor every 2 months for optimal functioning of the purifier. Clean it more frequently if you use the purifier in a dusty environment. When the humidity level in the room is very high, it is possible that condensation develops on the air quality sensor. As a result, the air quality light may indicate that the air quality is bad even though it is good. In this case you have to clean the air quality sensor or use one of the manual speed settings. 1 Clean the air quality sensor inlet and the air quality sensor outlet with a soft brush. Clean the air purifier Regularly clean the inside and outside of the purifier body to prevent dust from collecting. 1 Wipe away dust with a soft dry cloth from the body of the purifier. 2 Remove the air quality sensor cover. 16 EN

3 Clean the air quality sensor, the dust inlet and the dust outlet with a lightly moistened cotton swab. 4 Dry them with a dry cotton swab. 5 Reattach the air quality sensor cover. EN 17

6 Cleaning the pre-filter 3 To remove the pre-filter, push both locking clips down, and then pull the filter towards you. The pre-filter is washable. Clean the pre-filter for every two weeks to ensure optimal functioning of the purifier. When the pre-filter needs cleaning, the goes on. Refer to the How to replace filters video clip in the Philips Smart Air Purifier APP. This video clip can be found in the filter status section. 4 Use a vacuum cleaner or wash the pre-filter under a running tap. If the pre-filter is very dirty, use a soft brush to brush away the dust. 1 Switch off the purifier and unplug it. 2 2 Place your fingers in the recess of the side panels and gently pull the top part of the front panel towards you. Then lift the hooks at the bottom of the panel out of the top of the purifier. 5 Air dry the pre-filter. 6 Put the pre-filter back into the purifier. Attach all hooks properly to the purifier. 2 1 18 EN

7 To reattach the front panel, insert the bottom hooks into the bottom of the purifier first (1). Then, push the panel against the body of the purifier (2). 8 Plug the air purifier into the power socket and press the button to switch on the purifier. 9 Press and hold the button for 3 seconds to reset the filter lifetime.»» The air purifier chimes once. Make sure that the pre-filter is completely dry. If it is still wet, bacteria may multiply in it and shorten the lifetime of the pre-filter. Make sure that the side with the two projections is pointing towards you, and that all hooks of the pre-filter are properly attached to the purifier. EN 19

7 Replacing the filters The indicator of the filter replacement indicates the respective filters (,, or )have to be replaced. Lifetime of the filter is based on the volume of air purified, it may differ from the way of using. In heavily polluted environment, the filter lifetime may be shorter than the recommended time. If you remove the front panel for filter changing while the purifier is switched on, all lights on the control panel will be off. Once the front panel is placed back to the purifier, it starts to run as its previous status. The replaceable filters are not washable nor vacuum cleanable. Replace the multi-care filter, the activated carbon filter, and the HEPA filter when the respective indicators (,, and ) go on. Insert the filters in the correct position. Make sure you place the filters in the order of HEPA filter, the activated carbon filter, the multi-care filter, and then pre-filter. Make sure that the side with the tag is pointing towards you. Refer to the How to replace filters video clip in the Philips Smart Air Purifier APP. The video clip can be found in the filter status section. 1 Switch off the purifier and unplug it. 2 2 Place your fingers in the recesses of the side panels and gently pull the front panel towards you. Then lift the panel off the hooks at the bottom of the purifier. This will last for approximately 2 weeks. On the last day of the 2 weeks, the purifier chimes every 30 minutes to inform you that the filter needs to be replaced. 20 EN

3 To remove the pre-filter, push both locking clips down, and then pull the filter towards you. Do not touch the pleated filter surface, or smell the filter as it has collected pollutants from the air. Wash your hands with tap water and soap after you have touched the used filter. 6 4 Remove the multi-care filter, activated carbon filter or HEPA filter using the tag on the filter. 5 Take the used filter by the two sides and deposit it gently into the household trash bin. 7 Remove all packaging material from the new filters that need replacement. Put the HEPA filter, activated carbon filter and multi-care filter back into the purifier. EN 21

8 Put the pre-filter back into the purifier. Reset filter lock 1 2 9 To reattach the front panel, insert the bottom hooks into the bottom of the purifier first (1). Then, push the panel against the body of the purifier (2). After 2 weeks of filter replacement alert, if the filters are still not replaced, the purifier will not work until the filter is replaced and the filter lock is reset. The goes on along with the filter replacement indicators (,,, and ). All indicators are off except if it has been activated.,, and buttons remain active, while and buttons are deactive. See Replacing the filters section to reset the filter lock. 10 Plug the air purifier into the power socket and press the button to switch on the purifier. 11 Press and hold the button for 3 seconds to reset the filter lifetime.»» The air purifier chimes once. 22

8 Troubleshooting This chapter summarizes the most common problems you could encounter with the purifier. If you are unable to solve the problem with the information below, contact the Consumer Care Center in your country. Problem The,,, indicators has been on continuously. No air comes out of the air outlet. The fan speed does not change when the mode is activated. The Wi-Fi setup is not successful I cannot operate the air purifier through remote control. The airflow that comes out of the air outlet is significantly weaker than before. Possible solution The filter is full. Replace the filter and reset the purifier. The purifier is not connected to the power supply. Plug the purifier into the power supply and switch on. In mode, the fan speed is set to a very low level. If you want to change the fan speed, press the button one or more times to set the desired fan speed. Check if the nework to which the purifier should connect is a 2.4 GHz network. 5 GHz networks are not supported. Check if the purifier is within range of the Wi-Fi router. You can try to locate the air purifier closer to the Wi-Fi router. Check if the network name is correct. The network name is case sensitive. Check if the Wi-Fi password is correct. The password is case sensitive. Retry the setup with the instructions in section Set up the Wi-Fi connection when the network has changed. The Wi-Fi connectivity can be interrupted by electromagnetic or other interferences. Keep the appliance away from other electronic devices that may cause interferences. Check if the mobile device is in airplane mode. Make sure to have the airplane mode deactivated when connecting to the Wi-Fi network. Consult the help section in the APP for extensive and upto-date troubleshooting tips Make sure the air purifier is connected to the local router and the local router is connected to the internet. The pre-filter is dirty. Clean the pre-filter (see Clean the pre-filter ). Please check if you have removed all the packaging material from the filters. 23

Problem The air quality does not improve, even though the purifier has been operating for a long time. The color of the air quality light always stays the same. I need cleaner air because I have an allergy. The purifier is extra loud. The purifier still indicates that I need to replace a filter, but I already did. The buttons do not work. Possible solution One of the filters has not been placed in the purifier. Make sure that all filters are properly installed in the following order, starting with the innermost filter: HEPA filter (4), activated carbon filter (3), multi-care filter (2) and pre-filter (1). The air quality sensor is wet. The humidity level in your room is high and causes condensation. Make sure that the air quality sensor is clean and dry (see Clean the air quality sensor ). The air quality sensor is dirty. Clean the air quality sensor (see Clean the air quality sensor ). You can change the air quality sensor sensitivity (see 'Set the sensitivity of the air quality sensor ) to make the purifier clean the air even better. Please check if you have removed all the packaging material from the filters. If the appliance is still too loud; you can change the fan speed to a lower fan speed level. Perhaps you did not press the button to reset the filter lock properly. Plug in the purifier, press the button and press and hold the button for 3 seconds. Check if the child lock function is activated. If so, press and hold the button again for 3 seconds to deactivate the child lock function. 24

9 Guarantee and service If you need information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Consumer Care Center in your country (you will find its phone number in the worldwide guarantee leaflet). If there is no Consumer Care Centre in your country, go to your local Philips dealer. Order parts or accessories If you have to replace a part or want to purchase an additional part, go to your Philips dealer or visit www.philips.com/ support. If you have problems obtaining the parts, please contact the Philips Consumer Care Center in your country (you will find its phone number in the worldwide guarantee leaflet). 25

10 Notices Recycling Electromagnetic fields (EMF) This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields. Compliance with EMF Koninklijke Philips N.V. manufactures and sells many products targeted at consumers, which, like any electronic apparatus, in general have the ability to emit and receive electromagnetic signals. One of Philips leading Business Principles is to take all necessary health and safety measures for our products, to comply with all applicable legal requirements and to stay well within the EMF standards applicable at the time of producing the products. Philips is committed to develop, produce and market products that cause no adverse health effects. Philips confirms that if its products are handled properly for their intended use, they are safe to use according to scientific evidence available today. Philips plays an active role in the development of international EMF and safety standards, enabling Philips to anticipate further developments in standardization for early integration in its products. Never dispose your product with other household waste. Please inform yourself about the local rules on the separate collection of electrical and electronic products. The correct disposal of your old product helps prevent potentially negative consequences on the environment and human health. 26

The information listed below is intended for the Wi-Fi module SN8205 that is installed in the air purifier. The logo based on "Measures for the Administration on Pollution Control of Electronic Information Products" and "Requirements for Logo" released on February 28th, 2006, is a logo for the environmental protection use period of electronic information products sold within China. It not only requires compliance for the precautions on the safety and use of this product. It is required that during one year from the day when it was made, the hazardous substances contained in a product will not leak or mutate, and result in any severe environmental pollution, any bodily injury or damage to any assets. In addition, the use period requirement is based on "Use Period of Technology" stated in "General Guidelines of Environment-Friendly Use Period of Electronic Information Products". : when the life of the products comes to an end, you must follow the regulations of electronic information products and recycling regulations of cities and provinces. Names and contents of toxic and hazardous substances or elements contained in products Environmental Protection Use Period Name of the Parts The entity SN8205 Wi-Fi Module Hazardous/toxic substances or elements Lead Mercury Cadmium Chromium PBB PBDE (Pb) (Hg) (Cd) (Cr6+) (PBB) (PBDE) X O O O O O O Indicates that the content of this toxic and hazardous substance contained in all of the homogeneous materials of this part is below the limit requirement in SJ/T11363-2006. X Indicates that the content of this toxic and hazardous substance contained in at least one of the homogeneous materials of this part is above the limit requirement in SJ/T11363-2006. 27

2014 Koninklijke Philips N.V.