Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Similar documents
FX5 Series Explosion-Proof Electric Air Heaters

FE1 Explosion-Proof Electric Air Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters

Brasch Hazardous Location Unit Heaters

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

FX5 SD Series Electric Forced Air Heaters for Hazardous Locations

EXH Series Explosionproof Electric Air Heaters

Ultra-Safe EXP Unit Heater

CF1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Owner s Manual. Electric Forced Air Heaters for Hazardous Locations. This manual covers the installation, maintenance, repair and replacement parts.

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

FE2 Series. Installation, Operation, & Maintenance Instructions. Electric Forced Air Heaters for Hazardous Locations. Model Coding

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

Description. Applications

Comfort. Description. Applications

Description. Applications

Shipboard Electric Water Heater

HLA Series Hazardous Location Fan Forced Unit Heater

ULTRA-SAFE Explosion-proof Duct Heaters

Shipboard Electric Water Heater

HLA Series Hazardous Location Fan Forced Unit Heater

ULTRA-SAFE Explosion-proof Duct Heaters


Electric Unit Heaters for Standard and Hazardous (Classified) Locations

INSTALLATION, PARTS, SERVICE AND MAINTENANCE MANUAL HEX5 series, electric unit heaters for hazardous locations

Shipboard Electric Water Heater

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Electric Unit Heaters

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

SUBMITTAL SCHEDULE & DATA

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Circulation Heaters Selection Guidelines

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

CXH-A Forced-Air Heater

ASME Packaged Electric Water Heater

Tubular Industrial Process

Centro-Matic Automated Lubrication Systems System Controls

Explosion Proof Hazardous Location Roof Top A/C Units

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

EVLPF Series Compact Fluorescent

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

VAC1 Series - Division 2 / Zone 2

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

VAC1 Series-Division 2 / Zone 2

MAC N-407 Air-Cooled Chiller

ELECTRIC UNIT HEATERS FOR STANDARD AND HAZARDOUS (CLASSIFIED) LOCATIONS

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

MACH N-407 Heat Pump Air-Cooled Chiller

Product Catalog. Air and Space Heaters. Section C

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.


TECHNICAL SPECIFICATIONS

Capacity: 1.5 to 6.0 Ton

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Indirect Fired Water Heater

Light Duty Commercial Electric Water Heater

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Circulation Heaters Selection Guidelines

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

CR1 Triton Series. Owner's Manual. Model Coding IMPORTANT INSTRUCTIONS - SAVE THESE INSTRUCTIONS. Corrosion-Resistant Washdown Unit Heaters

CWA4 Chilled & Hot Water Fan Coil

X Series (Model B) Explosion Proof Heater

Capacity: 1.5 to 6.0 Ton

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

RGE 13 A T - 1 A

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

Heat Pump Water Heater

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Description. Construction

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

KUH. Horizontal Unit Heater. Applications. Description

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

MAC-120HE-03 Air-Cooled Chiller

Transcription:

Stars Management JLT SUBMITTAL EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Tel: 00971 (04) 457 2383 Fax: 00971 (04) 457 2382 P.O. Box: 25867 Dubai U.A.E. E-mail: info@starsmanagementjlt.com Website: www.starsmanagementjlt.com Location: Unit No. 904, 1-Lake Plaza Plot No. PH2-T2 Jumeriah Lakes Towers, Dubai, United Arab Emirates Company is Registered & Licensed as FREE ZONE Company under the Rules & Regulations of DMCCA.

FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial applications, oil refineries, petrochemical plants, pulp and paper mills, grain elevators, hazardous waste storage facilities, wastewater treatment plants, etc., where specific explosive gases or dusts may be present. The FX5 offers a larger junction box for easier installation, additional limit controls and a heavy duty core. The heater core assembly is contained in a sturdy, epoxy-coated 14-gauge steel cabinet, which also carries the motor and fan assembly. Adjustable louvres allow directional control of the airflow. A narrow gap, two-piece fan guard is provided to shield all moving parts. All fasteners are zinc plated for corrosion protection. King heaters are built to last. All King products are subjected to exhaustive technical analysis and testing during design and development, and are manufactured under a registered quality assurance program. As a result, they have consistently proven their safety and reliability. For hazardous location heating, rely on the King FX5 heater for the most dependable, trouble-free service available. Suitable for the following hazardous location classifications: Class I, Divisions 1 & 2, Groups C & D Class II, Divisions 1 & 2, Groups E, F & G Class I, Zones 1 & 2, Groups IIA & IIB Temperature Code T3B 165 C (329 F) NEMA type 7 & 9 enclosures Built-in fuse protects contactor coil Spare fuse located in convenient holder Built-in load carrying contactor severe duty coil Convenient terminals for room thermostat connection Built-in control transformer Liquid-filled lower tank Printed circuit board 100 psig (690 kpa) pressure relief valve Automatic reset bimetal high-limit Copper bus bars Threaded explosionproof covers Core easily removable through bottom of heater cabinet Integral aluminumfinned steel heat exchanger tubes (optional Heresite coating available for corrosive environments) www.king-electric.com 1

Performance Data for 60 Hertz FX5 Temperature Code T3B 165 C (329 F) c UL us NOMINAL WATTAGE (kw) 3 5 7.5 10 15 20 25 30 35 MODEL VOLTAGE PHASE TOTAL CURRENT (A) OPTIONAL BUILT-IN DISCONNECT SWITCH AIR TEMPERATURE C RISE F FX5-208160-030 208 1 14.4 FX5-208360-030 208 3 8.3 FX5-240160-030 240 1 12.5 FX5-240360-030 240 3 7.2 6.2 11.2 10,250 FX5-480160-030 º 480 1 6.3 FX5-480360-030 480 3 3.6 FX5-600360-030 600 3 2.9 FX5-208160-050 208 1 24.0 FX5-208360-050 208 3 13.9 FX5-240160-050 240 1 20.8 FX5-240360-050 240 3 12.0 10.3 18.6 17,050 FX5-480160-050 º 480 1 10.4 FX5-480360-050 480 3 6.0 FX5-600360-050 600 3 4.8 FX5-208160-075 208 1 36.1 FX5-208360-075 208 3 20.8 FX5-240160-075 240 1 31.3 FX5-240360-075 240 3 18.0 15.5 27.9 25,600 FX5-480160-075 º 480 1 15.6 FX5-480360-075 480 3 9.0 FX5-600360-075 600 3 7.2 FX5-208160-100* 208 1 48.1 Not Available FX5-208360-100 208 3 27.8 FX5-240160-100 240 1 41.7 FX5-240360-100 240 3 24.1 20.6 37.2 34,100 FX5-480160-100 º 480 1 20.8 FX5-480360-100 480 3 12.0 FX5-600360-100 600 3 9.6 FX5-240160-150* 240 1 62.5 Not Available FX5-240360-150 240 3 36.1 FX5-480160-150 º 480 1 31.3 15.1 27.1 51,200 FX5-480360-150 480 3 18.0 FX5-600360-150 600 3 14.4 FX5-480160-200 º 480 1 41.7 FX5-480360-200 480 3 24.1 20.1 36.1 68,250 FX5-600360-200 600 3 19.2 FX5-480360-250 480 3 30.1 FX5-600360-250 600 3 24.1 12.2 22.0 85,300 FX5-480360-300 480 3 36.1 FX5-600360-300 600 3 28.9 14.6 26.4 102,350 FX5-480360-350 480 3 42.1 FX5-600360-350 600 3 33.7 17.1 30.7 119,450 Btu/hr WARRANTY: Under normal use the Company warrants to the purchaser that defects in material or workmanship will be repaired or replaced out charge for a period of 36 months from date of shipment. Any claim for warranty must be reported to the sales office where the product was purchased for authorized repair or replacement in the terms of this warranty. Note: (*) Exceeds the 48 amp. circuit limit of NEC 424-22 (º)480 1 Phase units are certified Class I, Div. 1, Group D and Class II, Div.1, Groups F and G. 1. Minimum conductor size for 30 C (86 F) ambient. Derate conductor for ambient temperature. Use minimum 90 C (194 F) insulation. 2. Heater is functioning normally if at rated voltage the amp draw is in 10% of the value in this table. 3. Operation at lower voltage will result in reduced heat output and amp draw. 4. Add T to model number when adding a built-in thermostat. 5. Add D to model number when adding a built-in disconnect switch. 6. Add P to model number when adding a built-in pilot light. 7. Add S to model number when adding a 3-way switch. 8. Add H to model number for units high off (deenergized) ambient temperatures. 9. Add C to model number for units Heresite coating.. 10. Add A to model number for units stainless-steel cabinet. ww w.king-electric.com 2

Performance Data for 50 Hertz FX5 Class I, Divisions 1 & 2, Groups C & D; Class II, Divisions 1 & 2, Groups E, F & G; Class I, Zones 1 & 2, Groups IIA & IIB. Temperature Code T3B 165 C (329 F) NOMINAL WATTAGE (kw) MODEL VOLTAGE PHASE TOTAL CURRENT (A) OPTIONAL BUILT-IN DISCONNECT SWITCH AIR TEMPERATURE RISE C F Btu/hr 2.5 FX5-220150-025 220 1 11.4 6.3 11.2 8,550 4.2 FX5-220150-042 220 1 19.1 10.5 19.0 14,350 6.3 FX5-220150-063 220 1 28.6 15.7 28.5 21,500 8.4 FX5-220150-084 220 1 38.2 21.1 37.8 28,700 12.6 FX5-220150-126* 220 1 57.3 Not Available 15.2 27.5 43,000 2.8 FX5-230150-028 230 1 12.20 7.0 12.5 9,550 4.6 FX5-230150-046 230 1 20.0 11.5 20.7 16,000 6.9 FX5-230150-069 230 1 30.0 17.2 31.1 23,550 13.8 FX5-230150-138* 230 1 59.9 Not Available 16.6 30.1 47,100 2.5 FX5-380350-025 380 3 3.8 6.3 11.2 8,550 4.2 FX5-380350-042 380 3 6.4 10.5 19.0 14,350 6.3 FX5-380350-063 380 3 9.6 15.7 28.5 21,500 8.4 FX5-380350-084 380 3 12.8 21.1 37.8 28,700 12.5 FX5-380350-125 380 3 19.0 15.1 27.2 42,700 20.9 FX5-380350-209 380 3 31.8 12.1 22.0 71,350 2.8 FX5-400350-028 400 3 4.0 7.0 12.5 9,550 4.6 FX5-400350-046 400 3 6.6 11.5 20.7 15,700 6.9 FX5-400350-069 400 3 10.0 17.2 31.1 23,550 9.3 FX5-400350-093 400 3 13.4 23.2 42.0 31,750 13.9 FX5-400350-139 400 3 20.1 16.7 30.2 74,450 18.5 FX5-400350-185 400 3 26.7 22.3 40.2 63,150 23.1 FX5-400350-231 400 3 33.3 13.5 24.2 78,850 3.7 FX5-415350-037 415 3 5.1 9.2 16.6 12,650 7.5 FX5-415350-075 415 3 10.4 18.7 33.8 25,600 14.9 FX5-415350-149 415 3 20.7 18.1 32.5 50,850 22.4 FX5-415350-224 415 3 31.2 13.1 23.5 76,450 4.2 FX5-440350-042 440 3 5.5 10.5 19.0 14,350 8.4 FX5-440350-084 440 3 11.0 21.1 37.8 28,700 16.8 FX5-440350-168 440 3 27.5 20.3 36.5 57,350 20.9 FX5-440350-209 440 3 27.5 12.2 22.1 71,350 Notes: 1. Minimum conductor size for 30 C (86 F) ambient. Derate conductor for ambient temperature use minimum 90 C (194 F) insulation. 2. Heater is functioning normally if at rated voltage the amp draw is in 10% of the value in this table. 3. Operation at lower voltage will result in reduced heat output and amp draw. 4. Add T to model number when adding a built-in thermostat. 5. Add D to model number when adding a built-in disconnect switch. 6. Add P to model number when adding a built-in pilot light. 7. Add S to model number when adding a 3-way switch. 8. Add H to model number for units high off (deenergized) ambient temperatures. 9. Add C to model number for units Heresite coating. 10. Add A to model number for units stainless-steel cabinet. Installation Conditions: 1. The FX5 Series Electric Air Heaters are for dry indoor use only. Do not immerse in water. Do not store or use in areas exposed to rain or snow. 2. The FX5 heaters are to be used only in atmospheres having an ignition temperature higher than 165 C (329 F). 3. Altitude restrictions apply - see specifications on next page. 4. Heaters should be connected to a fixed power supply and must be permanently mounted in a level, upright position during operation. 5. Read and be aware of the terms of our Warranty located in the owner s manual. 6. Refer to Owner s Manual. Note: (*) Exceeds the 48 amp. circuit limit of NEC 424-22. www.king-electric.com 3

Specifications for 60 Hertz FX5 60 HER T Z FX5 N OMI NA L kw 3 5 7.5 10 15 20 25 30 35 Maximum Altitude (ft) 12,000 8,000 10,000 7,000 10,000 7,000 10,000 7,000 6,000 (m) 3,658 2,438 3,048 2,134 3,048 2,134 3,048 2,134 1,829 Air Delivery @ 21 C (m 3 /hr) 1,444 2,973 6, 1 16 @ 70 F (CFM) 850 1,750 3,600 Horizontal Throw (ft) 30 40 70 (m) 9.1 12.2 21.3 Maximum Mounting Height (ft) 10 10 20 (to underside) (m) 3.0 3.0 6.1 Motor Power* (HP) 1/2 1/2 1/2 (kw) 0.373 0.373 0.373 Motor Speed (RPM) 1,725 1,725 1,725 Fan Diameter (in) 12 16 20 (mm) 305 406 508 Net W eight Shipping W eight out out out 140 152 168 180 201 213 63.5 68.9 76.2 81.6 91.2 96.6 194 206 218 230 252 264 88 93.4 98.9 104.3 114.3 119.7 See page 1 1 for general specifications common to all FX5 models. W eights are an approximate maximum. Manufacturer reserves the right to replace motors suitable alternates. Specifications for 50 Hertz FX5 50 HER T Z FX5 N OMI NA L kw 2.5 3.7 & 4.2 6.3 & 7.5 8.4 12.5 & 12.6 14.9 & 16.7 20.9 22.4 Maximum Altitude (ft) 12,000 8,000 10,000 7,000 10,000 7,000 10,000 7,000 (m) 3,658 2,438 3,048 2,134 3,048 2,134 3,048 2,134 Air Delivery @ 21 C (m 3 /hr) 1,189 2,463 5,096 @701 F (CFM) 700 1,450 3,000 Horizontal Throw (ft) 25 35 60 (m) 7.6 10.7 18.2 Maximum Mounting Height (ft) 10 10 20 (to underside) (m) 3.0 3.0 6.1 Motor Speed (RPM) 1,437 1,437 1,437 Motor Power* (HP) 1/4 1/4 1/2 (kw) 0.187 0.187 0.373 Fan Diameter (in) 12 16 20 (mm) 305 406 508 Net W eight out 140 152 168 180 201 213 63.5 68.9 76.2 81.6 91.2 96.6 Shipping W eight 194 206 218 230 252 264 88 93.4 98.9 104.3 114.3 119.7 See page 11 for general specifications common to all FX5 models. W eights are an approximate maximum. * Manufacturer reserves the right to replace motors suitable alternates. out out ww w.king-electric.com 4

Model Coding FX5-480 3 60-350 - W T, D, P, S, H, C, A MODEL SERIES 5th GENERATION HEATER VOLTAGE 208V 240V 480V 600V PHASE 1 3 HERTZ 50 60 Reminder: This nomenclature illustration is intended primarily to explain how a product part number is defined. Not all voltage and/or wattage combinations are available - please consult the Performance Data chart(s) for product availability. HEATER KILOWATTS WELDED CORE OPTIONS T - Built-in thermostat D - Built-in disconnect switch P - Built-in pilot light S - 3-way switch H - Unit high off (deenergized) ambient temperatures C - Heresite coating A - Stainless-steel cabinet www.king-electric.com 5

Approvals Hazardous Locations Classifications M otor T ype Fan Fan G uard M ounting Holes Heating Elements T emperature High-Limit Control Circuit O ptional Built-in T hermostat Control T ransformer Contactor Cabinet M aterial Core Conduit M aterial O verpressure Protection O perational T emperature Range Junction Box (H x W x D) Field Connection Weight (for 15 kw unit) Class I, Divisions 1 & 2, Groups C & D Class II, Divisions 1 & 2, Groups E,F & G Class I, Zones 1 & 2, Group IIA & IIB Temperature Code T3B 165ºC (329ºF) Explosion-proof. Thermally protected. Permanently lubricated ball bearings Aluminum blade. Steel spider and hub 5/8 (15 mm) bore Split design close wire spacing. 1/4 (6.3 mm) diameter probe will not enter Four 9/16 (14 mm) diameter holes at the top of heater Long-life metal-sheathed elements (Propylene Glycol) Automatic reset type, snap-action bimetal, open on temperature rise. Rated 100,000 cycles at 10 amp, handles 0.128 amps, plus an additional ambient high limit 120V, 0.128 amps, 15VA. (Grounded) Explosion-proof 2 C to 28 C (36ºF to 82ºF) Multiple voltage primary, 120V secondary, 25VA 40 or 75 amp. Rated for 500,000 mechanical operations. 120V, 15VA coil (separately fuse-protected) 14-gauge (0.075 / 1 mm) epoxy powder coated steel. Optional Heresite coating available for corrosive atmospheres an optional stainless-steel casing HD Core Heavy wall, 0.122 (3 mm), steel Preset 100 psig (690 kpa) pressure relief valve, aluminum body, no serviceable parts -20ºC to 40ºC (-4ºF to 104ºF) 10.25 (230 mm) x 8.00 (180 mm) x 9.12 (205 mm) Two 1 NPT 168 lbs (76.36 kgs) FX5 G eneral Specifications Weight disconnect (for 15 kw unit) 180 lbs (81.82 kgs) O ptional Built-in Disconnect Switch uses x-max construction O ptional Pilot Light O ptional 3-Way Switch Explosion-proof light fixture replaceable bulb Explosion-proof 3 position fan switch (on, off, fan only) www.king-electric.com 6