M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

Similar documents
FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Element D Services Electrical

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

SECTION ELECTRICAL GENERAL PROVISIONS

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

DONALD H. BERG, ARCHITECT

SECTION LOW VOLTAGE LIGHTING CONTROLS

Incorporate as part of the Contract Documents, the following:

IN2 Lighting Control Devices

Construction Management at Risk Services. New North East Branch Library Project. August 3, 2018

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

PART GENERAL 1.01 SECTION INCLUDES

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Allegany College of Maryland ACM Welcome Center M&D Project No

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

SECTION (16140) - WIRING DEVICES

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.

SECTION LIGHTING CONTROLS

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

A. This Section includes the following lighting control devices:

LIGHTING CONTROL DEVICES

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1

SECTION ISOLATED POWER SYSTEMS

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

SECTION LIGHTING CONTROL DEVICES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

SECTION AUTOMATIC TRANSFER SWITCHES

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

PANELBOARDS & BUILDING DISTRIBUTION

A. Shop Drawing submittals shall include, but not be limited to, the following:

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

Electrical Design Guidelines Table of Contents

Emery County Senior Center Green River 06/07

Division 26 ELECTRICAL TABLE OF CONTENTS

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SOUTHVIEW MEDICAL CENTER

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Page 1 of General


A. This Section includes the following lighting control devices:

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

GARCIA GALUSKA DESOUSA Consulting Engineers

CITY OF FARMINGTON 800 Municipal Drive Farmington, NM (505) Fax (505)

SECTION FIRE ALARM SYSTEMS

LIGHTING CONTROLS

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Product Specifications Dialog Room Controller* (*patent pending)

GE TLC Softwired Contactor TM Guideform Specification

CHAPTER 20 SERVICE EQUIPMENT

CONTENTS AUTOMATIC TRANSFER SWITCHES

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

2011 and 2014 National Electrical Code Changes Residential Only

SECTION ELECTRICAL REFERENCE SYMBOLS

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

The Owner will provide the QEI inspection and certification services.

1. Building wires and cables rated 600 V and less. 2. Connectors, splices, and terminations rated 600 V and less.

SECTION : FIRE ALARM & DETECTION SYSTEMS

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Town of Cicero Local Code Amendments

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

ELECTRICAL-GENERAL PROVISIONS SECTION A. The accompanying General Conditions shall apply to and form a part of this Section.

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems

SECTION COMMERCIAL-KITCHEN HOODS

UPTON TOWN HALL RENOVATIONS

PowerWave 2 Busway System

DIVISION SECTION ELECTRICAL. A. Provisions of General Requirements, Division 1, are a part of this section.

FIRE SUPPRESSION SPRINKLER SYSTEM

ORDINANCE NO

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

IEC and NCCER Mapping for Year 1

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

SECTION DOMESTIC WATER HEATERS

ALL ENGINEER NOTES SHALL BE DELETED FROM THE FILE OR MARKED AS HIDDEN. DIVISION 16 ELECTRICAL SECTION 16010

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Appendix B. Facilities Assessment Report

SECTION ENCLOSED CONTROLLERS

Gas Station & C Store SECTION CWM Job No

TABLE OF CONTENTS. Division 16 Electrical

DESIGN & CONSTRUCTION GUIDELINES

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

GE LightSweep Lighting Control System Guideform Specification

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

The following information shall become and form part of the contract documents.

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Transcription:

1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001

Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL Number Description Supplies 111 Supplies 110 109 108 Director Training 106 107 102 103 104 105 M101

Typ. Long Term Storage 205 Secure Storage 204 Consultant: Elevator Lobby 201 IT Work Room 202 IT Office 203 SECOND FLOOR PLAN MECHANICAL Number Description M102

ROOF PLAN - MECHANICAL Number Description M103

SCHEDULES MECHANICAL Number Description M201

DETAILS- MECHANICAL Number Description M301

Consultant: COMMISSIONING MECHANICAL Number Description M401

PLUMBING NOTES, DETAILS & SCHEDULES Number Description P001

Vestibule 117 LAN/IT Coffee 115 116 114 Mail Room 118 113 112 Scanning 119 Open Office 101 FLOOR PLAN - PLUMBING Number Description Supplies 111 Supplies 110 109 108 102 103 104 105 Training 106 Director 107 P101

Typ. Secure Storage 204 Consultant: Elevator Lobby 201 Long Term Storage 205 IT Work Room 202 IT Office 203 SECOND FLOOR PLAN PLUMBING Number Description P102

ELECTRICAL NOTES AND SPECIFICATIONS ELECTRICAL SYMBOL LIST ABBREVIATIONS 1. ALL WORK SHALL COMPLY WITH ALL THE APPLICABLE LOCAL, MUNICIPAL AND FIRE CODES. THE WORK SHALL BE IN TOTAL COMPLIANCE WITH THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. 2. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTION FEES AS REQUIRED FOR HIS PORTION OF THE WORK. 3. CONTRACTOR SHALL SUBMIT UTILITY COMPANY SERVICE APPLICATIONS. 4. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL COMPLETION. 5. CONTRACTOR SHALL COORDINATE ALL WORK WITH THE RESPECTIVE TRADES AND VERIFY LOCATIONS FROM THE ARCHITECTURAL DRAWINGS, FIELD MEASUREMENTS AND SUPPLIER SHOP DRAWINGS. 6. WORK REQUIRED OF ANY TRADE MAY BE SHOWN ANYWHERE ON ANY DRAWING OR IN ANY PART OF THE SPECIFICATIONS. 7. CONTRACTOR SHALL COMPLY WITH ALL IDENTIFICATION REQUIREMENTS OF THE NEC. 8. CONTRACTOR SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND SHALL INCLUDE ANY ELECTRICAL WORK INDICATED OR REQUIRED BY ANY TRADE. 9. CONTRACTOR SHALL REVIEW ALL OF THE CONTRACT DOCUMENTS TO DETERMINE THE FULL EXTENT OF THE WORK. ALL DIMENSIONS TO BE VERIFIED IN THE FIELD. 10. REVIEW ADOPTED CODES AND CODE AMENDMENTS WITH THE LOCAL GOVERNING AUTHORITIES AND BECOME FAMILIAR WITH THE LOCAL REGULATIONS RELATING TO THE WORK. 11. SHOP DRAWINGS a. SUBMIT COORDINATED SHOP DRAWINGS FOR ALL EQUIPMENT, LIGHT FIXTURES, PANELS, ETC. b. SUBMIT ALL SHOP DRAWINGS FOR REVIEW AND APPROVAL TO ARCHITECT'S OFFICE PRIOR TO PURCHASE, FABRICATION, AND INSTALLATION. c. CONTRACTOR SHALL HIGHLIGHT OR SUMMARIZE ANY DEVIATIONS IN THE SHOP DRAWING SUBMITTALS FROM THE CONTRACT DOCUMENTS. 12. LAYOUT OF EQUIPMENT, ACCESSORIES AND WIRING ARE DIAGRAMMATIC AND DO NOT INDICATE EVERY BOX, CONDUIT, WIRING OR SIMILAR ITEMS FOR A COMPLETE INSTALLATION. 13. CUTTING OF ANY STRUCTURAL MEMBER SHALL BE APPROVED BY THE ARCHITECT IN WRITING PRIOR TO WORK BEING DONE. 14. REMOVE PORTIONS OF EXISTING CEILINGS IN AREAS WHERE ELECTRICAL WORK IS INDICATED AND EXISTING CEILINGS ARE TO REMAIN. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS. REPLACE EXISTING CEILING TILES DAMAGED DURING WORK. PATCH AND PAINT EXISTING DRYWALL CEILINGS. 15. THE CONTRACTOR SHALL VERIFY THE NUMBER OF EXISTING SPARES AND SPACES. CONTRACTOR SHALL PROVIDE AND INSTALL OVER CURRENT DEVICES AS REQUIRED FOR NEW CIRCUITRY. 16. THE CONTRACTOR SHALL MAINTAIN THE ELECTRICAL CONTINUITY OF ELECTRICAL CIRCUITS, EQUIPMENT, AND DEVICES TO REMAIN. REWORK AND RE-CIRCUIT AS NECESSARY TO INSURE THE PROPER FUNCTIONING OF REMAINING CIRCUITS, EQUIPMENT, AND DEVICES. 17. CONTRACTOR SHALL FIELD VERIFY AND CONFIRM THE EXISTING SPARE PANEL CAPACITY TO ACCOMMODATE THE EXISTING AND NEW LOADS. MEASURE AVERAGE POWER DEMAND ON PANEL OVER A 15-MINUMTE PERIOD CONTINUOUSLY RECORDED OVER 30 DAY MINIMUM AND ADD NEW ADDITIONAL LOAD TO MAXIMUM RECORDED LOAD PER NEC. NOTIFY ENGINEER IF 125% X EXISTING MAXIMUM DEMAND + NEW LOAD EXCEEDS PANEL OR WIRE/CABLE RATING. 18. ALL ELECTRICAL OUTLETS, DEVICES, FIXTURES, ETC. NOT BEING RE-USED SHALL BE REMOVED. OUTLETS SHALL RECEIVE BLANK COVER PLATES. ALL WIRING SHALL BE REMOVED COMPLETELY. ALL ABANDONED CONDUIT, OUTLET BOXES, AND DEBRIS SHALL BE COMPLETELY REMOVED. EXISTING FIXTURES AND EQUIPMENT NOT BEING RE-USED SHALL BE RETURNED TO OWNER OR REMOVED FROM SITE AT OWNER'S DISCRETION. 19. EXISTING CONDUIT MAY BE REUSED PROVIDED IT MAINTAINS CONTINUITY OF GROUND, IT IS FREE OF DEBRIS, AND DOES NOT INTERFERE WITH NEW. 20. EXISTING ELECTRICAL CIRCUITS WHICH ARE TO REMAIN AND HAVE BEEN DISCONNECTED DURING DEMOLITION SHALL BE RECONNECTED TO NEW OR EXISTING SOURCE. 21. CIRCUIT NUMBERS GIVEN ON DRAWINGS ARE FOR CIRCUIT IDENTIFICATION ONLY. THE CONTRACTOR SHALL INSTALL CIRCUITRY AS GOVERNED BY FIELD CONDITIONS. HE SHALL KEEP A TYPED RECORD CORRELATING TO THE GIVEN AND ACTUAL CIRCUIT NUMBERS AND PROVIDE THIS INFORMATION ALONG WITH THE TYPED WRITTEN PANEL DIRECTORIES. 22. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF THE OTHER CONTRACTORS AND WITH THE EXISTING JOB SITE CONDITIONS. HE SHALL RELOCATE EQUIPMENT AS REQUIRED TO AVOID CONFLICT WITH OTHER TRADES. ALL DEVIATIONS SHALL BE APPROVED IN WRITING BY THE ARCHITECT PRIOR TO THE EXECUTION OF THE WORK. 23. RACEWAYS SHALL BE A MINIMUM 3/4" EMT FOR LIGHTING AND APPLIANCE BRANCH CIRCUITRY AND MINIMUM 1" EMT FOR TELEPHONE & DATA. ONE-HALF INCH EMT ALLOWED FOR SINGLE OUTLET AND SWITCH LOCATIONS. 24. ALL LINE VOLTAGE CONDUCTORS SHALL BE COPPER, MINIMUM #12 GAGE, 98% CONDUCTIVITY WITH 600 VOLT INSULATION, SUITABLE FOR 60 C OPERATING TEMPERATURE, APPROPRIATE FOR DRY OR WET LOCATIONS, THW, THWN OR THHN FOR BRANCH CIRCUITS, SIZES #10 AND LARGER TO BE STRANDED. FEEDERS AND MOTOR POWER CIRCUITS SHALL BE THW OR THHN, COPPER WITH 600 VOLT INSULATION, SUITABLE FOR 75 C OPERATING TEMPERATURE AND APPROPRIATE FOR DRY OR WET LOCATIONS. LOW VOLTAGE CONDUCTORS SHALL BE MINIMUM #14 GAGE. 36. ALL ELECTRICAL EQUIPMENT AND INSTALLATION ABOVE THE CEILING SHALL BE APPROVED FOR PLENUM CONDITIONS. PROVIDE CONDUIT THROUGH PLENUMS FROM ALL DATA AND PHONE RECEPTACLES TO SERVER ROOM(S) AND TELEPHONE EQUIPMENT LOCATIONS. 37. ALL CIRCUITRY TO BE RUN CONCEALED UNLESS OTHERWISE INDICATED. 38. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHER RECOGNIZED TESTING LAB. 39. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. 40. WIRING DEVICES: a. RECEPTACLES SHALL BE PROVIDED WHERE SHOWN AND BE NEMA 5-20R, COMMERCIAL GRADE AS MANUFACTURED BY LEVITON, HUBBELL OR APPROVED EQUAL. b. SWITCHES SHALL BE PROVIDED WHERE SHOWN AND BE COMMERCIAL GRADE, MANUFACTURED BY LEVITON, HUBBELL OR APPROVED EQUAL. c. COVER PLATES SHALL MATCH EXISTING OR AS DIRECTED BY ARCHITECT d. RECEPTACLES LOCATED WITHIN TOILETS AND MOUNTED ON THE EXTERIOR SHALL BE GFCI COMMERCIAL GRADE. e. ALL WALL SWITCHES IN ROOMS WITH CEILING MOUNTED OCCUPANCY OR VACANCY SENSORS SHALL BE LOW VOLTAGE MOMENTARY TOGGLE SWITCH TYPE. 41. RECEPTACLES ON OPPOSITE SIDES OF A FIRE RATED WALL ASSEMBLY SHALL BE HORIZONTALLY SEPARATED BY NOT LESS THAN 24 INCHES OR SHALL BE PROTECTED WITH INTUMESCENT PUTTY PADS. 42. COORDINATE WITH OTHER TRADES FOR EXACT LOCATIONS OF MOTORS AND OTHER EQUIPMENT REQUIRING POWER. a. FINAL CONNECTIONS TO EQUIPMENT SHALL BE MADE WITH "LIQUID TIGHT" FLEXIBLE STEEL CONDUIT, ¾" MINIMUM. b. PROVIDE LOCAL DISCONNECT FOR ALL MOTORS. VERIFY MANUFACTURE'S RECOMMENDED DISCONNECT SIZE PRIOR TO ORDERING AND INSTALLATION. c. PROVIDE STARTERS FOR ALL MECHANICAL EQUIPMENT WHICH REQUIRES INTERLOCKING. COORDINATE SIZE AND LOCATION OF STARTERS WITH MECHANICAL CONTRACTOR. d. FOR ALL AC MOTORS NOT PROVIDED WITH BUILT-IN THERMAL OVERLOAD PROTECTION, PROVIDE MANUAL MOTOR STARTERS WITH OVERLOAD HEATER ELEMENTS SIZED TO THE NAMEPLATE CURRENT RATING OF THE MOTOR. SMALL AC MOTORS WITH BUILT-IN THERMAL OVERLOAD PROTECTION, PROVIDE HORSE POWER RATED TOGGLE TYPE DISCONNECT SWITCH. 43. ELECTRICAL PANELS SHALL HAVE BOLT-ON TYPE CIRCUIT BREAKERS WITH SHORT CIRCUIT INTERRUPTING RATINGS TO EXCEED THE AVAILABLE SHORT CIRCUIT CURRENT. 44. ALL 120 VOLT CIRCUITS SHALL HAVE A DEDICATED NEUTRAL, SHARING A NEUTRAL CONDUCTOR IS PROHIBITED UNLESS INSTALLED IN ACCORDANCE WITH ARTICLE 240.15 (B)(1) AND ALL RELATED ARTICLES. 45. FIRE ALARM SYSTEM: FIRE ALARM SYSTEM SHALL BE DESIGN/BUILD. ALTER AND ADD TO EXISTING SYSTEM AS NECESSARY TO PROVIDE A COMPLETE ADDRESSABLE FIRE ALARM SYSTEM INSTALLED IN ACCORDANCE WITH ALL GOVERNING AUTHORITIES WHICH HAVE JURISDICTION OVER THIS PROJECT. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO ALL EQUIPMENT, DETECTION DEVICES, HEAT DETECTORS, SMOKE DETECTORS, DUCT SMOKE DETECTORS, REMOTE DUCT DETECTOR TEST SWITCHES, AUDIBLE/VISUAL DEVICES, PULL STATIONS, PROPER ADDRESSING OF EQUIPMENT, CONDUIT, BOXES, WIRE, ETC. AS REQUIRED FOR A COMPLETE SYSTEM. 46. THE CONTRACTOR SHALL PROTECT THE EXISTING FACILITY AND SHALL EXERCISE CARE NOT TO DAMAGE ANY EXISTING TO REMAIN. ALL WORK DAMAGED BY THE CONTRACTOR MUST BE RESTORED SO AS TO MATCH EXISTING AND AS APPROVED BY THE ARCHITECT. ANY SUCH CORRECTIVE WORK MUST BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. 47. LIGHTING SYSTEM FUNCTIONAL TESTING: a. FUNCTIONAL TESTING SHALL BE PERFORMED IN COMPLIANCE WITH C408.3 OF THE IECC 2015 BY THE GENERAL CONTRACTOR TO ENSURE THAT THE HARDWARE IS CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE DOCUMENTS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. b. TESTING SHALL CONFIRM THAT THE PLACEMENT, SENSITIVITY AND TIME-OUT ADJUSTMENTS FOR OCCUPANT SENSORS YIELD ACCEPTABLE PERFORMANCE. c. CONFIRM THAT THE TIME SWITCHES AND PROGRAMMABLE SCHEDULE CONTROLS ARE PROGRAMMED TO TURN THE LIGHTS OFF. d. CONFIRM THAT THE PLACEMENT AND SENSITIVITY ADJUSTMENTS FOR PHOTOSENSOR CONTROLS REDUCE ELECTRIC LIGHT BASED ON THE AMOUNT OF USABLE DAYLIGHT IN THE SPACE AS SPECIFIED. 48. MANUALS: DOCUMENTS DESCRIBED BELOW SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE (U.N.O.) OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY: a. SUBMITTAL DATA STATING EQUIPMENT SIZE AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE b. MANUFACTURER'S OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, EXCEPT EQUIPMENT NOT FURNISHED AS PART OF THE PROJECT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. c. NAME AND ADDRESS OF AT LEAST ONE SERVICE AGENCY d. A NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE, INCLUDING RECOMMENDED SET-POINTS e. AS-BUILT DRAWING(S) OF ELECTRICAL POWER SYSTEMS WITHIN 30 DAYS OF SYSTEM ACCEPTANCE Consultant: ELECTRICAL NOTES, DETAILS & SCHEDULES Number Description 25. RACEWAY FITTINGS SHALL BE GALVANIZED STEEL. EXTERIOR MOUNTED RACEWAYS SHALL BE GALVANIZED RIGID STEEL (GRS) OR INTERMEDIATE RIGID STEEL (IMC) WITH THREADED FITTINGS, PROTECTED WITH GALVANIZED COATING. EXTERIOR MOUNTED DEVICES SHALL BE INSTALLED IN WEATHERPROOF ENCLOSURES. 26. INSTALL FITTINGS TO ACCOMMODATE EXPANSION AND DEFLECTION WHERE RACEWAY CROSSES CONTROL AND EXPANSION JOINTS 27. PROVIDE PULL WIRE IN ALL EMPTY CONDUITS. 28. ALL BRANCH CIRCUITS SHALL BE GROUPED INTO PHASE BALANCED MULTIPLE CIRCUIT HOMERUNS. A MAXIMUM OF 4 CIRCUITS PER SINGLE HOMERUN. 29. THE CONTRACTOR SHALL PROVIDE A COMPLETE CONDUCTOR AND RACEWAY SYSTEM FOR ALL CIRCUIT DEVICES INDICATED ON THE PLANS EVEN THOUGH NOT DELINEATED. 30. WIRES FOR 120 VOLT BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH FROM PANEL TO CENTER OF LOAD SHALL NOT BE SMALLER THAN #10 AWG. 31. INSTALLATION OF ALL LIGHTING FIXTURES SHALL INCLUDE ALL NECESSARY CONDUIT (SOLID OR FLEXIBLE), WIRING, JUNCTION BOXES, ETC., FOR CIRCUIT DEVICES. 32. VERIFY ALL CEILING SYSTEM TYPES WITH ARCHITECTURAL PLANS PRIOR TO ORDERING LIGHTING FIXTURES AND PROVIDE REQUIRED HARDWARE AND FRAMES REQUIRED FOR CEILING TYPE. 33. PROVIDE FIRE RATED ENCLOSURES FOR ALL RECESSED LIGHT FIXTURES, SPEAKERS, RECEPTACLES, ETC. INSTALLED IN FIRE RATED CEILINGS OR WALLS. ENCLOSURE FIRE RATINGS SHALL EQUAL THE CEILING OR WALL RATING. COORDINATE WITH ARCHITECTURAL PLANS FOR FIRE RATED CEILING AND WALL LOCATIONS. 34. EACH BALLASTED FLUORESCENT FIXTURE TO BE FURNISHED WITH A BUILT-IN U.L. RATED INTERNAL LINEAR DISCONNECTING DEVICE THAT WILL SIMULTANEOUSLY DISCONNECT ALL CONDUCTORS, INCLUDING THE GROUND CONDUCTOR THAT ARE FEEDING THE BALLAST. 35. SUPPORT ALL LAY-IN LIGHT FIXTURES WITH TWO NO. 12 GAUGE WIRES SECURED FROM LIGHT FIXTURE AT OPPOSING CORNERS ALONG THE FIXTURE'S DIAGONAL. E100

Vestibule 117 Coffee 116 LAN/IT 115 114 Mail Room 118 113 112 LP-3 LRP Scanning 119 Open Office 101 FIRST FLOOR PLAN - LIGHTING Number Description 111 110 RELAY PANEL "LRP" SYSTEM DIAGRAM SCALE: NONE RELAY PANEL LRP SCHEDULE RELAY NO. RELAY TYPE CONTROL TYPE A OVERRIDE BUTTON WEEKDAY ON SCHEDULE WEEKDAY OFF WEEKEND ON WEEKEND OFF PANELBOARD LP-3, UNO CKT NO. CONTROL AREA 109 108 102 103 104 105 Training 106 Director 107 E101

Secure Storage 204 Long Term Storage 205 Elevator Lobby 201 IT Work Room 202 IT Office 203 SECOND FLOOR PLAN - LIGHTING Number Description E102

Storage Shelving Storage Shelving Storage Shelving Consultant: Printer 96" Vestibule 117 TV CLG MTD Printer 48" GFI 44" GFI 44" Printer 48" LAN/IT 115 Coffee 116 CR 114 48" 44" 44" 44" 44" Printer 113 44" 44" 44" Mail Room 118 112 Scanning 119 Printer Copier FIRST FLOOR PLAN - POWER Printer Number Description Open Office 101 111 Printer 110 Corridor 163 Electrical 120 Printer Copier Reception Printer Remote 109 108 48" 96" 102 103 104 105 Training 106 Director 107 E103

UP DN Secure Storage 204 Consultant: Long Term Storage 205 48" CR Elevator Lobby 201 IT Work Room 202 CR Director 107 IT Office 203 SECOND FLOOR PLAN - POWER Number Description REVISION 09/06/16 E104

ELECTRICAL ROOF PLAN Number Description E105

Consultant: ELECTRICAL SCHEDULES Number Description E201

FIRST FLOOR PLAN - DEMOLITION Number Description ED101

SECOND FLOOR PLAN - DEMOLITION Number Description ED102