NOTE TO SPECIFYING ARCHITECT REGARDING SECTION PERFORMANCE LIGHTING SYSTEM (24 DIMMERS)

Similar documents
PROJ. NO SECTION THEATRICAL LIGHTING

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

GARCIA GALUSKA DESOUSA Consulting Engineers

STATEMENT OF WORK. System Description:

SECTION LOW VOLTAGE LIGHTING CONTROLS

MaxLite LED Round Pendant Highbay Series

East Central College

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

AMERICAN AIR & WATER, INC.

GE LightSweep Lighting Control System Guideform Specification

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

CRESTRON MEDIAMANAGER INTELLICLASS

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

SECTION (16140) - WIRING DEVICES

SECTION PUBLIC ADDRESS SYSTEMS

Lighting Control Panels

USER MANUAL Table of Contents

PowerWave 2 Busway System

Altman Lighting Spectra Cyc UV 50 Specification

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

IN2 Lighting Control Devices

SECTION NURSE CALL SYSTEM

Product Specifications Dialog Room Controller* (*patent pending)

DRC12FR DRC12FR347. Dynalite. Install Guide

USER MANUAL Table of Contents

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

SECTION AUTOMATIC TRANSFER SWITCHES

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

MaxLite LED Vapor Tight Linear Fixture

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

CCS-100. Installation Manual

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Tilt 'N Plug Jr. Interconnect Box

Elements Headwall System (P2008A)

Video Surveillance Remote Devices and Sensors

SERVICE BY QUALIFIED PERSONNEL ONLY

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

SECTION FIRE ALARM SYSTEMS

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

SECTION INTRUSION DETECTION SYSTEM

SECTION LIGHTING CONTROLS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

PRO-WATCH NOTIFIER SECONDARY FIRE INTERFACE ARCHITECT AND ENGINEERING SPECIFICATION

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section.

V-PIX Vision Bar LED Pixel Bar Light. User Manual KEEP THIS MANUAL FOR FURTURE NEEDS

The following information shall become and form part of the contract documents.

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

FLCH4R Garage and Utility Electric Heater

A. Product Data: Include rated capacities, furnished specialties and accessories.

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Unison Echo Contact Interfaces

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Stellar Panelboard Dimming Systems

LED Flood EX 21. User Manual

SECTION HEALTHCARE COMMUNICATION AND MONITORING SYSTEM (NURSE CALL)

USER MANUAL Table of Contents

USER GUIDE & INSTALLATION INSTRUCTIONS

ONYX FirstVision Specification Interactive Firefighters Display

ARCSYSTEM. Fully-dimmable LED lighting for auditoriums, retail and commercial installations

Read these instructions carefully and completely. NOTE This appliance must be properly grounded.

The Johns Hopkins Health Systems July 12, 2013 Facilities Standard Specification SECTION LIGHTING CONTROL SYSTEM PART 1 - GENERAL

SECTION EXTERIOR LIGHTING

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

A. This Section includes the following lighting control devices:

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

SECTION ELECTRICAL GENERAL PROVISIONS

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

IMPORTANT INSTRUCTIONS READ & SAVE

SECTION DOMESTIC WATER PUMPS

ThermoCable Linear Heat Detection System

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

DONALD H. BERG, ARCHITECT

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

CFX2-RGB SPECIFICATIONS LUMEN DATA DESCRIPTION FEATURES. Type. Project LED FLEXIBLE LINEAR CFX2 RGB FLEXIBLE LED STRIP. Catalog No.

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Intensity Level. Intensity Control. Signal Type Switch. 12V Power Port. Signal Ports

C. Pigtail: Short lead used to connect a device to a branch-circuit conductor.

SECTION LIGHTING

Unison Echo Inspire Control Stations

D. Reference Standards (Utilize latest editions available):

WPLED 26W INSTALLATION INSTRUCTIONS

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

SECTION INTRUSION DETECTION

Transcription:

NOTE TO SPECIFYING ARCHITECT REGARDING SECTION 11087-24 PERFORMANCE LIGHTING SYSTEM (24 DIMMERS) Small complete performance lighting system (dimmers, control, distribution, and lighting fixtures). The smallest system recommended for educational theatres. Modest budget. Phone 800-548-8982 for clarification or assistance. No charge, of course.

SECTION 11087-24 PERFORMANCE LIGHTING SYSTEM (24 DIMMERS) PART 1-GENERAL 1.01 Furnish and deliver a stage lighting control system described hereinafter. Equipment shall conform to all applicable provisions of local electrical code, National Electric Code, and NBFU current issue. The lighting control system specified as the standard is Janson-ETC digital lighting system. (Janson Industries 800 548 8982) 1.02 Provide and install dimmers and controls as specified herein and as shown on the drawings. Contractor is to receive, mount, connect, and place all equipment in operation. Contractor will furnish all conduit, wire, connectors, and hardware, and other incidental items necessary for a complete and properly functioning lighting and dimming system. 1.03 Shop drawings shall be submitted for approval within 30 days after receipt of contract. No fabrication of equipment is to proceed prior to approval of these drawings. Submittal package shall contain six (6) sets of the following. A. Complete material list. B. Sets of catalog cut sheets of standard equipment. C. Sets of shop drawings detailing all mechanical and electrical equipment including riser diagrams, wire counts, internal wiring and physical dimensions of each item. 1.04 Prime electrical contractor shall furnish and install new dimmer panel and connect the power and the load circuits to the new dimmer panel. Prime electrical contractor shall furnish and install and connect all circuits that terminate in gridiron junction boxes, wall boxes, outlet boxes, etc, as well as all dimmable circuits that home-run to dimmer rack SR. 1.05 Base bid includes 24 dimmers (12 modules), which include all dimmable performance light circuits plus all dimmable house light circuits. PART 2-MATERIALS 2.01 LIGHTING CONTROL SYSTEM TO CONSIST OF: A. Unison Dimmer Rack-Model DR12-24-100-wall mounted cabinet to contain: 1-DR12 Dimmer enclosure for 12 modules-designed for 3 phase 4 wire and ground operation at a maximum of 160 A, 120/208V, 60Hz AC 12-D20 Dual dimmer modules (24 dimmers) AFM Air Flow modules (as needed) 1-locking door with filter B. Express 24/48 Control Console-96 channels x 1,024 DMX512 dimmers, to contain: 96 Channels 1024 DMX512 dimmers 600-Cues 500-Groups 99 focus points Effects eith up to 100 steps each 2,000-Macros 24-Submaster x 10 pages 2 timed/manual fader pairs 1-Diskette drive 1-Single VGA output 1-Printer port UL, cul, CE listed 11087-24-1

C. Accessories 1-CD-25DMX Digital control cable 2-ECPB-DMX Console plug-in stations 1-Color VGA Monitor 1-Control console dust cover 1-Monitor dust cover D. Module U 10001 Panic Station with lockable cover (2 required) Houselight control on-off (6 required) E. Model U407121F-(2 required)-unison Control Station with each as follows: 1-White faceplate assembly to include the following: (in booth and on stage) 1- Master Slider Assembly 6- Zone X Slider Assembly 9- Preset X Select Switch 1- Off Select Switch 1- Manual Select Switch 1- Record Select Switch F. Model U2RSP-11F-(2 required)- PC Interface Station for plugging-in control console with: 1-White faceplate assembly to include the following: 1- Computer Unison PC Connector (symbol PIS on drawings) G. Provide Model ASTS for emergency power to 8 designated circuits 2.02 DISTIBUTION EQUIPMENT A. Connector Strips 1 CS-40-5BPR31 Connector strip 40'-0" Long with 10-18" pigtails and 20A PIN connectors wired on 5-20A circuits plus 9 hanging brackets complete with Gridiron junction box 1-45 ft run of #12/15 conductor SO multiconductor cable, cradles and standard Kellems strain relief (circuit aabb...) 1 CS-40-4BPR31 Connector strip 40'-0" Long with 8-18" pigtails and 20A PIN connectors wired on 4-20A circuits plus 9 hanging brackets complete with Gridiron junction box, 1-45' run of #12/12 conductor SO multiconductor cable, cable cradles and standard Kellems strain relief (circuit aabb...) 1 CS40-3BPR31 Connector strip 40'-0" Long with 6-18" pigtails and 20A PIN connectors wired on 3-20A circuits plus 9 hanging brackets complete with Gridiron junction box, 1-45' run of #12/9 conductor SO multiconductor cable, cable cradles, and standard Kellems strain relief. (Circuit aabb...) NOTE: All pipe and rigging is specified in a different section of the specifications. B. Pigtail and Outlet Boxes Surface mounted junction boxes at stage roof steel (3) D-JBO5-30 (1) 5 circuit gridiron junction box (1) 4 circuit gridiron junction box (1) 3 circuit gridiron junction box (8) Pipe mounted outlet boxes each with 2-20A pin connector receptacles complete with U-bolts for mounting. (Each box has 2 outlets; 1 circuit) These front-of-house boxes shall be wired using conduit. Connector strip is not required. 11087-24-2

2.03 THEATRE FIXTURES AND ACCESSORIES A. Focusing Units 3 ETC 419j-b Source Four JR ellipsoidal with HPL 575 lamp, and 20A stage pin connector wired on, c-clamp, colorframe and safety cable. 5 ETC S4PAR-EA-B Source Four PAR spotlights complete with c-clamp, colorframe, safety cable, 4 lens set, 1M lead with 20A stage pin connector wired on, and HPL 575 lamp 4 ETC 426J-B Source Four JR ellipsoidal spotlights complete with c-clamp, colorframe, safety cable, 1 M lead with 20A stage pin connector wired on, and HPL 575 lamp 3 ETC 450J-B Source Four JR ellipsoidal spotlights complete with c-clamp, colorframe, safety cable, 1M lead with 20A stage pin connector wired on and HPL 575 lamp 6 Altman 165Q 6 fresnels complete with c-clamp, colorframe, safety cable, 1M lead with 20A stage pin connector wired on and 500W BTL lamp B. Follow Spotlight 1-Altman Follow Spotlight, Comet with lamp, and 25 ft of feed cable, iris, color boomerang, tripod, and dolly 2.04 MANUFACTURER S SERVICES A. Seven sets of B size drawings for approval submitted within 2-6 weeks of receipt of order. B. Two-year limited warranty on parts and workmanship. C. Services of a factory engineer to energize system and instruct user personnel. Such services shall be supplied on 21 days notice. D. Production requires 1-6 weeks for delivery of equipment after receipt of written approval and release. E. Two sets of Operation Manuals. PART 3-EXECUTION 3.01 Furnish all of the above equipment complete with all lamps, color frames, plastic color mediums, cords, plugs, cradles, pipe clamps and all other equipment necessary for a complete installation. All equipment shall be furnished and installed completely, and shall be left ready for use. All equipment furnished and installed shall be consistent with requirements of the National Electric Code. END OF SECTION 11087-24-3