PRODUCT CONFORMITY CERTIFICATE

Similar documents
PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Low Temperature Zirconia Oxygen Analyzer

Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

multiranger 100 / 200

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Instruction Manual August sitrans CU 02

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Instruction Manual December 2001 ENACOCU02

CU-02 with Senaco Plus

Continuous level measurement Ultrasonic transmitters

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3490 Series

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Model 144H. Product Data Sheet , Rev DB February Content

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ALTAIR 5X Multigas Detector Product Specification

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

FUNCTIONAL SAFETY CERTIFICATE

IRceL CH4 Methane (CH 4

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Level Measurement Continuous level measurement - Ultrasonic transmitters

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Level Measurement Continuous level measurement Ultrasonic transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters

General Routing Interface

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Non-Contacting Point Level Detection and Pump Control Sensor. Setting a New World Standard

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Two-Channel Gas Controller

IR15 Dual Gas Series Datasheet

10yr O2NE & Safe-Ox. User Manual

Room thermostat with 24-hour time switch and large LCD

IR25 Dual Gas Series Datasheet

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

PTE0705 Electric Fence Monitor

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

SITRANS T temperature transmitters A broad product family for every application. sitrans

srra, of Conformity IECEx Gert f cate ?-ot,b

Instruction Manual April sitrans AS 100

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Certificate: / 29 April 2014

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

I/A Series 716C 1/16 DIN Temperature Controller

Series Temperature Controller Instruction Sheet

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Combustible Gas Detection and Control System

Quick Start Manual July pointek CLS100

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

OPTIMUM APPLIED SYSTEMS,

02/11/2015

02/11/2015

Oxygen (O2) Single-Point Gas Detection System

LC1350 Level Controller

Semi flush-mount room thermostats

Mobrey MCU900 Series Universal Control Unit

3500/61E & 3500/67E Temperature Monitor

ClampOn DSP Corrosion- Erosion Monitor

Self-learning Room Temperature Controller

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

CMT MANUAL 6. NMC SENSORS

Test Report Garvan Enterprises Limited

Certificate: _02 / 22 March 2013

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

SECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN

EC PARTS CERTIFICATE GB-1432

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

SECTION Free/Available Chlorine Analysis System

Rosemount 3100 Series Ultrasonic Level Transmitters

BA374C Intrinsically safe field mounting indicating temperature transmitter

Transcription:

PRODUCT CONFORMITY CERTIFICATE HydroRanger 200 Controller (segmented display or HMI display) with Echomax XRS-5 ultrasonic level transducer manufactured by: Siemens Canada Ltd. Siemens Milltronics Process Instruments 1954 Technology Drive, P.O. Box 4225 Peterborough Ontario K9J 7B1 Canada has been assessed by Sira Certification Service and for the conditions stated on this certificate complies with: MCERTS Performance Standards and Test Procedures for Continuous Water Monitoring Equipment Part 3, Version 2.4 dated February 2013 Certification Range 0 to 2 metres (nominal) Project No.: 16W0430 Certificate No: Sira MC 050057/06 Initial Certification: 29 June 2005 This Certificate issued: 23 September 2015 Joe Prince MSc, MInst MC Renewal Date: 28 June 2020 Deputy Certification Manager MCERTS is operated on behalf of the Environment Agency by Sira Certification Service Unit 6, Hawarden Industrial Park Hawarden, Deeside, CH5 3US Tel: +44 (0)1244 670 900 The MCERTS certificate consists of this document in its entirety. For conditions of use, please consider all the information within. Page 1 of 6

Certificate Contents Approved Site Application... 2 Basis of certification... 2 Product certified... 3 Certified Performance... 4 Description... 6 General notes... 6 Approved Site Application Any potential user should ensure, in consultation with the manufacturer, that the monitoring system is suitable for the intended application. For general guidance on monitoring techniques refer to the Environment Agency Monitoring Technical Guidance Notes available at www.mcerts.net The product is suitable for use, where it is appropriate, for regulated applications such as abstraction, effluent discharge, ultraviolet disinfection and industrial processing. The manufacturer states that the HydroRanger 200 is suitable for indoor and outdoor use up to a maximum altitude of 2000m. The enclosure is IP65 rated (wall mount version) and IP54 rated (panel mount version). The optional TS-3 temperature sensor is suitable for use in ambient conditions of -40 C to 100 C (- 40 F to 212 F) while the intrinsically safe hand-held programmer is suitable for use in potentially explosive atmospheres as per certificate No. SIRA 01ATEX2147. The Echomax XRS-5 Transducer is suitable for indoor and outdoor use up to a maximum altitude of 2000m. The XRS-5 enclosure is IP68 rated. A three month field test was performed to meet the MCERTS requirements. Basis of certification This certification is based on the following Test Report(s) and on Sira s assessment and ongoing surveillance of the product and the manufacturing process: Sira Report Reference No: C 1223 dated July 2005 Sira Report Reference No: C 1266 dated June 2010 WRc Report Reference No: UC 8313 dated May 2010 WRc Report Reference No: UC10720 v.10 dated March 2015 Page 2 of 6

Product certified The HydroRanger 200 measuring system consists of the following parts: HydroRanger 200 controller (segmented display or HMI display) XRS-5 ultrasonic transducer This certificate applies to all instruments fitted with software version 1.07 onwards (serial number PBD/A7060001 onwards). Page 3 of 6

Certified Performance The instrument was evaluated for use under the following conditions: Ambient Temperature Range: -25 o C to +55 o C (Note 1) The instrument meets MCERTS Class 2 requirements for the combined performance characteristic as specified in Table 7 of the MCERTS performance standard. Details of individual performance characteristics are summarised below: Results are expressed as error % of certification range, unless otherwise stated. Test Results expressed as error % of certification range <0.1 <0.2 <0.5 <1.5 Other results MCERTS specification Protection against unauthorised access The unit is password protected Clause 3.1.2 Units of measurement Indicating device Flow computation Combined performance characteristic The indicating device and output are scaled in metric units The flowmeter incorporates an indicating device, analogue and digital output signal The flowmeter incorporates a facility for a user defined stage/discharge curve to be entered 0.47 Clause 3.1.6 Clause 3.1.3 Clause 3.1.11 Clause 4.3.1 ±0.5% Class 2 Mean error Repeatability Resolution 0.019-0.15 2mm Clause 6.3.2 ±0.3% Class 2 Clause 6.3.2 0.05% Class 1 Clause 3.1.15 <2mm Class 1 Supply voltage 99 to 121 V AC / 207 to 253 V AC -0.025 Output impedance 1 to 750Ω -0.006 Ambient air temperature -25 C to +55 C 0.22 Clause 6.3.3 Clause 6.3.4 Note 1 Clause 6.3.6 Accuracy of computation -0.014 Clause 6.3.11 User defined stage-discharge equation -0.041 result not included in combined performance characteristic Note 2 Clause 6.3.12 0.075% Class 2 Page 4 of 6

Test Warm up time Results expressed as error % of certification range <0.1 <0.2 <0.5 <1.5 Other results the unit stabilises after energising within 5 seconds MCERTS specification Clause 6.1.2 to be reported Loss of Power for electronic flowmeters no changes in pre-set data Clause 6.3.1 to be reported Relative humidity 0.2 result not included in combined performance characteristic Note 3 Clause 6.3.6 0.25% Class 3 Direct solar radiation 0.25 Clause 6.3.10 0.5% Class 3 Response time 25s Clause 6.3.19 <30 seconds Error under field test conditions error range -0.6% to +0.9% field test error is <0.2% for 56.1% of readings field test error is <0.5% for 93% of readings field test error is <1.5% for 100% of readings Clause 7.3 0.5% Class 2 Up time Maintenance 100% None Clause 7.4 >95% Clause 7.5 to be reported Note 1 : The manufacturer specifies an ambient temperature of -20 o C to +50 o C Note 2 : User defined curve 1 (f= 38537.5, n+ 1.55) & User defined curve 2 (f = 21481.8, n= 2.50) Note 3 : Note 4 : Test performed at 35 o C and 93% RH and not 40 o C and 93% RH as specified in the MCERTS standard The following tests are not applicable to the flowmeter: 6.3.5 Fluid temperature 6.3.15 Ancillary devices 6.3.7 Incident light 6.3.16 Effect of conduit material 6.3.8 Sensor location 6.3.17 Effect of conduit size 6.3.9 Presence of stray currents 6.3.18 Fill level 6.3.13 Bi-directional flow 6.3.20 Vibration 6.3.14 Flow reversal Page 5 of 6

Description The HydroRanger 200 is a non-contact level monitoring controller that features advance relay alarming, differential level measurement, open channel flow monitoring, and volume conversion. It is housed in a polycarbonate enclosure; the segmented display version comes with a hand held infra-red programmer while the HMI display version can be programmed using the pushbuttons provided on the lid. As a system, it is used in conjunction with a remote ultrasonic transducer and an optional TS-3 temperature sensor. The HydroRanger 200 transmits a pulse signal to the transducer that is then emitted as ultrasonic pulses. The pulses echo off the water surface and are then sensed by the transducer. The time for a pulse to echo back from the water surface is temperature compensated and converted into a measurement of head. It uses an algorithm to convert the head measurement into flow rate. The flow rate is totalised and stored in a data log to provide detailed flow analysis. The remote control device supplied with the segmented display version is a hand-held, infra-red programming unit that offers access to the configuration parameters of Siemens Milltronics products, including the HydroRanger 200. When in use, the programmer should be pointed at the instrument display window. The programmer is powered by a non-replaceable 3V lithium battery. Note: The XRS-5 transducer incorporates an integral temperature sensor that reports ambient temperature to the HydroRanger 200, allowing it to automatically compensate the speed of sound for varying temperatures. In situations where the transducer is exposed to direct sunlight, or where variation in temperature of the sound medium is expected, use of a TS-3 temperature sensor will increase overall accuracy. General notes 1. This certificate is based upon the product tested. The Manufacturer is responsible for ensuring that on-going production complies with the standard(s) and performance criteria defined in this Certificate. The Manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management system shall be subject to regular surveillance according to Regulations Applicable to the Holders of Sira Certificates. The design of the product certified is defined in the Sira Design Schedule V06 for certificate No.. 2. If certified product is found not to comply, Sira Certification Service should be notified immediately at the address shown on page 1. 3. The Certification Marks that can be applied to the product or used in publicity material are defined in Regulations Applicable to the Holders of Sira Certificates. 4. This document remains the property of Sira and shall be returned when requested by the company. Page 6 of 6