Industrial Strength Leak Detection

Similar documents
Industrial Strength Leak Detection

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

TraceTek Leak Detection

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

Fuel Leak Detection Find Leaks Before They Find You

fuel leak detection find leaks before they find you

TT7000-HUV TraceTek Sensing Cable for Strong Mineral Acids

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Sensor Interface Module Installation/Operation Instructions

TraceTek TT1000 Modular Sensing Cable

TTSIM-1 Sensor Interface Module

TraceTek FIND LEAKS BEFORE THEY FIND YOU

PRODUCT SELECTION GUIDE FOR WATER SENSING SYSTEMS

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

C910 Series. Single-point heat-tracing control system

aquilar - leak detection solutions

ACCS-30. Multipoint commercial heat-tracing control system

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

aquilar - leak detection solutions

TT5000-HS (for fuel leaks) TT5001-HS (for solvent leaks) TraceTek Sensing Cable for Underground Leak Detection

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

TraceTek TT1000 Modular Sensing Cable

water leak detection

RayClic Connection System

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

Installation, Operation and Maintenance Manual

TT3000 and TT5000 Series

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Water Leak Detection Find Leaks Before They Find You

RAYCHEM NGC-30 COMPONENTS

TraceTek Sensing Cable for Underground Leak Detection Installation Instructions. Description. Heat shrink tubing segments. Optional Materials

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Leak Detection and Location Systems

Gardian W51. Approvals

TT3000 and TT5000 Series

HTC-915-CONT. Heat-Trace Control system

TraceTek Sensing Cable for Aboveground Leak Detection Installation Instructions

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

C A Heating Cable Gland Kit

910 Series Single-point heat-tracing control system

Minimize Leaks Maximize Asset Protection

ASAHI/AMERICA Leak Detection Basics

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

TT3000 and TT5000 Series

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

When reliability is vital. Alemite Carbon Shield TM Systems deliver

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

Danfoss gas detection units

MODEL DESCRIPTION PAGE

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

MODEL 4000A & 4001A ACCELEROMETER

TraceTek Long-Line and Zone Leak Detection and Location Systems. Operation and Maintenance Manual

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

QuickStat-TC Installation & Operation Manual

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

For Complete Fire and Gas Solutions

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

On the job around the clock 24/7: Fire detection systems

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Danfoss gas detection units

Industrial Grade Gas Detection Detecting The Difference

Warranty Registration

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

AS950 REFRIGERATED SAMPLERS

Low Temperature Zirconia Oxygen Analyzer

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

LEAK DETECTION/LOCATION SYSTEMS PAL-AT LIQUIDWATCH FLUIDWATCH

RS485 MODBUS Module 8AI

Dual-point heat-tracing control system

Two-Channel Gas Controller

Raychem Heating System

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

Cable Actuated Sensor Industrial User Scalable 4 20mA

Product Data Sheet. Remote Terminals. Features:

Cable Actuated Sensor Industrial User Scalable VDC Output

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Supervisor Standard Edition

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

Carbon Monoxide Transmitter

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Danfoss gas detection unit Type GD Heavy Duty

Gas Controller Module GC-06

/8 DIN Level Indicator

NGC-40 Advanced Heat-Tracing Control System

Flexible Air-sampling Smoke Detection

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

Design Guide for Double Containment Pipes and Tanks. TraceTek Leak Detection and Location Systems

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Transcription:

Industrial Strength Leak Detection Don t let an undetected leak or spill ruin the environment or your reputation...

TraceTek Technology: Find leaks before major damage is done... TraceTek Technology: Sensor cable suited to the task TT3000 for acids, bases and other hazardous fluids with water content TT5000 for gasoline, jet fuel, diesel, crude oil, lube oil and other hydrocarbon based liquids TT5001 for organic solvents TT7000 for strong acids and bases Detect a spill, locate the source of the leak and take corrective action before an incident becomes a news story. The key is quick detection and accurate location at the source of the leak. TraceTek sensor cable and monitoring systems make it possible. If your business involves the transportation, storage, processing or consumption of hazardous fluids, the possibility of a leak must be considered. Whether your concern is gasoline, jet fuel, diesel, crude oil, acids, bases, contaminated water or any other hazardous liquid, TraceTek can provide a leak detection system tailored to your needs. TraceTek leak detection systems can detect and pinpoint the source of a leak to help you take decisive action long before the spill can ruin your reputation. Reliability Simple detection and location circuit Radiation cross-linked, fluoropolymer materials No exposed metal parts Tens of thousands of installations worldwide in virtually every type of environment Easy installation, simple maintenance Simple, easy to understand alarm panel No field calibration required Self-monitoring for damaged or broken cable Easy to extend or modify in the future Accurate leak location The entire cable is a sensor Leaks are reported to the nearest foot or meter with better than 0.1% precision Instrumentation flexibility Small area, single channel monitoring with relay output Long-length cable monitoring with precise leak location reporting Single circuit / multiple circuit options Alpha numeric user interface Output to host systems via relay contacts, 4-20 ma analog current loop or serial data ports (Modbus or Johnson Controls Metasys format) Multiple circuit capability A single circuit can be as short as 1 meter or as long as 1500 meters TTDM-PLUS Alarm Panel can monitor a single circuit or up to 128 circuits

TraceTek Leak Detection Systems can operate as stand-alone independent alarm systems or they can easily be integrated with: SCADA system Factory Automation Systems Building Management Systems Distributed Control Systems Programmable Logic Controllers A TraceTek Leak Detection System consists of Sensor Cable, Sensor Interface Modules and Alarm Panels. Additional sensor options include: float switches, point probes, pressure switches or any other sensor device that can provide a contact closure. Instrumentation options include: low voltage / relay contact devices, instruments for hazardous locations, battery powered flashing light indicators, and other options tailored to the application. 1

TraceTek Cable: Direct buried applications: Leak Detection and Monitoring for: single wall fuel pipe above ground storage tanks buried valves and fittings TT5000 Fuel Sensor Cable is used to monitor the soil under and around fuel carrying pipes and tanks. The TraceTek system detects and reports the location of a fuel spill before major damage can occur. Leakage rates far below the threshold of a SCADA (Supervisory Control and Data Acquisition) leak detection system can be detected while contaminated soil is still measured in a few cubic meters rather than truckloads. Jet fuel transfer line with blue PVC slotted conduit for TT5000 installed at a major international airport. TT5000 Sensor Cable in PVC conduit can be positioned below buried valves or beneath Aboveground Storage Tank bottoms. The TraceTek system reports the location of a leak to an accuracy of ± 1 meter along the length of a pipeline or beneath a tank floor. The slotted PVC conduit allows the sensor cable to easily be removed and inspected for simple and direct verification of a leak before digging. Detect and locate a leak before damaging the aquifer! 1 hour 4 hour 10 hour 20 hour Above, typical progression of an 8 liter per hour leak The intention is to detect a leak when the affected area is still small and easy to clean up, with a minimum of environmental damage. 2

Interstitial and Indoor applications: Interstitial monitoring for double wall pipe. Indoor monitoring under raised floors, for chemical supply and return piping and other hazardous fluid leak detection. TraceTek 3000 sensor cable is designed to detect waste water, acids, bases, or any liquid that is conductive. Rapid detection, accurate location reporting and excellent chemical resistance make TT3000 a popular choice for double containment pipe systems. TraceTek 5000 is the sensor of choice for fuel piping and underground storage tanks. TraceTek 5000 detects fuel but ignores water. Branch connectors simplify tracing complex manifolds and hydrant systems. Every meter of cable has a unique address so that leaks are detected where they start and repairs can be accurately directed. Wherever complex piping, hazardous chemicals and critical working environments come together, a system to monitor for fluid leakage becomes critical. TT3000 (for conductive liquids) and TT5001 (for organic solvents) are used to monitor the chemical supply systems in semi-conductor manufacturing facilities, pharmaceutical plants, and similar high-value facilities that demand excellent environmental monitoring. TraceTek cable provides the flexibility to monitor long runs of pipe or a single valve box where visual inspection is difficult or impossible. Precise location reporting assists in rapid and accurate dispatch of emergency response teams. 3

TraceTek Technology: TraceTek Technology and System Components TraceTek Sensor Cables are made with materials that have excellent chemical resistance. The TT3000 sensor cable uses conductive polymer-coated wires separated by the solid Kynar insulated core. TT3000 is quick to reset when removed from a spill because the solid core resists accumulation of liquids and contaminants. TT3000 sensor cable detects conductive liquids such as waste water, acids, bases, cooling water etc. TT7000 sensor cable is similar to TT3000, but is sensitive only to strong acids and bases. TT3000 TT5000 sensor cable is designed to detect and locate liquid hydrocarbon fuel spills. The material properties of the core and jacket materials allow the cable to detect and locate liquid fuels such as gasoline, jet fuel and diesel while at the same time completely ignoring water. TT5001 sensor cable is similar to TT5000, but is sensitive to organic solvents. TT5000 TTDM-PLUS Alarm Panel can act as a stand alone leak detection control panel or as the display and user interface for a multiple circuit network of leak detection circuits. TTSIM-1 Sensor Interface Module is the key component of multiple circuit leak detection networks. Leak detection information and cable status is digitized and transmitted to a TTDM-PLUS panel for display or directly transmitted to Factory Automation Systems, PLC s, DCS etc. TTC-1 is a good choice when a short length of sensor cable is used to monitor a small area and a simple relay contact is sufficient. TTDM-PLUS TTSIM-1 Other TraceTek monitoring options include: TTA TTG TT-FLASHER TTSA For small area monitoring in hazardous locations Multiple sensor cables (4 or 12 circuits) in hazardous locations Battery powered, flashing light indicator for hydrocarbon leak detection For small area monitoring in non-hazardous locations 4 TTC-1

System integration and telemetry options: Relay Contacts TraceTek instruments are available with leak alarm and trouble contacts for signaling a host system. 4-20 ma analog current TTDM-PLUS has an analog output. The installer can adjust scaling and channel assignment through simple menu commands. Serial Data Port TTDM-PLUS and TTSIM offer full data access via the Modbus (J-Bus) protocol. TTDM-PLUS has a user selectable RS232 or RS485 serial port. TTSIM is RS485 only. Telemetry The standard connection method between TTDM- PLUS and TTSIM s is twisted-pair copper wire. When network distances increase beyond 1200 meters there are other options available including: fiber optics, spread spectrum radios and cell phone-based alarm reporting. For a single small area, a TTC-1 can provide relay contact output to a PLC or building management system. The combination of sensor cable and a TTC makes an effective drip tray monitoring system. Knowing the leak location is important when the size of the monitored area gets larger and when the sensor cable is concealed by walls or raised floors. TTDM-PLUS and the TraceTek sensor cable provide excellent detection and location performance with accuracy to 1 meter. For clean rooms and similar building applications a single TTDM-PLUS alarm panel can monitor the entire facility for hazardous liquid spills. Here several TTSIM units are monitoring specific areas while the TTDM-PLUS monitors the entire network. TT5000 can be installed along a buried pipeline using a cluster of 4 TTSIM units mounted in a single enclosure. Power points are required approximately every 5 to 6 kilometers. 5

TraceTek and Tyco Thermal Controls The TraceTek Leak Detection and Locating System was developed by Raychem Corporation in the mid 1980s. The TraceTek Products Group became part of Tyco Thermal Controls when Raychem Corporation was aquired by Tyco International in 1999. Tens of thousands of TraceTek systems have been installed over the years in a variety of leak detection applications ranging from water detection in commercial buildings to hazardous fluid monitoring to leak detection for fuel storage and transportation systems. The versatility of the TraceTek technology lends itself to customized designs that detect and locate liquid leaks and spills before equipment or environmental damage becomes significant. Whether it s a matter of personnel safety, the need for 24/7 reliability, or avoiding expensive environmental clean-up costs and penalties, the TraceTek system can be a key element of your facility operating and security systems. Tyco Thermal Controls is an ISO 9001 Certified Development and Manufacturing Facility with sales and support operations in over 40 countries around the world. Distributed By: For more information see: www.tracetek.com www.tycothermal.com Or contact us at one of these locations: U.S.A. Tyco Thermal Controls 300 Constitution Drive Menlo Park, CA 94026-1164 USA Tel: (800) 545-6258 Fax: (650) 474-7215 Europe Tyco Thermal Controls Staatsbaan 4A 3210 Lubbeek Belgium Tel: (32) 16/213-571 Fax: (32) 16/213-600 Asia Tyco Thermal Controls 9th floor, Yeul-chon Building, 24-1, Yeoido-Dong, Youngdeungpo-ku 150-010 Seoul, Korea Tel: (82) 2-2129-7731 Fax: (82) 2-785-4700 Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. TRACETEK and TYCO are trademarks of Tyco Thermal Controls, LLC or its affiliates. Printed on recycled paper 2002 Tyco Thermal Controls LLC Printed in USA H57065 7/02 MODBUS is a registered trademark of Schneider Automation Inc. METASYS is a trademark of Johnson Controls, Inc. KYNAR is a registered trademark of Atofina.

TraceTek TTDM CH01 SIM SIM Normal 13-May-2002 15:30 13 14 15 16 17 20 21 22 23 24 RS RS+ AC AC TTSIM-1 Leak Location Module RATING: 24Vac ±10% 50/60 Hz 3VA Network Address RS RS+ AC AC RED GRN YEL BLK GND 8 9 10 11 12 TraceTek TTDM CH01 SIM SIM Normal 13-May-2002 15:30 13 14 15 16 17 20 21 22 23 24 RS RS+ AC AC TTSIM-1 Leak Location Module RATING: 24Vac ±10% 50/60 Hz 3VA Network Address RS RS+ AC AC TTDM-128 TraceTek Leak Detection Master Module Easy setup and simple operation The TTDM-128 module directly monitors up to 1500 m (5000 ft) of sensor cable and a network of up to 128 remote TraceTek modules. The remote modules may be a combination of sensor interface modules (TTSIM), relay modules (TT-NRM) or additional TTDM-128 modules. With its networking capability, the TTDM-128 provides tremendous fl exibility in terms of system layout options and monitoring capability. When liquid is detected on any of the sensors, the TTDM-128 sounds an alarm, closes relay contacts, turns on a front panel LED and displays the circuit identifi cation and location of the leak on the alphanumeric display. The leak detection event is logged to a nonvolatile event history fi le. All status and event information is made available via the front panel keyboard or RS232/RS485 modbus digital communication to a host computer, PLC or plant/building automation system. Each sensor circuit detects, locates and tracks leaks independently from any other circuits connected to the TTDM-128. There is no loss of sensitivity and no re-mapping required after an initial leak is detected. A simple map showing where the sensors are installed is the only fi eld calibration requirement. Design Features Multiple event tracking capability for up to 128 independent sensor circuits. Summary relay contacts, LED status lights, LCD information display at the TTDM-128 panel. Standard external interface modes include: dry contacts, and RS232/RS485 modbus communication. A 4-20 ma analog output option is available. Event history accessible from the front panel or via serial port to identify type of event, time, location, and other parameters for all sensor events or user adjustments and interventions. Layered password protection for setup changes. Adjustable sensitivity and selectable measurement units. Universal power supply for 120/240 Vac 50/60 Hz (24 volt option available). Non-volatile memory for event history, setup and network confi guration. Complete remote operation and monitoring through modbus communications or using optional TT-SUPERVISOR Windows software. 20 mm (0.79 in) 300 mm (11.81 in) 261 mm (10.28 in) 20 mm (0.79 in) 85 mm (3.35 in) 25 mm (1 in) CH01 SIM SIM Normal TraceTek TTDM 200 mm (7.87 in) 240 mm (9.45 in) 7mm(5/16in)mountinghole(4places) SHLD SHLD RED GRN YEL BLK GND 8 9 10 11 12 TraceTek Network Arrangement TTDM-128 Master Module TTSIM Sensor Interface TTDM-128 SHLD TTSIM To additional TTDMs, TTSIMs or TT-NRMs SHLD RS-232 or RS-485 modbus link to host system RS-485 2 wire network Detection cable /sensors General Features Sensor compatibility All TraceTek sensor cables and point sensors or contact closure devices Maximum size of network Number of TTSIM modules 128 (less number of TT-NRMs installed) Maximum number of TT-NRM 10 Precision ± 0.1% of circuit length Units Feet, meters or zones Display language English, French, German, Spanish, Japanese, Italian Ordering Information Catalog Number Supply voltage TTDM-128 115 V + 15%, - 20% ; 230 V ± 10% ; 50/60 Hz TTDM-128-24V 24 V AC + 5%, - 35% ; 24 V DC ± 20% Accessories TT-NRM Network relay module TTSIM-1 Network sensor interface module TTSIM-1A Network sensor interface module with relay TTDM-4/20 4-20 ma analog output board TT-SUPERVISOR Windows based PC software

TraceTek TTDM CH01 SIM SIM Normal 13-May-2002 15:30 TraceTek TTDM CH01 SIM SIM Normal 13-May-2002 15:30 TTDM-128 Leak Detection Master Module 4 line x 20 character backlit LCD display Four LEDs (monitoring, service, leak, fault) User Interface Ribbon board cable Optional 4-20 ma board Sensor Interface board Mother board Power supply board TraceTek TTDM CH01 SIM SIM Normal PRI: 220 SEC:17 Membrane keypad Painted steel NEMA 12 enclosure Test port RS-485 for SIM network RS-232/485 host port Service required relay Leak relay Fault relay Power Environmental Storage Temperature -18 C to 60 C (0 F to 140 F) Operating temperature 0 C to 50 C (32 F to 122 F) Humidity 5% to 95% non-condensing Audible Alarm Piezo electric Power consumption TTDM-128 Less than 6 VA (5 W) TTDM-128-24V Less than 12 VA (10 W) Interfaces Relays Number: 3 (service required, leak, fault) Type: DPDT Ratings: 5 A at 250 V AC / 24 V DC TraceTek Network Port RS-485 (2 wire) External Serial Port (to host) RS232 (3 or 5 wire) or RS485 (2 wire) Approvals and certifications The TTDM-128 unit is approved for use in ordinary areas. The module must be located in an ordinary area, but may monitor intrinsically safe TraceTek sensors located in hazardous locations, as shown below. LISTED 76LJ SIGNAL SYSTEM UNIT TYPE NM TTDM-128 Ordinary area Class I, Division 2 Hazardous Location TraceTek sensors in Class I, Division 2, Groups A, B, C, D Hazardous Locations (Zone 2 in Europe). Leader or jumper cable Sensor cable PRODUCT SERVICE geprüfte Sicherheit Electromagnetic compatibility Tyco Thermal Controls 300 Constitution Drive Menlo Park, CA 94025-1164 USA Tel: (800) 545-6258 Fax: (650) 474-7517 E-mail: info@tycothermal.com www.tycothermal.com TTDM-128 EUR USA JPN Leader or jumper cable Ordinary Area Zener Barrier Class I, Division 1 Hazardous Location Sensor cable If protected by an agency approved zener barrier, TraceTek sensors in Class I, Division 1, Groups A, B, C, D Hazardous Locations (Zones 0 and 1 in Europe). Contact Tyco Thermal Controls to select proper zener barrier. The TTDM-128 enclosure is NEMA 12 (IP 54). Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranty as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product. Specifi cations are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notifi cation to Buyer to processing or materials that do not affect compliance with any applicable specifi cation. TraceTek and Tyco are trademarks of Tyco Thermal Controls LLC or its affi liates. 2003 Tyco Thermal Controls LLC H56859 1/03

R TT3000 TraceTek Sensing Cable for Conductive Liquids TraceTek TT3000 sensing cable detects the presence of conductive liquids at any point along its length. Most acids and bases and even deionized water can be sensed and located. Installed with a TraceTek alarm and locating module, the cable senses the presence of fluid, triggers an alarm, and pinpoints the location. Distributed sensing TT3000 sensing cable provides distributed leak detection and location over a wide range of areas. The cable is available in a variety of lengths to provide as much coverage as needed. Design flexibility TT3000 sensing cable is available with factory-installed metal connectors that plug together. The measurement circuit is not dependent upon the conductivity of the leaking fluid. Therefore, the same cable will detect a wide range of fluids without special design considerations or calibration. The cable is designed for a variety of applications, including floor surfaces, subfloors, equipment locations, pipes, storage tanks, and trenches. The cable is small, lightweight, and flexible, allowing easy installation. The smooth design allows quick drying. Advanced technology Raychem s conductive-polymer technology and fluoropolymer construction make TT3000 sensing cable mechanically strong and chemically resistant. The cable is constructed of two sensing wires, an alarm signal wire, and a continuity wire embedded in a fluoropolymer carrier rod. This rugged construction exposes no metal, and enables the cable to be reusable even in corrosive environments. Ordering information TT3000 zone sensing cable with factory-installed connector and end termination TT3000 Zone MC 5-ft (1.5 m) sensing cable with preinstalled heat-shrink end termination TT3000 modular sensing cables with factory-installed connectors TT3000 0.3M/1FT MC TT3000 1M/3FT MC TT3000 1.5M/5FT MC TT3000 3M/10FT MC TT3000 4.5M/15FT MC TT3000 7.5M/25FT MC TT3000 15M/50FT MC TT3000 30M/100FT MC 1-ft (0.3 m) sensing cable 3-ft (1 m) sensing cable 5-ft (1.5 m) sensing cable 10-ft (3 m) sensing cable 15-ft (4.5 m) sensing cable 25-ft (7.5 m) sensing cable 50-ft (15 m) sensing cable 100-ft (30 m) sensing cable TT3000 bulk sensing cable (connector kits required) for installation in double-containment piping TT3000 SC Connector kits (not shown) TT3000 CK MC M/F TT3000 CK MC M TT3000 CK MC F Bulk sensing cable on reel, Minimum length: 250 ft (75 m) Maximum length: 1000 ft (300 m) Components for five mated pairs of connectors (includes test tools) One pin-type connector One socket-type connector

TT3000 Sensing Cable for Conductive Liquids Continuity wire (red) Fluoropolymer carrier Continuity wire (red) Fluoropolymer carrier 0.52 in. (13 mm) 0.24 in. (6 mm) nominal Sensing wire (black) Sensing wire (black) Signal wire (yellow) Sensing wires (black) Signal wire (yellow) Drawing not to scale Product characteristics Cable diameter 0.24 in. (6.0 mm) nominal Cable diameter with connecter 0.52 in. (13 mm) nominal Continuity and signal wires 2 x 26 AWG with insulation of fluoropolymer Sensing wires 2 x 30 AWG with jacket of conductive fluoropolymer Carrier Fluoropolymer Cable weight (50-ft length) 2.3 lb Technical Information Breaking strength 160 lb Cut-through force >50 lb with 0.005 in. blade; crosshead speed 0.2 inch/minute Abrasion resistance >65 cycles per UL 719 Maximum continuous operating temperature Sensing cable: 194 F (90 C) Cable connectors: 185 F (85 C) Chemical resistance Cable functions normally after Trichloroethylene (100%) exposure in accordance with Sulphuric acid (98%) ASTM D 543 at 77 F (25 C) Hydrochloric acid (37%) for seven days: Hexane (100%) Methanol (100%) Sodium hydroxide (10%) Xylene (100%) Aqua regia Note: Prolonged exposure to concentrated ketones may cause temporary reduction of sensitivity; consult factory. Radiation resistance Approvals R LISTED ISO 9001 F M APPROVED Cumulative radiation exposure of 10 megarad gamma radiation over design life of 30 years. Raychem Corporation Commercial & Industrial Infrastructure Division 300 Constitution Drive Menlo Park, CA 94025-1164 Tel (800) 545-6258 Fax (800) 611-2323 Fax-on-Demand (800) 329-4494 ciinfo@raychem.com www.raychem.com Sensing cable may be used in Class I, Division 2, Groups A, B, C, D Hazardous Locations. If wiring from module meets requirements for intrinsic safety, sensing cable may be used in Class I, Division 1, Groups A, B, C, D Hazardous Locations (Zone 0 or Zone 1 in Europe). The TraceTek products group is a part of Raychem Chemelex Division. Chemelex Division is ISO 9001 certified. All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Raychem makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Raychem s only obligations are those in the Raychem Standard Terms and Conditions of Sale for this product, and in no case will Raychem be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Raychem reserves the right to make changes without notification to Buyer to materials or processing that do not affect compliance with any applicable specification. 1990 Raychem Corporation Printed in USA H53829 10/96 TraceTek is a trademark of Raychem Corporation.

R TT5000 TraceTek Fuel-Sensing Cable TraceTek TT5000 sensing cable detects the presence of liquid hydrocarbon fuels at any point along its length, yet does not react to the presence of water. Installed with a TraceTek alarm and locating module, the cable senses the liquid, triggers an alarm, and pinpoints the location of the leak. Distributed sensing TT5000 sensing cable provides distributed leak detection and location for a wide range of applications. The cable is available in a variety of lengths to provide as much coverage as needed. Design flexibility TT5000 sensing cable is available in bulk reels, with connector kits or with factoryinstalled connectors that plug together. The cable is designed for a variety of double-containment applications, including tanks, trenches, and piping. (See the TraceTek Double-Containment Design Guide for specific design alternatives.) Advanced technology Raychem s radiation-crosslinking and conductive-polymer technologies are used to make TT5000 sensing cable mechanically strong and chemically resistant. The core of the cable is constructed of two sensing wires, an alarm signal wire, and a continuity wire. The core is encased in a conductive-polymer jacket and surrounded with a fluoropolymer braid. This rugged construction allows the cable to perform reliably in the most demanding environments. Ordering information TT5000 zone sensing cable with factory-installed connector and end termination TT5000 Zone MC 5-ft (1.5 m) sensing cable with heat-shrink end termination. TT5000 modular sensing cables with factory-installed connectors TT5000-0.3M/1FT-MC 1-ft (0.3 m) sensing cable TT5000-1.5M/5FT-MC 5-ft (1.5 m) sensing cable TT5000-3M/10FT-MC 10-ft (3 m) sensing cable TT5000-4.5M/15FT-MC 15-ft (4.5 m) sensing cable TT5000-7.5M/25FT-MC 25-ft (7.5 m) sensing cable TT5000-15M/50FT-MC 50-ft (15 m) sensing cable TT5000-30M/100FT-MC 100-ft (30 m) sensing cable TT5000 bulk sensing cable (connector kits required) for installation in double-containment piping TT5000 SC Connector kits (not shown): TT5000 CK MC M/F TT5000 CK MC M TT5000 CK MC F Bulk sensing cable on reel Minimum length: 100 ft (30 m) Maximum length: 800 ft (240 m) Components for five mated pairs of connectors (includes test tools) One pin-type connector One socket-type connector

R TT5000 Fuel-Sensing Cable 0.28 in. (7 mm) Fluoropolymer braid Continuity wire (red) Spacer wire (white) Signal wire (yellow) 0.52 in. (13 mm) Conductive polymer jacket Sensing wires (black) Drawing not to scale Product characteristics Cable diameter 0.28 in. (7 mm) nominal Cable diameter with connector 0.52 in. (13 mm) nominal Cable weight (50-ft length) 2.4 lb Operating temperature range 20 C to 60 C ( 4 F to 140 F) Pull force limit Not to exceed 50 lb Bend radius 2 in. (50 mm) minimum Pressure Loads greater than 20 lb (9 kg) per linear inch at 20 C (68 F) may immediately trigger an alarm. Nonresettable Must be replaced after exposure to hydrocarbon liquids. Chemical resistance Cable functions normally after exposure Sulfuric acid (10%) in accordance with ASTM D 543 Hydrochloric acid (10%) at 23 C (73 F) for seven days: Nitric acid (10%) Sodium hydroxide (10%) Water resistance Sensing cable Less than 10-µA leakage when immersed in salt water for 90 days. Connector system Less than 10-µA leakage when immersed in water at 10 psig for 24 hours. Response time Representative materials detected: Typical response time at 20 C (68 F): Gasoline 12 minutes #1 diesel fuel 60 minutes #2 diesel fuel 120 minutes JP5 jet fuel 70 minutes JP8 jet fuel 50 minutes Jet-A jet fuel 50 minutes Xylene 20 minutes Approvals LISTED ISO 9001 F M APPROVED Notes: Response Time Test Method: Test Procedures for Third Party Evaluation of Leak Detection Methods; Cable Sensor Liquid Contact Leak Detection Systems. Response times are affected by operating temperature. Consult factory for specific response times at other temperatures and in other liquids. Sensing cable may be used in Class I, Division 2, Groups A, B, C, D Hazardous Locations. If wiring from module meets requirements for intrinsic safety, sensing cable may be used in Class I, Division 1, Groups A, B, C, D Hazardous Locations (Zone 0 or Zone 1 in Europe). The TraceTek products group is a part of Raychem Chemelex Division. Chemelex Division is ISO 9001 certified. Raychem Corporation Commercial & Industrial Infrastructure Division 300 Constitution Drive Menlo Park, CA 94025-1164 Tel (800) 545-6258 Fax (800) 611-2323 Fax-on-Demand (800) 329-4494 ciinfo@raychem.com www.raychem.com All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Raychem makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Raychem s only obligations are those in the Raychem Standard Terms and Conditions of Sale for this product, and in no case will Raychem be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Raychem reserves the right to make changes without notification to Buyer to materials or processing that do not affect compliance with any applicable specification. 1994, 1995 Raychem Corporation Printed in USA H54785 10/96 TraceTek is a trademark of Raychem Corporation.

R TT7000 TraceTek Sensing Cable for Strong Acid TraceTek TT 7000 sensing cable detects the presence of strong acid at any point along its length.most acids can be sensed and located. Installed with a TraceTek alarm and locating module, the cable senses the presence of fluid, triggers an alarm, and pinpoints the location. Distributed sensing TT7000 sensing cable provides distributed leak detection and location over a wide range of areas. The cable is available in a variety of lengths to provide as much coverage as needed. Design flexibility TT7000 sensing cable is available with factory-installed metal connectors that plug together. The measurement circuit is not dependent upon the conductivity of the leaking fluid. Therefore, the same cable will detect a wide range of fluids without special design considerations or calibration. The cable is designed for a variety of applications, including, equipment locations, direct bury pipes, double containment pipes,storage tanks, and trenches. The cable is small, lightweight, and flexible, allowing easy installation. Advanced technology Raychem s conductive-polymer technology and fluoropolymer construction make TT7000 sensing cable mechanically strong. The cable is constrcted of two sensing wires, an alarm signal wire, and a continuity wire embedded in a fluoropolymer carrier rod. This rugged construction exposes no metal, and enables the cable to be reusable even in corrosive environments. Ordering information TT7000 zone sensing cable with factory-installed connector and end termination TT7000 Zone MC 5-ft (1.5 m) sensing cable with preinstalled heat-shrink end termination TT 7000 modular sensing cables with factory-installed connectors TT7000 0.3M/1FT MC TT7000 1M/3FT MC TT7000 1.5M/5FT MC TT7000 3M/10FT MC TT7000 4.5M/15FT MC TT7000 7.5M/25FT MC TT7000 15M/50FT MC TT7000 30M/100FT MC 1-ft (0.3 m) sensing cable 3-ft (1 m) sensing cable 5-ft (1.5 m) sensing cable 10-ft (3 m) sensing cable 15-ft (4.5 m) sensing cable 25-ft (7.5 m) sensing cable 50-ft (15 m) sensing cable 100-ft (30 m) sensing cable TT7000 bulk sensing cable (connector kits required) for installation in double-containment piping TT7000 SC Connector kits (not shown) TT7000 CK MC M/F TT7000 CK MC M TT7000 CK MC F Bulk sensing cable on reel, Minimum length: 250 ft (75 m) Maximum length: 1000 ft (300 m) Components for five mated pairs of connectors (includes test tools) One pin-type connector One socket-type connector

TT7000 Sensing Cable for Conductive Liquids Continuity wire (red) Fluoropolymer carrier Continuity wire (red) Fluoropolymer carrier 0.52 in. (13 mm) 0.24 in. (6 mm) nominal Sensing wire (black) Sensing wire (black) Signal wire (yellow) Sensing wires (black) Signal wire (yellow) Drawing not to scale Product characteristics Cable diameter 0.24 in. (6.0 mm) nominal Cable diameter with connecter 0.52 in. (13 mm) nominal Continuity and signal wires 2 x 26 AWG with insulation of fluoropolymer Sensing wires 2 x 30 AWG with jacket of conductive fluoropolymer & coated nylon / urethan Carrier Fluoropolymer Cable weight (50-ft length) 2.3 lb Technical Information Breaking strength 160 lb Cut-through force >50 lb with 0.005 in. blade; crosshead speed 0.2 inch/minute Abrasion resistance >65 cycles per UL 719 Maximum continuous operating temperature Sensing cable: 194 F (90 C) Cable connectors: 185 F (85 C) Response time Ignore water Sulphuric acid ( 98% ) : 3 ~ 4 min Hydrochloric acid ( 37% ~ ) : 5 min Nitric Acid, Regent grade ( 73% ) : ~ 1 min Commercial grade ( ~67.2% ) : 1 ~ 2 min Radiation resistance Cumulative radiation exposure of 10 megarad gamma radiation over design life of 30 years. Approvals R LISTED F M APPROVED Sensing cable may be used in Class I, Division 2, Groups A, B, C, D Hazardous Locations. If wiring from module meets requirements for intrinsic safety, sensing cable may be used in Class I, Division 1, Groups A, B, C, D Hazardous Locations (Zone 0 or Zone 1 in Europe). ISO 9001 The TraceTek products group is a part of Raychem Chemelex Division. Chemelex Division is ISO 9001 certified. Raychem Corporation Commercial & Industrial Infrastructure Division 300 Constitution Drive Menlo Park, CA 94025-1164 Tel (800) 545-6258 Fax (800) 611-2323 Fax-on-Demand (800) 329-4494 ciinfo@raychem.com www.raychem.com All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Raychem makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Raychem s only obligations are those in the Raychem Standard Terms and Conditions of Sale for this product, and in no case will Raychem be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Raychem reserves the right to make changes without notification to Buyer to materials or processing that do not affect compliance with any applicable specification.