INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

Similar documents
INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

TA-300, TA-300-LF, TA-350, TA-350-LF

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

MEGATRON MODEL 2, 3, 4, and 5

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

HOT INLET COLD INLET INSTALLATION

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

OUTLET LEONARDH THERMOSTATIC INSTALLATION

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

OUTLET LEONARD THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

MEGATRON MODEL TA, TA-LF

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

Installation Instructions / Warranty

Installation S

Installation S

Installation S

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation S

Installation S

Installation Instructions / Warranty. Metris 31060XX XX XX1

Installation Instructions / Warranty. Massaud

Installation Instructions / Warranty. PuraVida 15775XX1

INSTALLATION INSTRUCTIONS

1. Connect Hose Attach a garden hose to the swivel nut hose fitting.

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

INSTALLATION, OPERATION AND MAINTENANCE

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model /8320CRP Shower and Eye/Face Wash

Installation Instructions / Warranty

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

User Manual. Hot Water Dispenser. Models: 177HWD15G 12/2018. Please read and keep these instructions. Indoor use only.

TUB AND SHOWER FAUCET

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation Instructions

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Installation Manual. Models 99168, 99169, 99170

Model Combination Shower Eye/Face Wash

Instruction Manual. Cheese Warmer with Pump

INSTALLATION AND OPERATING INSTRUCTIONS

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Model 8356WCC Pull-Down Shower Eye/Face Wash

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Installation Instructions / Warranty

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS


ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

MINIATURE THERMOSTATIC VALVE

INSTALLATION & TESTING MANUAL

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

TIMES SQUARE TWO-HANDLE THERMOSTAT

Installation Instructions / Warranty. Starck 10111XX XX XX1

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Thermostatic Concealed Shower Valve

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain

Transcription:

C ASSE 1017 BULLETIN G-6B March 2009 INSTALLATION SETUP AND OPERATING INSTRUCTIONS WATER SYSTEM * TM-500A, TM-550A IMPORTANT! Provide valve serial number (located on valve body) when ordering parts!! *ASSE 1071 Certified Starting with TM551A, TM552A, TM553A,.. Compliance ANSI Z 358-1 2004 THERMOMETER OUTLET INLINE CHECK C CHECKSTOPS REDUNDANT PRIMARY * TM-500A TM-550A INSTALLATION 1. Valve should be installed at a location where it can easily be cleaned, adjusted or repaired. 2. The inlets are clearly marked on the valve body casting. Connect the hot water into the inlet marked "" and cold water into the inlet marked "." These are NOT to be confused with the "C-H" markings on the front cover. 3. Use solder or pipe cement sparingly. Supply pipes should be flushed before the valve is connected. Flush outlet pipe and valve as soon as it is connected. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. NOTE: TM-500A and TM-550A are designed for multiple face/eye washes and not to be used for drench shower applications. CAUTION IMPORTANT! These systems are designed to provide mixed water from 60 to 90 (15 to 32 C) for eye/face wash applications only. Call Leonard for systems designed to operate at temperatures outside of this range. REMEMBER! THIS IS A CONTROL SYSTEM WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD MGR-1000). 1360 Elmwood Avenue, Cranston, RI 02910 USA Phone: 401.461.1200 Fax: 401.941.5310 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com

ASSE 1017 ADJUSTMENT AND SERVICE Leonard Type TM Thermostatic Water Mixing Valves are simple in design and may be easily cleaned, adjusted and repaired. If the installation is accessible, servicing may be completed without disconnecting the valve. Leonard Type TM Thermostatic Water Mixing Valves are simple in design and may be easily cleaned, adjusted and repaired. If the installation is accessible, servicing may be completed without disconnecting the valve. TO RESET ADJUSTABLE HIGH TEMPERATURE LIMIT STOP: POINTER SCREW FINE ADJUSTMENT SCREW WEB POINTER (REST STOP AGAINST SCREW) STOP LTR SET SCREW 1. Loosen LTR Set Screw, remove POINTER SCREW. 2. Adjust POINTER to maximum desired temperature. 3. Remove POINTER, replace POINTER on spline rod with STOP (which is cast into the underside on the pointer), resting against the BOTTOM side of the WEB on the FINE ADJUSTMENT SCREW. 4. If fine adjustment is needed, adjust FINE ADJUSTMENT SCREW on the cover, loosen for hotter or tighten for cooler temperature. 5. Replace POINTER and check temperature, if set to desired temperature replace POINTER SCREW, and tighten LTR SET SCREW. 6. The new maximum temperature has now been set. Test this temperature by holding a thermometer under the flow of water to be certain it is as desired. * LIMIT STOP MUST BE RESET AND RECHECKED EACH TIME HANDLE IS REMOVED. WARNING WARNING! This Thermostatic Mixing Valve has an adjustable high temperature limit stop, which must be checked. If temperature is too high, the installer MUST RESET this stop immediately. Always check the temperature of the mixed water when the lever handle is turned to full. Excessively hot water is DANGEROUS AND MAY CAUSE SCALDING! The high temperature limit stop is factory set at approximately 90 (32 C) with an incoming hot water supply temperature of 135 (57 C). If the incoming hot water on the job is higher than 135 (57 C), the valve when turned to full hot will deliver water in excess of 90 (32 C) and the high temperature limit stop MUST BE RESET BY THE INSTALLER. TROUBLESHOOTING INSTRUCTIONS PARTS REQUIRED: PACKINGS S & 1. Leak at pointer rod. 2. Leak between valve cover and base. KIT# 1/26 (PACKINGS & S) PORT SLEEVE ASSEMBLY THERMOSTAT GROUP 3. Valve delivers all cold water, or will not mix consistently. 4. After cleaning or replacing port sleeve assembly, valve will not hold temperature. KIT# R/25M (REBUILDING KIT) OR TM25M-1-8B BRIDGE ASSEMBLY KIT# R/25M (REBUILDING KIT) OR TM25M-G2 THERMOSTAT GROUP CHECKSTOPS 5. Hot water bypass into cold line. 6. Supplies cannot be shut off completely. KIT# 4/M20 (CHECKSTOP KIT) 7. Leak at checkstop bonnet. SEE PAGE 5 FOR COMPLETE PARTS BREAKDOWN, PARTS KITS Check for significant variations in outlet flow. Thermostatic valves will NOT provide the desired accuracy outside of their flow capacity range. Minimum flows must be no less than shown (see Flow Capacities, page 6). If installed on a circulated hot water system, make certain the valve is piped according to Leonard Required Methods of Piping (see page 3). REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS. (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000). 2

REQUIRED METHOD OF PIPING TM VALVE C ASSE 1017 METHOD #1 Required when hot water is to be circulated to a thermostatic mixing valve, which is a substantial distance from the hot water source. OUTLET (THIS PIPING IS NOT TO BE USED FOR AN ENTIRE BUILDING!) CIRCULATE WATER FROM END OF LINE BACK TO TANK SUPPLY SUPPLY C OUTLET SECONDARY SUPPLY SUPPLY (THIS PIPING IS NOT TO BE USED FOR AN ENTIRE BUILDING!) CIRCULATE WATER FROM END OF LINE BACK TO TANK TM-500A PRIMARY TM-550A ADJUSTMENT SCREW The TM-550 Redundant Thermostatic Mixing Valve has been factory set at 90 (32 C). This set point can be field adjusted with a 3/8 wrench (see diagram). Clockwise direction will increase temperature. Maximum set point is 100 (38 C). REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS. (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000). This unit must be cycled each time the emergency equipment is checked. See ANSI Z358.1-1990, Maintenance and Training section: 1. Cycle redundant thermostatic valve by loosening the pointer set screw and setting the primary thermostatic mixing valve to full hot. (TM-550 only) 2. Open eye/face wash and allow temperature to reach the set point. 3. Turn primary thermostatic valve to full cold and wait ten seconds. 5. Check to be sure outlet temperature does not climb above 90 (32 C) 6. Turn primary thermostatic mixing valve to full cold and wait ten seconds. 7. Set primary thermostatic mixing valve to the desired temperature and close eye/face wash. 4. Turn primary thermostatic valve to full hot and wait for ten seconds. 3

INSTRUCTIONS FOR DISMANTLING VALVE (DWG. 1) 1. Shut off hot and cold supplies to valve. 2.Remove four Cover Screws M-20-2C to release entire thermostatic control assembly. 1. M20-2C SCREWS WHEN RE-ASSEMBLING VALVE, insert Cover Gasket M-20-3C in base. Lubricate TM- 28-6B O'Rings before re-inserting assembly. After installing new parts, it will probably be necessary to reset high temperature limit. See instructions "TO RESET ADJUSTABLE HIGH TEMPERATURE LIMIT STOP" (page 2). TO REMOVE BRIDGE ASSEMBLY (DWG. 2) HOLDER NUT O'RING Remove MU-10B Pointer Rod Nut, remove TM25M-1-8B Bridge Assembly from pointer rod. Failure to properly blend the water may be caused by a sticking condition in the TGM-1/25M Port Sleeve Assembly. The Thimble should slide freely on the Port Sleeve. Clean with a NON-CORROSIVE CLEANING AGENT AND SOFT CLOTH. DO NOT USE ABRASIVES, then wash parts thoroughly. 2. TM-25M-1-8B BRIDGE ASSY To reassemble, replace Bridge Assembly on pointer rod. Driving ball on Thimble MUST engage hole in coil bracket. Replace pointer rod nut. DO NOT apply grease or lubricants to the TGM-1/25M Port Sleeve Assembly. MU-10B POINTER ROD NUT TO DISASSEMBLE BRIDGE ASSEMBLY (DWG. 3) Remove TM25-3A Holder Nuts using a screwdriver in the slots provided. Clean or replace TGM-1/25M Port Sleeve Assembly following instructions above. When reassembling, check TM25-3B port sleeve packings and replace if necessary. TO CLEAN OR REPLACE THERMOSTAT GROUP Remove stop retaining ring and stop. Loosen gland nut. Push rod through cover. BE CAREFUL NOT TO PULL THERMOSTAT COIL OUT OF SHAPE. To clean, if a deposit has collected on the thermostat group, brush in a non-corrosive cleaning solution. Rinse in clean water and replace in cover with parts as shown. 3. TM-25-3A P.S. HOLDER NUT HOLDER NUT O'RING TM-25-5 BRIDGE TM-25-3 P.S. HOLDER TGM-1/25M PORT SLEEVE ASSEMBLY TM-25-3B P.S. PACKING M20-1C 57-D GLAND NUT 4. MU-10B POINTER ROD NUT M20-4C GLAND PACKING (2 REQD) TM25M-G2 THERMO GROUP To replace entire Thermostatic Control Assembly specify TM-25M-1-12B NOTE: AFTER INSTALLING NEW PARTS IT WILL BE NECESSARY TO RESET THE ADJUSTABLE HIGH TEMPERATURE LIMIT STOP (SEE PAGE 2). REMEMBER: THIS IS A CONTROL DEVICE, WHICH MUST BE CLEANED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD, MGR-1001). 4

TM-500A, 550A VALVE PARTS POINTER SCREW 7520 LTR SET SCREW 6910 57-D GLAND NUT 214 7628 POINTER TM25M-1-8B BRIDGE ASSEMBLY MU-4C GLAND PACKING TM-25-3A P.S. HOLDER NUT HOLDER NUT O'RING TM25-5 BRIDGE TM25M-G2 THERMOSTAT GROUP TM25-3B P.S. PACKING MU-10B POINTER ROD NUT TM25-3 P.S. HOLDER TGM-1/25M PORT SLEEVE ASSEMBLY CHECKSTOP PARTS TO CLEAN THERMOSTAT GROUP Push rod through cover. Be careful not to pull coil out of shape. If a deposit has collected on the thermostat group (TM25M-G2) brush in a non-corrosive cleaning solution. CHECKSTOPS M20-3A BONNET PACKING M20-9A CHECK SPRING M20-6A LOWER STEM & PACKING MU-4A RF/CP UPPER STEM AND PACKING MU-5A UPPER STEM PKG. M20-2A RF/CP CHECK BONNET KIT 1/26 PACKINGS & S MU-4C GLAND PKG. M20-3A BONNET PKG. M20-9A CHECK SPRING HOLDER NUT O'RING M20-6A LOWER STEM & PKG. MU-5A O'RING REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000). NOTE: AFTER INSTALLING NEW PARTS IT WILL BE NECESSARY TO RESET THE ADJUSTABLE HIGH TEMPERATURE LIMIT STOP ON EACH VALVE (SEE PAGE 2). KIT R/25M REBUILDING KIT KIT 4/M20 CHECKSTOP KIT 2 EACH: M20-6A LOWER STEM & PACKING TM-25M-1-12B CONTROL ASSEMBLY MU-5A UPPER STEM O'RING M20-3A BONNET PKG. M20-9A CHECK SPRING 5

55 50 FLOW CAPACITIES TM-500A/550A PRESSURE DROP P.S.I.G. 40 30 20 10 0 2 3 4 5 6 7 8 10 20 30 40 50 60 70 80 100 150 200 MAXIMUM FLOW CAPACITY GALLONS PER MINUTE CAUTION! All thermostatic water mixing valves have limitations. They will not provide the desired accuracy outside of their flow capacity range. Consult the capacity chart and DO NOT OVERSIZE. Minimum flow must be no less than shown below. IMPORTANT! These systems are designed to provide mixed water from 60 to 90 (15 to 32 C) for face/eyewash applications only, these systems are not designed for drench shower applications. Call Leonard for systems designed to operate at temperatures outside of this range. MINIMUM MODEL IN OUT FLOW INTERNAL SYSTEM PRESSURE DROP (GPM) WATER BY-PASS 5 10 15 20 25 L\MIN MINIMUM.3.7 1.0 1.4 1.7 2.1 2.4 2.8 30 35 40 45 50 PSI 3.1 3.4 BAR TM-500A 3/4" 3/4" 3.0 11 8 30 7 26 9 34 12 45 13 16 49 61 18 68 20 76 22 83 24 91 26 98 GPM L\MIN TM-550A 3/4" 3/4" 3.0 11 8 7 9 12 13 30 26 34 45 49 MAXIMUM FLOW CAPACITY 16 18 20 61 68 76 22 83 24 26 GPM 91 98 L\MIN LIMITED WARRANTY Leonard Valve Company warrants the original purchaser that products manufactured by them (not by others) will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with Leonard Valve Company's instructions, for a period of one year from date of shipment. During this period the Leonard Valve Company will at its option repair or replace any product, or part thereof, which shall be returned, freight prepaid, to the Leonard factory and determined by Leonard to be defective in materials or workmanship. There are no warranties, express or implied, which extend beyond the description contained herein. There are no implied warranties of merchantability or of fitness for a particular purpose. In no event will Leonard be liable for labor or incidental or consequential damages. Any alteration or improper installation or use of the product will void this limited warranty. 2009 Leonard Valve Company Printed in USA 6 1360 Elmwood Avenue, Cranston, RI 02910 USA Phone: 401.461.1200 Fax: 401.941.5310 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com