R -OFF- 11. Remote control Setup for remote control. S xxxx I xxxx

Similar documents
Operating manual. Recirculating Coolers FL11006 FLW English. Innovative Temperature Technology

Circulators MV-4/ MV-6/ MV-12/ MV-26 MW-4/ MW-6/ MW-12/ MW-26 MW-Z

Operating manual. Recirculating Coolers. English

Operating manual. English. Cryo-Compact Circulators. The Economy-Series

Operating manual. Recirculating Coolers FL300 FL601. English V2.doc FL300

Operating manual. Recirculating Coolers FLW1703 FL1203. English

Operating manual. Recirculating Coolers FL20006 FLW English

Operating manual. Recirculating Coolers FL300 FL601. English _a.doc FL300

Operating manual. Recirculating Coolers. English

Operating Manual. Visco-Baths ME-31A ME-16G ME-18V. English

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

Operating manual. Recirculating Coolers FLW1703 FL1203. English

Operating Instructions

Operating manual. English. Shaking Water Baths SW22 SW23

SyringeHeater.com. Syringe Heater. Thermo-Kinetic Heat Clamping. Model: HEATER-KIT-1LG HEATER-KIT-5SP

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Ice Rink (Single and Dual Configurations) Custom Control Features

MicroTech Series 200 Centrifugal Chiller

Operating Manual. Refrigerated and Heating Circulators F25-ME F26-ME F32-ME F33-ME F34-ME FP40-ME FP50-ME. English. water-cooled FPW50-ME

Database for CTS6000 MODBUS

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

Operating manual. English

Operating Manual. Refrigerated/Heating Circulators F25-HL F32-HL F33-HL FP35-HL FP40-HL FP45-HL FP50-HL FPW50-HL. English. air-cooled.

Metasys Integrator Compu-Aire Application

Instructions AK-PC 520

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Metasys Integrator Airflow Application

Laptop / PC Programming Manual

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Diagnostics and Monitoring System WEB Tool 2. User Manual

DTSX200 Communications(Modbus) Guide

CBI-064. User Manual. Caddx to KNX-BUS Interface

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

ModBus DE-1 INSTALLATION AND USER MANUAL

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

LineGuard 2300 Program User Manual (FloBoss 107)

Table of Contents SECTION PAGE

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Operating Manual. Refrigerated and Heating Circulators. air cooled F25-HE F32-HE F34-HE FP40-HE FP50-HE FPW50-HE. English.

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Operating Manual. SemiChill Recirculating Coolers. Eco-Serie. SC 5000a air cooled. SC 5000w water cooled. SC 10000w water cooled

MicroTech Series-200 Flooded Screw Chiller

User manual. KNXpar. version

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

Open Protocol Data Communications

1. User features of the GSM dialer

Follett Performance Plus

P2267 NETWORK INTERFACE

TEMPERATURE CONTROL MODULE MODEL R3-TC2

OPERATING MANUAL Enertronic Control System 2

Fire Control Panel FS5100

Oakton TEMP 9500 Advanced Multiparameter Controller

PBI Manual. Paradox to KNX-BUS Interface

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Section 5. Control Systems

Operating Manual. Refrigerated and Heating Circulators. English F12-MA FP35-MA F25-MA FP40-MA F33-MA FP50-MA F32-MA F34-MA FPW50-MA

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Operating Manual. Refrigerated and Heating Circulators. English F12-MA FP35-MA F25-MA FP40-MA F33-MA FP50-MA F32-MA F34-MA FPW50-MA

Sales and Engineering Data Sheet ED

Altitude Chambers.

Operating Manual. Ultra-Low Refrigerated Circulators. English. air-cooled FP52-SL FP55-SL FP90-SL. water-cooled FPW52-SL FPW55-SL FPW90-SL FPW91-SL

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

IntesisBox BACnet/IP Server - Notifier ID3000 series

Option M16.x Configurable I/O extension cards, four multi-inputs (4-20 ma/0-5 V/Pt100) Description of option Functional description

Installer Manual KNX Touchscreen Thermostat

Operating Manual. High Dynamic Temperature System with integrated programmer LH 46 LH85

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

TSI Model 8630 PRESSURA Room Pressure Monitor Modbus Communications Application Note LC-106

Metasys Integrator Cleaver-Brooks Application

User manual. KNXgal. version

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0

USER MANUAL FOR OPERATING SYSTEM

EC2-5x2 Series Condensing Unit Controllers

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

OVEN INDUSTRIES, INC.

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

REPEATER FS5200R INSTRUCTION MANUAL

PARAGON Commercial Refrigeration Controls

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

Series Digital Controller Instruction Sheet

VCM-X / RNE Controller Operator Interface SD Technical Guide

Pre-Cool and Free- Cool Fan Control

CompactConnect. Special Features. Digital Displays/ Input Monitoring

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Sentient. Downloader Manual D4854

OPTIMUM APPLIED SYSTEMS,

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

Model 8682-KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control

Sales and Engineering Data Sheet ED

Manual for the integration in BMS/GTC

Installation & Maintenance

Transcription:

11. Remote control 11.1. Setup for remote control SERIAL R -OFF- S xxxx I xxxx 1. Check the interface parameters for both interfaces (on circulator and PC) and make sure they match. (Serial interface see page 38) 2. In the menu > MENU / CONFIG < set the menu item > SETPoint < to > SERIAL <. (see 7.3.1. SETPOINT Keypad control or remote control on page 35) 3. Connect both units with an interface cable.. Like all parameters which can be entered through the keypad, interface parameters are stored in memory even after the circulator is turned off. 54

ME 11.2. Communication with a PC or a superordinated data system If the circulator is put into remote control mode via the configuration level, the VFD COMFORT-DISPLAY will read R -OFF- = REMOTE STOP. The circulator is now operated via the computer. In general, the computer (master) sends commands to the circulator (slave). The circulator sends data (including error messages) only when the computer sends a query. In remote control mode: After a power interruption the order to start and all values which have to be adjusted must be resent from the personal computer via the interface. AUTOSTART is not possible. A transfer sequence consists of: command space ( ; Hex: 20) parameter (the character separating decimals in a group is the period) end of file ( ; Hex: 0D) The commands are divided into in or out commands. in commands: asking for parameters to be displayed out commands: setting parameters The out commands are valid only in remote control mode. Command to set the working temperature > SETP 1< to 55.5 C out_sp_00 55.5 Command to ask for the working temperature > SETP 1< in_sp_00 Response from the circulator: 55.5 55

Remote control 11.3. List of commands out commands: Setting temperature values or parameters. Command Parameter Response of circulator out_mode_01 0 Use working temperature > SETP 1< out_mode_01 1 Use working temperature > SETP 2< out_mode_01 2 Use working temperature > SETP 3< out_mode_04 0 Temperature control of internal bath. out_mode_04 1 External control with Pt100 sensor. out_mode_05 0 Stop the unit = R OFF-. out_mode_05 1 Start the unit. out_mode_08 0 Set the control dynamics - aperiodic out_mode_08 1 Set the control dynamics - standard out_sp_00 xxx.xx Set working temperature. SETP 1 out_sp_01 xxx.xx Set working temperature. SETP 2 out_sp_02 xxx.xx Set working temperature. SETP 3 out_sp_03 xxx.xx Set high temperature warning limit OVERTEMP out_sp_04 xxx.xx Set low temperature warning limit SUBTEMP out_sp_07 x Set the pump pressure stage. (1... 4) out_par_04 x.x CoSpeed 0... 5.0 Band limit during external control. Setting the maximum difference between the temperatures in the internal bath and external system. out_par_06 xxx Xp control parameter of the internal controller. 0.1... 99.9 out_par_07 xxx Tn control parameter of the internal controller. 0... 9999 out_par_08 xxx Tv control parameter of the internal controller. 0... 999 out_par_09 xxx Xp control parameter of the cascade controller. 0.1... 99.9 out_par_10 xxx Proportional portion of the cascade controller. 1... 99.9 out_par_11 xxx Tn control parameter of the cascade controller. 0... 9999 out_par_12 xxx Tv control parameter of the cascade controller. 0... 999 out_par_13 xxx Maximum internal temperature of the cascade controller. 56

ME Command Parameter Response of circulator out_par_14 xxx Minimum internal temperature of the cascade controller. out_par_15 xxx Band limit (upper) 0... 200 C out_par_16 xxx Band limit (lower) 0... 200 C in commands: Asking for parameters or temperature values to be displayed. Command Parameter Response of circulator version none Number of software version (V X.xx) status none Status message, error message (see page 58) in_pv_00 none Actual bath temperature. in_pv_01 none Heating power being used (%). in_pv_02 none Temperature value registered by the external Pt100 sensor. in_pv_03 none Temperature value registered by the safety sensor. in_pv_04 none Setpoint temperature of the excess temperature protection in_sp_00 none Working temperature SETP 1 in_sp_01 none Working temperature SETP 2 in_sp_02 none Working temperature SETP 3 in_sp_03 none High temperature warning limit OVERTEMP in_sp_04 none Low temperature warning limit SUBTEMP in_sp_07 none Pump pressure stage in_par_01 none Te - Time constant of the external bath. in_par_02 none Si - Internal slope in_par_03 none Ti - Time constant of the internal bath. in_par_04 none CoSpeed - Band limit (max. difference between the temperatures in the internal bath and external system). in_par_05 none Factor pk/ph0: Ratio of max. cooling capacity versus max. heating capacity in_par_06 none Xp control parameter of the internal controller. in_par_07 none Tn control parameter of the internal controller. in_par_08 none Tv control parameter of the internal controller. in_par_09 none Xp control parameter of the cascade controller. 57

Remote control Command Parameter Response of circulator in_par_10 none Proportional portion of the cascade controller. in_par_11 none Tn control parameter of the cascade controller. in_par_12 none Tv control parameter of the cascade controller. in_par_13 none Adjusted maximum internal temperature of the cascade controller. in_par_14 none Adjusted minimum internal temperature of the cascade controller. in_par_15 none Band limit (upper) in_par_16 none Band limit (lower) in_mode_01 none Selected setpoint: 0 = SETP 1 1 = SETP 2 2 = SETP 3 3 = Last setpoint setting was carried out through an external programmer in_mode_04 none Internal/external temperature control: 0 = Temperature control with internal sensor. 1 = Temperature control with external Pt100 sensor. in_mode_05 none Circulator in Stop/Start condition: 0 = Stop 1 = Start in_mode_08 none Adjusted control dynamics 0 = aperiodic 1 = standard 11.4. Status messages Status messages Description 00 MANUAL STOP Circulator in OFF state. 01 MANUAL START Circulator in keypad control mode. 02 REMOTE STOP Circulator in r OFF state. 03 REMOTE START Circulator in remote control mode. 58

ME 11.5. Error messages Error messages Description -01 LOW LEVEL ALARM Low liquid level alarm. -02 REFRIGERATOR ALARM Control cable of the refrigerated circulator or MVS solenoid valve controller short-circuited or interrupted. -03 EXCESS TEMPERATURE WARNING -04 LOW TEMPERATURE WARNING High temperature warning. Low temperature warning. -05 WORKING SENSOR ALARM Working temperature sensor short-circuited or interrupted. -06 SENSOR DIFFERENCE ALARM Sensor difference alarm. Working temperature and safety sensors report a temperature difference of more than 25 C. -07 I 2 C-BUS ERROR Internal error when reading or writing the I 2 C bus. -08 INVALID COMMAND Invalid command. -09 COMMAND NOT ALLOWED IN CURRENT OPERATING MODE Invalid command in current operating mode. -10 VALUE TOO SMALL Entered value too small. -11 VALUE TOO LARGE Entered value too large. -12 TEMPERATURE MEASUREMENT ALARM -13 WARNING : VALUE EXCEEDS TEMPERATURE LIMITS -14 EXCESS TEMPERATURE PROTECTOR ALARM Error in A/D converter. Value lies outside the adjusted range for the high and low temperature warning limits. But value is stored. Excess temperature protector alarm -15 EXTERNAL SENSOR ALARM External control selected, but external Pt100 sensor not connected. -20 WARNING: CLEAN CONDENSOR OR CHECK COOLING WATER CIRCUIT OF REFRIGERATOR -21 WARNING: COMPRESSOR STAGE 1 DOES NOT WORK -22 WARNING: COMPRESSOR STAGE 2 DOES NOT WORK -23 WARNING: HIGH TEMPERATURE ON COMPRESSOR STAGE 1-24 WARNING: HIGH TEMPERATURE ON COMPRESSOR STAGE 2 Cooling of the condenser is affected. Clean air-cooled condenser. Check the flow rate and cooling water temperature on water-cooled condenser. Compressor stage 1 does not work. Compressor stage 2 does not work. Excess temperature on compressor stage 1. Excess temperature on compressor stage 2. 59

Remote control Error messages Description -25 REFRIGERATOR WARNING Error in the cooling machine. -30 CONFIGURATION ERROR: CONFIRM BY PRESSING <ENTER> ON CIRCULATOR The configuration of the circulator does not conform to its present use. Press enter to automatically perform a single modification of the configuration. -33 SAFETY SENSOR ALARM Excess temperature sensor short-circuited or interrupted. -40 NIVEAU LEVEL WARNUNG Low liquid level warning in the internal reservoir. 60

ME 12. JULABO Service Online remote diagnosis JULABO circulators of the HighTech series are equipped with a so-called black box. This box is implemented in the controller and records all significant data for the last 30 minutes. In case of a failure, this data can be read out from the unit by using special software. The respective program is available for free download from www.julabo.de \ EasyBlackBox. Installation is easy and carried out step by step. Please observe the instructions. Data read-out is possible in the conditions OFF, R OFF or ALARM. Connect the circulator to the computer using an interface cable. Start the EasyBlackBox program. The program asks for the used port (COM1,...) and the baud rate of the unit. You do not have this information on hand? Simply try it out! The program keeps on sending this request until the actually used port and correct baud rate are entered. Data is read out and shown on the monitor divided in the sections >Einstellungen/Settings<, >Alarmspeicher/Alarms stored<, >Blackbox< see example After pressing >Speichern/Save< a text file is compiled. The program proposes a filename - >C:\model description and barcode no.<. Modifications are possible. E-mail this file to service@julabo.de, JULABO's service department. JULABO is thus able to provide rapid support. 61