with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)
|
|
- Gertrude Summers
- 5 years ago
- Views:
Transcription
1 Examples of use Example Creating an SMS-based alarm with confirmation A project file must first be created using the A-Editor software. This project file is then stored in the alarm modem. The alarm modem is thus configured and functional. Measuring instrument: Contact Alarm goes to SMS Alarm: Alarm text Data logger 77 T (temperature) with internal sensor (channel ) with an external sensor (channel ) A-Editor software, Professional AK0 version (not for version AK) Technician 0-7 (mobile no. of technician) An alarm is to be sent when the external sensor reaches > C. Only the internal alarm from the logger is to be forwarded by the alarm modem, i.e. the logger is not to be permanently monitored by the alarm modem. Advantage: The logger battery is preserved. If the alarm is not confirmed within minutes, the same alarm is sent again. The technician confirms the alarm: he responds to the SMS received by sending the original text (containing the confirmation code) back to the alarm modem word for word. Alarm! Channel : "channel reading" > C. "Confirmation Code". "Date + Time" A) Requirements - The data logger must be programmed so that: - Alarm on logger is not set to on, i.e. red LED flashing - The upper alarm threshold of channel is set to C - All other alarm thresholds are well out of range - The required measuring cycle is set. - The A-Editor software is installed on the PC. B) Cabling The logger is linked to the alarm modem (COM) by means of the serial interface cable. For programming the alarm modem (COM), this is connected to the PC by means of the serial interface, but only while the project file is being created and saved. (See Chapter. Setting up alarm modem) C) Programming the alarm modem using the A-Editor: Start A-Editor software and access the project file containing the configuration of the alarm modem by doing one of the following: a) Load from the alarm modem; b) Load from PC; c) Create from new (refer to example in "Commissioning"). For this, the modules in the software must be processed as follows: Page
2 . Project module The project file contains all of the configuration data for operation and the requisite functions of the alarm modem. The options for creating the project file are as follows: - Use existing project file from the alarm modem as a template and modify accordingly: -> "Read Project" (see options bar on the left-hand side) For this, the alarm modem must be connected to the PC. Only then is the function shown. For activating the connection, refer to next chapter, "Connection module". - Use existing project file from the PC memory as a template and modify accordingly: -> "Load..." (options bar on left-hand side) I - Create a completely new project file: -> Select "New Project from Template" II Note: To set up a new project file, which requires considerably more information to be input than can be explained here, please refer to example in "Commissioning" or the Instruction manual. I II Page
3 . Connection module Create connection to alarm modem in A-Editor, i.e. select first, then connect: Imperative: The alarm modem must by this point be connected to the PC by means of the serial interface cable. In the first window, select "New" in the options bar on the left hand side, whereupon the new window will appear: 7 Connection Name Enter name for the connection. Location Enter location. No relevance to the messages. Type Select type of connection required. In the example, the project file is to be saved from the PC to the alarm modem, locally by means of a cable. Advanced Opens the details for "Local Modem". Find modems Click on here. The connected modem is identified, provided that the correct cabling is installed. Authentication A password can be stored in the project file as a means of access protection (in Alarm Modem Module). If a project file with this kind of access protection is used, e.g. is already saved in the alarm modem, the password must be given at this point to gain access to the alarm modem. This is not the password for remote switching which has to be given in the SMS text. Connect 7 Click on here and create the connection. Page
4 . Alarm Modem module The basic data about the SIM card and providers are stored here. If an existing project has been loaded, no changes are required at this point in order to carry out the "Alarm" function described in this example. The above data only have to be entered when creating a completely new project file. However, this is discussed in a separate section; please refer to the example given in one of the following: Commissioning or the Instruction manual. Page
5 . Variables module Variables Autodetect The A-Editor identifies all variables with the units which are available for the measuring instrument connected. Apart from this, the current values/readings are read in.the variables also include the readings for the individual channels, including the unit. In the example: ch# C (channel ) ch# C (channel ) Read Variables The values of the individual variables are read out of the alarm modem, i.e. they are not the measurement values from the measuring instrument itself, but the values which were read out from the measuring instrument into the alarm modem during the last Autodetect. For the purposes of further programming, it is advisable, or even necessary, that all variables available from the measuring instrument have been detected. To this end the variables must be scanned with "Autodetect"! This assumes that the instruments have been wired correctly and a connection has been activated in the "Connection" module. The command "Read Variables" will only provide correct values/units if the project has previously been sent to the alarm modem with the correctly scanned variables. How to send the project is described later under point 8. Page
6 . Address Book module 7 Address Book module In the first window: On the left-hand side in the Options menu: click on "New Contact". Name Name of contact Not necessary, as the alarm message should only be transmitted via SMS. Express To be left empty, function not activated SMS number Enter the mobile number of the contact address Pager number To be left empty, function not activated Fax Number Not necessary, as the alarm message should only be transmitted via SMS. OK 7 Finish and save the new contact. Page
7 . Messages module Messages module In the first window: On the left-hand side in the Options menu: Click on "New Message" or modify existing message by double-clicking on it. Name of Message Title for the message Message Type Choose appropriate message type, "SMS" in this case. Message Text Enter the message text: The variables - "ch# C" (current reading for channel ) A randomly generated code is sent to the recipient of the alarm in the alarm SMS. This code must be sent back to the alarm modem via SMS within the confirmation timeframe (definable), otherwise another alarm will be sent. - "Confirmation Code" - "Date + Time" are selected with the help of the Contact menu. Do this by rightclicking on the appropriate part of the text and selecting the relevant variable via the menu structure; in the case of the channel reading for example: -> testo 7/77 ->Inputs -> ch# C Append Location Text If the location text (as shown in the preview) is to be attached to the SMS, please activate the box. Remaining Characters Displays the remaining number of characters for the SMS. No further information can be sent by SMS. OK Finish and save the message. Page 7
8 7. Alarms module Example alarms have already been created in the list of alarms and are activated. Those alarms which you yourself are not using or modifying should be deactivated. Do this by going into each individual alarm and declicking the "Activated" box. As the internal alarm of the data logger is used as a trigger, the following must be observed: When programming the data logger, the following settings must be made in the ComSoft -> Instrument control -> Settings: Ativate Alarm Switch Output. Alarms module In the first window: On the left-hand side in the Options menu: Click on "New Alarm" or modify existing alarm by double-clicking on it. Name Name of alarm Event "Threshold Overshooting" must be selected in order to forward the internal alarm of the data logger. This option is recommended for data loggers, because the alarm modem does not wake the measuring instruments according to the rhythm of the querying rate, but only reacts to their alarm output. The querying rate can thus be h (factory setting). This considerably increases the battery life of Page 8
9 the data logger. However, when the internal alarm in the data logger switches to on, and the corresponding variable assumes the value accordingly, the querying rate automatically changes to 0 sec. The.original querying rate switches back to the original condition only when the alarm in the data logger is reset to 0 (via SMS switch command, with the Alarm Editor or by reprogramming the data logger). Variable The internal alarm of the data logger must be chosen here as the variable: "testo 7/77-Alarm" Trigger To access the alarm condition (data logger alarm from 0 to, corresponding to reading > C), "Low to High" must be chosen. Activated Activate alarm Contact Choose "Technician" and the message type: "SMS" Message 7 Select "Example Alarm" Following Alarm 8 Select "(Retry)". The same alarm text is thus sent again to the same destination. "Create New Alarm is also an option. The content and destination can both be reset in the new alarm. Confirmation 9 Activate Confirmation Timeframe 0 Set to " Minutes". OK Save alarm with "OK". Test Alarm In the options bar on the left-hand side of the screen. The alarm is triggered for testing using this switch. This checks that the alarm has been transmitted correctly, including with the requisite content. Testing the alarm this way is recommended before putting the system into service. Page 9
10 8. Project module Project module Save As... It is a good idea to save the project file to the PC under a name first before loading it into the alarm modem. Send Project Load the project file into the alarm modem. The alarm modem is now fully configured or programmed. The cabling between the alarm modem and PC can be disconnected and the system (consisting of the alarm modem and measuring instrument) can be left to operate. Exit the A-Editor. Page 0
Sentient. Downloader Manual D4854
Sentient Downloader Manual D4854 Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.com sales@dyconsecurity.com TABLE OF CONTENTS
More informationFCD-wire Contents. List of Figures
FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface
More informationAlarm handling by SMS in ALERT
Micromedia International Alarm handling by SMS Author: Jens Eberle Pages : 9 Company: Micromedia International Date : 29/10/2013 Version : 1.1 Réf. : Alarm Handling by SMS.docx [Commentaires ] Alarm handling
More informationOther trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.
Attention! Read this user manual carefully. Representative of the company installing the alarm system will explain which security module SP231 functions needs to be activated to ensure proper security
More informationInternet enabled RTU/Data loggers. ilog-gsm/edm: Tutorial Vers /2.0 August 2006
ilog s ilog-gsm/edm: Tutorial Vers. 1.2-3.4/2.0 August 2006 1. Introduction ilog is a new generation digital RTU/data logger incorporating full Internet capabilities. This step by step tutorial intends
More informationrvm4c Installation Guide Remote Video Module
rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation
More informationIRIS Touch Firmware Enhancements and Additions from Version to Version
Overview IRIS Touch Firmware Enhancements and Additions from Version 1.14.3 to Version 1.19.1 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.14.3 to Version
More informationWiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title
WiFi Hints & Tips Contents Page No. Section No. Title Section.0 System Set-Up 3 Section. Sensor Set-Up 4-5 Section. Sensor Set-Up (Configuring Network) 6-9 Section.3 Sensor Set-Up (Configuring Settings)
More informationSCAN200E USER S MANUAL
SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We
More informationCONTENT version Piccolo Object protection
CONTENT version 1.14 1: PICCOLO - WIRELESS PROTECTION... 4 HOW THE PICCOLO SYSTEM WORKS... 4 SYSTEM DESCRIPTION... 4 DETECTORS... 4 ALARM RECEIVERS... 4 CENTRAL UNIT & PC... 4 FORWARDING ALARMS (INTERFACES)...
More informationSC-F3G User Manual 1.0
SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...
More informationSCAN20 Series Gas Detection Controller
SCAN20 Series Gas Detection Controller USER S MANUAL Code Number 2071 1022 SCAN20 USER S MANUAL Code no. 2071 1022 Page 1/14 Foreword This manual is made for SCAN20 Controllers equipped with the software
More informationGLOBAL. InstallatIon & operation manual
InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...
More informationFire Control Panel FS5100
Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.
More information1. User features of the GSM dialer
1. User features of the GSM dialer The JA60GSM dialer offers many useful features described in detail below. The installer should properly demonstrate the use of the system to the user after installation
More informationInteractive Fire Control Panel IFS7002 four signal loops Instruction Manual
Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...
More informationD3D Wi-Fi GSM Smart Alarm System -User Manual
D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM
More informationION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document
70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,
More informationFire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63
Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.
More informationContents. Glossary
Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationSA 2650 Kit User Manual
SA 2650 Kit User Manual Table of Contents 1. System Installation Planning 1 2. Device Introduction 3 3. Getting Started 6 4. System Default Setting 10 5. Connect2Home Application 11 6. System Information
More informationDESCRIPTION OF KEYPAD (Access module with segments)
DESCRIPTION OF KEYPAD (Access module with segments) For the most convenient control and status indication the JABLOTRON 100 system offers various types of access modules. Controlling (setting, unsetting
More informationZITON RADIO LOOP MODULE
ZITON RADIO LOOP MODULE PROGRAMMING MANUAL Table of Contents Section Page No 1.0 INTRODUCTION...3 1.1 System Design...3 1.2 Handling Precautions...3 1.3 Packaging:...3 2.0 MENU STRUCTURE...4 2.1 Menu Structure
More informationOperations Manual TS400. Test Station for G450/G460 Gas Detector
TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations
More informationPageOne 2-way Pager Assured 2-way messaging for critical communications
Operating instructions PageOne 2-way Pager Assured 2-way messaging for critical communications www.pageonepager.com Contents Foreword......................................................... 3 Getting
More informationOperation Manual Fighter ProVision Software. Version: 0.0 Revision: 1
Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User
More informationOperation Manual For model CM706E
Operation Manual For model CM706E www.temperatureguard.com The CM706E is an environmental monitor with built in Ethernet and Cellular alarming and reporting capabilities. This unit can monitor up to ten
More information600 Range Dialer Installation Manual. Version 1.0
600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract
More informationSolarSET GSM SolarSET GSM with a Beacon
Labkotec Oy Myllyhaantie 6 FI-33960 Pirkkala FINLAND Tel. +358 29 006 260 Fax +358 29 006 1260 13.08.2009 Internet: www.labkotec.fi SolarSET GSM SolarSET GSM with a Beacon Solar Powered Oil Separator Alarm
More informationInteractive Fire Control Panel IFS7002 one signal loop Instruction Manual
Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...
More informationPBI Manual. Paradox to KNX-BUS Interface
PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...
More informationOperations Manual TS400. Test Station for G450/G460 Gas Detector
TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations
More informationINSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2
INSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2 Introduction Ariterm GSM-A2 is a compact universal alarm transmitter that transmits alarms and receives commands via SMS. The alarm and status changes
More informationNookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )
1 Installation Guide NookBox Keypad (P119010 / E6309744) 2 NookBox Keypad (P119010 / E6309744) 3 Parts Identification 1. Active LED 2. Status LED 3. Fault Display LED 4. Arm Key 5. Home Key 6. Key Check
More informationBURGLAR ALARM PANEL BS-468
BURGLAR ALARM PANEL BS-468 Contents 1. Description... 3 2. Instructions for the user... 4 2.1Basic operations... 4 Complete system.... 4 Split system.... 4 2.2 Armed system indication... 5 2.3 Advanced
More informationCRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment
Control Room Integrated Monitoring Environment INDEX 1. Requirements for software. 2. Installation Instructions. 3. How to Register your Software. 4. Start Using... 5. Operating Instructions. 6. Screen
More informationAdvisor Advanced Mobile Application User Manual
Advisor Advanced Mobile Application User Manual Content Warnings and Disclaimers 2 Advanced Mobile 2 Contact information 2 Description 2 Screen navigation 4 Gestures 4 Menu 4 Help navigation 4 Login 5
More informationPAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)
Instruction Manual PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet) TYPE: PHU INP-TN5A0024-E Note: MODBUS is the registered trade mark of AEG Schneider Aumaion International. NOTICE 1. Exemption items
More informationWatchguard WGAP864 User Manual
Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding
More informationMonitoring Solutions
GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5
More informationGSM RFID VOICE Alarm System
GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel
More informationRAy SNMP. Application notes.
Application notes. RAy SNMP. version 1.0 12/29/2017 RACOM s.r.o. Mirova1283 59231 Nove MestonaMorave CzechRepublic Tel.: +420565659 511 Fax: +420565659 512 E-mail: racom@racom.eu www.racom.eu Table of
More informationECO601 OPERATING INSTRUCTIONS ME04
RAK 72.2 9.11.2010 1 2 3 4 5 6 7 8 9 0 # ECO601 OPERATING INSTRUCTIONS ME04 PRESENTATION The ECO601 is intended for the simple control and surveillance of premises. This device can be controlled locally
More informationABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE
ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE isocket Smart Relay is a complex Smart House system which is installed in the fuse cabinet (electric cabinet) in the house. We therefore assume that
More informationLevelSET S GSM Functionalities Instructions for Commissioning and Use
Labkotec Oy Myllyhaantie 6 FI-33960 Pirkkala, Finland Tel: +358 29 006 260 Fax: +358 29 006 1260 22.10.2010 Internet: www.labkotec.fi LevelSET S GSM Functionalities Instructions for Commissioning and Use
More informationLaptop / PC Programming Manual
Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup
More informationAmbient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B
Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output Model LFS108B Copyright 2018 - LLC. All rights reserved. Table of Contents Quick Start... 3 1- Introduction... 4 2-
More informationMobeye CM2410 GSM fire alarm communicator
PORTAL USER MANUAL Mobeye CM2410 GSM fire alarm communicator Accessory for Ei Electronics fire detector SW version 5.n Incl. CM2400 Attention! Very important This user manual contains important guidelines
More informationSimplex Panel Interface Guide
Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.
More informationOctalarm-T: the latest in future-proof industrial alarm diallers
Octalarm-T: the latest in future-proof industrial alarm diallers Companies are becoming increasingly reliant on computers and technical equipment. Meaning you have to take steps to guarantee continuous
More informationIon Gateway Cellular Gateway and Wireless Sensors
Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the
More informationOntech GSM 9040/50. Reference Manual English -1 -
Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7
More informationSALES SUPPORT DOCUMENT
SALES SUPPORT DOCUMENT ML-1632 MAXLOGIC SUPERVISOR GRAPHIC MONITORING AND CONTROL SOFTWARE INTEGRATED WITH ENVIRONMENTAL SYSTEMS AND MANAGING ML-1632 supervisor software is a specially developed and easy
More informationTURN OFF ALARM AUTO ALARM RESET WRITE A COMMENT DISPLAY THE GUARDS GUARD FUNCTION RELAY INTERFACE:...
CONTENT version 2.03 1: PICCOLO - WIRELESS PROTECTION... 3 HOW THE PICCOLO SYSTEM WORKS... 3 SYSTEM DESCRIPTION... 3 DETECTORS... 3 ALARM RECEIVERS... 3 PICCOLO SERVER UNIT... 3 FORWARDING ALARMS (INTERFACES)...
More informationJA-63 Profi User manual
JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...
More informationEngine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list
OPERATOR'S MANUAL Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax:
More informationUser Manual & Setting Instructions
WT-9001 IP65 GSM Remote Controll And Allarm System User Manual & Setting Instructions WW II TT UU RR AA CC OO RR PPOO RR AA TT II OO NN SS DDNN BB HH DD WT-9001 IP65 GSM REMOTE CONTROL AND ALARM SYSTEM
More informationEZY SWITCH. SMS-IRR-4 System Monitor Installation Manual
EZY SWITCH SMS-IRR-4 System Monitor Installation Manual Table of Contents COMMANDS Getting Started Setting Up Initial User 7 Adding a User 8 Removing a User 8 Adding an Administrator 8 Removing the Administrator
More informationPERMACONN PM1030 Includes DI300. Installation Manual
PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides
More informationThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET
ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET Model: MM7100-2D Index Introduction 1 PC Setup 2-3 Bluetooth Setup 4-5 Discovery 6 USB Setup for USB instruments 7 Setting Instrument Parameters
More informationSecurity Escort Central Console Software SE2000 Series
Release Notes Security Escort Central Console Software SE2000 Series Table of Contents 1 Security Escort v2.18.1.0... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions...
More informationViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1
ViewMatrix Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels Version: 2.0 Revision: 0.1 CONTENTS 1. Introduction...3 2. Keyboard...5 2.1 POWER indication - Normal Operation...5
More informationHow to Configure the Alarm Action Outgoing Cell Call MultiLogger Application Note #14
5 Gould Road, PO Box 2155 New London, NH 03257 Voice: (603) 526-9088 info@canarysystems.com www.canarysystems.com Overview How to Configure the Alarm Action Outgoing Cell Call MultiLogger Application Note
More informationInvisiFence User Manual
InvisiFence User Manual Version 1.2 Date May 2016 Table of Contents 1. Introduction... 3 2. General... 3 3. System Components... 4 4. Hierarchy of system components... 6 5. Processing unit Connections...
More informationFIRE SMS K T P EVACUATION ALERT SYSTEM UK LLP. FIRE SMS is a fire alarm service for deaf and hard of hearing people.
K T P UK LLP FIRE SMS EVACUATION ALERT SYSTEM FIRE SMS is a fire alarm service for deaf and hard of hearing people. It helps service providers and employers comply with the Equality Act 2010 and manage
More informationPRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg
PRODUCT CATALOGUE Cape Town 18 Darter Road Blue Water Estate Kommetjie Luke Fowles - 076 161 8124 luke@providenttech.co.za Frank Fowles - 082 445 1541 frank@providenttech.co.za www.providenttech.co.za
More informationSensor Cloud User Manual
Sensor Cloud User Manual Table of Contents DEVICES TAB 4 1. DEVICE LIST 4 2. EXPAND ALL 4 3. EXPAND 4 4. STATUS 4 5. DEVICE 4 6. NAME 5 7. MONITORING INTERVAL 5 8. LAST ACTIVITY 5 9. VIEW 5 10. DELETE
More informationSummit 3208GLD USER MANUAL. Electronics Line
Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...
More informationPORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n
SW version 5.n PORTAL USER MANUAL Mobeye WaterGuard-FS Float sensor CM2300FS Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device
More informationTrident User s Manual
Labkotec Oy Myllyhaantie 6 33960 Pirkkala FINLAND Tel. +358 (0)29 006 260 18.05.2017 Fax +358 (0)29 006 1260 Internet: www.labkotec.fi 34 pages Trident Copyright 2017 Labkotec Oy 1/34 TABLE OF CONTENTS
More informationTS400. Operating Manual. Test Station for Microtector II Series (G450/G460)
Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /
More informationKaleidescape Programming Manual for Elan Home Systems
Kaleidescape Programming Manual for Elan Home Systems Rev.1, July 2008 Elan Templates v1.0 2007-2008 Kaleidescape, Inc. All rights reserved. Kaleidescape and the Kaleidescape logo are trademarks of Kaleidescape,
More informationVehicle Tank Protection TANKSAVE. Fuel anti-theft system. Deters Warns
Vehicle Tank Protection Fuel anti-theft system Deters Warns PRESENTATION This system is available in three versions : 1. Use of the gauge fuel vehicle -. Basic Version 2. Using a probe to put in the tank
More informationMG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide
MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed
More informationIRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0
IRIS Touch 400 & 600 Range Installation Manual Honeywell Galaxy Range Version 2.0 Table of Contents 1 System Overview... 4 2 IRIS Touch 440 & 640 PCB Layout... 5 3 Connection & Configuration for Honeywell
More informationPowerWizard. Level 1.0 & Level 2.0 Control Systems Training
PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts
More information3D_ISS. Integrated Software System. User Guide Manual
3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development
More informationM2M Services Ltd. RControl Alarm - Installer Manual V 1.0
M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 Content Content... 2 Wiring the power supply module... 3 Wiring a siren... 3 SMARTEnroll self-learning zones... 3 Wireless keyfobs... 3 Supported
More informationMETOS Compact SMS. The smooth change of a product. Gottfried Pessl
METOS Compact SMS The smooth change of a product Gottfried Pessl METOS Compact the Technical Specifications Single Board Climate Station 512 kb Flash Memory 8 bit Siemens µprocessor 12 Minute Measurement
More information3 User s settings. 3.3 Internal clock setting
2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will
More informationHikCentral Web Client. User Manual
HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.
More informationFire Control Panel FS4000
Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds
More informationT M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power
T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200
More information3i SECURITY with i-mode Welcome to the future of security. Today with your i-mode telephone you have full control of your home and automobile even when you are not present. You may see directly on your
More informationM3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO
User s Manual Copyright 2017 SELCO SELCO Betonvej 11 - DK-4000 Roskilde Denmark Phone: 45 7026 1122 - Fax: 45 7026 2522 e-mail: selco@selco.com www.selco.com Table of contents 1 INTRODUCTION...4 2 SOFTWARE
More informationGSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.
Version: MS1 GSM Emergency Alarm User s Manual For a better understanding of this porduct,please read this user manual thoroughly before using it. CONTENTS CONTENTS Ⅰ. Introduction Ⅱ. Product Appearance
More informationDX2002 OPERATING AND PROGRAMMING INSTRUCTIONS
DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS The four pushbuttons located at the bottom right of the circuit board are used to do all programming. Each button has more than one function. Alternate Settings
More informationControl panel «Contact GSM-5-2»
Control panel «Contact GSM-5-2» Operating Manual Rev. 1.1 Saint Petersburg, 2017 Table of Contents Introduction 4 Panel Overview 5 Designation 5 Capabilities 6 Specifications 9 Design 11 Delivery Package
More informationPlease use authentic SATA hard drive, USB device and battery.
Note The device should be set in the room with good ventilation, far from water, hot reservoir or dust. Network Video Recorder is not designed to be used outdoor. Please use authentic SATA hard drive,
More informationUser manual. KNXgal. version
User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with
More informationAdded password for IP setup page : Password must be in IP format!
NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP
More informationTechnical Specification. For. Arla Tankvagt
Technical Specification For Arla Tankvagt Tankvagt - technical specifications ver. 4.2 CONTENT 1 DOCUMENT CONTROL...2 1.1 Revision History...2 1.2 Reviewers...2 1.3 Related Documents...2 2 INTRODUCTION...3
More informationLone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L
Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES www.duressandsafety.com.au Creating safer environments for people Increasingly organisations recognise the need
More informationHikCentral Web Client. User Manual
HikCentral Web Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright protection.
More informationEURO 46 V10 User Manual
EURO 46 V10 User Manual PD6662:2010+IA501:2015 EN50131-1:2008+A1:2009 EN50131-3:2009 Security Grade (SG) 3 - Large Security Grade (SG) 2 - Small Environmental Class (EC) II Software Version >10 RINS1943-1
More informationRESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)
FAAST LT FIRE ALARM ASPIRATION SENSING TECHNOLOGY ADVANCED SET-UP AND CONTROL GUIDE CONTENTS Introduction....1 The FAAST LT Functional State Diagram....1 Password Procedure (to enter Maintenance Mode)
More informationAGRI-ALERT 9600 ALARM SYSTEM USER MANUAL
AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void
More informationQuick Reference Guide
infinite Prime with Hybrid Connections User Manual - Version 1.00 Catalog Number: ZI0473A (1/07) All data is subject to change without prior notice. Hereby, Electronics Line 3000 Ltd. declares that this
More informationCBI-064. User Manual. Caddx to KNX-BUS Interface
CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...
More information