PureLine D. Technical Specification

Similar documents
Water temperature LBX 3 LBX 33: recommended range 5-25 C (41 77 F) LBX 90e LBX 1500e: recommended range 5-45 C ( F)

uv and ozone for commercial pools

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

WEDECO Quadron UV System

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

PRINCIPLE MAIN APPLICATION

TROJANUVSWIFT SC. Drinking Water Treatment

VS LD series vertical steam sterilizers

Section 3: Ultraviolet - UV

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Table of contents: Chapter V. V. Disinfection systems DOSADes

Operating Manual UV Monitor UVT 18

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

Flow Measurement SITRANS F C

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

254 Nanometer Germicidal UV Disinfection Systems

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN ZVSHK 1) DVGW 2) for Professionals

Level Measurement Continuous level measurement Ultrasonic transmitters

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Product Data Sheet Adsorption Dryer DPS (A)

CLARITY II TURBIDIMETER

Installation, operating and servicing instructions

ZED UV Monitor PRO11DPI-I

Rosemount 3100 Series Ultrasonic Level Transmitters

RELIANCE 680PG PHARMACEUTICAL GRADE WASHER

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

for Drinking Water Systems

A WORLD FIRST EN ZVSHK 1) Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push.

A measured step forward

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

ASME Packaged Electric Water Heater

Technical Information OUSTF10

UV Flame Supervision System

Pressurisation units & expansion vessels

88MLV Series Open Channel Modular UV Systems

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Customer Manual. MADE IN USA Effective

Product Data Sheet Adsorption Dryer DPS

Sieger Apex. Flexibility that meets your requirements

Continuous level measurement Ultrasonic transmitters

ULTRA-VIOLET STERILIZATION

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Variable Frequency Drive SERIES MP800 VFD

Gerber Centrifuge Micro II. Instruction Manual (e)

HF Series R_RevB

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Options for Diesel Fire Pump Controllers

Getinge 8666/8668 Washer Disinfectors

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Low Temperature Zirconia Oxygen Analyzer

Rosemount 3100 Series Ultrasonic Level Transmitters

Vacuum drying oven for non-flammable solvents

Class 1 laser beam sensor safe for your eyes

FIL-SPL Flow-through heater for central heating USER MANUAL

Across-the-Line SERIES MP300 Combined Manual and Automatic

EcoPure TM HYGIENIC MAGDRIVE CENTRIFUGAL PUMP

Ventilation Trainer B500

Self Regulating Trace Heating Systems Installation and Maintenance. Non-Hazardous Area Installations

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

Customized Drinking Water

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Electronic timeswitch

CRU-S Series Stainless Steel Condensate Recovery Unit

Centro-Matic Automated Lubrication Systems System Controls

Safety vacuum drying oven for flammable solvents

WASTEWATER Online UV%Transmission Analyzer

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Instructions for the fan motor control system, SILVER C

IBC Wash: Critical Cleaning Solution for IBCs, Totes and Tablet Bins.

Rosemount 2090F Hygienic Pressure Transmitter

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Refrigerant air dryers. FD series ( l/s, cfm)

CRYOGENIC PRODUCTS SEB Series Trim Heater

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Silverware Pre-washing System INSTALLATION

MBCE-110/230UV Flame Sensor Module

PHARMACEUTICAL INDUSTRY CLEANING SYSTEMS

RAYCHEM NGC-30 COMPONENTS

GRU-V Air Purifier. Product Manual

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

Class 1 laser beam sensor safe for your eyes

A Chiller is equipment to control temperature of customers heating sources. Application Examples

Soft Start Series MP700 Solid State, Reduced Voltage

Industrial, Medical and cgmp-conform Cleaning Equipment

Transcription:

... Complete Range Model Maximum Disinfection Maximum Disinfection Min. Flange Approx Weight (kg) Capacity * (m 3 /hr) Capacity ** (m 3 /hr) T 10 Size Chamber Power Power 26mJ/cm 2 RED 120mJ/cm 2 RED (%) DN (Empty) Supply (W) 0007 7.3 1.3 70 40 9 18 80 0013 12 2.4 70 50 9 18 140 0023 23 4.6 70 50 9 18 270 0047 46 9 70 80 25 18 270 0089 89 15 70 150 46 22 550 0083 84 8.9 78 100 50 85 2500 0105 109 16 95 150 65 85 2500 0209 217 28 90 150 65 85 3500 0300 322 50 93 200 140 165 5500 0530 550 91 90 250 140 165 7000 0680 825 170 62 300 150 290 14000 0850 1000 153 76 350 210 290 14000 95% and a hydraulic velocity of 3m/s ** The maximum disinfection capacity is based on a dose of 120mJ/cm 2 RED MS2 phage T 10 95%

0007 - D 0089 0083 - D 0850 UV Chamber UV Chamber Material: StSt 316L / 1.4404 Material: Polyester coated carbon steel Material: StSt 316L / 1.4404 Material: Polyester coated carbon steel Internal finish: External finish: As made pipe and tube, welds left as laid Sateen polish (120 grit) electropolished and passivated Degree of protection: IP65 / NEMA 4 except D 0089 which is IP55 / NEMA 12 Supply voltages: 230V (207V to 253V) or 115V (104V to 126V except D 0089) 50/60Hz Internal finish: External finish: As made pipe and tube, welds left as laid Sateen polish (120 grit) electropolished and passivated Degree of protection: IP54 equivalent to NEMA 12 Supply voltages: Up to 2.5kW 95 to 260V (nominal) 50/60Hz 3.5 to 7.0kW 190V to 500V (nominal) 50/60Hz >7.0kW 300V to 500V (nominal) 50/60Hz Process (mating) connections: Flange DN series PN16 rated Operating temperature range: Process (mating) connections: Flange DN series PN16 rated Operating temperature range: Drain connection: BSPT Relative humidity: <90% Drain connection: BSPT Relative humidity: <90% End plate: Removable tri-clamp except D 0089 which is a bolted plate Degree of protection: IP65 equivalent to NEMA 4 but not suitable for outside use Arc tube (lamp): Arc tube enclosure: Number of lamps: 1 Expected lamp life: Temperature sensor: Low pressure amalgam / high purity quartz High purity quartz 12000-16000 hours On D 0089 only UV monitor: Wet UV monitor (down to minimum T 10 ) Working fluid temperature: Maximum CIP temperature: Hydrostatically pressure tested: Operating / Design pressure: Pressure Loss: Seals: 95 C with control cabinet electrically isolated Yes to PED requirements EN13445 6 bar / 7 bar Typically < 45 mbar including wiper EPDM FDA approved Cooling fans: On D 0089 cable length: External contacts: 5m 4-20mA signal for UV intensity %, Volt Free Contacts for Lamp On, Low UV warning End plate: Removable bolted plates Degree of protection: IP65 equivalent to NEMA 4 but not suitable for outside use Arc tube (lamp): Arc tube enclosure: Number of lamps: 1 to 4 Expected lamp life: Temperature sensor: Medium pressure / high purity quartz High purity quartz 4000-8000 hours Yes UV monitor: Wet UV monitor (down to minimum T 10 ) Working fluid temperature: Maximum CIP temperature: Hydrostatically pressure tested: Operating / Design pressure: Pressure Loss: Seals: +5 C to +60 C 95 C with control cabinet electrically isolated Yes to PED requirements EN13445 6 bar / 7 bar Typically < 150 mbar EPDM FDA approved Cooling fans: cable length: External contacts: Yes 10m 4-20mA signal for UV intensity, Volt Free Contacts for Local/Remote, System Available, Lamp Ready, System Warning, Common Alarm, Low UV Intensity, ELCB Trip

...... Product Specific Data 0007 - D 0089 Features Dimensions (mm) Operational Features: Screen Display Features: Alarm Message Features: Safety Features: Chamber: A D Lamp on/off Remote start/stop Alarm rest button Low UV warning Horizontal mounting for all or vertical mount except for D 0089 2 line x 16 character backlit LCD with indication of System Status Remote mode UV intensity% Warning and trip messages Total hours run Lamp fail Low UV % intensity Unit tripped Door interlocked cabinet isolator Separate door lock Resettable circuit breaker Power on LED DN C B Chamber English language E Chamber Mounting 400-600 CRS Options Approvals : K L Validation Support Pack Stainless Steel cabinet (304) CE following the low voltage and EMC directives conforming to EN61000-3-2, 3-3, 6-2 and 6-4 230V version only Printed operating, menu and safety guides in Chinese, French and German Uvtronic control 230V (207 to 263V) CE and UL approved with pre-calibrated DVGW compliant dry UV monitor M Tri-clamp connections to BS 4825 with tri-clamp drain internal finish <0.38µm Ra maximum welds as laid Auto-wiper with status LED s pneumatic operation ANSI 150 flanges and NPT drain CIP maximum 130 C with cabinet electrically isolated Additional Information All dimensions are approximate for clearance purposes only. Hanovia has a policy of continuous product development, exact drawings are available on request. All specifications are subject to change without notification. Your Distributor or Hanovia Account Manager can advise on correct dosage and specific requirements. Certificate No: FM29365 Model Maximum Min. Dimensions (mm) Approx Weight (kg) Disinfection T 10 unwiped dimensions 230V unwiped 230V wiped or 110V Chamber Power Power Capacity* (m 3 /hr) (%) A B C D E DN K** L** M** K** L** M** (Empty) Supply (W) 0007 7.3 70 1385 1273 150 1300 102 40 225 300 550 275 400 750 9 18 80 0013 12.7 70 1385 1273 150 1300 102 50 225 300 550 275 400 750 9 18 140 0023 23 70 1385 1273 150 1300 102 50 225 300 550 275 400 750 9 18 270 0047 46.8 70 1437 1300 200 1300 168 80 225 300 550 275 400 750 25 18 270 0089 89 70 1985 1825 250 1900 206 150 225 700 750 275 700 750 46 22 550 95% and a hydraulic velocity limit of 3m/s ** dimensions allow for door isolator, cable entry, bracket space and fan space on D 0089

... 0083 - D 0850 Product Specific Data Features Dimensions (mm) Operational Features: Screen Display Features: Alarm Message Features: Safety Features: Chamber: Service Access A (with wiper) Lamp Change Access Lamp on/off Remote start/stop Selectable auto restart following power failure Event log Horizontal mounting only 2 line x 20 character VFD with indication of System Status Remote mode UV intensity in mw/cm 2 or relative intensity (%) Warning and trip messages Total hours run Spares listing English language Lamp fail Low UV % intensity ELCB tripped Wiper trip Power failure Chamber over temperature Power supply over temperature warning and trip Door interlocked cabinet isolator Separate door locks Power supply thermal cut out Resettable circuit breaker Earth leakage trip Wiper motor overload cut out : D K DN L C 300 B Chamber 1500 (max) Options Approvals Validation Support Pack Stainless Steel cabinet (316) Printed operating, menu and safety guides in Chineses, French and German Tri-clamp connections to BS 4825 with tri-clamp drain Chamber internal finish <0.38µm Ra maximum welds ground out Auto-wiper with status messages electrical operation ANSI 150 flanges and NPT drain Lead length 30m or 50m CIP maximum 130 C with cabinet electrically isolated CE following the low voltage and EMC directives conforming to EN50081-1, EN61000-4-2, 4-3, 4-5, 4-6, 4-8 and 4-11 UL listed E149108 M Model Maximum Min. Dimensions (mm) Approx Weight (kg) Disinfection T 10 A B C D DN K** L** M** Chamber Power Power Capacity * (m 3 /hr) (%) (Empty) Supply (W) Additional Information All dimensions are approximate for clearance purposes only. Hanovia has a policy of continuous product development, exact drawings are available on request. All specifications are subject to change without notification. Your Distributor or Hanovia Account Manager can advise on correct dosage and specific requirements.... Certificate No: FM29365 0083 84 78 1300 710 319 240 100 370 750 850 50 85 2500 0105 109 95 1300 660 420 290 150 370 750 850 65 85 2500 0209 217 90 1300 660 420 290 150 370 750 850 65 85 3500 0300 322 93 1300 610 505 410 200 370 900 1100 140 165 5500 0530 550 90 1300 550 505 410 250 370 900 1100 140 165 7000 0680 825 62 1800 960 505 410 300 380 1100 1590 150 290 14000 0850 1000 76 1800 930 540 430 350 380 1100 1590 210 290 14000 95% and a hydraulic velocity limit of 3m/s ** dimensions allow for door isolator, cable entry and bracket space

...... Eight decades of continuous development has put Hanovia at the forefront of UV science and technology. Working with the biggest names in food, beverage, electronics, pharmaceutical, aquaculture, pools and leisure, and many other industries, we have gained valuable insights into our customers requirements and this enables us to offer you not only the finest UV systems, but a full UV solution for your industrial or leisure water treatment problems all backed by first class technical and service support, available wherever you are around the World. BREWING FOOD+DAIRY BOTTLED WATER+SOFT DRINKS t: +44 (0) 1753 515 300 f: +44 (0) 1753 515301 e: sales@hanovia.com Hanovia Ltd, 780 Buckingham Avenue, Slough, Berkshire, SL1 4LA UK SCAN TO KEEP INFORMED Visit our website for further information at www.hanovia.com 910333-2001-01 2012 Hanovia Limited / brochure design by Breathe Marketing Limited www.breathe4u.com