HUM-M2 Humidity Sensor Module Description

Similar documents
humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

89BSD Digital Output

HM-4201-RTCM High-Temp Real Time Clock Module

WIO200 Water In Oil measuring instrument

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

RS485 MODBUS Module 8AI

86BSD Digital Output

ECO N DATE DESCRIPTION OF CHANGE CHG

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Analog Input Module IC670ALG630

MEAS PICTAIL PLUS FOR MICROCHIP EXPLORER 16

86BSD Digital Output

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

HM-4201-RTCM High-Temp Real Time Clock Module

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Datasheet: K-22 LO Sensor

Relative Humidity Transmitters

Potential Applications

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

86BSD Digital Output

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Laser Particle Sensor Module PM2008M

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

FIS SMART SENSOR U (Draft 1) June 25, 2001

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

HYGROMER - MP 400 A Meteorology probe

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Model gffoz Process Ozone Sensor (In-Line)

HYGROMER MP 100 A Meteorology probe

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Toroidal Conductivity Transmitters Series APT4000 Specifications

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Duct Humidity/Temp Sensor

I/A Series 716C 1/16 DIN Temperature Controller

DP86 Constant Voltage with Fitting

FIS30XXseries Gas sensor module SPECIFICATIONS

HM1520LF Relative Humidity Module

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

Laser Particle Sensor Module PM2008M

Selecting the right humidity sensor for your application

FlameGard 5 MSIR HART

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

HIH-5030/5031 Series Low Voltage Humidity Sensors

Room Humidity/Temp Sensor

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

HSD Dry Cabinet. Outstanding performance

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

DOCUMENTATION IPS640

DOCUMENTATION IPS640

Danfoss gas detection units

Sensors in Ventilators

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Long Term Storage Cabinet

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

Automatic Isokinetic Sampler ST5

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

Outside Air Humidity & Temperature Sensor

SD Storage Cabinet. Outstanding performance

MEAS CAL ALARM WASH CONF APT4000 TC

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

RS Pro Infrared Temperature Sensor

Issue C CAUTION

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

HM1500LF Relative Humidity Module

Standard SPECIFICATIONS FEATURES APPLICATIONS

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Constant climate chambers

Honeywell Zephyr TM Digital Airflow Sensors: HAF Series High Accuracy 10 SLPM, 15 SLPM, 20 SLPM, 50 SLPM, 100 SLPM, 200 SLPM or 300 SLPM.

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

General Specifications

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

The supplier and installer of the system should be approved by the local civil defence authority.

Transcription:

HUM-M2 Humidity Sensor Module Description Humidity Sensor Modules are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for indoor air temperature and humidity monitoring in various industrial plant, clean room, lab, machine room, offi ce and commercial building, airport, station, library and stadium. Features: I²C Interface Precisely calibrated Low Hysteresis, compensated Linearity error and Temperature drift Plug-in type, RM 2.0 mm Miniature construction, fully interchangeable Optimum price performance ratio RoHS conformance Dimension Humidity Sensor Module HM-M2 Typical Areas of Applicatins: Handheld measurement instruments Humidity transmitters Industrial applications Measuring & Sensor Technology This digital humidity sensor with only 20 x 6 x 2.5 mm size offers the widest application window and an optimal price performance ratio. Precisely calibrated, the humidity sensor module delivers an accuracy of < 5% RH (@ 25 deg C and 50% RH, after nine point calibration), ideal for sophisticated large volume applications, industrial handheld devices and precise humidity transmitters. The sensor combines the advantages of a precise, capacitive polymer humidity sensor with the high integration density and functionality of an ASIC. The signal processing integrated in the sensor completely processes the measured data and directly delivers the physical parameters of relative humidity and temperature over the I²C interface. The humidity sensor has a feature which protects against condensation during prolonged periods of high humidity, over 95%, for more than one hour. When this condition is met the sensor will go to heating mode every 20 minutes, adjustable by the user. During heating, the sensor temperature will rise by 5 DegC over the ambient temperature. During this time the temperautre reading from before heating started will be assumed until the temperature falls back to normal or fi ve minutes time, whichever comes fi rst.

HUM-M2 Humidity Sensor Module Specifications Humidity Measurement Humidity Measuring 0 to 100% RH (max. DP = 80 deg Range C) Humidity Accuracy < 5% RH (@ 25 deg C and 50% RH, after nine point calibration) Hysteresis < 1.5% RH Loss Factor < 0.01 Recovery Time < 6 s (50% 0% RH; Vair = 2 m/s; response time < 3 s typ.) Temperature Measurement Sensor Type 10K SMD NTC thermistor Accuracy < ±0.5 C @ 25 C Communicatin Protocol 1) Pin Description PIN1 CLK PIN2 NC PIN3 RST PIN4 GND PIN5 +5V PIN6 DAT General Operating voltage Current consumption (Nominal) Application temperature Humidity application range Storage temperature 3 to 5.5V DC normal state: 3mA; heating state: 100mA -40 C to 85 C 0 to 100% rh -50 C to 150 C 2) Command read operation use 16 bits data, write operation use 8 bits data a) read humidity value & temperature value & heating state: send command 0xC1(8 bits) read data1 (16 bits), spare for user or factory test read data2 (16 bits), humidity value, for example, if current humidity is 45.0%, then data will be 450 read data3 (16 bits), temperature value, for example, if current temperature is 25.2 C/77.4 C, then data will be 252/774 read data4 (16 bits), heating state, if sensor is on heating processing, return 1, if not return 0 read data5 (16 bits), checksum, should equal to data1+data2+data3+data4

b) read sensor software version: send command 0xC2(8 bits) read data1 (16 bits), will return software version read data 5 (16 bits), checksum, should equal to 0x69 HUM-M2 Humidity Sensor Module c) write start heating command: send command 0xD5(8 bits) read data 5 (16 bits), checksum, should equal to 0xD5 d) write stop heating command: send command 0xD6(8 bits) read data 5 (16 bits), checksum, should equal to 0xD6 e) write temperature calibration command: send command 0xE5(8 bits) send data1 (8 bits), high byte of the temperature calibration value send data2 (8 bits), low byte of the temperature calibration value read data (16 bits), checksum, should equal to data1 + data2 f) write humidity calibration command: send command 0xE6(8 bits) send data1 (8 bits), high byte of the humidity calibration value send data2 (8 bits), low byte of the humidity calibration value read data (16 bits), checksum, should equal to data1 + data2 g) write change degree unit command: send command 0xE7(8 bits) send data1 (8 bits), 1 means degree F and 0 means degree C

3) I2C Timing Start Condition HUM-M2 Humidity Sensor Module Stop Condition One bit W/R timing

Accessories Description There will be a few accessories as well such as extension pipe, stainless steel sintered fi lter, pluggable connector, high temperature silicon cable, etc. HM-P-C Here following one picture to show HM-P-C-2m use. HUM-C