FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)
|
|
- Giles Strickland
- 6 years ago
- Views:
Transcription
1 FEATURES Dual Wavelength Bi-Directional Tx/Rx 1.25Gbps/1310nm Burst Mode Transmitter 1.25Gbps/1490nm CW Mode Receiver IEEE 802.3ah Compliant Single 3.3 Voltage Supply 2X10 SFF Package Outline Single Fiber Duplex Operation APPLICATIONS Gigabit Ethernet Access Networks Fiber to the Home, Curb, Office(FTTX) Point to Multi Point Service(P2MP) Up to 10km Reach (16:1 Split) Up to 20km Reach (8:1 Split) Absolute Maximum Ratings Parameter Symbol Min. Max. Units Note Storage Temperature Ts Power Supply Voltage Vcc 0 4 V Soldering Temperature seconds on leads only Recommended Operating Conditions Parameter Symbol Min. Typ. Max. Units Power Supply Voltage Vcc V Operating Temperature Top 0 70 Data Rate 1250 Mbps Power Supply Current Icc ma - 1 -
2 Transmitter Specifications (0 o C < Top < 70 o C, 3.13V < Vcc < 3.47V) Parameter Symbol Min. Typ. Max. Units Optical Optical Transmit Power Pout 0 4 dbm Electrical Background Light BDL -45 dbm Optical Center Wavelength nm Output Spectrum Width ΔλRMS Meets for IEEE 802.3ah PX10-U transmitter spectral limits (Maximum allowed RMS spectral width) Extinction Ratio E R db Optical Rise/Fall Time t r / t f 0.26 ns Optical Isolation 30 db Optical Return Loss 12 db Relative Intensity Noise RIN -115 db/hz Total Jitter TJ ns Data Input Current Low -350 ma Data Input Current High 350 ma Differential Input Voltage V IH -V IL mv Data Input Voltage Low V IL - V CC V Data Input Voltage -- High V IH - V CC V DC-Bias Disable Input Voltage -- Low V TDIS,L V - 2 -
3 DC-Bias Enable Input Voltage -- High V TDIS,H V TX DC-Bias Shut-off time t dc,off 20 ns TX DC-Bias Shut-on time t dc,on 20 ns TX Shut down time T sdwn 30 s Receiver Specifications (0 o C < Top < 70 o C, 3.13 V < Vcc < 3.47V) Parameter Symbol Min. Typ. Max. Units Optical Sensitivity Sen -27 dbm Maximum Input Power(Saturation) P MAX -3 dbm Signal Detect -- Asserted P a -26 dbm Signal Detect -- Deasserted P d -42 dbm Signal Detect -- Hysteresis P hys 1.0 db Wavelength of Operation λ nm Electrical Data Output Voltage Low V IL V CC V Data Output Voltage High V IH V CC V Signal Detect Output Voltage-- Low V SIL 0.8 V Signal Detect Output Voltage-- High V SIL 2.0 V - 3 -
4 Digital Diagnostic Memory map EEPROM Serial ID Memory Contents Accessing Serial ID Memory uses the 2 wire address X (A0). Memory Contents of Serial ID are shown in the Table 1. Table 1: Serial ID Memory Contents Data Size Address (Bytes) Name of Field Contents(Hex) Description BASE ID FIELDS 0 1 Identifier 02 Module/connector soldered to motherboard 1 1 Ext.Identifier 04 SFF 2 1 Connector 01 SC Connector Transceiver Encoding 01 8B10B 1000BASE-PX20-4 -
5 12 1 BR,Nominal 0D 1.25Gbit/sec 13 1 Reserved Length(9um)km Length(9um) C Length(50um) 00 Transceiver transmit distance: 20Km 17 1 Length(62.5um) Length(Copper) 00 Not compliant 19 1 Reserved Vendor name 42 4F 54 4F 4E BOTONE (ASCII) Reserved Vendor OUI Vendor PN Transceiver part number Vendor rev Wavelength 05 1E Transceiver wavelength :1310nm 62 1 Reserved CC_BASE Check Sum (Variable) Check code for Base ID Fields EXTENDED ID FIELDS Options 00 0C TX_FAULT and RX_SD is implemented BR,max 0A 10% 67 1 BR,min 0A 10% Vendor SN Serial Number of transceiver (ASCII). For example Date code Manufactory date code. For example Digital diagnostic monitoring implemented, Diagnostic 68 internal calibrated is implemented, RX Monitoring Type measurement type is Average Power Optional Alarm/Warning flags implemented for all Enhanced C0 monitored quantities, Optional Soft TX_Disable Options monitoring implemented, 94 1 SFF_ Includes functionality described in Rev
6 Compliance SFF CC_EXT Check Sum (Variable) Check sum for Extended ID Field. VENDOR SPECIFIC ID FIELDS Vendor Specific Read only Depends on customer information Reserved Read only Filled by zero Diagnostic Monitor Functions Diagnostic Monitor Functions interface uses the 2 wire address X (A2). Memory contents of Diagnostic Monitor Functions are shown in Table 2 Table 2: Memory contents of Diagnostic Monitor Function Data Address Field Size (bytes) Name Contents and Description Alarm and Warning Thresholds Temperature High Alarm Set to Temperature Low Alarm Set to Temperature High Warning Set to Temperature Low Warning Set to Vcc High Alarm Set to 3.6 V Vcc Low Alarm Set to 3.0 V Vcc High Warning Set to 3.5 V Vcc Low Warning Set to 3.1 V Bias High Alarm 70mA Bias Low Alarm 2mA Bias High Warning 60mA Bias Low Warning 4mA TX Power High Alarm 6dBm TX Power Low Alarm -2dBm TX Power High Warning 4dBm TX Power Low Warning 0dBm RX Power High Alarm 0dBm RX Power Low Alarm -30dBm RX Power High Warning -3dBm RX Power Low Warning -27dBm - 6 -
7 Reserved Calibration Constants RX Power Calibration Data (fixed) RX Power Calibration Data (fixed) RX Power Calibration Data (fixed) RX Power Calibration Data1 3F (fixed) RX Power Calibration Data (fixed) Bias Calibration Data (fixed) Bias Calibration Data (fixed) TX Power Calibration Data (fixed) TX Power Calibration Data (fixed) Temperature Calibration Data (fixed) Temperature Calibration Data (fixed) Vcc Calibration Data (fixed) Vcc Calibration Data (fixed) Reserved (fixed) 95 1 Check Sum Checksum of bytes 0-94 Real Time Diagnostic Monitor Interface Measured Temperature Yield to a 16-bit A/D value (see Table 2.1) Measured Vcc Yield a 16-bit A/D value (see Table 2.1) Measured Bias Yield a 16-bit A/D value (see Table 2.1) Measured TX Power Yield a 16-bit A/D value (see Table 2.1) Measured RX Power Yield a 16-bit A/D value (see Table 2.1) Reserved Logic Status See Table AD Conversion Updates See Table Alarm and Warning Flags See Table 2.3 Vendor Specific Vendor Specific Don t Access User writable EEPROM Vendor Specific Don t Access The measured values located at bytes (in the 2 wire address 0xA2) are raw A/D values (16-bit integers) of transceiver temperature, supply voltage, laser bias current, laser optical output power and received power. All the measured values are Externally Calibrated, and then it is necessary to convert raw A/D values to real world units by the manner as shown in Table
8 Table 2.1: Real Time Diagnostic Monitor Values Byte Name Description 96 Temperature MSB Internally measured transceiver temperature. Comply with 97 Temperature LSB External Calibration of SFF Vcc MSB Internally measured supply voltage. Comply with External 99 VCC LSB Calibration of SFF Laser Bias MSB Measured Laser bias current. Comply with External Calibration of 101 Laser Bias MSB SFF Tx Power MSB Measured Tx power. Comply with External Calibration of 103 TX Power LSB SFF Rx Power MSB Measured Tx power. Comply with External Calibration of 105 RX Power LSB SFF This transceiver implements two optional status bytes, Logic States at byte 110(0xA2) and A/D Updated at byte 111(0xA2) as shown in Table 3.2. A/D Updated status bits allow the user to verify if an update from the analog-digital conversion has occurred of the measured values, temperature, Vcc, laser bias, Tx power and Rx power. The user writes the byte to 0x00. Once a conversion is completed for a given value, its bit will change to 1. Table 2.2: Logic Status and AD Conversion Updates Byte Bit Name Description Tx Disable State Not supported (set to 0) Soft Tx Disable Control 1=Disable, 0=Enable Reserved Set to Rx Rate Select State Not supported (set to 1) Soft Rate Select Control Not supported (set to 0) Tx Fault Not supported (set to 0) LOS Not supported (set to 0) Power on Logic Bit will be 0 when the analog monitoring is active ~0 Temp A/D Valid Set to 0 Each of the measured values has a corresponding high alarm, low alarm, high warning and low warning - 8 -
9 threshold level at location 00-39(x0A2) written as the data format of a corresponding valued shown in Table 2.3.Alarm and warning flags at bytes (0xA2) are defined as follows. [1] Alarm flags indicate conditions likely to result (or have resulted) in link failure and cause for immediate action. [2] Warning flags indicate conditions outside the guaranteed operating specification of transceiver but not necessarily causes of immediate link failures. Table 2.3:Alarm and Warning Flags Byte Bit(s) Name Description Temperature High Alarm Set when temperature monitor value exceeds high alarm level Temperature Low Alarm Set when temperature monitor value exceeds low alarm level Vcc High Alarm Set when Vcc monitor value exceeds high alarm level Vcc Low Alarm Set when Vcc monitor value exceeds Low alarm level Laser Bias High Alarm Set when laser bias monitor value exceeds high alarm level Laser Bias Low Alarm Set when laser bias monitor value exceeds low alarm level Tx Power High Alarm Set when Tx power monitor value exceeds high alarm level Tx Power Low Alarm Set when Tx power monitor value exceeds low alarm level Rx Power High Alarm Set when Rx power monitor value exceeds high alarm level Rx Power Low Alarm Set when Rx power monitor value exceeds low alarm level Reserved All bits set to Reserved All bits set to Reserved All bits set to Temperature High Set when temperature monitor value exceeds high warning warning level Temperature Low Set when temperature monitor value exceeds low warning warning level Vcc High warning Set when Vcc monitor value exceeds high warning level Vcc Low warning Set when Vcc monitor value exceeds Low warning level Laser Bias High warning Set when laser bias monitor value exceeds high warning level Laser Bias Low warning Set when laser bias monitor value exceeds low warning level
10 116 1 Tx Power High warning Set when Tx power monitor value exceeds high warning level Tx Power Low warning Set when Tx power monitor value exceeds low warning level Rx Power High warning Set when Rx power monitor value exceeds high warning level Rx Power Low warning Set when Rx power monitor value exceeds low warning level Reserved All bits set to Reserved All bits set to Reserved All bits set to 0..PIN ASSIGNMENT Pin Name Function/Description 1 NC No function definition 2 RX GND Receiver ground 3 RX GND Receiver ground 4 NC No function definition 5 NC No function definition 6 RX GND Receiver ground 7 RX Vcc Receiver power supply 8 SD LVTTL Signal detect output, internally pull up. Asserts high when input optical power level is above threshold. 9 RD- Receiver data output-, AC coupled internally. 10 RD+ Receiver data output+, AC coupled internally. 11 TX Vcc Transmitter power supply. 12 TX GND Transmitter ground
11 13 TX EN LVTTL transmitter burst mode control, L : TX ON. 14 TD+ LVPECL data input+, AC coupled internally. 15 TD- LVPECL data input-, AC coupled internally. 16 TX GND Transmitter ground. 17 SCL I 2 C serial clock (LVTTL) 18 SDA I 2 C serial data (LVTTL) 19 TX_FAULT LVTTL transmitter Fault, internally pull up, Assert high when the fault is detected by the laser driver. 20 TX_SD TX Transmitter State indication, TX_Indication high when transmitter ON Block Diagram
12 Typical Application Circuit
13 PACKAGE DIAGRAM (Units in mm)
14 - 14 -
FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)
FEATURES LC or SC receptacle optical interface compliant Single 3.3V power supply Hot-pluggable Uncooled 1490nm DFB laser transmitter Receiver loss of signal output AC/AC Coupling according to MSA Transmitter
More informationEPON ONU Optical Transceiver SFF Module
EPON ONU Optical Transceiver SFF Module SYFE420 Features Integrated Single fiber bi-directional optical subassembly SC receptacle optical interface 1310nm FP laser Burst-mode Transmitter and 1490nm PIN
More informationGPON OLT Optical Transceiver SFP Module RTXM RTXM Features
GPON OLT Optical Transceiver SFP Module RTXM167-522 Features Integrated Single fiber bi-directional optical subassembly 1310nm Burst-mode APD/TIA receiver and 1490nm Continuous DFB laser Transmitter (with
More information1.25G SFP transceiver with DDM function. RTXM191-xxx (DDM) Features
1.25G SFP transceiver with DDM function RTXM191-xxx (DDM) Features Up to 1.25Gbps data rate Duplex LC receptacle optical interface compliant Single +3.3V power supply DDM function implemented External
More informationLCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431
10GBASE-SR SFP+ Optical Transceiver FEATURES RoHS compliant Compliant to SFP+ Electrical MSA SFF-8431 Compliant with SFF-8472 MSA Compliant with CPRI protocols for wireless base station Standard LC duplex
More information1000BASE BX-10 SFP Transceiver modules (with DDM function) WST-SxSCx1-D5CH Series
DataSheet Features: 1.25Gbps data rate 1000Base BX-10 -D Single LC receptacle optical interface Transmitter disable input International Class 1 laser safety certified Single +3.3V power supply 1000Base
More informationLCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant
10GBASE-LR SFP+ Optical Transceiver FEATURES RoHS compliant Compliant to SFP+ Electrical MSA SFF-8431 Compliant with SFF-8472 MSA Standard LC duplex fiber-optic connector I 2 C for integrated Digital Optical
More informationLCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance
10GBASE-LR Lite SFP+ Optical Transceiver FEATURES RoHS compliance Compliant with SFP transceiver SFF-8472 MSA specification 1310nm FP laser Built-in digital diagnostic monitoring function Compliant with
More informationStratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)
FEATURES: SMPTE 292M/297M/259M/305M compliant (VMC-T- H-2) SMPTE 259M/297M/305M compliant (VMC-T-S-2) DVB/ASI compliant (VMC-T-H-2 and VMC-T-S-2) ATSC/SMPTE 310M compliant; 19.4 to 38.8Mbps (VMC-T-H-2
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationRC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual
RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,
More informationFIRERAY 5000 range USER GUIDE
FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.
More information100Gbps CFP Optical Transceiver RTXM
The RTXM290-401 is a hot pluggable 100Gbps small-form-factor transceiver module integrated with the high performance cooled 1310nm EML transmitter and high sensitivity PIN receiver.it is compliant to IEEE802.3ba
More informationSet-Up Procedures. Before You Start
Doc. 2272064, Rev. B Rel. 11/00 5000-ODA Amplifiers Ref. and Install. Manual Set-Up Procedures Before You Start In this section, you will find information about the following procedures: Checking the Optical
More informationRION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer Product Brochure & Data Sheet Headquarters: Phoenix, Arizona 20100, N 51st Ave, Suite
More informationRC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)
RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,
More informationFlameGard 5 UV/IR HART
FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized
More informationProduct Specification
Product Specification R9300TH Hybrid Raman-EDFA, Dual Raman Pump PN: FOA-R9300TH-HBR3C-AA001 Document No.: 1213710 Revision:A0 0 Date: 18-May-14 Customer: General Product Features Integrated Raman and
More informationDescription. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications
Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially
More informationFL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com
FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts
More informationM41T50 Serial Access Digital Input Real-Time Clock with Alarms
Serial Access Digital Input Real-Time Clock with Alarms PRELIMINARY DATA FEATURES SUMMARY TIMEKEEPING DOWN TO 1.3V 1.7V TO 3.6V I 2 C BUS OPERATING VOLTAGE OPERATES FROM 50Hz OR 60Hz DIGITAL CLOCK SIGNAL
More informationFiber Optics and Liquid Level Sensors Line Guide
Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication
More informationProduct Specification
Product Specification M7300CD Variable Gain EDFA, 17 dbm OP, 15-30 db Gain PN: FOA-M7300CD-EVG1C-AA002 Document No.: 1213704 Revision: A00 Date: 01-Apr-14 Customer: General Product Features Variable Gain
More informationECO N DATE DESCRIPTION OF CHANGE CHG
Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,
More informationHM-4201-RTCM High-Temp Real Time Clock Module
HM-4201-RTCM High-Temp Real Time Clock Module HM-4201-RTCM Product Description & Applications High Temp Real Time Clock/Calendar Module with Build-In 32.768KHz Crystal Oscillator. Timing, Calendar and
More informationMT-RJ Optical Fiber System Field Testing
MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)
More informationRS485 MODBUS Module 8AI
Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More information4 Channel Contact Closure SFP DIN Fiber Link System
USER GUIDE The leader in rugged fiber optic technology. U- 07A-0707 Channel Contact Closure DIN Fiber Link System Installation and Configuration Information Description The system provides transmission
More informationFlameGard 5 MSIR HART
FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be
More informationM41T81S. Serial Access Real-Time Clock with Alarms
Serial Access Real-Time Clock with Alarms FEATURES SUMMARY COUNTERS FOR TENTHS/HUNDREDTHS OF SECONDS, SECONDS, MINUTES, HOURS, DAY, DATE, MONTH, YEAR, AND CENTURY 32KHz CRYSTAL OSCILLATOR WITH INTEGRATED
More informationDescription. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications
Description The DFB-XXX-BF-10-EC-Fx-Hx-N126 laser modules are designed for fiber optic sensor applications. The narrow linewidth and the option of using polarization maintaining optical fiber made it specially
More informationT3/E3 Fiber Optic Line Drivers
MT618A-ST-R3 January 2004 MT619A-ST-R2 MT620AE-R2 T3/E3 Fiber Optic Line Drivers CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical
More informationEOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings
EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings Key Features Single and Dual Channel Self Healing Rings for High Reliability
More informationHFX Fiber Optic Component 50 Mbps, 650 nm LED
HFX7000-200 Fiber Optic Component 50 Mbps, 650 nm LED DESCRIPTION The HFX7000-200 is a 50 Mbps LED designed to meet data transmission requirements in factory or office automation. The 650 nm wavelength
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.
UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic
More informationETH1000-MKII. User manual
ETH1000-MKII Gigabit Ethernet Media Converter User manual Rev. 1 1 Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion
More information100Gb/s CFP2 Optical Transceiver RTXM
100Gb/s CFP2 Optical Transceiver RTXM290-608 Features Direct LC receptacle optical interface Single +3.3V power supply Hot-pluggable Operating optical data rate up to 112Gbps Transmission distance up to
More informationSeries Digital Controller Instruction Sheet
216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure
More informationMeridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA
HART Field Device Specification Meridian wiredhart 4320 Goldmine Rd. Monroe, NC 28110 USA HART is a registered trademark of the HART Communication Foundation TABLE OF CONTENTS 1. Introduction...5 1.1 Scope...5
More informationHM-4201-RTCM High-Temp Real Time Clock Module
HM-4201-RTCM High-Temp Real Time Clock Module HM-4201-RTCM Product Description & Applications High Temp Real Time Clock/Calendar Module with Build-In 32.768KHz Crystal Oscillator. Timing, Calendar and
More informationDC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1
DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove
More informationOPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL
ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982
More informationDS1286 Watchdog Timekeeper
www.dalsemi.com FEATURES Keeps track of hundredths of seconds, seconds, minutes, hours, days, date of the month, months, and years; valid leap year compensation up to 2100 Watchdog timer restarts an out-of-control
More informationFour channel video link For low cost video transmission
User Manual Four channel video link For low cost video transmission CFO First Mile series consist of fi bre optic modems which provide a high quality and losless video transmission for variety of CCTV
More informationHUM-M2 Humidity Sensor Module Description
HUM-M2 Humidity Sensor Module Description Humidity Sensor Modules are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for
More information100Gb/s CFP2 Optical Transceiver RTXM
100Gb/s CFP2 Optical Transceiver RTXM290-601 Features DirectLC receptacle optical interface Single +3.3V power supply Hot-pluggable Operating optical data rate up to 112Gbps Transmission distance up to
More informationIMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!
USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents
More informationAnalog Input Module IC670ALG630
1 IC670ALG630 The Thermocouple (IC670ALG630) accepts 8 independent thermocouple or millivolt inputs. Module features include: Self calibration Two data acquisition rates based on 50 Hz and 60 Hz line frequencies
More informationOTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL
OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200 SAFETY WARNINGS
More informationDS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM
DS 96/48 P Digital indicator Short manual 41/33-89 EN Rev. 00 A1 A2 DIM E 1 Safety instructions Correct and safe operation of the apparatus calls for expert installation and meticulous maintenance. This
More informationKey Features. General Description
Key Features SIL2 rated, for certified dependability (fail-safe detection) Special coating for electronics protection in harsh environments Dedicated temperature range, for maximum detection accuracy Individual
More informationCM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications
Cooled 980nm Pump Laser Module Features High output power, >1.0W kink free Fiber Bragg grating stabilization for wavelength locking over the entire operating conditions Hermetically sealed 10pin mini-butterfly
More informationMetasys Integrator Airflow Application
Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0998 APPLICATION NOTE Metasys Integrator Airflow Application lntroduction Page Application Details * Component
More informationRPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:
GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace,
More informationAdvanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LS-1310/1550 Service Information Sheet Introduction This Service Information Sheet provides the following service information
More informationAdaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV
CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...
More informationOWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015
Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical
More information200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION
GENERAL DESCRIPTION This product is the photo/thermal/ir variant of 2 Series Advanced, the redesigned 2 Series all SMD adopting the new chamber and a new style of covers. It works with the 2 Series extended
More informationSM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option
SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow
More informationDHM5150 Human Motion Sensor Module User Manual
DHM5150 Human Motion Sensor Module User Manual Version: 1.0.2 February 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Running as Part of WiRobot System 3 II.3.
More informationUSER MANUAL FOR OPERATING SYSTEM
P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177
More informationETH1000-D. User manual
ETH1000-D Gigabit Ethernet Media Converter with DWDM laser User manual Rev. 2 Nevion Europe P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www. Nevion Support Nevion Europe
More informationICS Regent. Fire Detector Input Modules PD-6032 (T3419)
ICS Regent Fire Detector Input Modules (T3419) Issue 1, March, 06 Fire detector input modules provide interfaces for 16 fire detector inputs such as smoke detectors, flame detectors, temperature detectors,
More informationDTSX200 Communications(Modbus) Guide
User s Manual DTSX200 Communications(Modbus) Guide 4th Edition Blank Page < Introduction > i Introduction About this Manual Thank you for purchasing the DTSX200 Distributed Temperature Sensor. This document
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F
LD-64F INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG 6073-2011 Westermo Teleindustri AB 2001 REV. C Galvanic Isolation Transient Protection Balanced Transmission CE Approved Redundant linjedelare
More informationSMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic
SPECIFICATION Product Name: Dust Sensor Model No. : SM-ND-02A ( Tentative ) SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration
More informationPureGain TM 2600 Variable Gain EDFA for Metropolitan Networks
FEATURES Variable Gain Amplifier with or without Mid-Stage Fully Integrated Control Electronics with State-of-the-Art Transient Suppression Control Three Standard Configurations Mk I: 17 dbm VGA (Variable
More informationHOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control
Wide Gap Transmissive Sensor HOA1888 Series FEATURES Choice of phototransistor or photodarlington output Visible ambient light and dust protective filter 12 mm (0.47 in.) slot width Snap-in housing The
More informationTPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal
Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal Specifications Size: (L122 x W123 x H104 mm) Series Interface: Half duplex RS-485 with transformer isolation Cable Type:
More informationRF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1
RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause
More informationIFS SFP Tranceivers User Manual
IFS SFP Tranceivers User Manual P/N 1069181 REV 02.00 ISS 22AUG11 Copyright Trademarks and patents Manufacturer 2011 UTC Fire & Security. All rights reserved. Interlogix, IFS SFP Tranceivers Brand and
More informationUser Guide OI/FEX100HART EN Rev. A. WaterMaster FEX100 HART Field Device Specification
User Guide OI/FEX100HART EN Rev. A WaterMaster FEX100 The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement,
More informationNIDS Dust sensor ED-N-DS-1408
SPECIFICATION (Tentative) Product Name: Dust Sensor(High Sensitivity) Model No. : SM-PWM-01A-HS SMART dust sensor for air purifier SM-PWM-01A-HS Description SM-PWM-01A-HS is a dust sensor that detects
More informationOPTICAL AMPLIFIERS SELECTION GUIDE
OPTICAL AMPLIFIERS SELECTION DE Finisar offers a wide selection of optical amplifiers, ranging in optical and electrical specification parameters, and in a variety of form factors and communications interfaces.
More informationDatabase for CTS6000 MODBUS
Database for CTS6000 MODBUS Valid for: LONcard SW1.7.4B, Variable List V2.02 Version 1.08-4, 01-05-2016 Contents Contents... 2 1. Installation... 3 1.1. Installation and operating instructions... 3 2.
More informationDatasheet: K-22 LO Sensor
Datasheet: K-22 LO Sensor The K- 22 LO is a CO2 sensor module designed to be built- in into stationary ventilation equipment, such as window vent or duct exhaust actuators, serving as a linear transmitter
More informationENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE
ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...
More informationTSEV01S01C10 SPECIFICATIONS
SPECIFICATIONS Contact less Temperature Measurement Small Size Heat Spreader improves Accuracy Wide Supply Voltage Range Digital Interface Bus (SPI) Connector Small Field of View The TSEV01S01C10 is a
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More informationOEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement
OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement DETECTABLE Gases: Sensor LS-1 R134a Sensor LS-2 R22 Sensor LS-3 CO 2 Sensor LS-4 R134, R404, R407, R410 Sensor LS-5 R134, R404, R407, R410,
More informationUser s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com
TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info CN616A Universal 6 Channel ¼ DIN Process Controller omega.com info@omega.com U.S.A. Headquarters:
More informationFiber Optical Multiplexer
Fiber Optical Multiplexer 8x E1, 1x Fast Ethernet, Hotline, 1x Fiber optic XL-FMUX4E1 User s Manual Thank you for using XtendLan s products. This manual will show you how to install and use this product.
More informationDescription. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1
Description The DFB-1XXX-BF-XX-CW-Fx-Hx-N127 series of Multi-Quantum Well (MQW) Distributed Feedback (DFB) lasers have been designed specifically to satisfy the requirements of the sensor application.
More informationRev Flame Detection Sensor. TF100 User Manual
Rev. 0.94 User Manual The is a sensitive flame detection sensor. This sensor has been developed with efficient algorithm on the basis of actual flame conditions, using accurate calibration apparatus. This
More informationmach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes
mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes Measure every pulse at pps! Our new mach 5 Digital Joulemeter is designed to measure laser pulse energy up to 130,000 pps with
More informationSingle Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link
AMG5614A3 Instruction Manual Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link The AMG5614A3 is a standalone one channel
More informationEndura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer
ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION SUPPLEMENT COM/AZ40/MOD-EN REV. A Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer Communications supplement Measurement made easy Oxygen
More informationCompod. Instruction Manual IM-COMPOD Revision: C.1, November 2010
Compod Programmable Control Module For 100 Series Digital Mass Flow Meters & Controllers Instruction Manual IM-COMPOD Revision: C.1, November 2010 CORPORATE HEADQUARTERS 5 Harris Court, Building L, Monterey,
More informationNoyes OFL 250B Specs Provided by
Noyes OFL 250B Specs Provided by www.aaatesters.com OFL 250 Handheld OTDR The Noyes OFL 250 from AFL Telecommunications is a single-mode OTDR with an integrated Optical Power Meter (OPM), Source (OLS),
More informationDust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12
SPECIFICATION Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12 SM-PWM-01A SMART dust sensor for home appliance Description SM-PWM-01A is a dust sensor that detects the dust particle concentration
More informationMINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR
Inno Mini 2 Specs Provided by www.aaatesters.com MOST ACCURATE COMPACT OTDR SOLA (Smart Optical Link Analyzer) 5 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory
More informationpalmotdr Series Handheld OTDR
palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),
More information4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head
4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.
More informationInstallation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified
Installation Instructions for the Table. Operating Specifications Analog Digital Characteristic Unit Min. Typ. Max. Min. Typ. Max., 2, 3 Supply voltage (V supply ): 3.3 Vdc 5.0 Vdc 3.0 4.75 3.3 5.0 3.6
More informationVIEW500 FASTEST STANDARD OTDR
FASTEST STANDARD OTDR SOLA, Simplify The OTDR Test Process 7 Touch Screen with Smart GUI 8GB Internal Storage with Internal SD Card & External USB Memory Built-In VFL, Light Source and OPM Fast Booting
More informationSmart GPS Antenna A1035-D
Smart GPS Antenna A description of Tyco Electronics GPS antenna module User s Manual - PRELIMINARY Version 1.0 Hardware Revision 01 This page was intentionally left blank. Revision History Revision History
More informationAgilent 81663A DFB Laser 8165xA Fabry-Perot Lasers
DFB Laser 8165xA Fabry-Perot Lasers Data Sheet Introduction The high power DFB Laser Source modules are best suited for optical amplifier test and DWDM system test applications. The Fabry-Perot Laser Sources
More informationM41T81. Serial Access Real-Time Clock with Alarms
Serial Access Real-Time Clock with Alarms FEATURES SUMMARY 2.0 TO 5.5V CLOCK OPERATING VOLTAGE COUNTERS FOR TENTHS/HUNDREDTHS OF SECONDS, SECONDS, MINUTES, HOURS, DAY, DATE, MONTH, YEAR, AND CENTURY AUTOMATIC
More informationFiberSensor Fiber Optic Intrusion Detection System (IDS)
FiberSensor Fiber Optic Intrusion Detection System (IDS) OPERATION & INSTALLATION MANUAL Dec 2009, Issue 3 1 Table of Contents 1.0 PRECAUTIONS... 2 2.0 GETTING STARTED... 3 System Components... 3 Operating
More informationLASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES
LASER DIODE NX8316XC 1 310 nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION The NX8316XC is a 1 310 nm Multiple Quantum Well (MQW) structured Distributed Feed-Back (DFB) laser diode
More information